Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Certified”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 541 records · Page 30

Simultaneous spin-coating and solvent annealing: Manipulating the active layer morphology to a power conversion efficiency of 9.6% in polymer solar cells

Here, we developed a simultaneous spin-coating/solvent-annealing process and demonstrated morphology optimization for PTB7 based organic photovoltaics. This novel processing method enhances the edge-on crystalline content in thin films and induces the formation of weak PCBM aggregates. As a result, the efficiency of polymer solar cells increased from 9.2% to a certified high efficiency of 9.61%, owing to an enhanced short-circuit current (J sc , 18.4 mA cm –2 vs. 17. 5 mA cm –2 ) and an improved fill factor.

36 MATERIALS SCIENCE↗

An interface stabilized perovskite solar cell with high stabilized efficiency and low voltage loss

Stabilization of the crystal phase of inorganic/organic lead halide perovskites is critical for their high performance optoelectronic devices. However, due to the highly ionic nature of perovskite crystals, even phase stabilized polycrystalline perovskites can undergo undesirable phase transitions when exposed to a destabilizing environment. While various surface passivating agents have been developed to improve the device performance of perovskite solar cells, conventional deposition methods using a protic polar solvent, mainly isopropyl alcohol (IPA), results in a destabilization of the underlying perovskite layer and an undesirable degradation of device properties. We demonstrate the hidden role of IPA in surface treatments and develop a strategy in which the passivating agent is deposited without destabilizing the high quality perovskite underlayer. This strategy maximizes and stabilizes device performance by suppressing the formation of the perovskite δ-phase and amorphous phase during surface treatment, which is observed using conventional methods. Our strategy also effectively passivates surface and grain boundary defects, minimizing non-radiative recombination sites, and preventing carrier quenching at the perovskite interface. This results in an open-circuit-voltage loss of only ~340 mV, a champion device with a power conversion efficiency of 23.4% from a reverse current–voltage scan, a device with a record certified stabilized PCE of 22.6%, and enhanced operational stability. In addition, our perovskite solar cell exhibits an electroluminescence external quantum efficiency up to 8.9%.

14 SOLAR ENERGY↗

An approach to separating Pu, U, and Ti from high-purity graphite for isotopic analysis by MC-ICP-MS

Information about elemental and isotopic systematics of ultra-trace level actinides (e.g. U and Pu) and main group elements (e.g. Ti) present within nuclear grade graphite is vital to the nuclear community for improved reactor operation and security. In support of this, extensive effort has been placed on improving analysis methods (i.e., inductively coupled plasma-mass spectrometry). However, significantly less effort has been devoted to the optimization of chemical separation methods. Within the separation community, commercially available Eichrom™ resins are often employed, as their elution characteristics for various elements have been well studied, but the direct optimization of actinides and trace metal separations from a single sample have not been widely investigated. Here, methods using various Eichrom pre-packed cartridges were explored to achieve separation of ultra-trace levels of U, Pu, and Ti from a variety of graphite samples. Once the validity of the combined separation scheme was established using certified reference materials, the method was applied to historic, unirradiated and irradiated, graphite samples. For all samples investigated, precise isotope ratio measurements for the titanium isotope systems were made.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Rapid 235 U/ 238 U determination by matrix assisted ionization–time-of-flight mass spectrometry

Matrix-assisted ionization (MAI) of inorganic analytes is a nascent research domain that holds promise for rapid, potentially facility-deployable analytical applications. Here, we present results of MAI uranium isotopic analysis ( 235 U/ 238 U) obtained on the timescale of minutes utilizing simple sample preparation and an ambient ionization time-of-flight mass spectrometer (ToF MS). Experimental MAI-ToF MS characterization of uranium Certified Reference Materials (CRMs) was used to establish method calibration and validate quantitative 235 U/ 238 U determination spanning depleted, natural, and low-enriched uranium isotopic compositions. Secondary standard analyses with total uranium mass loadings of 5–500 ng per analysis yield accurate calibrated 235 U/ 238 U results and relative uncertainties of 4.7–17.2% (approx. ±95% confidence level), with weighted-mean uncertainties approaching 1.5%. This method permits accurate determination of uranium isotopic composition in a sample with uranium content as low as 200 pg for equal atom 235 U: 238 U. Instrument detection limits constrain the minimum uranium mass required to identify the presence of highly enriched uranium (HEU ≥20% 235 U) as only 500 pg using the method presented here. MAI-ToF MS quantitation of relatively extreme isotope ratios ( 235 U/ 238 U ≤ 0.01) is limited by detection of minor 235 U (LoD 100 pg 235 U/analysis ≈ 10 ng total U/analysis), and subsequent method optimization is anticipated to further reduce these limits. These findings underscore the potential of MAI-ToF MS for isotopic characterization of uranium and other inorganic species for both basic and applied science.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Plutonium isotope ratio measurements by total evaporation-thermal ionization mass spectrometry (TE-TIMS): an evaluation of uncertainties using traceable standards from the New Brunswick Laboratory

The accuracy and precision of isotope amount ratio measurements using thermal ionization mass spectrometry (TIMS) instrumentation are described, and the measurement of Pu materials is emphasized. The mass fractionation observed for Am, Ga, Pu, and U for isotope amount ratio measurements using the total evaporation (TE) technique is compared with theoretical estimates to demonstrate the advantage of the TE methodology and to investigate systematic biases in the major isotope amount ratios of U and Pu certified reference material (CRM) standards from the U.S. provider of CRMs. The quality of the Pu isotopic data generated by TIMS instruments in an analytical laboratory is demonstrated by the application of the double ratio technique to estimate the 241 Pu half-life. Analytical data on traceable Pu CRMs from the New Brunswick Laboratory (NBL), generated as part of routine measurements supporting various programs, are used for this half-life estimation. Although the 241 Pu abundances in CRMs of 136, 137, 138, and 126-A are approximately 200–2000× smaller than those in the 241 Pu material used in the previous Institute for Reference Materials and Measurements (IRMM) evaluation of the 241 Pu half-life, the half-life value estimated in this work shows excellent agreement with the currently accepted value from the IRMM. This agreement also demonstrates the pedigree of the Pu isotopic standards from the NBL and the quality of the isotope amount ratio measurements using TIMS instrumentation. For both the major and minor Pu isotope amount ratios, this report describes the relative importance of the factors affecting the uncertainty of TIMS measurements, which are considered the gold standard in isotope ratio measurements (LA-UR-24-29199).

07 ISOTOPE AND RADIATION SOURCES↗

Probabilistic error estimation for non-intrusive reduced models learned from data of systems governed by linear parabolic partial differential equations

This work derives a residual-based a posteriori error estimator for reduced models learned with non-intrusive model reduction from data of high-dimensional systems governed by linear parabolic partial differential equations with control inputs. It is shown that quantities that are necessary for the error estimator can be either obtained exactly as the solutions of least-squares problems in a non-intrusive way from data such as initial conditions, control inputs, and high-dimensional solution trajectories or bounded in a probabilistic sense. Here, the computational procedure follows an offline/online decomposition. In the offline (training) phase, the high-dimensional system is judiciously solved in a black-box fashion to generate data and to set up the error estimator. In the online phase, the estimator is used to bound the error of the reduced-model predictions for new initial conditions and new control inputs without recourse to the high-dimensional system. Numerical results demonstrate the workflow of the proposed approach from data to reduced models to certified predictions.

97 MATHEMATICS AND COMPUTING↗

K{sub 0}-NAA for the Determination of Trace Elements in a Synthetic Material: a Collaborative Study

As part of an interlaboratory comparison in order to certify a synthetic material to be used for the validation of the proper implementation of k0-NAA a collaborative trial was organised. Based on this collaborative study RSD{sub r} values (repeatability relative standard deviation) ranging typically from 1 to 2% could be achieved, while RSD{sub R} values (reproducibility relative standard deviation) ranged typically from 2 to 5%. These values were then compared with the Horwitz criterium leading to HORRAT values in most cases well below 1, although two exceeding 1, depending on the element to be determined. It could be concluded that k{sub 0}-NAA is a very precise method, but that still some inconsistencies for certain elements do exist.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Vertical Profiles Of {sup 226}Ra, {sup 232}Th And {sup 40}K Activities In Rocks From The Irati Formation Of The Parana Sedimentary Basin, Southern Brazil

Naturally occurring radioisotopes are present in different concentrations in sedimentary rocks, reflecting the origin of the sediments, the depositional environment, and more recent events such as weathering and erosion. Using a high-resolution {gamma}-ray spectrometry methodology, sedimentary rocks were measured to assess the concentration activities of the natural radioisotopes. The surveyed rocks are from the Irati formation in the Parana sedimentary basin, which are exposed by an abandoned, open-pit limestone mine, in the city of Sapopema, southern Brazil. The exposed vertical profile is 5 m, and its stratigraphy is represented by an alternation of limestone and bituminous shale (layers being a few decimeters thick), and some millimeter rhythm layers with limestone and bituminous shale laminas. Eleven samples were collected along this profile, each of them dried in the open air during 48 hours, sieved through 4 mm mesh and sealed in cylindrical recipients. Measurements were accomplished using a 66% relative efficiency HPGE detector connected to a standard gamma ray spectrometry electronic chain. The detector efficiency in the range of 60 to 1800 keV was carried out with the certified IAEA-385 sediment sample. The Lower Limit of Detection (LLD) to the system is 2.40 Bq{center_dot}kg{sup -1} for {sup 226}Ra, 1.84 Bq{center_dot}kg{sup -1} for {sup 232}Th and 4.20 Bq{center_dot}kg{sup -1} for {sup 40}K. Activity concentrations were determined for {sup 226}Ra (from 16.22 to 151.55 Bq{center_dot}kg{sup -1}), {sup 232}Th (from 2.93 to 56.12 Bq{center_dot}kg{sup -1}) and {sup 40}K (from 38.45 to 644.63 Bq{center_dot}kg{sup -1}). The layers enriched with organic matter presented the higher values of activity. The measured concentrations of the natural radioisotopes were lower for limestone samples (average values and respective deviations were 22.81{+-}0.22 Bq{center_dot}kg{sup -1} for {sup 226}Ra, 4.21{+-}0.07 Bq{center_dot}kg{sup -1} for {sup 232}Th, and 50.11{+-}0.82 Bq{center_dot}kg{sup -1} for {sup 40}K). Higher concentrations were measured for the bituminous shale samples (average values and respective deviations were 108.10{+-}12.17 Bq{center_dot}kg{sup -1} for {sup 226}Ra, 43.69{+-}0.30 Bq{center_dot}kg{sup -1} for {sup 232}Th, and 465.82{+-}3.99 Bq{center_dot}kg{sup -1} for {sup 40}K). The concentrations were intermediate for the rhythmite samples (average values and respective deviations were 50.69{+-}1.09 Bq{center_dot}kg{sup -1} for {sup 226}Ra, 7.63{+-}0.21 Bq{center_dot}kg{sup -1} for {sup 232}Th, and 85.96{+-}2.47 Bq{center_dot}kg{sup -1} for {sup 40}K). As the analyzed rocks are raw materials for the ceramic, cement and soil correction compound industries, the results of this work furnish data to estimate the contribution of these products to the general public's radiation exposure.

54 ENVIRONMENTAL SCIENCES↗

Quantitative Evaluation of Ion-implanted Arsenic in Silicon by Instrumental Neutron Activation Analysis

Certified reference materials (CRMs) of shallow arsenic implants in silicon are now under development at the National Metrology Institute of Japan (NMIJ). The amount of ion-implanted arsenic atoms is quantified by Instrumental Neutron Activation Analysis (INAA) using research reactor JRR-3 in Japan Atomic Energy Agency (JAEA). It is found that this method can evaluate arsenic amounts of 10{sup 15} atoms/cm{sup 2} with small uncertainties, and is adaptable to shallower dopants. The estimated uncertainties can satisfy the industrial demands for reference materials to calibrate the implanted dose of arsenic at shallow junctions.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The United States Particle Accelerator School: Educating the Next Generation of Accelerator Scientists and Engineers

Only a handful of universities in the US offer any formal training in accelerator science. The United States Particle Accelerator School (USPAS) is National Graduate Educational Program that has developed a highly successful educational paradigm that, over the past twenty-years, has granted more university credit in accelerator/beam science and technology than any university in the world. Sessions are held twice annually, hosted by major US research universities that approve course credit, certify the USPAS faculty, and grant course credit. The USPAS paradigm is readily extensible to other rapidly developing, cross-disciplinary research areas such as high energy density physics.

43 PARTICLE ACCELERATORS↗

Evaluation of the InSTEC's EDXRF assembly for Marine Sediment Pollution Studies

The determination of some heavy elements in marine sediments using the InSTEC's EDXRF assembly was evaluated. The spectrometer's main analytical characteristics were performed using {sup 109}Cd and {sup 238}Pu excitation sources. The system capabilities are tested by the analysis of the Certified Reference Material (CRM) IAEA-356. The results show that the K, Ca, Ti, Mn, Fe, Cu, Zn, Br, Rb, Zr and Pb elemental concentrations can be determined in marine sediments with an excellent accuracy and Co, Ni, Sr and Mo concentrations with an acceptable accuracy.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A Sight on the Variation of Spectral Parameters in GRBs

Gamma ray bursts (GRBs) are high energy photons detected during a short interval of time. They are signs of the most energetic events in the universe. Photons detected show a non thermal spectrum, very well described by the peak energy and two smoothly connected power laws with different slopes or indices. This spectrum is named Band spectrum and serves actually as the most important source of information on their physical origin. It characterizes not only the overall emission, but also the instantaneous one, found in small successive intervals of time during the event. The time-resolved spectra show an obvious evolution in energy, which is generally accepted and supported by several arguments. There is also some evidence in measuring a kind of evolution in slope parameters, which would be considered as a serious source of information for the physical mechanism. In this work we try to examine the limit in observation bands, which we suspect as a reason for the apparent variation in time of spectral indices. Our work is based on a numeric and certified code. We simulate GRBs assuming synchrotron emission in the internal shocks model. For each time-resolved spectrum we find spectral parameters based on the Band function.

79 ASTRONOMY AND ASTROPHYSICS↗

The Preparation and Characterization of Nd{sub 2}O{sub 3} Doped Borate Glass

The Nd{sup 3+} doped borate glass of Nd{sub 2}O{sub 3}-MgO-ZnO-B{sub 2}O{sub 3} glass system is successfully been prepared by melt-quenched technique. Batches of 15g were prepared from certified reagent grades of B{sub 2}O{sub 3}(99.95% purity), MgO (97%), ZnO (98% purity), and Nd{sub 2}O{sub 3}(99.99%). The measured glass densities are found varies from 5683.2 kgm{sup -3} to 5724.0 kgm{sup -3}. The increment in density implies that an addition of Nd{sub 2}O{sub 3} with higher atomic masses than B{sub 2}O{sub 3} tend to increase the packing density of the glass structures since the atomic masses of B{sub 2}O{sub 3} and Nd{sub 2}O{sub 3} are 69.62 and 336.42 respectively. From the density values obtained, the molar volume of glasses was calculated. From the results, it is found that the molar volume of these glasses decreases slightly from 22.50 cm{sup 3} to 27.54 cm{sup 3} with respect to Nd{sub 2}O{sub 3} content.

36 MATERIALS SCIENCE↗

Epithermal Neutron Activation Analysis of the Asian Herbal Plants

Asian medicinal herbs Chrysanthemum (Spiraea aquilegifolia Pall.) and Red Sandalwood (Pterocarpus Santalinus) are widely used in folk and Ayurvedic medicine for healing and preventing some diseases. The modern medical science has proved that the Chrysanthemum (Spiraea aquilegifolia Pall.) possesses the following functions: reducing blood press, dispelling cancer cell, coronary artery's expanding and bacteriostating and Red Sandalwood (Pterocarpus Santalinus) is recommended against headache, toothache, skin diseases, vomiting and sometimes it is taken for treatment of diabetes. Species of Chrysanthemums were collected in the north-eastern and central Mongolia, and the Red Sandalwood powder was imported from India. Samples of Chrysanthemums (branches, flowers and leaves)(0.5 g) and red sandalwood powder (0.5 g) were subjected to the multi-element instrumental neutron activation analysis using epithermal neutrons (ENAA) at the IBR-2 reactor, Frank Laboratory of Neutron Physics (FLNP) JINR, Dubna. A total of 41 elements (Na, Mg, Al, Cl, K, Ca, Sc, V, Cr, Mn, Fe, Co, Ni, Zn, As, Se, Br, Rb, Sr, Zr, Mo, Cd, Cs, Ba, La, Hf, Ta, W, Sb, Au, Hg, Ce, Nd, Sm, Eu, Tb, Dy, Yb, Th, U, Lu) were determined. For the first time such a large group of elements was determined in the herbal plants used in Mongolia. The quality control of the analytical results was provided by using certified reference material Bowen Cabbage. The results obtained are compared to the ''Reference plant? data (B. Markert, 1992) and interpreted in terms of excess of such elements as Se, Cr, Ca, Fe, Ni, Mo, and rare earth elements.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Using Photon Activation Analysis To Determine Concentrations Of Unknown Components In Reference Materials

Using certified multi-element reference materials for instrumental analyses one frequently is confronted with the embarrassing fact that the concentration of some desired elements are not given in the respective certificate, nonetheless are detectable, e.g. by photon activation analysis (PAA). However, these elements might be determinable with sufficient quality of the results using scaling parameters and the well-known quantities of a reference element within the reference material itself. Scaling parameters include: activation threshold energy, Giant Dipole Resonance (GDR) peak and endpoint energy of the bremsstrahlung continuum; integrated photo-nuclear cross sections for the isotopes of the reference element; bremsstrahlung continuum integral; target thickness; photon flux density. Photo-nuclear cross sections from the unreferenced elements must be known, too. With these quantities, the integral was obtained for both the known and unknown elements resulting in an inference of the concentration of the unreported element based upon the reported value, thus also the concentration of the unreferenced element in the reference material. A similar method to determine elements using the basic nuclear and experimental data has been developed for thermal neutron activation analysis some time ago (k{sub 0} Method).

07 ISOTOPE AND RADIATION SOURCES↗

Development and setting of a new system for advanced rheocast components

This paper presents an overview of alternative methods of production of enhanced performance Al-based alloys components for critical areas. In particular, a new rheocasting system, suitable for the manufacturing of high performance industrial components has been considered. The aforementioned method allows obtaining component quickly and results a more convenient process, from economical point of view than other innovative processes. Two series of components have been produced with A356 and A357 alloys, then have been heat treated using T5 and T6 treatments. On polished transverse sections of samples the microstructure of the alloy has been observed. Their soundness has been previously certified by non destructive tests. Samples for tensile and three point bending tests have been machined directly from the produced components. On the fractured samples, fracture surface analysis has been performed in order to analyze and evaluate the influence of the process and of the alloy on the fracture behaviour.

36 MATERIALS SCIENCE↗