Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Change detection”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 541 records · Page 30

Coherent Laser Instrument Would Measure Range and Velocity

A proposed instrument would project a narrow laser beam that would be frequency-modulated with a pseudorandom noise (PN) code for simultaneous measurement of range and velocity along the beam. The instrument performs these functions in a low mass, power, and volume package using a novel combination of established techniques. Originally intended as a low resource- footprint guidance sensor for descent and landing of small spacecraft onto Mars or small bodies (e.g., asteroids), the basic instrument concept also lends itself well to a similar application guiding aircraft (especially, small unmanned aircraft), and to such other applications as ranging of topographical features and measuring velocities of airborne light-scattering particles as wind indicators. Several key features of the instrument s design contribute to its favorable performance and resource-consumption characteristics. A laser beam is intrinsically much narrower (for the same exit aperture telescope or antenna) than a radar beam, eliminating the need to correct for the effect of sloping terrain over the beam width, as is the case with radar. Furthermore, the use of continuous-wave (CW), erbium-doped fiber lasers with excellent spectral purity (narrow line width) permits greater velocity resolution, while reducing the laser s power requirement compared to a more typical pulsed solid-state laser. The use of CW also takes proper advantage of the increased sensitivity of coherent detection, necessary in the first place for direct measurement of velocity using the Doppler effect. However, measuring range with a CW beam requires modulation to "tag" portions of it for time-of-flight determination; typically, the modulation consists of a PN code. A novel element of the instrument s design is the use of frequency modulation (FM) to accomplish both the PN-modulation and the Doppler-bias frequency shift necessary for signed velocity measurements. This permits the use of a single low-power waveguide electrooptic phase modulator, while simultaneously mitigating the effects of speckle as a noise source in the coherent detection.

Chang, Daniel↗

Detection of emetic activity in the cat by monitoring venous pressure and audio signals

To investigate the use of audio signals as a simple, noninvasive measure of emetic activity, the relationship between the somatic events and sounds associated with retching and vomiting was studied. Thoracic venous pressure obtained from an implanted external jugular catheter was shown to provide a precise measure of the somatic events associated with retching and vomiting. Changes in thoracic venous pressure monitored through an indwelling external jugular catheter with audio signals, obtained from a microphone located above the animal in a test chamber, were compared. In addition, two independent observers visually monitored emetic episodes. Retching and vomiting were induced by injection of xylazine (0.66mg/kg s.c.), or by motion. A unique audio signal at a frequency of approximately 250 Hz is produced at the time of the negative thoracic venous pressure change associated with retching. Sounds with higher frequencies (around 2500 Hz) occur in conjunction with the positive pressure changes associated with vomiting. These specific signals could be discriminated reliably by individuals reviewing the audio recordings of the sessions. Retching and those emetic episodes associated with positive venous pressure changes were detected accurately by audio monitoring, with 90 percent of retches and 100 percent of emetic episodes correctly identified. Retching was detected more accurately (p is less than .05) by audio monitoring than by direct visual observation. However, with visual observation a few incidents in which stomach contents were expelled in the absence of positive pressure changes or detectable sounds were identified. These data suggest that in emetic situations, the expulsion of stomach contents may be accomplished by more than one neuromuscular system and that audio signals can be used to detect emetic episodes associated with thoracic venous pressure changes.

A Nagahara↗

Assessment of Vegetation Stress Using Reflectance or Fluorescence Measurements

Current methods for large-scale vegetation monitoring rely on multispectral remote sensing, which has serious limitation for the detection of vegetation stress. To contribute to the establishment of a generalized spectral approach for vegetation stress detection, this study compares the ability of high-spectral resolution reflectance (R) and fluorescence (F) foliar measurements to detect vegetation changes associated with common environmental factors affecting plant growth and productivity. To obtain a spectral dataset from a broad range of species and stress conditions, plant material from three experiments was examined, including (i) corn, nitrogen (N) deficiency/excess; (ii) soybean, elevated carbon dioxide, and ozone levels; and (iii) red maple, augmented ultraviolet irradiation. Fluorescence and R spectra (400-800 nm) were measured on the same foliar samples in conjunction with photosynthetic pigments, carbon, and N content For separation of a wide range of treatment levels, hyperspectral (5-10 nm) R indices were superior compared with F or broadband R indices, with the derivative parameters optimal results. For the detection of changes in vegetation physiology, hyperspectral indices can provide a significant improvement over broadband indices. The relationship of treatment levels to R was linear, whereas that to F was curvilinear. Using reflectance measurements, it was not possible to identify the unstressed vegetation condition, which was accomplished in all three experiments using F indices. Large-scale monitoring of vegetation condition and the detection of vegetation stress could be improved by using hyperspectral R and F information, a possible strategy for future remote sensing missions.

Campbell, P. K. E.↗

Instrument characterization for the detection of long-term changes in stratospheric ozone - An analysis of the SBUV/2 radiometer

The scientific objective of unambiguously detecting subtle global trends in upper stratospheric ozone requires that one maintains a thorough understanding of the satellite-based remote sensors intended for this task. The instrument now in use for long term ozone monitoring is the SBUV/2 being flown on NOAA operational satellites. A critical activity in the data interpretation involves separating small changes in measurement sensitivity from true atmospheric variability. By defining the specific issues that must be addressed and presenting results derived early in the mission of the first SBUV/2 flight model, this work serves as a guide to the instrument investigations that are essential in the attempt to detect long-term changes in the ozone layer.

Frederick, J. E.↗

Measurement and Interpretation of Temporal Variations of the Earths Gravity Field Using GPS and SLR Data

This investigation has had four main thrusts: 1) The analysis of seasonal variations of the Earth's gravitational field using Lageos 1 and 2 SLR data and comparisons to geophysical models. We have estimated the annual variation of the gravity field via a spherical harmonic expansion complete to degree and order 4. We have also constructed a similar model using models of the annual variation in the gravity field due to atmospheric, hydrologic, and ocean mass redistribution. These three models, when combined together, are in excellent agreement with the variations observed by satellite laser ranging. An article on these results was published in the journal Geophysical Research Letters. 2) The second thrust of our investigation has been to analyze the output of a Global Climate Model (GCM) to determine if the GRACE gravity mission can be expected to detect climate change signals. Working with Gary Russell at the Goddard Institute for Space Studies (GISS), we have determined that there are several large secular signals that GRACE might be able to detect, including secular changes in snow cover, sea ice, polar ice, ocean mass, and other variables. It is possible that some of these signals could be detected with 5 years of GRACE measurements - its hard to judge this because the interannual variability in the GCM, which could mask the climate signals, is unreliable. Certainly a follow-on GRACE mission could detect these signals when compared to the data from the initial GRACE mission.). An article on these results will be published in the journal Journal of Geophysical Research. 3) In the last year of the investigation, we developed a new technique for analyzing temporal gravity variations using "geophysical fingerprints", which was successfully demonstrated on 20 years of satellite laser ranging data [Nerem et al., 20031. 4]. We also participated in a workshop on future satellite gravity measurements, which resulted in paper on measuring ocean mass variations using GRACE [Nerem et al., 20031 and on using laser interferometry for future gravity missions [Bender et al., 20031].

Nerem, R. Steven↗

Probable detection of climatically significant change of the solar constant

It is suggested that the decrease in the solar radius inferred from solar eclipse observations made from 1715 to 1979 reflects a variation of the solar constant that may be of considerable climatic significance. A general, time-averaged relationship between changes in the solar constant and changes in the solar radius is derived based on a model of the contraction and expansion of the convective zone. A preliminary numerical calculation of radius changes due to changes in the mixing length of the solar envelope is presented which indicates that a decrease in solar radius of 0.5 arcsec, as observed in the last 264 years, would correspond to a decrease of 0.7% in the solar constant, a value of large climatic significance. Limitations of the observational method and the numerical approach are pointed out, and required additional theoretical and observational efforts are indicated.

Sofia, S.↗

Effect of 16-Day Spaceflight on the Morphology of Thick-Toed Geckos (Pachydactylus Bibronii Smith, 1846)

There are grounds to believe that space flown experiments on thick-toed geckos may help solve the problem of floatation of vertebrates in microgravity. Geckos of this species carry on the lower surface of their toes numerous setae, which allow them to remain attached to any surfaces regardless of the gravitational effects. Experiments were performed on 5 animals in each of the following groups: flight, basal, synchronous and laboratory controls. 32 hours after a 16- day flight the animals were euthanazed and examined using traditional histology and X-ray microtomography. Body mass losses were 10% in the flight animals, 7.4% in the synchronous controls, and 12.3% in the laboratory controls. Since the flight and synchronous animals were kept at 15-19 C, whereas the laboratory controls - at 26-28 C, it can be inferred that environmental temperatures impacted animal metabolism no less than flight induced stress. Blood tests of the flown animals showed a 12% decrease of erythrocytes and a 40% decrease of dark-nuclear granulocytes, with the number of light-nuclear granulocytes remaining unchanged. In the small intestine the number of goblet cells increased allowing them to occupy a large portion of the cyptal surface. Enhanced secretion was accompanied by the appearance of dead intestinal cells in the lumen. Clusters of degraded hepatocytes were found at the liver edges of flight animals. Signs of liver involution were similar to the changes produced by alcohol consumption but did not spread to its central part. In the heart, insignificant hypertrophy and excessive blood supply that still remained within the physiological norm were detected. No significant changes were found in the pancreas, lungs, nervous systems or the snouts of the flown animals, but the volume of their gallbladders was greater than in controls. The epithelium of toe pads of the flight animals became thinner. Histological examination of the humerus did not demonstrate significant mineral losses. However, X-ray microtomography showed changes in the trabecular structure in the subepyphyseal zone of bones in flight animals compared to the controls. In summary, all the changes detected in the flight animals were adaptive. Therefore, geckos of this species can be used as an animal model for morphological studies in longer-duration space flights.

Gulimova, V. I.↗

Utilization of ERTS-1 data in the Houston area

The author has identified the following significant results. Using clustering techniques, several large lakes in Texas have been accurately delineated in computer printout graymaps. It was also found that small bodies of water (one to two acres in size) could be detected by searching for small reflectance values in the infrared data. A graymap printout of a lake described a shore outline that was not consistent with available maps. Field examination revealed that the actual level of the lake was below that for which the map was drawn. The current lake configuration agrees in shape and relative size with the ERTS-1 data printout. Water turbidity causes reflectance changes which are detectable in ERTS-1 band 7 data. A comparison has been made of the Monterey Bay, California area using 1971 aerial color infrared photography and a 1972 ERTS-1 band 7 infrared image. This comparison revealed that some event has occurred to impound a significant amount of water in the area since the infrared photography was taken. Data values in the ERTS-1 infrared image exhibit detectable changes in brightness at inflow points, where high turbidity would be present. Researchers had not expected to detect water turbidity patterns in band 7 (800 to 1100 nanometers).

Erb, R. B.↗

Methods of DNA methylation detection

The present invention provides for methods of DNA methylation detection. The present invention provides for methods of generating and detecting specific electronic signals that report the methylation status of targeted DNA molecules in biological samples.Two methods are described, direct and indirect detection of methylated DNA molecules in a nano transistor based device. In the direct detection, methylated target DNA molecules are captured on the sensing surface resulting in changes in the electrical properties of a nano transistor. These changes generate detectable electronic signals. In the indirect detection, antibody-DNA conjugates are used to identify methylated DNA molecules. RNA signal molecules are generated through an in vitro transcription process. These RNA molecules are captured on the sensing surface change the electrical properties of nano transistor thereby generating detectable electronic signals.

Maki, Wusi Chen↗

Landsat-8 Operational Land Imager On-Orbit Radiometric Calibration

The Operational Land Imager (OLI), the VIS/NIR/SWIR sensor on the Landsat-8 has been successfully acquiring Earth Imagery for more than four years. The OLI incorporates two on-board radiometric calibration systems, one diffuser based and one lamp based, each with multiple sources. For each system one source is treated as primary and used frequently and the other source(s) are used less frequently to assist in tracking any degradation in the primary sources. In addition, via a spacecraft maneuver, the OLI instrument views the moon once a lunar cycle (approx. 29 days). The integrated lunar irradiances from these acquisitions are compared to the output of a lunar irradiance model. The results from all these techniques, combined with cross calibrations with other sensors and ground based vicarious measurements are used to monitor the OLI's stability and correct for any changes observed. To date, the various techniques have other detected significant changes in the shortest wavelength OLI band centered at 443 nm and these are currently being adjusted in the operational processing.

radiometric calibratio↗

The broad emission line and continuum variations of Seyfert galaxies. 2: Broad-line region structure and kinematics

Spectroscopic observations of 13 Seyfert 1 galaxies made from 1979 to 1984 at Palomar and Steward Observatories were analyzed for H beta line profile variations. Significant profile changes were detected in five galaxies. These variations are often associated with changes in continuum and/or H beta strength, suggesting a causal connection between variations in the continuum source and changes in emission-line profiles. Moreover, the overall strength of H beta line flux variations is strongly correlated with line width in the far wings, whereas no such correlation was found in the line core. This finding is consistent with previous observations (Shuder 1982) which suggest that higher velocity gas lies closer to the central continuum source, since this inner gas would be expected to track variations more closely. In each of the five galaxies in which H beta line profile variations were detected, particularly NGC 5548 and Mrk 6, only two distinct line profile shapes were observed. Since intermediate profile types were not detected, the transition from one type to the other must occur rapidly (within a few months). These rapid line profile variations are thus consistent with numerous other studies which strongly point to a small broad-line region (BLR) size in Seyfert galaxies. Observational models of BLR kinematics and structure for each of the galaxies in the present sample are presented. Line asymmetries suggest that radial motions exist in the BLRs of most of these objects. Chaotic motions also appear to be quite common. However, evidence for rotational motion was observed in only one case. A model that is consistent with the majority of this sample incorporates both radial and chaotic motions combined with some form of external obscuration such as an optically and geometrically thick torus.

Rosenblatt, Edward I.↗

Land use mapping and modelling for the Phoenix Quadrangle

The author has identified the following significant results. The land use of the Phoenix Quadrangle in Arizona had been mapped previously from aerial photographs and recorded in a computer data bank. During the ERTS-1 experiment, changes in land use were detected using only the ERTS-1 images. The I2S color additive viewer was used as the principal image enhancement tool, operated in a multispectral mode. Hard copy color composite images of the best multiband combinations from ERTS-1 were made by photographic and diazo processes. The I2S viewer was also used to enhance changes between successive images by quick flip techniques or by registering with different color filters. More recently, a Bausch and Lomb zoom transferscope has been used for the same purpose. Improved interpretation of land use change resulted, and a map of changes within the Phoenix Quadrangle was compiled. The first level of a proposed standard land use classification system was sucessfully used. ERTS-1 underflight photography was used to check the accuracy of the ERTS-1 image interpretation. It was found that the total areas of change detected in the photos were comparable with the total areas of change detected in the ERTS-1 images.

Place, J. L.↗

Recent Aeolian Dune Change on Mars

Previous comparisons of Martian aeolian dunes in satellite images have not detected any change in dune form or position. Here, we show dome dunes in the north polar region that shrank and then disappeared over a period of 3.04 Mars years (5.7 Earth years), while larger, neighboring dunes showed no erosion or movement. The removal of sand from these dunes indicates that not only is the threshold wind speed for saltation exceeded under present conditions on Mars, but that any sand that is available for transport is likely to be moved. Dunes that show no evidence of change could be crusted, indurated. or subject to infrequent episodes of movement.

Bourke, M. C.↗

Detection of short-term changes in vegetation cover by use of LANDSAT imagery

The author has identified the following significant results. By using a constant band 6 to band 5 radiance ratio of 1.25, the changing pattern of areas of relatively dense vegetation cover was detected for the semiarid region in the vicinity of Tucson, Arizona. Electronically produced binary thematic masks were used to map areas with dense vegetation. The foliar cover threshold represented by the ratio was not accurately determined but field measurements show that the threshold lies in the range of 10 to 25 percent foliage cover. Montana evergreen forests with constant dense cover were correctly shown to exceed the threshold on all dates. The summer active grassland exceeded the threshold in the summer unless rainfall was insufficient. Desert areas exceeded the threshold during the spring of 1973 following heavy rains; the same areas during the rainless spring of 1974 did not exceed threshold. Irrigated fields, parks, golf courses, and riparian communities were among the habitats most frequently surpassing the threshold.

Turner, R. M.↗

Integrated atmosphere revitalization system description and test results

The design and operation of several air revitalization subsystems are described, along with the testing of these subsystems separately and integrated in an air revitalization system for use in space stations. The subsystems are: one that generates O2 by water electrolysis, one that removes and concentrates CO2 using an electrochemical technique, and one that reduces concentrated CO2 by the Sabatier process. Results of the integrated testing include the observations that liquid cooling should be baselined for recovery of the CO2 reduction subsystem product water, continuous CO2 injection into the air supply unit is preferable, small changes in the current CO2 removal subsystem inlet PCO2 are detectable as changes in the CO2 reduction subsystem reactor temperatures, and hardwired shutdown of critical parameters is vital if computer-based controllers are not redundant. Several block diagrams are provided.

Martin, R. B.↗

The RR Lyrae variables in the globular cluster M68

New observations, made with the Helen Sawyer Hogg telescope at Las Campanas, have been analyzed in a search for double-mode pulsators (RRd stars) in the metal-poor globular cluster, Messier 68. Of the 30 stars studied, nine have been identified as RRd stars; V33, which exhibited the characteristics of an RRd star in 1950, now appears to be an RRc star. Reliable periods and period ratios have been determined for six of the RRd stars. Masses for these RRd stars, calculated from fitting formulas given by Kovacs et al. (1991), range from 0.75 to 0.90 solar mass, depending on the assumed luminosity and metal abundance. These masses are in the same range as those for the RRd stars in M 15, whose RRd sample resembles that of M68 very closely. Fourier parameters determined for the light curves of the M68 variables show that the RRc stars in the two clusters are also very similar. In particular, on the plot of phase parameter phi sub 31 with period, the M15 and M68 RRc samples are virtually indistinguishable. A comparison of the new M68 observations with observations made 40 yr ago shows that the periods of some of the stars have changed, but the 40 yr interval is too short for detecting period changes caused by evolutionary effects.

Clement, Christine M.↗

Ion-Atom Cold Collisions and Atomic Clocks

Collisions between ultracold neutral atoms have for some time been the subject of investigation, initially with hydrogen and more recently with laser cooled alkali atoms. Advances in laser cooling and trapping of neutral atoms in a Magneto-Optic Trap (MOT) have made cold atoms available as the starting point for many laser cooled atomic physics investigations. The most spectacularly successful of these, the observation of Bose-Einstein Condensation (BEC) in a dilute ultra-cold spin polarized atomic vapor, has accelerated the study of cold collisions. Experimental and theoretical studies of BEC and the long range interaction between cold alkali atoms is at the boundary of atomic and low temperature physics. Such studies have been difficult and would not have been possible without the development and advancement of laser cooling and trapping of neutral atoms. By contrast, ion-atom interactions at low temperature, also very difficult to study prior to modern day laser cooling, have remained largely unexplored. But now, many laboratories worldwide have almost routine access to cold neutral atoms. The combined technologies of ion trapping, together with laser cooling of neutrals has made these studies experimentally feasible and several very important, novel applications might come out of such investigations . This paper is an investigation of ion-atom interactions in the cold and ultra-cold temperature regime. Some of the collisional ion-atom interactions present at room temperature are very much reduced in the low temperature regime. Reaction rates for charge transfer between unlike atoms, A + B(+) approaches A(+) + B, are expected to fall rapidly with temperature, approximately as T(sup 5/2). Thus, cold mixtures of atoms and ions are expected to coexist for very long times, unlike room temperature mixtures of the same ion-atom combination. Thus, it seems feasible to cool ions via collisions with laser cooled atoms. Many of the conventional collisional interactions, exploited as a useful tool at room temperature and higher, are greatly enhanced at low energy. For example, collisional spin transfer from one species of polarized atoms to another has long been a useful method for polarizing a sample of atoms where no other means was available. Because optical pumping cannot be used to polarize the nuclear spin of Xe-129 or He-3 (for use in nmr imaging of the lungs), the nuclear spins are polarized via collisions with an optically pumped Rb vapor in a cell containing both gases. In another case, a spin polarized thermal Cs beam was used to polarize the hyperfine states of trapped He(+)-3 ions in order to measure their hyperfine clock transition frequency. The absence of an x-ray light source to optically pump the ground state of the He(+)-3 ion necessitated this alternative state preparation. Similarly, Cd(+) and Sr(+) ions were spin-oriented via collisions in a cell with optically pumped Rb vapor. Resonant RF spin changing transitions in the ground state of the ions were detected by changes in the Rb resonance light absorption. Because cold collision spin exchange rates scale with temperature as T(sup -1/2) this technique is expected to be a far more powerful tool than the room temperature counterpart. This factor of 100 or more enhancement in spin exchange reaction rates at low temperatures is the basis for a novel trapped ion clock where laser cooled neutrals will cool, state select and monitor the ion clock transition. The advantage over conventional direct laser cooling of trapped ions is that the very expensive and cumbersome UV laser light sources, required to excite the ionic cooling transition, are effectively replaced by simple diode lasers.

Prestage, John D.↗