Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Condition reports”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 541 records · Page 30

Nanomechanics and Electronic Structure of Organic Photovoltaics in Real Application Conditions by Advanced Scanning Probe Microscopy (Final Technical Report for Project DE-SC0018041)

This project report consists of the following three sections: A.) Investigation of Charge Transport Properties in Semiconducting Conjugated Polymer Blends Using Computational Chemistry and Experiments: This section provides unpublished but valuable research results that correlate the electronic structure of PCBM:PCDTBT organic photovoltaic systems with their current-voltage characteristics. The presentation is structured in the form of a scientific publication. B.) Scanning Probe Microscopy Methodology Development Efforts for Organic Photovoltaic Materials: This section summarizes various published works focusing on advancements in scanning probe microscopy methods. Each sub-section corresponds to a scientific publication for which the abstract and citation are provided. C.) Other Publications Supported by the Project: This section lists additional published works partially supported by the project, which are not included in the previous two sections.

36 MATERIALS SCIENCE↗

Development and Commercialization of Heavy-Duty Battery Electric Trucks Under Diverse Climate Conditions (DTNA EMG Innovation eCascadia 2.0 Final Technical Report)

During this project DTNA advanced heavy-duty transportation technologies to produce the eCascadia 2.0, a fully commercialized Class 7/8 electric tractor with the range and durability to meet the needs of 70% of freight movement in the United States. The eCascadia2.0 provides flexibility, operational performance, efficiency, and maintenance cost savings to the end user. The most direct outcome of this project is a commercially viable zero-emission heavy duty option with a 250-mile daily range and sufficient payload for regional haul duty cycles. The larger outcome is an acceleration of the market transformation away from petroleum-based fuels. DTNA’s comprehensive sales team, dealer network, customer network and maintenance and support teams will ensure that this is not a standalone zero-emission truck, but rather one that can be produced, marketed, and operated at scale to realize vast greenhouse gas and criteria pollutant emissions reductions, while also bringing zero emission vehicles closer to cost parity.

33 ADVANCED PROPULSION SYSTEMS↗

The influence of ice accretion physics on the forecasting of aircraft icing conditions

The physics which control aircraft ice accretion are reviewed in the context of identifying and forecasting hazardous icing conditions. The severity of aircraft icing is found to be extremely sensitive to temperature, liquid water content and droplet size distribution particularly near the transition between rime and mixed icing. The difficulty in measurement and the variability of these factors with altitude, position and time coupled with variable aircraft sensitivity make forecasting and identifying icing conditions difficult. Automated Pilot Reports (PIREPS) are suggested as one mechanism for improving the data base necessary to forecast icing conditions.

Hansman, R. John, Jr.↗

The influence of ice accretion physics on the forecasting of aircraft icing conditions

The physics which control aircraft ice accretion are reviewed in the context of identifying and forecasting hazardous icing conditions. The severity of aircraft icing is found to be extremely sensitive to temperature, liquid water content and droplet size distribution particularly near the transition between rime and mixed icing. The difficulty in measurement and the variability of these factors with altitude, position and time coupled with variable aircraft sensitivity make forecasting and identifying icing conditions difficult. Automated Pilot Reports (PIREPS) are suggested as one mechanism for improving the data base necessary to forecast icing conditions.

Hansman, R. John, Jr.↗

Investigations on the Stability, Oscillation, and Stress Conditions of Airplanes with Tab Control: First Partial Report. Derivation of the Equations of Motion and their General Solutions

For the design and the construction of airplanes the control is of special significance, not only with regard to the flight mechhnical properties but also for the proportional arrangement of wing unit, fuselage, and tail unit. whereas these problems may be regarded as solved for direct control of airplane motions, that is, for immediate operation of the control surfaces, they are not clarified as to oscimtions, stability, and stress phenomena occurring in flight motions with Indirect control, ss realized for instance in tab control. Its modus operandi is based on the activation of a tab hinged to the trailing edge & the main control surface. Due to lift and drag variations, mcments originate about the axis of rotation of the main contnol surface which cause an up-or--down floating of the main control surface and thus a change in the direction of the airplane. Since this tab control means flying with free control surface , the treatment of this problem should provide the basis on which to judge stability, oscilhtton, and stress data.The present report is to represent a contribution toward the clarification of the problems arising and, to treat the longitudinal motion of an airplane.

Filzek, B.↗

Stability of Cylindrical and Conical Shells of Circular Cross Section, with Simultaneous Action of Axial Compression and External Normal Pressure

We consider in this report the determination of the upper limit of critical loads in the case of simultaneous action of a compressive force, uniformly distributed over plane cross sections, and of isotropic external normal pressure on cylindrical or conical shells of circular cross section. As a starting point we use the differential equations for neutral equilibrium of conical shells which have been used for the solution of the problem of stability of conical shells under torsion and under axial compression; upon solution of the problem it is possible to satisfy all boundary conditions, in contrast to the report where no attention is paid to the fulfillment of the boundary conditions, and to the report where only part of the boundary conditions are satisfied by solution of the problem according to Galerkin's method. Approximate formulas are used for the determination of the critical external normal pressure with simultaneous action of longituninal compression. Let us note that the formulas suggested in reference 5 are not well founded and may lead, in a number of cases, to a substantial mistake in the magnitude of the critical load.

Mushtari, K. M.↗

Evaluation of the Shuttle remote manipulator

The objective initially proposed was to analyze shuttle remote manipulator (SRM) performance data collected during a Shuttle Flight. The data was to consist of video TRAC data collected via a video recorder. Unfortunately, the flight never collected the data due to higher priority experiments superseding it. As a result, the research team at Texas A&M was directed to work on several other pressing issues regarding the TRAC sensor. All but one of these issues were reported earlier in the form of periodic status reports. In fulfillment of the grant conditions, the last issue investigated is being reported as the final report. Ordinarily, a TRAC sensor determines the orientation of an object by analyzing the image reflected from a mirror target. The concern addressed is to develop a method for using the TRAC sensor when the target does not reflect a usable image.

Everett, Louis J.↗

Compatibility Assessment Tool

In support of ground system development for the Space Launch System (SLS), engineers are tasked with building immense engineering models of extreme complexity. The various systems require rigorous analysis of pneumatics, hydraulic, cryogenic, and hypergolic systems. There are certain standards that each of these systems must meet, in the form of pressure vessel system (PVS) certification reports. These reports can be hundreds of pages long, and require many hours to compile. Traditionally, each component is analyzed individually, often utilizing hand calculations in the design process. The objective of this opportunity is to perform these analyses in an integrated fashion with the parametric CADCAE environment. This allows for systems to be analyzed on an assembly level in a semi-automated fashion, which greatly improves accuracy and efficiency. To accomplish this, component specific parameters were stored in the Windchill database to individual Creo Parametric models based on spec control drawings. These parameters were then accessed by using the Prime Analysis within Creo Parametric. MathCAD Prime spreadsheets were created that automatically extracted these parameters, performed calculations, and generated reports. The reports described component compatibility based on local conditions such as pressure, temperature, density, and flow rates. The reports also determined component pairing compatibility, such as properly sizing relief valves with regulators. The reports stored the input conditions that were used to determine compatibility to increase traceability of component selection. The desired workflow for using this tool would begin with a Creo Schematics diagram of a PVS system. This schematic would store local conditions and locations of components. The schematic would then populate an assembly within Creo Parametric, using Windchill database parts. These parts would have their attributes already assigned, and the MathCAD spreadsheets could begin running through database parts to determine which components would be suited for specific locations within the assembly. This eliminates a significant amount of time from the design process, and makes initial analysis assessments more accurate. Each component that would be checked for a location within the assembly would generate a report, showing whether the component was compatible. These reports could be used to generate the PVS report without the need to perform the same analysis multiple times. This process also has the potential to be expanded upon to further automate PVS reports. The integration of software codes or macros could be used to automatically check through hundreds of parts for each location on the schematic. If the software could recognize which type of component would be necessary for each location, it is possible that simply starting the macro could completely choose all the components needed for the schematic, and in turn the system. This would save many hours of work initially selecting components, which could end up saving money. Overall, this process helps to automate initial component selections for PVS systems to fit local design specifications. These selections will automatically generate reports showing how the design criteria are met by the specific component that was chosen. These reports will contribute to easier compilation of the PVS certification reports, which currently take a great amount of time and effort to produce.

Egbert, James Allen↗

GeneLab: A Systems Biology Platform for Omics Analysis

NASA's GeneLab includes an open-access repository of some 200+ omics datasets generated by biological experiments relevant to spaceflight (including simulated cosmic radiation and microgravity). In order to maximize the intelligibility of these data, particularly for users with limited bioinformatics knowledge, GeneLab is now transforming the data in the repository into actual biological and physiological knowledge of the genetic and proteomic signatures found in these samples. This processed data is being derived by establishing standard data analysis workflows vetted by 114 scientists who are members of the four GeneLab Analysis Working Groups (Animal AWG, Plant AWG, Microbe AWG, Multi-Omics AWG). AWG members from institutes spanning the U.S. and four other countries participate on a voluntary basis. The AWGs meet monthly to discuss data mining, compare results and interpretations, and test forthcoming releases of the GeneLab Data Systems (GLDS). GLDS version 3.0 has been available to the general public since October 1st 2018, and has been providing a professional state-of-the-art bioinformatics platform for everyone in the space biology community to upload their data into a space biology omics data commons, to process their data with vetted standard workflows and to compare to existing analyses. The user interface for the platform is being designed to be accessible to a broad variety of users including those with limited bioinformatics experience, including high school and college students who can use it to learn about omics data analysis and space biology. As such, Genelab will constitute a powerful general public outreach capability of NASA and the Space Biology community at large. Data mining of the GeneLab database by the AWG has already started generating very interesting findings, including reports linking specific spaceflight conditions such as radiation, microgravity or carbon dioxide levels to molecular changes seen across various species. In this presentation, we will report on the current and future objectives for GeneLab, and review recent studies reported by the various AWGs relating molecular changes observed in various animal models and tissue with microgravity, radiation, circadian rhythm, hydration and carbon dioxide conditions.

Omics↗

GeneLab: A Systems Biology Platform for Omics Analysis: Disseminate and Reuse Data, Tools, and Samples Post-Project

NASA's GeneLab includes an open-access repository of some 200 plus omics datasets generated by biological experiments relevant to spaceflight (including simulated cosmic radiation and microgravity). In order to maximize the intelligibility of these data, particularly for users with limited bioinformatics knowledge, GeneLab is now transforming the data in the repository into actual biological and physiological knowledge of the genetic and proteomic signatures found in these samples. This processed data is being derived by establishing standard data analysis workflows vetted by 114 scientists who are members of the four GeneLab Analysis Working Groups (Animal AWG, Plant AWG, Microbe AWG, Multi-Omics AWG). AWG members from institutes spanning the U.S. and four other countries participate on a voluntary basis. The AWGs meet monthly to discuss data mining, compare results and interpretations, and test forthcoming releases of the GeneLab Data Systems (GLDS). GLDS version 3.0 has been available to the general public since October 1st 2018, and has been providing a professional state-of-the-art bioinformatics platform for everyone in the space biology community to upload their data into a space biology omics data commons, to process their data with vetted standard workflows and to compare to existing analyses. The user interface for the platform is being designed to be accessible to a broad variety of users including those with limited bioinformatics experience, including high school and college students who can use it to learn about omics data analysis and space biology. As such, Genelab will constitute a powerful general public outreach capability of NASA and the Space Biology community at large. Data mining of the GeneLab database by the AWG has already started generating very interesting findings, including reports linking specific spaceflight conditions such as radiation, microgravity or carbon dioxide levels to molecular changes seen across various species. In this presentation, we will report on the current and future objectives for GeneLab, and review recent studies reported by the various AWGs relating molecular changes observed in various animal models and tissue with microgravity, radiation, circadian rhythm, hydration and carbon dioxide conditions.

Omics↗

Effect of amine type on acidic toxic gas adsorption at ambient conditions on modified CuBTC

We report two amine-modified copper-based Metal Organic Frameworks (MOF (CuBTC)) of different surface chemical and textural features were synthesized and used as adsorbents of acidic toxic gases (NO 2 and H 2 S) in both moist (71% relative humidity (R.H.)) and dry conditions. The initial and exhausted samples were characterized by nitrogen adsorption, powder X-ray diffraction, scanning electron microscopy, thermal gravimetric analysis and Fourier transform infrared spectroscopy. The addition of melamine prevented full growth of CuBTC crystals and resulted in amorphous-like particles with sizes less than 200 nm. The material was non-porous with a small surface area. When urea was used as an amine source, the resulting particles maintained the overall octahedral shape of the parent CuBTC MOF and the material was more porous than the parent MOF. While the urea-modified CuBTC sample performed well as an NO 2 adsorbent in the presence of moisture, the reactivity of the melamine-modified sample and its physical properties provided a favorable environment for the removal of H 2 S. The incorporation of amines into the MOF structure also resulted in surface defects /open copper sites that favored the removal of toxic gases in dry conditions. The reactivity of the adsorbents with toxic gases was demonstrated by the changes in the adsorbent colors, in texture, and in surface chemistry (organic salts, complexes, sulfides and nitrates were formed).

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Tiltrotor Test Rig Wind-Tunnel Test Data Catalog

The Tiltrotor Test Rig (TTR) is a large-scale proprotor test system for the National Full-Scale Aerodynamics Complex (NFAC). The first wind-tunnel entry was completed in November 2018 with a modern, 26-ft diameter proprotor. The rotor tested was the Bell Model 699, an AW609 rotor modified specifically for wind-tunnel testing. The primary purpose was to complete the development of the TTR, including systems integration with the NFAC. Testing included axial flow up to 273 knots, conversion mode from 30 to 100 deg nacelle angle, and hover/vertical climb conditions. Additional testing included aerodynamic tares, motor tests, thermal tests, modal vibration tests, and other checkout activities. This report lists the test conditions achieved and the types of data acquired and saved in the database.

NFAC↗

Characterization and Analysis of the Energy-Reporting Accuracy of Connected Devices

Emerging energy-efficient building systems increasingly exhibit greater functionality, often requiring multiple operating modes (e.g. white-tunability for lighting products and data traffic for devices with networked, integrated sensors). This increased functionality makes energy consumption estimates more complex. Given that these functions consume energy, the energy performance of such building systems is dependent on what operating modes they use and how much time they spend in each mode. Devices and systems that can report their own energy consumption mitigate this energy-performance uncertainty. This study explores the energy-reporting accuracy of market-available connected electrical outlets. The study considers two residential-market products (five units each, one outlet per unit) and three commercial-market products (two units each, 18 to 24 outlets per unit) with the ability to report power drawn and/or energy consumed by devices connected to their receptacles. The products were purchased through typical market channels. Pacific Northwest National Laboratory (PNNL) conducted testing in December 2018 at its Connected Lighting Test Bed (CLTB), using a custom-developed test setup and method adapted from industry standards. The setup collected energy-consumption data reported by the outlet devices under test (DUTs) at one-minute intervals and compared that data with measurements taken by a reference meter over a range of test conditions. The residential products reported power draw but not interval or cumulative energy consumption. The commercial products reported both power draw and cumulative energy consumption. Relative reporting error (RRE) was calculated for all measurements, and analysis of the results revealed variations across devices and test conditions. The total number of measurements (50 for each residential product, 60 for each commercial product) offers an appreciable comparison of performance at the make/model level. The average RRE of the residential products derived from reported power draw was -0.02% and -1.20%. The average RRE for two of the three the commercial products derived from reported power draw was worse than those of the residential products (-2.40%, -2.72%, -0.36%). The internal integration of power over time, used to calculate cumulative energy consumption, typically occurs at current and voltage sampling rates much higher than once per minute. This suggests that the average commercial-product RRE derived from reported energy consumption should be very consistent and better than performance based on reported power draw. However, the RRE derived from reported energy consumption varied significantly across the three makes of commercial-market products and was uniformly less accurate than performance based on reported power draw. Subsequent analysis identified a number of root causes for this decrease in performance, most of which were related to reporting resolution. The goals of this study are to generate awareness of building systems capable of reporting their own energy consumption, further interest in the value of energy data for a variety of uses, draw attention to how the accuracy of reported metrics can be characterized, and quantify the performance variation found in marketavailable products. The results of this study and subsequent related work may be relevant to stakeholders in industry-specification and standards-development organizations. The methods this study employs could inform test and measurement procedures and performance classifications for connected outlets, lighting products, and other building systems capable of reporting their own energy consumption. The study concludes with stakeholder recommendations, including the following: • Energy-reporting device and system manufacturers developing products that report energy consumption should characterize the accuracy of reported metrics using a reference meter calibrated by an independent laboratory that was accredited by an ILAC MRA signatory (and whose scope of accreditation explicitly covers energy measurement), and should include this information on product data sheets. • Standards and specification development organizations should develop application-specific performance classifications that end users can understand and relate to their energy-data use needs (e.g., 2% accuracy class for utility streetlight energy billing needs, or 10% accuracy class for ESCO performance verification needs). • Current or potential owners, operators, and specifiers of energy-reporting building systems should rigorously analyze the dependency of current and planned energy-data use cases on accuracy, noting in particular the dependence (or lack thereof) on relative vs. absolute accuracy, and on trueness vs. precision (i.e., repeatability), and should communicate use-case needs to industry standards and specification organizations.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Characterization and Analysis of the Energy-Reporting Accuracy of Connected Devices

Emerging energy-efficient building systems increasingly exhibit greater functionality, often requiring multiple operating modes (e.g. white-tunability for lighting products and data traffic for devices with networked, integrated sensors). This increased functionality makes energy consumption estimates more complex. Given that these functions consume energy, the energy performance of such building systems is dependent on what operating modes they use and how much time they spend in each mode. Devices and systems that can report their own energy consumption mitigate this energy-performance uncertainty. This study explores the energy-reporting accuracy of market-available connected electrical outlets. The study considers two residential-market products (five units each, one outlet per unit) and three commercial-market products (two units each, 18 to 24 outlets per unit) with the ability to report power drawn and/or energy consumed by devices connected to their receptacles. The products were purchased through typical market channels. Pacific Northwest National Laboratory (PNNL) conducted testing in December 2018 at its Connected Lighting Test Bed (CLTB), using a custom-developed test setup and method adapted from industry standards. The setup collected energy-consumption data reported by the outlet devices under test (DUTs) at one-minute intervals and compared that data with measurements taken by a reference meter over a range of test conditions. The residential products reported power draw but not interval or cumulative energy consumption. The commercial products reported both power draw and cumulative energy consumption. Relative reporting error (RRE) was calculated for all measurements, and analysis of the results revealed variations across devices and test conditions. The total number of measurements (50 for each residential product, 60 for each commercial product) offers an appreciable comparison of performance at the make/model level. The average RRE of the residential products derived from reported power draw was -0.02% and -1.20%. The average RRE for two of the three the commercial products derived from reported power draw was worse than those of the residential products (-2.40%, -2.72%, -0.36%). The internal integration of power over time, used to calculate cumulative energy consumption, typically occurs at current and voltage sampling rates much higher than once per minute. This suggests that the average commercial-product RRE derived from reported energy consumption should be very consistent and better than performance based on reported power draw. However, the RRE derived from reported energy consumption varied significantly across the three makes of commercial-market products and was uniformly less accurate than performance based on reported power draw. Subsequent analysis identified a number of root causes for this decrease in performance, most of which were related to reporting resolution. The goals of this study are to generate awareness of building systems capable of reporting their own energy consumption, further interest in the value of energy data for a variety of uses, draw attention to how the accuracy of reported metrics can be characterized, and quantify the performance variation found in marketavailable products. The results of this study and subsequent related work may be relevant to stakeholders in industry-specification and standards-development organizations. The methods this study employs could inform test and measurement procedures and performance classifications for connected outlets, lighting products, and other building systems capable of reporting their own energy consumption. The study concludes with stakeholder recommendations, including the following: • Energy-reporting device and system manufacturers developing products that report energy consumption should characterize the accuracy of reported metrics using a reference meter calibrated by an independent laboratory that was accredited by an ILAC MRA signatory (and whose scope of accreditation explicitly covers energy measurement), and should include this information on product data sheets. • Standards and specification development organizations should develop application-specific performance classifications that end users can understand and relate to their energy-data use needs (e.g., 2% accuracy class for utility streetlight energy billing needs, or 10% accuracy class for ESCO performance verification needs). • Current or potential owners, operators, and specifiers of energy-reporting building systems should rigorously analyze the dependency of current and planned energy-data use cases on accuracy, noting in particular the dependence (or lack thereof) on relative vs. absolute accuracy, and on trueness vs. precision (i.e., repeatability), and should communicate use-case needs to industry standards and specification organizations.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Process Anomaly Detection for Sparsely Labeled Events in Nuclear Power Plants

An essential aspect of online monitoring, subtle anomaly detection increases the detection lead time for equipment failure and enables a nuclear power plant (NPP) to mitigate unexpected partial or full outages, resulting in significant cost saving to the plant. Once an anomaly is detected by plant staff, its cause and severity are investigated. Because the vast majority of anomalies require some level of investigation, including some that require time-consuming examination, before they are passed over to the engineering organization for further analysis, plants are often equipped with tools to assist the staff in performing anomaly detection. Those tools operate as a black box and are often based on statistical methods that establish sensor correlations using preconfigured mathematical models and flag correlation deviations as anomalies. Due to the number of anomalies detected at a given NPP on a daily basis, a significant number of flagged anomalies usually await examination for days or weeks. A primary cause of this backlog is that the methods used by the tools generate many false positives. Though this is usually attributed to oversensitive model settings due to very narrow normal operation bands, it can also be associated with the model development being inadequate for the process being monitored, or with missing model inputs that could have explained misclassified positives. The performance of anomaly detection tools impacts their plant acceptance and utilization, especially when the effort to address false positives generated by the tool depletes the value or cost saved by using that tool. Thus, means to advance anomaly detection performance have been investigated by the Department of Energy’s Light Water Reactor Sustainability program. Previous and ongoing efforts have targeted unsupervised machine-learning (ML) methods, which do not require the labeling of any data fed into the ML model. By contrast, in supervised anomaly detection methods, every data point is labeled as either a normal or abnormal process condition, and the model is trained to replicate the classification process. Supervised methods usually outperform unsupervised methods, due to the added value in differentiating normal from anomalous states of the monitored process. An NPP’s corrective action program requires it to track and document, via a dedicated report, the resolution of any issues that occur within the plant. Once created, each report is reviewed by a plant screening committee, and several classifications and decisions are made. Recently, a collaborating NPP developed an artificial intelligence and ML-based classifier to categorize a condition report (CR) into classes that can serve to label the data as normal or anomalous. Applying CRs as labels represents a semi-supervised use case. Semi-supervised ML assumes that labels exist for some data points (i.e., labeled anomalies, in this case) but not for the rest. In this effort, semi-supervised ML methods were used to fuse data from CRs with anomaly detection methods in order to test the hypothesis that partially labeled anomalies would improve the accuracy of the anomaly detection methods. Specifically, two methods were used. The first is the deep Semi-supervised Anomaly Detection (deep SAD) method, which can handle labels ranging from fully unsupervised to fully supervised cases. The second is a newly designed ML method developed specifically for this effort and referred to as the high-order feature (HOF)-based method. To evaluate these two methods in controlled environments, synthetic data generators were developed and used. The first datasets used a spring-mass-damper (SMD) system simulator commonly found in mechanical engineering references. This was used to create two use cases: a one- and a three-mass system. Anomalies were introduced by changing the spring and damper coefficients while the system was actuated by random forces. The second datasets used the commercial Dymola-Modelica software to build a simplified nuclear reactor model. Anomalies were added in the form of corrupted sensor readings and/or control commands. The deep SAD method was tested using the SMD system, while the HOF method was tested using both datasets. Application of the deep SAD semi-supervised ML method demonstrated that labels can generate increased confidence in detecting true anomalies. This helped increase the number of true positives and decrease the number of false negatives—something that would aid in addressing the backlog of possible anomalies. Application of the HOF method demonstrated that labels can aid in down selecting from a candidate set of features to a more optimal subset in order to better differentiate between normal and anomalous conditions.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Social Disparities of Pain and Pain Intensity Among Women Diagnosed With Early Stage Breast Cancer

Background: Breast cancer is one of the most commonly diagnosed cancers among women in the United States and pain is the most common side effect of breast cancer and its treatment. Yet, the relationships between social determinants of pain and pain experience/intensity remain under-investigated. We examined the associations between social determinants of pain both at the individual level and the neighborhood level to understand how social conditions are associated with pain perception among early stage breast cancer patients. Methods: We conducted integrated statistical analysis of 1,191 women with early stage breast cancer treated at a large cancer center in Memphis, Tennessee. Combining electronic health records, patient-reported data and census data regarding residential address at the time of first diagnosis, we evaluated the relationships between social determinants and pain perception. Pain responses were self-reported by a patient as a numerical rating scale score at the patient’s initial diagnosis and follow-up clinical visits. We implemented two sets of statistical analyses of the zero-inflated Poisson model and estimated the associations between neighborhood poverty prevalence and breast cancer pain intensity. After adjustment for demographic characteristics, cancer stage, and chemotherapy, pain perception was significantly associated with poverty and blight level of the neighborhood. Results: Among women living in the highest-poverty areas, the odds of reporting pain were 2.48 times higher than those in the lowest-poverty area. Women living in the highest-blight area had 5.43 times higher odds of reporting pain than those in the lowest-blight area. Neighborhood-level social determinants were significantly associated with pain intensity among women diagnosed with early-stage breast cancer. Conclusions: Distressed neighborhood conditions are significantly associated with higher pain perception. Breast cancer patients living in socio-economically disadvantaged neighborhoods and in poor environmental conditions reported higher pain severity compared to patients from less distressed neighborhoods. Therefore, post-diagnosis pain treatment design needs to be tailored to the social determinants of the breast cancer patients.

60 APPLIED LIFE SCIENCES↗

Workload and strategic adaptation under transformations of visual-coordinative mappings

A study involving a bimanual pursuit-tracking task is conducted to examine strategic exploration of differing visual and motor coordination patterns emphasizing workload as an indicator of strategic behavior. The mappings are conducted for 16 possible variations of order, speed, and combination. Performance is assessed by means of the rms and percent time-on-target, and the NASA task-load index is used to classify subjective reports on workload. The results are broken down into four primary performance mappings and four hybrid mappings called contradictory conditions. The order of difficulty of the conditions is apparently determined by the workload, except that in the case of the three most difficult decoupled conditions some dissociation is reported.

Caird, J. K.↗