Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Cooling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 541 records · Page 30

Design and Cooling Performance of Additively Manufactured Ceramic Turbine Vanes

Ceramic materials are of significant interest in aviation and power generation gas turbine engines due to their low density and ability to withstand high temperatures. Increased cycle thermal efficiency and higher specific power output is possible by incorporating ceramic components that enable high turbine inlet temperatures and lower required cooling airflow levels. However, ceramics can be difficult and costly to form into the complex shapes used in gas turbine components, often requiring specialized multi-step processes. Furthermore, ceramic components in the hottest areas of a gas turbine, such as vanes or blade shroud seals, will still likely require cooling which is challenging to implement in conventional ceramic manufacturing approaches. Therefore, this study presents a multidisciplinary approach that investigates the design, fabrication, and overall cooling effectiveness evaluation of additively manufactured (AM), polymer derived ceramic (PDC) turbine vanes. A thermo-mechanically optimized vane design was generated, ceramic additive manufacturing of the complex cooling configuration was developed, and quantification of the increase in overall cooling effectiveness was performed in a 1X scale, high-speed facility using infrared thermography. This study produced a PDC AM process, capable of printing complex internal cooling schemes in 1X scale turbine vanes. Furthermore, it was found that the optimized vane more than doubled the overall cooling effectiveness observed in the baseline design, which reasonably agreed with thermomechanical optimization model predictions. Additionally, the optimized ceramic vane outperformed an identical metal vane, in terms of area averaged cooling effectiveness, suggesting that the ceramic vane could operate at reduced coolant flowrates to achieve comparable levels of cooling performance.

Reynolds number↗

COOLING WATER ISSUES AND OPPORTUNITIES AT U.S. NUCLEAR POWER PLANTS

This report has been prepared for the Department of Energy, Office of Nuclear Energy (DOE-NE), for the purpose of providing a status report on the challenges and opportunities facing the U.S. commercial nuclear energy industry in the area of plant cooling water supply. The report was prompted in part by recent Second Circuit and Supreme Court decisions regarding cooling water system designs at existing thermo-electric power generating facilities in the U.S. (primarily fossil and nuclear plants). At issue in the courts have been Environmental Protection Agency regulations that define what constitutes “Best Technology Available” for intake structures that withdraw cooling water that is used to transfer and reject heat from the plant’s steam turbine via cooling water systems, while minimizing environmental impacts on aquatic life in nearby water bodies used to supply that cooling water. The report was also prompted by a growing recognition that cooling water availability and societal use conflicts are emerging as strategic energy and environmental issues, and that research and development (R&D) solutions to emerging water shortage issues are needed. In particular, cooling water availability is an important consideration in siting decisions for new nuclear power plants, and is an under-acknowledged issue in evaluating the pros and cons of retrofitting cooling towers at existing nuclear plants. Because of the significant ongoing research on water issues already being performed by industry, the national laboratories and other entities, this report relies heavily on ongoing work. In particular, this report has relied on collaboration with the Electric Power Research Institute (EPRI), including its recent work in the area of EPA regulations governing intake structures in thermoelectric cooling water systems.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

RHIC performance with 56 MHz RF and gold ion beams pre-cooled at lower energy

Presently there is an R&D ERL under construction at Collider-Accelerator Department (CAD) at BNL with its commissioning scheduled for FY09-10 [1]. The use of this full energy 21 MeV ERL in RHIC tunnel was recently proposed for a Proof-of-Principle demonstration of Coherent Electron Cooling of gold ions at 40 GeV/nucleon [2]. The purpose of this Note is to summarize numerical studies aimed at understanding the potential improvement of RHIC luminosity by using this R&D ERL for pre-cooling of Au ion beams with conventional electron cooling system at 40 GeV/nucleon. The constraints were such that electron beam parameters should be close to those expected from R&D ERL. Additionally, the cooling section in RHIC should not require major RHIC modification. As a result of these studies it was found that pre-cooling of gold ion at about 40 GeV/nucleon approximately doubles the average store luminosity of RHIC at top energy of 100 GeV/nucleon compared to the expected luminosity improvement with 56MHz RF upgrade [3, 4]. Significant luminosity improvement may be also gained on top of future expected luminosity performance with combined upgrades of 56MHz RF and all-plane stochastic cooling system with present beam parameters [5]. The electron beam parameters needed for such pre-cooling (see Table 1) are close to those expected from the R&D ERL which is presently under construction at BNL. With electron beam parameters from Table 1 it takes about 20 minutes to cool the transverse emittance of gold ions by a factor of two at 40 GeV/nucleon. Similar studies were done for protons as well. However, it was found that the electron beam parameters needed for pre-cooling of protons would require a significant upgrade of the present injector of the R&D ERL. Thus, discussion about protons is omitted from the present Note.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Liquid Cooling in Data Centers

Semiconductor manufacturers have aggressively attacked the problem of escalating microprocessor power consumption levels. Today, server manufacturers can purchase microprocessors that currently have power consumption levels capped at 100W maximum. However, total server power levels continue to increase, with the increase in power consumption coming from the supportin chipsets, memory, and other components. In turn, full rack heat loads are very aggressivley climbing as well, and this is making it increasingly difficult and cost-prohibitive for facility owners to cool these high power racks. As a result, facilities owners are turning to alternative, and more energy efficient, cooling solutions that deploy liquids in one form or another. The paper discusses the advent of the adoption of liquid-cooling in high performance computing centers. An overview of the following competing rack-based, liquid-cooling, technologies is provided: in-row, above rack, refrigerated/enclosed rack, rear door heat exchanger, and device-level (i.e., chip-level). Preparation for a liquid-cooled data center, retroft and greenfield (new), is discussed, with a focus on the key issues that are common to all liquid-cooling technologies that depend upon the delivery of water to the rack (or in some deployments, a Coolant Distribution Unit). The paper then discusses, in some detail, the actual implementation and deployment of a liquid device-level cooled (spray cooled) supercomputer at the Pacific Northwest National Laboratory. Initial results from a successful 30 day compliance test show excellent hardware stability, operating system (OS) and software stack stability, application stability and performance, and an availability level that exceeded expectations at 99.94%. The liquid-cooled supercomputer achieved a peak performance of 9.287 TeraFlops, which placed it at number 101 in the June 2007 Top500 fastest supercomputers worldwide. Long-term performance and energy efficiency testing is currently underway, and detailed results will be reported in upcoming publications.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Resilient cooling strategies – A critical review and qualitative assessment

The global effects of climate change will increase the frequency and intensity of extreme events such as heatwaves and power outages, which have consequences for buildings and their cooling systems. Buildings and their cooling systems should be designed and operated to be resilient under such events to protect occupants from potentially dangerous indoor thermal conditions. This study performed a critical review on the state-of-the-art of cooling strategies, with special attention to their performance under heatwaves and power outages. We proposed a definition of resilient cooling and described four criteria for resilience—absorptive capacity, adaptive capacity, restorative capacity, and recovery speed —and used them to qualitatively evaluate the resilience of each strategy. The literature review and qualitative analyses show that to attain resilient cooling, the four resilience criteria should be considered in the design phase of a building or during the planning of retrofits. The building and relevant cooling system characteristics should be considered simultaneously to withstand extreme events. A combination of strategies with different resilience capacities, such as a passive envelope strategy coupled with a low-energy space-cooling solution, may be needed to obtain resilient cooling. Finally, a further direction for a quantitative assessment approach has been pointed out.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Evolution of the Microstructure and Hardness of Fe-8Cr-2.1Mo-Si-V Die Steel at Different Cooling Rates after Hot Deformation

In this study, the effect of microstructure evolution, especially that involving the proeutectoid carbides, on hardness distribution of ledeburite steel containing 8% chromium content was investigated at different cooling rates after hot deformation. The continuous cooling transformation was carried out using a fully automatic transformation measuring apparatus under cooling rates in the range of 0.03-80 °C/s. The transformation temperatures, Ac1, Ac3 and Ms, were measured by dilatometry. A nanoindentation test was employed to evaluate the mechanical properties of the cooled specimens. The evolution of microstructure indicated that the proportion trend of the precipitated carbides was dependent on the cooling rates. In addition, a mixture of pearlite and proeutectoid carbides was observed under slow cooling rates in the range of 0.03-0.2 °C/s, for which only a martensite transformation took place in austenite, and the proeutectoid carbides precipitated negligibly at cooling rates greater than or equal to 10 °C/s. The results also showed that the nanohardness significantly decreased and then slowly increased to a stable value with increasing cooling rates, which was similar to the content trend of the carbides that precipitated during the cooling process.

36 MATERIALS SCIENCE↗

A novel stochastic modeling method to simulate cooling loads in residential districts

District cooling systems are widely used in urban residential communities in China. Most of such systems are oversized, which leads to wasted investment, low operational efficiency and, thus, waste of energy. The accurate prediction of district cooling loads that can support the rightsizing of cooling plant equipment remains a challenge. This study develops a novel stochastic modeling method that consists of (1) six prototype house models representing most apartments in a district, (2) occupant behavior models of residential buildings reflecting their spatial and temporal diversity as well as their complexity based on a large-scale residential survey in China, and (3) a stochastic sampling process to represent all apartments and occupants in the district. The stochastic method was applied to a case study using the Designer's Simulation Toolkit (DeST) to simulate the cooling loads of a residential district in Wuhan, China. The simulation results agreed well with the measured data based on five performance metrics representing the aggregated cooling consumption, the peak cooling loads, the spatial load distribution, the temporal load distribution and the load profiles. Two prevalent simulation methods were also employed to simulate the district cooling loads. Here, the results showed that oversimplified assumptions about occupant behavior could lead to significant overestimation of the peak cooling load and the total cooling loads in the district. Future work will aim to simplify the workflow and data requirements of the stochastic method for its application, and to explore its use in predicting district heating loads and in commercial or mixed-use districts.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Benefits assessment of cool skin and ventilated cavity skin: Saving energy and mitigating heat and grid stress

This study assessed the energy-saving and climate-adaptive potential of cool skin and ventilated cavity skin facade technologies in Seoul's high-rise apartment buildings. We created weather scenarios for historical, mid-term future, and long-term future conditions using Coordinated Regional Downscaling EXperiment (CORDEX) method. Building energy simulations were conducted on a South Korean high-rise apartment model to evaluate their performance under different weather conditions. The results indicate that cool skin and ventilated cavity skin technologies can save cooling energy during summers but lead to heating energy penalties in winters. Ventilated cavity skin outperforms cool skin, offering better cooling energy savings and reduced heating penalties. Combining both technologies yields the highest overall energy savings, with 7 %, 9 %, and 10 % cooling energy savings for cool skin, ventilated cavity skin, and the combined package, respectively. However, cool skin increases heating energy consumption by 5 %, while ventilated cavity skin has minimal impact on heating energy. These envelope technologies also reduce peak electricity demand by at least 5 %, 8 %, and 9 %, respectively. They contribute to heat stress reduction, enhance resilience, and decrease extreme heat risks for occupants during power outages by at least 18 % under various weather conditions. Considering the prevalence of aging high-rise apartments in South Korea, adopting these envelope renovation strategies can effectively reduce cooling loads, enhance thermal comfort, and boost resilience under future climates, while avoiding costly reconstruction.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Effect of a transparent water-cooled cathode on the neutron production rate in the glow discharge-type fusion neutron source

In glow discharge-type deuterium–deuterium fusion neutron sources, fusion reactions occurring on the cathode surface contribute significantly to the neutron production rate (NPR); therefore, cathode design plays a crucial role in enhancing NPR. Although the NPR generally increases with discharge current, deuterium desorption caused by cathode heating tends to stagnate it in the high-current regime. Water cooling has been shown to mitigate this stagnation for nontransparent cathodes, but its effectiveness for transparent cathodes has not been experimentally clarified. Here, in this study, a transparent cathode with active water cooling and a spherical geometry was designed and fabricated using stainless steel tubing. Neutron production experiments were conducted with and without water cooling: with water cooling, applied voltages of 20–40 kV were investigated, while without water cooling, the applied voltage was limited to 25 kV. The results showed that the NPR increased continuously with discharge current without stagnation when water cooling was applied. A maximum NPR of (1.8 ± 0.02) × 10 6 n/s was achieved at 40 kV and 50 mA. Compared with our previously reported disk cathode and nontransparent water-cooled cathode of the same diameter, the transparent water-cooled cathode exhibited a significantly enhanced NPR. These findings indicate that combining cathode transparency with active cooling is an effective strategy for improving neutron production in glow discharge-type fusion neutron sources.

43 PARTICLE ACCELERATORS↗

Elucidation of microstructural evolution of beta-type titanium alloy joint during friction stir welding using liquid CO2 cooling

Highlights: • Microstructural evolution during FSW was elucidated along real material flow line. • Stirring and cooling stages of FSW can be investigated separately using CO{sub 2} cooling. • In stirring stage, discontinuous dynamic recrystallization predominantly occurred. • In cooling stage, static recovery and grain growth mainly occurred. - Abstract: Normal friction stir welding (FSW) and liquid CO{sub 2} cooling FSW were conducted on the β-type Ti-15V-3Cr-3Al-3Sn (Ti-15-3, mass%) alloy plates under a processing condition. Since liquid CO{sub 2} cooling with high cooling efficiency can freeze the microstructure formed during the high-temperature stirring stage of FSW, it is possible to separately elucidate the microstructural evolution of the Ti-15-3 alloy during the high-temperature stirring stage and the post-stirring cooling stage in FSW. The deformation temperature during the normal and the CO{sub 2} cooling FSW was similar in the top and the bottom of stir zone, which is considered to be owing to that the top and bottom are located adjacent to the heat sources, i.e., the shoulder and probe surfaces. In the high-temperature stirring stage of FSW, discontinuous dynamic recrystallization predominantly occurred, and a simple shear texture generated in an early stage of the material flow around the tool, then the microstructure started to evolve steadily after a steady-state dynamic recrystallization. In the post-stirring cooling stage of FSW, static recovery and grain growth were found to mainly occur within the stir zone.

36 MATERIALS SCIENCE↗

Kinetics and extinction of non-premixed cool and warm flames of dimethyl ether at elevated pressure

Here, the growing demand of clean and efficient propulsion and energy systems has sparked an interest in understanding low-temperature combustion at high pressure. Cool flame transition and extinction limits as well as oxygen concentration dependence at elevated pressures provide insights of the low-temperature and high-pressure fuel reactivity. A new experimental high-pressure counterflow burner platform was designed and developed to achieve the studies of high-pressure cool flames. Dimethyl ether (DME) was chosen to study its non-premixed cool flame in high-pressure counterflow burner at pressure up to 5 atm, perhaps for the first time. This paper investigates the effects of pressure on cool flame structure, extinction and transition limits, and oxygen concentration dependence as well as ozone assisted warm flames of DME in experiments and numerical simulations. The results show that the reignition transition from cool flame to hot flame occurs either with the decrease of the strain rate at a given fuel concentration and pressure or with the increase of fuel mole fraction or pressure at a given strain rate. Furthermore, it is shown that the higher pressure shifts the cool flame to higher strain rates and results in higher cool flame extinction strain rates. However, the existing kinetic model of DME fails in predicting the cool flame extinction limit at elevated pressures. Besides, the cool flame extinction limits are proportional to nth power of the oxygen concentration, [O 2 ] n , and the increase of pressure leads to stronger extinction limit dependence (larger n) on oxygen concentration. The present experiment and detailed kinetic analysis show clearly that increasing pressure promotes the low-temperature chemistry including the oxygen addition reactions. In addition, stable warm flame was first experimentally observed by using DME at elevated pressure with ozone sensitization.

33 ADVANCED PROPULSION SYSTEMS↗

Near-field photonic cooling through control of the chemical potential of photons

Photonic cooling of matter has enabled both access to unexplored states of matter, such as Bose–Einstein condensates, and novel approaches to solid-state refrigeration. Critical to these photonic cooling approaches is the use of low-entropy coherent radiation from lasers, which makes the cooling process thermodynamically feasible. Recent theoretical work has suggested that photonic solid-state cooling may be accomplished by tuning the chemical potential of photons without using coherent laser radiation, but such cooling has not been experimentally realized. Here we report an experimental demonstration of photonic cooling without laser light using a custom-fabricated nanocalorimetric device and a photodiode. Here, we show that when they are in each other’s near-field—that is, when the size of the vacuum gap between the planar surfaces of the calorimetric device and a reverse-biased photodiode is reduced to tens of nanometres—solid-state cooling of the calorimetric device can be accomplished via a combination of photon tunnelling, which enhances the transport of photons across nanoscale gaps, and suppression of photon emission from the photodiode due to a change in the chemical potential of the photons under an applied reverse bias. This demonstration of active nanophotonic cooling—without the use of coherent laser radiation—lays the experimental foundation for systematic exploration of nanoscale photonics and optoelectronics for solid-state refrigeration and on-chip device cooling.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Cooling for SC devices of test cryomodule for ADS Injector II at IMP

The superconducting half-wave resonance cavities connected in series with superconducting solenoids will be applied to the Injector II of the Accelerator Driven Sub-critical System (ADS) to be built at the Modern Physics Institute, China. A test system has been developed for the purpose of performance test of the HWR cavities as well as validating the relevant technique for cooling the cavity and the solenoids together. It mainly comprises a cryogenic valve box (TVB), a test cryomodule (TCM1) and transfer lines. The TCM1 includes one HWR cavity, two superconducting solenoids, one cold BPM and their cooling system. The design of the TCM1 cryostat was carried out by the Shanghai Institute of Applied Physics (SINAP), CAS. Both the cavity and the solenoids will work at 4.4 K by bath cooling. The fast cooling down for the cavity from around 100 K to 120 K is required to avoid degrading of the cavity performance. After cool down and before energization, the solenoids should be warmed up to above 10 K and re-cooled down for the purpose of degaussing. The TCM1 can not only be cooled by using the dewar-filling system, but also operated by the refrigerator system. For the purpose of reducing the heat loads to the cold mass at 4 K from room temperature, thermal radiation shields cooled by liquid nitrogen flowing in tubing were employed. This paper presents the design details of cooling circuits and thermal shields of the TCM1 as well as related calculations and analyses.

43 PARTICLE ACCELERATORS↗

Feasibility of cooling positrons via conduction in conductive micro-tubes

A first order perturbation with respect to velocity has been employed to find the frictional damping force imposed on a single moving charge inside a conductive cylindrical micro-tube. The tensorial relationship between the force and velocity is derived and numerically estimated. Our results asymptotically match that of a flat geometry presented in the literature. Using the single particle analysis the cooling is formulated for an arbitrary density ensemble. It is shown that no further cooling via conduction occurs in the well-established non-neutral plasma equilibrium state. Also, the cooling rate for a weakly interacting ensemble is estimated. It is shown micro-tubes can be employed to cool down low density positron ensembles and/or to improve the beam emittance. A pack of tens of thousands of individual micro-tubes, each cooling only tens of positrons, is capable of cooling hundreds of thousands of particles in each cooling cycle. For example, with tens of particles per micro-tube in a 5 cm long micro-tube stack with the resistivity of 0.46 Ωm and the tubes of radius 50 μm, hundreds of thousands of positrons can be cooled down with a time constant of 103 μs in longitudinal and 7 μs in perpendicular direction. However, it must be noted that the cooling does not guarantee long term storage of particles in micro-tubes.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Simulation of an active cooling system for photovoltaic modules

Photovoltaic cells are devices that convert solar radiation directly into electricity. However, solar radiation increases the photovoltaic cells temperature [1] [2]. The temperature has an influence on the degradation of the cell efficiency and the lifetime of a PV cell. This work reports on a water cooling technique for photovoltaic panel, whereby the cooling system was placed at the front surface of the cells to dissipate excess heat away and to block unwanted radiation. By using water as a cooling medium for the photovoltaic solar cells, the overheating of closed panel is greatly reduced without prejudicing luminosity. The water also acts as a filter to remove a portion of solar spectrum in the infrared band but allows transmission of the visible spectrum most useful for the PV operation. To improve the cooling system efficiency and electrical efficiency, uniform flow rate among the cooling system is required to ensure uniform distribution of the operating temperature of the PV cells. The aims of this study are to develop a 3D thermal model to simulate the cooling and heat transfer in Photovoltaic panel and to recommend a cooling technique for the PV panel. The velocity, pressure and temperature distribution of the three-dimensional flow across the cooling block were determined using the commercial package, Fluent. The second objective of this work is to study the influence of the geometrical dimensions of the panel, water mass flow rate and water inlet temperature on the flow distribution and the solar panel temperature. The results obtained by the model are compared with experimental results from testing the prototype of the cooling device.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Semioptimal practicable algorithmic cooling

Algorithmic cooling (AC) of spins applies entropy manipulation algorithms in open spin systems in order to cool spins far beyond Shannon's entropy bound. Algorithmic cooling of nuclear spins was demonstrated experimentally and may contribute to nuclear magnetic resonance spectroscopy. Several cooling algorithms were suggested in recent years, including practicable algorithmic cooling (PAC) and exhaustive AC. Practicable algorithms have simple implementations, yet their level of cooling is far from optimal; exhaustive algorithms, on the other hand, cool much better, and some even reach (asymptotically) an optimal level of cooling, but they are not practicable. We introduce here semioptimal practicable AC (SOPAC), wherein a few cycles (typically two to six) are performed at each recursive level. Two classes of SOPAC algorithms are proposed and analyzed. Both attain cooling levels significantly better than PAC and are much more efficient than the exhaustive algorithms. These algorithms are shown to bridge the gap between PAC and exhaustive AC. In addition, we calculated the number of spins required by SOPAC in order to purify qubits for quantum computation. As few as 12 and 7 spins are required (in an ideal scenario) to yield a mildly pure spin (60% polarized) from initial polarizations of 1% and 10%, respectively. In the latter case, about five more spins are sufficient to produce a highly pure spin (99.99% polarized), which could be relevant for fault-tolerant quantum computing.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Ion-chain sympathetic cooling and gate dynamics

Sympathetic cooling is a technique often employed to mitigate motional heating in trapped-ion quantum computers. However, choosing system parameters such as number of coolants and cooling duty cycle for optimal gate performance requires evaluating trade-offs between motional errors and other slower errors such as qubit dephasing. The optimal parameters depend on cooling power, heating rate, and ion spacing in a particular system. In this study, we aim to analyze best practices for sympathetic cooling of long chains of trapped ions using analytical and computational methods. We use a case study to show that optimal cooling performance is achieved when coolants are placed at the center of the chain and provide a perturbative upper bound on the cooling limit of a mode given a particular set of cooling parameters. In addition, using computational tools, we analyze the trade-off between the number of coolant ions in a chain and the center-of-mass mode heating rate. We also show that cooling as often as possible when running a circuit is optimal when the qubit coherence time is otherwise long. These results provide a roadmap for how to choose sympathetic cooling parameters to maximize circuit performance in trapped-ion quantum computers using long chains of ions.

Cooling & trapping↗

Full coverage shaped-hole film cooling in an accelerating boundary layer with high freestream turbulence

Full coverage shaped-hole film cooling and downstream heat transfer measurements have been acquired in the accelerating flows over a large cylindrical leading edge test surface. The shaped holes had an 8 deg lateral expansion angled at 30 deg to the surface with spanwise and streamwise spacings of 3 diameters. Measurements were conducted at four blowing ratios, two Reynolds numbers, and six well documented turbulence condi-tions. Film cooling measurements were acquired over a four to one range in blowing ratio at the lower Reynolds number and at the two lower blowing ratios for the higher Reynolds number. The film cooling measurements were acquired at a coolant to free-stream density ratio of approximately 1.04. The flows were subjected to a low turbulence (LT) condition (Tu = 0.7%), two levels of turbulence for a smaller sized grid (Tu = 3.5%and 7.9%), one turbulence level for a larger grid (8.1%), and two levels of turbulence generated using a mock aerocombustor (AC) (Tu = 9.3% and 13.7%). Turbulence level is shown to have a significant influence in mixing away film cooling coverage progressively as the flow develops in the streamwise direction. Effectiveness levels for the AC turbu-lence condition are reduced to as low as 20% of LT values by the furthest downstream region. The film cooling discharge is located close to the leading edge with very thin and accelerating upstream boundary layers. Film cooling data at the lower Reynolds number show that transitional flows have significantly improved effectiveness levels compared with turbulent flows. Downstream effectiveness levels are very similar to slot film cooling data taken at the same coolant flow rates over the same cylindrical test surface. However, slots perform significantly better in the near discharge region. These data are expected to be very useful in grounding computational predictions of full coverage shaped-hole film cooling with elevated turbulence levels and acceleration. Lastly, infrared (IR) measurements were performed for the two lowest turbulence levels to document the spanwise variation in film cooling effectiveness and heat transfer.

20 FOSSIL-FUELED POWER PLANTS↗