Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Contamination”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 541 records · Page 30

The V-3 contamination test of the chamber A facility and a subsequent cryogenic/vacuum study of the V-3 test quartz crystal microbalance

The areas of orbital and ground contamination of flight experiment hardware have been well established. This report relates directly to results of vacuum chamber testing for the ground evaluation of flight experiment hardware performance. First, the data obtained during the V-3 contamination testing in the Johnson Space Center's Chamber A space simulation test facility are presented. Second, during the V-3 contamination tests, the MSFC Space Sciences Laboratory's quartz crystal microbalance exhibited two periods of anomalous readings. Therefore, a subsequent small chamber tests was conducted in a controlled cryogenic/vacuum environment. The objective was to reproduce with known parameters the anomalous behavior patterns of the V-3 test data. Analyses of the anomalous readings are made on the basis of these tests. Additionally, as a by-product of the small chamber tests, calibration curves then existing for the quartz crystal microbalance were empirically extended, and certain data-formatting aids were documented.

Moore, W. W., Jr.↗

Active cleaning techniques for removing contamination from optical surfaces in space

Research in developing an active cleaning technique for removing contaminants from optical surfaces in space is reported. In situ contamination/cleaning experiments were conducted on gold and platimum coated mirrors, which were contaminated by exposure to UV radiation in a 1,3, butadiene environment. Argon and oxygen plasma exposure cleaned the mirrors equally well. Silicone cleaning experiments were also conducted. Exposure of the contaminated mirrors to helium, oxygen, and hydrogen plasmas restored the reflectance at the shorter wavelengths and degraded it at the longer wavelengths.

Shannon, R. L.↗

Contamination assessment and control in scientific satellites

Techniques for assessment and control of the contamination environment for both particulates and condensible vapors in the vicinity of spacecraft are developed. An analysis of the deposition rate on critical surfaces is made considering sources within the line of sight of the surface in question as well as those obscured from the line of sight. The amount of contamination returned by collision with the surrounding atmosphere is estimated. Scattering and absorption from the induced atmosphere of gases and particulates around the spacecraft are estimated. Finally, design techniques developed for Skylab to reduce the contamination environment to an acceptable level are discussed.

Naumann, R. J.↗

Terrestrial contamination in Apollo lunar samples.

The contamination prevention procedures adopted for controlling the collection, processing, and analysis of the Apollo lunar samples in order to keep them free of significant levels of terrestrial organic matter are described. The organic contaminants actually found in the samples by the various investigators are summarized. It is shown that the program succeeded in providing investigators with samples containing less than 0.1 ppm total contamination.

Flory, D. A.↗

SMEAT atmosphere trace contaminants.

The atmosphere trace contaminant analysis support provided for the Skylab Medical Experiments Altitude Test (SMEAT) which was conducted from July 26 through September 20, 1972, at the JSC Crew Systems Division facility is discussed. Sample acquisition techniques and analytical instrumentation methodology utilized for identification and quantification of the trace contaminants are described. Emphasis is placed on the contaminants found, their occurrence patterns, and possible sources.

Schornick, J. L.↗

Active cleaning technique for removing contamination from optical surfaces in space

An active cleaning technique for removing contaminants from optical surfaces in space was investigated with emphasis on the feasibility of using plasma exposure as a means of in-situ cleaning. The major work accomplished includes: (1) development of an in-situ reflectometer for use in conjunction with the contaminant film deposition/cleaning facility; (2) completion of Apollo Telescope Mount (ATM) filter treatment experiments to assess the effects of plasma exposure on the UV transmittance; (3) attempts to correlate the atomic oxygen flux with cleaning rate; (4) completion of in-situ butadien contamination/plasma cleaning/UV reflectance measurement experiments; (5) carbon cleaning experiments using various gases; (6) completion of silicone contamination/cleaning experiments; and (7) experiments conducted at low chamber pressures to determine cleaning rate distribution and contamination of surfaces adjacent to those being cleaned.

Shannon, R. L.↗

Effects of low-pressure air on oxygen contamination and lithium corrosion of a tantalum alloy, T-111, at 980 and 1260 C

The effects were studied of low-pressure air on contamination and corrosion in the tantalum alloy T-111/lithium system at 980 and 1260 C. Capsules of T-111 containing lithium were exposed to six vacuum levels between 1 x 10 to the 8th power and 0.0003 torr by controlled air leakage into a vacuum system. Capsules exposed at 980 C and 0.0002 torr failed from intragranular oxidation. The remainder of the capsules completed the 96-hour tests. The depth of oxygen contamination was greater at 980 C than at 1260 C. Tests made at 0.0001 and 0.00001 torr levels caused large increases in the oxygen content of the T-111. Tests at 0.000001 torr or less produced no significant contamination. No lithium corrosion of the T-111 was observed under any of the conditions.

Gahn, R. F.↗

Assessment of the probability of contaminating Mars

New methodology is proposed to assess the probability that the planet Mars will by biologically contaminated by terrestrial microorganisms aboard a spacecraft. Present NASA methods are based on the Sagan-Coleman formula, which states that the probability of contamination is the product of the expected microbial release and a probability of growth. The proposed new methodology extends the Sagan-Coleman approach to permit utilization of detailed information on microbial characteristics, the lethality of release and transport mechanisms, and of other information about the Martian environment. Three different types of microbial release are distinguished in the model for assessing the probability of contamination. The number of viable microbes released by each mechanism depends on the bio-burden in various locations on the spacecraft and on whether the spacecraft landing is accomplished according to plan. For each of the three release mechanisms a probability of growth is computed, using a model for transport into an environment suited to microbial growth.

Judd, B. R.↗

Study to define points of entry for potential contaminants in limestone aquifers

Visual examinations of both prints and transparencies from ERTS 1 and U-2 aircraft imagery provided a method for discovering possible points of entry of potential contaminants into the limestone aquifer in Madison County, Alabama. Knowledge of the locations at which contaminants could enter the aquifer is an important consideration in water quality management, particularly for regions that depend, at least partially, on ground water for their water supply. ERTS 1 imagery recorded on December 28, 1972 in the Multispectral Scanner-5 (MSS-5) and MSS-7 bands, and a false-color composite of the MSS-4 (green), MSS-5 (red), and MSS-7 (near infrared) bands were the principal materials used, along with thermography recorded by an RS-7 infrared scanner onboard a U-2 aircraft. The results of the study are discussed in detail, providing information on prominent lineations and major fracture trends which are related to aquifer contamination. Maps depicting the observations are also presented.

Doyle, F. L.↗

Test evaluation of potential heatshield contamination of an outer planet probe's gas sampling system

The feasibility of retaining the heat shield for outer planet probes was investigated as a potential source of atmospheric sample contamination by outgassing. The onboard instruments which are affected by the concept are the pressure sensor, temperature sensor, IR detector, nephelometer, and gas sampling instruments. It was found that: (1) The retention of the charred heatshield and the baseline atmospheric sampling concepts are compatible with obtaining noncontaminated atmospheric samples. (2) Increasing the sampling tube length so that it extends beyond the viscous boundary layer eliminates contamination of the atmospheric sample. (3) The potential for contamination increases with angle of attack.

Kessler, W. C.↗

Analytical study of spacecraft deposition contamination by internal reflection spectroscopy

The in-situ vacuum chamber designed around the IRE was tested under vacuum. The contamination analyzer system was tested using two liquid contaminant materials. The analysis of the contaminants on the SL-4 rendezvous window shows that the material has methyl silicone, hydroxyl, and carbonyl radicals. The analysis of the outgassing material from Shuttle TPS shows silicone as the primary product.

Mookherji, T. K.↗

Evaluation and study of advanced optical contamination, deposition, measurement, and removal techniques

A program is described to design, fabricate and install an experimental work chamber assembly (WCA) to provide a wide range of experimental capability. The WCA incorporates several techniques for studying the kinetics of contaminant films and their effect on optical surfaces. It incorporates the capability for depositing both optical and contaminant films on temperature-controlled samples, and for in-situ measurements of the vacuum ultraviolet reflectance. Ellipsometer optics are mounted on the chamber for film thickness determinations, and other features include access ports for radiation sources and instrumentation. Several supporting studies were conducted to define specific chamber requirements, to determine the sensitivity of the measurement techniques to be incorporated in the chamber, and to establish procedures for handling samples prior to their installation in the chamber. A bibliography and literature survey of contamination-related articles is included.

Linford, R. M. F.↗

Value contamination avoidance devices

Mechanical redesign methods were used to minimize contamination damage of conventional fluid components and a contamination separator device was developed for long term reusable space vehicles. These were incorporated into an existing 50.8 mm poppet valve and tested for damage tolerance in a full size open loop flow system with gaseous and liquid nitrogen. Cyclic and steady flow conditions were tested with particles of 125 to 420 micrometers aluminum oxide dispersed in the test fluids. Nonflow life tests (100,000 cycles) were made with two valve configurations in gaseous hydrogen. The redesigned valve had an acceptable cycle life and improved tolerance to contamination damage when the primary sealing surfaces were coated with thin coatings of hard plastic (Teflon S and Kynar). Analytical studies and flow testing were completed of four different versions of the separator. overall separation efficiencies in the 55-90% range were measured with these non-optimum configurations.

Endicott, D. L.↗

Contamination control in hybrid microelectronic modules. Part 3: Specifications for coating material and process controls

Resin systems for coating hybrids prior to hermetic sealing are described. The resin systems are a flexible silicone junction resin system and a flexible cycloaliphatic epoxy resin system. The coatings are intended for application to the hybrid after all the chips have been assembled and wire bonded, but prior to hermetic sealing of the package. The purpose of the coating is to control particulate contamination by immobilizing particles and by passivating the hybrid. Recommended process controls for the purpose of minimizing contamination in hybrid microcircuit packages are given. Emphasis is placed on those critical hybrid processing steps in which contamination is most likely to occur.

Himmel, R. P.↗

Molecular contamination study by interaction of a molecular beam with a platinum surface

The capability of molecular beam scattering from a solid surface is analyzed for identification of molecular contamination of the surface. The design and setup of the molecular beam source and the measuring setup for the application of a phase sensitive measuring technique for the determination of the scattered beam intensity are described. The scattering distributions of helium and nitrogen molecular beams interacting with a platinum surface were measured for different amounts of contamination from diffusion pump oil for surface temperatures ranging from 30 to 400 C. The results indicate the scattering of molecular beams from a platinum surface is a very sensitive method for detecting surface contamination.

Nuss, H. E.↗

Optimization of contaminated oxide inversion layer solar cell

Contaminated oxide cells have been fabricated with efficiencies of 8.6% with values of I sub sc = 120 ma, V sub oc = .54 volts, and curve factor of .73. Attempts to optimize the fabrication step to yield a higher output have not been successful. The fundamental limitation is the inadequate antireflection coating afforded by the silicon dioxide coating used to hold the contaminating ions. Coatings of SiO, therefore, were used to obtain a good antireflection coating, but the thinness of the coatings prevented a large concentration of the contaminating ions, and the cells was weak. Data of the best cell were .52 volts V sub oc, 110 ma I sub sc, .66 CFF and 6.7% efficiency.

Call, R. L.↗

Preliminary study of contaminant particulates around Skylab

Techniques originally developed for the Skylab T025 contamination experiment were applied to S052 white-light coronagraph data in a preliminary study to investigate particulates around Skylab. Periods were selected which contained some contamination, even though there were no apparent dumps or vents during these periods. Velocity and size distributions were determined from optical data for particles within 200 meters of the spacecraft. Both photographic (61 particle tracks) and video (34 particles) observations yield an upper limit on particle radius of 100 micrometers. Selected photometric data from the S073 zodiacal light experiment during mission SL-2 were also examined for evidence of contamination.

Schuerman, D. W.↗

Monopropellant thruster exhaust plume contamination measurements

The potential spacecraft contaminants in the exhaust plume of a 0.89N monopropellant hydrazine thruster were measured in an ultrahigh quartz crystal microbalances located at angles of approximately 0 deg, + 15 deg and + or - 30 deg with respect to the nozzle centerline. The crystal temperatures were controlled such that the mass adhering to the crystal surface at temperatures of from 106 K to 256 K could be measured. Thruster duty cycles of 25 ms on/5 seconds off, 100 ms on/10 seconds off, and 200 ms on/20 seconds off were investigated. The change in contaminant production with thruster life was assessed by subjecting the thruster to a 100,000 pulse aging sequence and comparing the before and after contaminant deposition rates. The results of these tests are summarized, conclusions drawn, and recommendations given.

Baerwald, R. K.↗