Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Configuration Management”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 541 records · Page 30

Analyzing the Effects of Climate and Thermal Configuration on Community Energy Storage Systems (Presentation)

Community energy storage (CES) has been proposed to mitigate the high variation in output from renewable sources and reduce peak load on the electrical grid. Thousands of these systems may be distributed around the grid to provide benefits to local distribution circuits and to the grid as a whole when aggregated. CES must be low cost to purchase and install and also largely maintenance free through more than 10 years of service life to be acceptable to most utilities.Achieving the required system life time is a major uncertainty for lithium-ion batteries. The lifetime and immediate system performance of batteries can change drastically with battery temperature, which is a strong function of system packaging, local climate, electrical duty cycle, and other factors. In other Li-ion applications, this problem is solved via air or liquid heating and cooling systems that may need occasional maintenance throughout their service life. CES requires a maintenance-free thermal management system providing protection from environmental conditions while rejecting heat from a moderate electrical duty cycle. Thus, the development of an effective, low-cost, zero-maintenance thermal management system poses a challenge critical to the success of CES. NREL and Southern California Edison have collaborated to evaluate the long-term effectiveness of various CES thermal configurations in multiple climates by building a model of CES based on collected test data, integrating it with an NREL-developed Li-ion degradation model, and applying CES electrical duty cycles and historic location-specific meteorological data to forecast battery thermal response and degradation through a 10-year service life.

25 ENERGY STORAGE↗

Influence of Agricultural Managed Aquifer Recharge (AgMAR) and Stratigraphic Heterogeneities on Nitrate Reduction in the Deep Subsurface

Agricultural managed aquifer recharge (AgMAR) is a strategy whereby surface water is used to intentionally flood croplands to recharge underlying aquifers. However, nitrate (NO 3 - ) contamination in agriculturally intensive regions poses a threat to groundwater resources under AgMAR. We use a reactive transport model to understand the effects of AgMAR management strategies (i.e., by varying the frequency, duration between flooding events, and amount of water) on NO 3 - leaching to groundwater under different stratigraphic configurations and antecedent moisture conditions. We examine the potential of denitrification and nitrogen retention in deep vadose zone sediments (~15 m) using variable AgMAR application rates on two-dimensional representations of differently textured soils, soils with discontinuous bands/channels, and with preferential flow paths characteristic of agricultural fields. Simulations indicate finer textured sediments, alone or embedded within/adjacent to high flow regions, are important reducing zones providing conditions needed for denitrification. Simulation results suggest that applying water all-at-once rather than in increments transports higher concentrations of NO 3 - deeper into the profile, which may exacerbate groundwater quality. This transport into deeper depths can be aggravated by wetter antecedent soil moisture conditions. However, applying water all-at-once also increases denitrification within the vadose zone by promoting anoxic conditions. We conclude that AgMAR can be designed to enhance denitrification in the subsurface and reduce NO 3 - leaching to groundwater, while specifically accounting for lithologic heterogeneity, antecedent soil moisture conditions, and depth to the water table. Our findings are potentially relevant to other systems that experience flooding inundation such as floodplains and dedicated recharge basins.

54 ENVIRONMENTAL SCIENCES↗

Decommissioning Characterisation Through Compressive Gamma-Ray Imaging - 19308

We present the imaging results from two novel single pixel gamma-ray imaging systems, developed at ANSTO, in order to support the characterisation phase of decommissioning activities. The ability to remotely locate, identify, and quantify gamma emitting radionuclides can provide crucial information for the development of an efficient decommissioning plan. The imaging systems have been designed around the theory of compressed sensing and make use of a single spectroscopic detector and a set of dual, rotating, nested tungsten masks. The imaging system designs provide a large field of view and cover an energy range of 40 keV to 1.5 MeV. The first system has been specifically developed to image the High Flux Australian Reactor (HIFAR) reactor vessel with a hemispherical 2π field of view and provided quantitative information on the location of the gamma-ray emitting radionuclides present, whilst operating in a ∼10 Sv/h dose rate environment. The second system is a portable, high sensitivity imager with a cylindrical 360 deg. x 90 deg. field of view used for localising and identifying low to medium dose rate sources in the remaining facility infrastructure. Gamma-ray images were then accurately overlaid on optical images to allow for easy visualisation of the location of gamma emitting radionuclides. The spectroscopic gamma-ray imaging of point sources has been demonstrated with only 1/10. of the measurements normally required by traditional aperture based imaging techniques. The compressive gamma-ray imaging technique provides a novel and highly configurable spectroscopic imaging capability for applications in the nuclear industry. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Modeling of the Reactor Core Isolation Cooling Response to Beyond Design Basis Operations - Interim Report

Efforts are being pursued to develop and qualify a system-level model of a reactor core isolation (RCIC) steam-turbine-driven pump. The model is being developed with the intent of employing it to inform the design of experimental configurations for full-scale RCIC testing. The model is expected to be especially valuable in sizing equipment needed in the testing. An additional intent is to use the model in understanding more fully how RCIC apparently managed to operate far removed from its design envelope in the Fukushima Daiichi Unit 2 accident. RCIC modeling is proceeding along two avenues that are expected to complement each other well. The first avenue is the continued development of the system-level RCIC model that will serve in simulating a full reactor system or full experimental configuration of which a RCIC system is part. The model reasonably represents a RCIC system today, especially given design operating conditions, but lacks specifics that are likely important in representing the off-design conditions a RCIC system might experience in an emergency situation such as a loss of all electrical power. A known specific lacking in the system model, for example, is the efficiency at which a flashing slug of water (as opposed to a concentrated jet of steam) could propel the rotating drive wheel of a RCIC turbine. To address this specific, the second avenue is being pursued wherein computational fluid dynamics (CFD) analyses of such a jet are being carried out. The results of the CFD analyses will thus complement and inform the system modeling. The system modeling will, in turn, complement the CFD analysis by providing the system information needed to impose appropriate boundary conditions on the CFD simulations. The system model will be used to inform the selection of configurations and equipment best suitable of supporting planned RCIC experimental testing. Preliminary investigations with the RCIC model indicate that liquid water ingestion by the turbine decreases the developed turbine torque; the RCIC speed then slows, and thus the pump flow rate to the RPV decreases. Subsequently, RPV water level decreases due to continued boiling and the liquid fraction flowing to the RCIC decreases, thereby accelerating the RCIC and refilling the RPV. The feedback cycle then repeats itself and/or reaches a quasi-steady equilibrium condition. In other words, the water carry-over is limited by cyclic RCIC performance degradation, and hence the system becomes self-regulating. The indications achieved to date with the system model are more qualitative than quantitative. The avenues being pursued to increase the fidelity of the model are expected to add quantitative realism. The end product will be generic in the sense that the RCIC model will be incorporable within the larger reactor coolant system model of any nuclear power plant or experimental configuration.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Advances in Geophysical Monitoring Methods to Support Groundwater Remedies - 19096

Monitoring plays an important role in supporting remedial investigations and selection of remedies for groundwater contamination and for assessing performance during implementation of remedies. When a groundwater plume is near the interface between groundwater and surface water, the dynamics of groundwater flow at this interface needs to be considered in the design and implementation of a remedy. For this and other aquifer situations, groundwater flow dynamics may be difficult to evaluate through groundwater head measurements due to a sparse monitoring-well network, a relatively flat hydraulic gradient, or the presence of induced gradients from pumping operations or groundwater mounds. Geophysical approaches, coupled with other targeted measurements or the use of an ionic tracer, provide temporal data that can quantify groundwater flow dynamics. Recent developments include a flux-monitoring tool that measures fluid conductivity, bulk conductivity, and temperature at the interface between groundwater and surface water. Joint interpretation of these local data with temporal two- or three-dimensional geophysical data improves quantification of groundwater and mass flux at a targeted location. In addition, geophysical design improvements that enable the use of numerical simulations to evaluate implementation configurations and expected data resolution for geophysical methods identify threshold conditions for successful monitoring and identify the most cost-effective configurations to meet monitoring objectives. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Thermal Management System of an Outer-Rotor-Motor-Based Traction Drive With Integrated Power Electronics in its Central Cavity

Increasing power densities of electric vehicle traction drive systems necessitates combining the electric motor and the power electronics into one unit. A compact, integrated traction drive unit with fewer components also drives production costs down, enabling wider adoption of electric vehicles. However, the integration of power electronics in the electric machine is associated with challenges of designing an effective thermal management solution for the combined traction drive system. This paper focuses on the thermal management approach selected for Oak Ridge National Laboratory’s outer-rotor-motor-based integrated traction drive and evaluates its potential performance. The outer-rotor-motor configuration provided an opportunity for integration of the six-phase inverter in the available space in the central cavity of the internal stator. A cylindrical inverter enclosure with integrated coolant (water-ethylene glycol) channels in its walls was designed to enable heat removal from the power electronics. Numerical thermal-fluid modeling and initial channel/fin optimization results for the cylindrical heat sink are presented here. As permanent magnets are integrated in a high-speed (20 000 RPM) outer rotor, forced air convection provides cooling for the magnets. The magnets were segmented axially to mitigate the eddy current losses. Heat generated in the stator windings and laminations is removed by water-ethylene glycol coolant circulating in interpolar T-shape ceramic heat exchangers inserted between windings. General design concepts and numerical thermal-fluid simulations illustrating the electric motor thermal management solution are also presented.

Kekelia, Bidzina↗

TU-PIS-Exhibit Hall-01: CT Dose Optimization Technologies II

Partners in Solutions is an exciting new program in which AAPM partners with our vendors to present practical “hands-on” information about the equipment and software systems that we use in our clinics. The imaging topic this year is CT scanner dose optimization capabilities. Note that the sessions are being held in a special purpose room built on the Exhibit Hall Floor, to encourage further interaction with the vendors. Siemens‘ Commitment to the Right Dose in Computed Tomography Presentation Time: 11:15 - 11:45 AM Providing sustainable clinical results at highest patient safety: This is the challenge in medical imaging. Especially for Computed Tomography this means applying not simply the lowest, but the right dose for sound diagnostic imaging. Consequently, Siemens is committed to deliver the right dose in CT. In order to reduce radiation to the right dose, the first step is to provide the right dose technology. Through decades of research and development in CT imaging, Siemens CT has constantly introduced new ideas leading to a comprehensive portfolio of unique CARE technologies to deliver the right dose. For example automated kV adjustment based on patient size and the clinical question with CARE kV and three generations of iterative reconstruction. Based on the right dose technology, the next step is to actually scan at the right dose. For this, it is key to know the right dose targets for every examination. Siemens continuously involves CT experts to push developments further and outline how users can best adapt their procedures to the right dose. For users to know whether they met the right dose targets, it is therefore important to understand and monitor the actual absolute dose values. All scanners are delivered with defined default protocols which automatically use the available right dose technologies. Finally, to deliver the right dose not just in singular cases, but ideally to patients everywhere, organizations need then to manage dose across their institutions. Here Siemens offers the right dose management tools for administrations to analyze and document dose, to train their clinical staff and to continuously optimize the application of the right dose in clinical routine. Siemens CT is not only adhering to the ALARA principle, but is inspired by it. With CARE Right Siemens show their commitment to the right dose in CT. Toshiba Aquilion CT Dose Management Tools Presentation Time: 11:45 - 12:15 PM A practical review of Toshiba’s CT dose management technologies from the physicist’s perspective. This presentation will include an overview of Toshiba’s CT dose reduction technologies and dose safeguards. Content will include answers to frequently asked questions relating to dose management, dose tracking, CTDI measurement, ACR accreditation, ACR QC, and protocol review on Toshiba CT systems. Specific topics will include the following: Toshiba’s mechanism of tube current modulation; Exposure record format and interpretation of the values; Dose reporting and dose safeguard tools; Use of AIDR 3D iterative reconstruction; The configuration of task specific image quality target and its integration with AIDR 3D; Tips for scanning the ACR phantom with wide beam geometry; Measuring CTDI for wide beam geometry; Discussion of daily QC procedures and specifications; Tips for annual QC evaluation; Protocol management tools.

60 APPLIED LIFE SCIENCES↗

Zambia : long-term generation expansion study - executive summary.

The objective of this study is to analyze possible long-term development options of the Zambian electric power system in the period up to 2015. The analysis involved the hydro operations studies of the Zambezi river basin and the systems planning studies for the least-cost generation expansion planning. Two well-known and widely accepted computer models were used in the analysis: PC-VALORAGUA model for the hydro operations and optimization studies and the WASP-III Plus model for the optimization of long-term system development. The WASP-III Plus model is a part of the Argonne National Laboratory's Energy and Power Evaluation Model (ENPEP). The analysis was conducted in close collaboration with the Zambia Electricity Supply Corporation (ZESCO). On the initiative from The World Bank, the sponsor of the study, ZESCO formed a team of experts that participated in the analysis and were trained in the use of computer models. Both models were transferred to ZESCO free of charge and installed on several computers in the ZESCO corporate offices in Lusaka. In September-October 1995, two members of the ZESCO National Team participated in a 4-week training course at Argonne National Laboratory near Chicago, U.S.A., focusing on the long-term system expansion planning using the WASP and VALORAGUA models. The hydropower operations studies were performed for the whole Zambezi river basin, including the full installation of the Kariba power station, and the Cahora Bassa hydro power station in Mozambique. The analysis also included possible future projects such as Itezhi-Tezhi, Kafue Gorge Lower, and Batoka Gorge power stations. As hydropower operations studies served to determine the operational characteristics of the existing and future hydro power plants, it was necessary to simulate the whole Zambezi river basin in order to take into account all interactions and mutual influences between the hydro power plants. In addition, it allowed for the optimization of reservoir management and optimization of hydro cascades, resulting in the better utilization of available hydro potential. Numerous analyses were performed for different stages of system development. These include system configurations that correspond to years 1997, 2001, 2015 and 2020. Additional simulations were performed in order to determine the operational parameters of the three existing hydro power stations Victoria Falls, Kariba, and Kafue Gorge Upper, that correspond to the situation before and after their rehabilitation. The rehabilitation works for these three major power stations, that would bring their operational parameters and availability back to the design level, are planned to be carried out in the period until 2000. The main results of the hydro operations studies are presented in Table ES-1. These results correspond to VALORAGUA simulations of system configurations in the years 2001 and 2015. The minimum, average, and maximum electricity generation is based on the simulation of monthly water inflows that correspond to the chronological series of unregulated water inflows at each hydro profile in the period from April 1961 to March 1990. The recommended hydrology dataset provided in the Hydrology Report of the SADC Energy Project AAA 3.8 was used for this study.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Preliminary Findings from an Analysis of Building Energy Information System Technologies

Energy information systems comprise software, data acquisition hardware, and communication systems that are intended to provide energy information to building energy and facilities managers, financial managers, and utilities. This technology has been commercially available for over a decade, however recent advances in Internet and other information technology, and analytical features have expanded the number of product options that are available. For example, features such as green house gas tracking, configurable energy analyses and enhanced interoperability are becoming increasingly common. Energy information systems are used in a variety of commercial buildings operations and environments, and can be characterized in a number of ways. Basic elements of these systems include web-based energy monitoring, web-based energy management linked to controls, demand response, and enterprise energy management applications. However the sheer number and variety of available systems complicate the selection of products to match the needs of a given user. In response, a framework was developed to define the capabilities of different types of energy information systems, and was applied to characterize approximately 30 technologies. Measurement is a critical component in managing energy consumption and energy information must be shared at all organizational levels to maintain persistent, efficient operations. Energy information systems are important to understand because they offer the analytical support to process measured data into information, and they provide the informational link between the primary actors who impact building energy efficiency - operators, facilities and energy managers, owners and corporate decision makers. In this paper, preliminary findings are presented, with a focus on overall trends and the general state of the technology. Key conclusions include the need to further pursue standardization and usability, x-y plotting as an under-supported feature, and a general convergence of visualization and display capabilities.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Embedded Optical Sensing Systems For Distribution Transformer Monitoring

Traditional utility monitoring systems do not provide real-time visibility into the condition of transformers or accurate performance measurements. This has resulted in the use of lagging indicators, such as oil sample analysis, typically requiring expensive field visits, grid outages, and laboratory sample testing. This presentation reviews the use of optical sensing systems for managing transformers and improving grid resiliency and safety. The sensing systems allow direct internal monitoring of critical transformer components. Versatility covering different monitoring parameters of interest in embedded configurations for new transformers and a retrofittable configuration for older transformers is achieved by applying hair-thin multiplexed fiber-optic and other low-profile optical sensors in combination with a high-resolution optical readout and advanced analytics. Under an initiative funded by the DOE Office of Electricity, PARC, GE and Con Edison built, tested, and qualified commercial network transformers with embedded optical sensing systems. The parameters monitored were validated across a range of scenarios with lab instruments typically used for qualification testing. An ongoing field trial to demonstrate the robustness of the technology for remote monitoring through the industrial internet under demanding grid deployment conditions in New York City is showing promise toward scale-up of the technology. This presentation will provide an overview of the typical pain points in managing transformers and parameters for monitoring. It will also cover the requirements for highly constrained installations that need to have a larger capacity and flexible rating but that must fit into a tight space. The unique capabilities of optical sensing systems and a low-cost approach to interpreting the signals from sensors in transformers for predictive maintenance will be covered. The presentation will discuss the compatibility of the sensors in the transformer environment. It will discuss the validation testing per IEEE standards that enabled the solution to be implemented in field-deployable commercial transformers. The initial results from the field deployment and the potential for the technology to provide systematic alerts for unsafe/unexpected events will be discussed. The technology could enable utility professionals to gain information they can use to better plan for maintenance/management, and improve grid performance. This would in turn accommodate DERs and other evolving grid market dynamics.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Guiding Architects in Selecting Architectural Evolution Alternatives

Although there exist methods and tools to support architecture evolution, the derivation and evaluation of alternative evolution paths are realized manually. In this paper, we introduce an approach, where architecture specification is converted to a graph representation. Based on this representation, we automatically generate possible evolution paths, evalute quality attributes for different architecture configurations, and optimize the selection of a particular path accordingly. We illustrate our approach by modeling the software architecture evolution of a crisis management system.

99 GENERAL AND MISCELLANEOUS↗

pnnl/metagenomic_analysis

Metagenomic analysis is a computationally intensive task, this problem is compounded when many hundreds of samples need to be analyzed. We needed a program that would process the metagenomic sequencing data, manage computing resources, and combine the results into a unified output. We developed a script that prepares raw metagenomic sequencing data for analysis, configures analysis parameters, launches analysis jobs, keeps track of analysis progress, and combines analysis output. The analysis itself itself is done by the functionality provided by mothur (https://www.mothur.org/).

Avila, Andrew↗

Accelerator Transport Lattice Design Issues for High Performance ERLs

We will discuss issues in the design, construction, and operation of accelerator lattices for use in ERLs. These include phase space quality preservation during generation, acceleration, and transport of high-power, high-brightness beams, appropriate configuration of beam properties for synchrotron radiation users across a spectral range spanning THz to X-ray, beam handling during energy recovery, management of instabilities and "stray" power arising from the beam's coupling to itself and to environmental impedances and wakes, and provision for large acceptance (through the use of appropriate nonlinear optics) for the control of degraded "spent" beam and suppression of halo-driven beam loss. Experience derived from Jefferson Lab operation of five ERLs - across an energy range of 20 MeV to 1 GeV - will be described. Notice: Authored by Jefferson Science Associates, LLC under U.S. DOE Contract No. DE-AC05-06OR23177. The U.S. Government retains a non-exclusive, paid-up, irrevocable, world-wide license to publish or reproduce this manuscript for U.S. Government purposes.

Benson, Stephen↗

STARFIRE – Science and Technology Accelerated Research for Fusion Innovation and Reactor Engineering progress report

The STARFIRE hub leverages foundational science and technology (S&T) research and integrated plant modeling tools to advance Inertial Fusion Energy (IFE). S&T breakthroughs achieved in each thrust are incorporated into an integrated modeling tool to assess and prioritize remaining gaps to bridge for IFE to become viable. Scientific highlights span high-gain target design, diode-pumped solid-state lasers, and innovative target manufacturing. Key highlights include the investigation of shock propagation through various foam structures among other limiting factors of compression of IFE target, exploration of novel 3D printing techniques such as light-sheet additive manufacturing for 2-photon polymerization foams, and diode-pumped solid-state laser architectures required for several IFE approaches. In addition, the STARFIRE team has established two public-private working groups to address laser diode supply chain issues and test advanced laser diode configurations. Finally, a lite version of the integrated modeling tool has been developed to facilitate outreach and engage with private companies. STARFIRE’s management structure has been designed to ensure agile resource allocation, robust performance assessment, and alignment with the broader fusion energy mission. STARFIRE’s breakthroughs are disseminated to the community via reports, presentations, and publications, while agreements with private companies are set in place to protect proprietary information.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

DC-DC electrical transformer

An apparatus and corresponding systems and methods for managing electric power, particularly a transformer system and method, and more specifically a transformer for direct current. An example apparatus includes a chamber configured to contain plasma. The apparatus includes input electrodes disposed at least partially within the chamber, and configured to receive a first direct current input into the chamber. The input electrodes are configured to cause the input direct current to induce motion in the plasma. Motion induced in the plasma transforms current flowing there-through. At output electrodes extend from the chamber. The output electrodes conduct a second direct current, from the induced motion in the plasma, for delivery from the chamber.

Finn, John↗

TGC36 a dual purpose cask for the transport and interim storage of compacted waste (CSD-C)

According to contractual and international obligations, the German Utilities have to return the residues resulting from the reprocessing of nuclear fuel assemblies (compacted hulls and ends) to Germany. The new dual purpose cask TGC36 is a joint product from the two leading companies in the field development and manufactory of nuclear casks in Europe, GNS and TN International, is intended for the transport to the interim storage facility Ahaus and to be stored there for up several years. For the development and the delivery of the TGC36 cask, GNS and TN International formed the AGC Consortium based on German law to combine the special know how of both partners in the most efficient way. The design and the licensing strategy of the TGC36 are introduced in this paper. In conclusions: GNS and TNI have formed a consortium named AGC to design, license and manufacture an innovative cask for the transport and the interim storage of the compacted wastes resulting from the reprocessing of the German spent fuel. This cask has been optimized in order to offer a high capacity of loading, and allows a payload of 36 canisters, leading to a total mass of approximately 116 Mg in transport configuration. The success of this project requires a special effort from both partner companies, members of the consortium, and implies also an efficient management of simultaneous tasks during the licensing period and the manufacturing time of the first items of the cask. (authors)

42 ENGINEERING↗

Hydrophilic structures for condensation management in appliances

An appliance that includes a cabinet having an exterior surface; a refrigeration compartment located within the cabinet; and a hydrophilic structure disposed on the exterior surface. The hydrophilic structure is configured to spread condensation. The appliance further includes a wicking structure located in proximity to the hydrophilic structure, and the wicking structure is configured to receive the condensation.

42 ENGINEERING↗

Thermal Analysis of a Pipe Over-pack Container with a Combustible Waste Matrix for Los Alamos National Laboratory - 17307

Los Alamos National Laboratory (LANL) Technical Area 55 (TA 55) utilizes several different container types to store and transfer special nuclear material and waste for numerous programs. The Nuclear Process Infrastructure - Infrastructure Operations Group (NPI-2) analyzes and certifies containers to meet the specifications for distinct processes and storage. Engineering analysis performed on these containers include but are not limited to: leak testing, filter efficiency testing, pressure drop test, drop testing, water penetration testing, polymer (o-ring) hardness testing, and thermal steady state testing. Of all of these tests, thermal steady-state testing is most crucial to ensure critical components for specific containers do not fail under an internal heat payload. This testing provides data for setting heat payload limits for different containers. The Pipe Over-pack Container (POC) is a vented carbon steel container with a removable lid designed for storing or transferring nuclear waste. Additionally, TA 55 has been tasked to manage and store all of its Transuranic (TRU) waste for the foreseeable future. Being able to place more material into a single container conserves the physical storage space available at TA 55. The Pipe Over pack Handling and Operations Manual requires each user to ensure that the maximum temperature of each component in the POC is not exceeded. Conducting a thermal steady-state test with a combustible waste matrix on the POC can benefit stakeholders on increasing the material limits of the container. The results of these measurements will establish new wattage limits to meet LANL's transportation requirements. The current LANL Transportation Safety Document (TSD) limits the amount of heat source plutonium to 10 grams per POC, corresponding to approximately 5 Watts of heat. The result of this test was provided to the Packaging and Transportation (OS-PT) group to evaluate new wattage limits that can satisfy the needs of TA 55, while maintaining a safe packaging configuration. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗