Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Calorimeters”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 541 records · Page 30

Development of an Infrared Lamp Array for the Smap Spacecraft Thermal Balance Test

NASA launched the SMAP observatory in January 2015 aboard a Delta II into a sun-synchronous orbit around Earth. The science payload of a radar and a radiometer utilizes a shared rotating six-meter antenna to provide a global map of the Earth's soil moisture content and its freeze/thaw state on a global, high-resolution scale in this three-year mission. An observatory-level thermal balance test conducted in May/June 2014 validated the thermal design and demonstrated launch readiness as part of the planned environmental test campaign. An infrared lamp array was designed and used in the thermal balance test to replicate solar heating on the solar array and sunlit side of the spacecraft that would normally be seen in orbit. The design, implementation, and operation of an infrared lamp array used for this nineteen-day system thermal test are described in this paper. Instrumental to the smooth operation of this lamp array was a characterization test performed in the same chamber two months prior to the observatory test to provide insight into its array operation and flux uniformity. This knowledge was used to identify the lamp array power settings that would provide the worst case predicted on-orbit fluxes during eclipse, cold, and hot cases. It also showed the lamp array variation when adjustments in flux were needed. Calorimeters calibrated prior to testing determined a relationship between calorimeter temperature and lamp array flux. This allowed the team to adjust the lamp output for the desired absorbed flux on the solar array. Flux levels were within 10% of the desired value at the center of the solar array with an ability to maintain these levels within 5% during steady state cases. All tests demonstrated the infrared lamp array functionality and furthered lamp array understanding for modeling purposes. This method contributed to a high-fidelity environmental simulation, which was required to replicate the extreme on-orbit thermal environments.

Miller, Jennifer R.↗

Development of a Silicon Tracker for the All-Sky Medium Energy Gamma-ray Observatory Prototype

The gamma-ray sky from several hundred keV to a hundred MeV has remained largely unexplored due to the challenging nature of detecting gamma rays in this regime. At lower energies, Compton scattering is the dominant interaction process whereas at higher energies pair production dominates, with a crossover at a few MeV. Thus, an instrument designed to work in this energy range must be optimized for both Compton and pair-production events. AMEGO, the All-sky Medium Energy Gamma-ray Observatory, a Probe-class mission in consideration for the 2020 decadal survey, is designed to operate at energies from 200 keV to > 10 GeV with over an order of magnitude increase in sensitivity and with superior angular and energy resolution compared to previous instruments. AMEGO comprises four major subsystems: a plastic anticoincidence detector for rejecting cosmic-ray events, a silicon tracker for tracking pair-production products and tracking and measuring the energies of Compton-scattered electrons, a cadmium-zinc-telluride (CZT) calorimeter for measuring the energy and location of Compton scattered photons, and a CsI calorimeter for measuring the energy of the pair-production products at high energies. A prototype instrument, known as ComPair, is under development at NASA’s Goddard Space Flight Center and the US Naval Research Laboratory. In this contribution, we provide details on the development of the silicon tracker subsystem.

Griffin, Sean↗

CFD Simulations of the IHF 13-Inch Nozzle Flow: 55-deg Sphere-Cone Model, Manufactured Fences and Gaps

This paper reports computational analyses of testsin a high enthalpy arc-jet facility at NASA Ames Research Center. These tests were conducted using 55-deg sphere-cone models placed in a free jet downstream of the 13-inch diameter conical nozzle in the Ames 60-MW Interaction Heating Facility. Some of the sphere-cone models include surface features such as manufactured fences and gaps intended to simulate effects of differential recession, all of which disturb the flow, producing augmented heating locally and downstream.Test calibration data were obtained using slug and Gardon gage stagnation calorimeters, and a sphere-cone calorimeter model with six Gardon gages and five pressure tabs.The present analysis comprises computational fluid dynamics simulations of the nonequilibrium flowfield in the facility nozzle and test box, including the models tested, and comparisons with the experimental measurements. These simulations take into account nonuniform total enthalpy and mass flux profiles at the nozzle inlet as well as the expansion waves emanating from the nozzle exit and their effects on the model flowfields.

Arc-jets↗

Comparative Analysis of Thermal Runaway Heat Output as a Function of Trigger Mechanism and Cell Format

High demand for energy storage systems across many fields drives the need for safe and reliable Li-ion batteries. In order to assess the risk of using such batteries in various applications, many types of abuse tests have been developed to push battery cells to their limits and learn how they fail. In this work, internal short circuit (ISC) tests, nail penetration tests, and thermal tests were used to trigger thermal runaway in D-cell, 18650, and 21700 Li-ion cells. High-speed radiography was used to gain insight to the propagation of thermal runaway throughout the cell, while calorimetric and thermal data were recorded in real time. Post-test disassembly of the calorimeter allowed for any mass ejected from the cell to be analyzed and the distribution of mass through the calorimeter to be determined. The impact of cell geometry and trigger mechanism on post-test mass distribution, thermal runaway propagation and internal cell temperature are discussed.

Lithium-ion battery; thermal runaway; calorimetry;↗

AMEGO: Exploring the Extreme Multimessenger Universe

The All-sky Medium Energy Gamma-ray Observatory (AMEGO) is a Probe-class mission concept that will provide essential contributions to multimessenger astrophysics in the next decade. AMEGO operates both as a Compton and pair telescope to achieve unprecedented sensitivity between 200 keV and>5 GeV. The instrument consists of four subsystems. A double-sided strip silicon Tracker gives a precise measure of the first Compton scatter interaction and tracks of pair-conversion products. A novel CdZnTe Low Energy Calorimeter with excellent position and energy resolution surrounds the bottom and sides of the Tracker to detect the Compton-scattered photons which enhances the polarization and narrow-line sensitivity. A thick CsI High Energy Calorimeter contains the high-energy Compton and pair events. The instrument is surrounded by aplastic anti-coincidence detector to veto the cosmic-ray background. We have performed detailed simulations to predict the telescope performance and are currently building a prototype instrument. The AMEGO prototype, known as ComPair, will be tested at the High Intensity Gamma-Ray Source in 2021, followed by a balloon flight in Fall of 2022. In this presentation we will give an overview of the science motivation, a description of the observatory, and an update of the prototype instrument development.

Carolyn Ann Kierans↗

CALET Results After Three Years on Orbit on the International Space Station

The CALorimetric Electron Telescope (CALET) is an astroparticle physics experiment installed on the International Space Station since August 2015. The CALET mission was conceived to address several outstanding questions of high-energy astroparticle physics, like indirect detection of dark matter, the origin of cosmic rays (CRs), their mechanisms of acceleration and galactic propagation, the presence of possible nearby astrophysical CR sources. That can be achieved by precise measurements of the fluxes of CR electrons and gamma-rays up to the unexplored region above 1 TeV, and the energy spectra and composition of CR nuclei from a few tens of GeV to hundreds of TeV. In order to perform these observations, the instrument combines a thick total absorption PWO crystal calorimeter for energy measurement, a scintillator hodoscope for charge identi cation and thin imaging tungsten-scintillating fiber calorimeter providing accurate particle tracking and complementary charge measurement. In this paper, we will present an overview of the main CALET results based on the data collected in the first three years of the mission.

P Maestro↗

CFD Simulations of the IHF 13-Inch Nozzle Flow: 55-deg Sphere-Cone Model, Manufactured Fences and Gaps

This paper reports computational analyses of tests in a high enthalpy arc-jet facility at NASA Ames Research Center. These tests were conducted using 55-deg sphere-cone models placed in a free jet downstream of the 13-inch diameter conical nozzle in the Ames 60-MW Interaction Heating Facility. Some of the sphere-cone models include surface features such as manufactured fences and gaps intended to simulate effects of differential recession, all of which disturb the flow, producing augmented heating locally and downstream. Test calibration data were obtained using slug and Gardon gage stagnation calorimeters, and a sphere-cone calorimeter model with six Gardon gages and five pressure tabs. The present analysis comprises computational fluid dynamics simulations of the nonequilibrium flowfield in the facility nozzle and test box, including the models tested, and comparisons with the experimental measurements. These simulations take into account nonuniform total enthalpy and mass flux profiles at the nozzle inlet as well as the expansion waves emanating from the nozzle exit and their effects on the model flowfields.

Arc-jets↗

CFD Simulations of the IHF 13-Inch Nozzle Flow: 55-deg Sphere-Cone Model, Manufactured Fences and Gaps

This paper reports computational analyses of tests in a high enthalpy arc-jet facility at NASA Ames Research Center. These tests were conducted using 55-deg sphere-cone models placed in a free jet downstream of the 13-inch diameter conical nozzle in the Ames 60-MW Interaction Heating Facility. Some of the sphere-cone models include surface features such as manufactured fences and gaps intended to simulate effects of differential recession, all of which disturb the flow, producing augmented heating locally and downstream. Test calibration data were obtained using slug and Gardon gage stagnation calorimeters, and a sphere-cone calorimeter model with six Gardon gages and five pressure tabs. The present analysis comprises computational fluid dynamics simulations of the nonequilibrium flowfield in the facility nozzle and test box, including the models tested, and comparisons with the experimental measurements. These simulations take into account nonuniform total enthalpy and mass flux profiles at the nozzle inlet as well as the expansion waves emanating from the nozzle exit and their effects on the model flowfields.

Arc-jets↗

Direct Measurement of the Spectral Structure of Cosmic-Ray Electrons+Positrons in the Tev Region With Calet on the International Space Station

Detailed measurements of the spectral structure of cosmic-ray electrons and positrons from 10.6 GeV to 7.5 TeV are presented from over 7 years of observations with the CALorimetric Electron Telescope (CALET) on the International Space Station. The instrument, consisting of a charge detector, an imaging calorimeter, and a total absorption calorimeter with a total depth of 30 radiation lengths at normal incidence and a fine shower imaging capability, is optimized to measure the all-electron spectrum well into the TeV region. Because of the excellent energy resolution (a few percent above 10 GeV) and the outstanding e/p separation (10 5 ), CALET provides optimal performance for a detailed search of structures in the energy spectrum. The analysis uses data up to the end of 2022, and the statistics of observed electron candidates has increased more than 3 times since the last publication in 2018. By adopting an updated boosted decision tree analysis, a sufficient proton rejection power up to 7.5 TeV is achieved, with a residual proton contamination less than 10%. The observed energy spectrum becomes gradually harder in the lower energy region from around 30 GeV, consistently with AMS-02, but from 300 to 600 GeV it is considerably softer than the spectra measured by DAMPE and Fermi-LAT. At high energies, the spectrum presents a sharp break around 1 TeV, with a spectral index change from −3.15 to −3.91, and a broken power law fitting the data in the energy range from 30 GeV to 4.8 TeV better than a single power law with 6.9 sigma significance, which is compatible with the DAMPE results. The break is consistent with the expected effects of radiation loss during the propagation from distant sources (except the highest energy bin). We have fitted the spectrum with a model consistent with the positron flux measured by AMS-02 below 1 TeV and interpreted the electron+positron spectrum with possible contributions from pulsars and nearby sources. Above 4.8 TeV, a possible contribution from known nearby supernova remnants, including Vela, is addressed by an event-by-event analysis providing a higher proton-rejection power than a purely statistical analysis.

O. Adriani↗

Design and Performance of the Hitomi/XRISM Adiabatic Demagnetization Refrigerator Controller

The Resolve instrument in the recently launched X-ray Imaging and Spectroscopy Mission (XRISM) is a rebuild of the Soft X-ray Spectrometer (SXS) in Hitomi (aka Astro-H which had an unfortunately brief mission life in 2016). It is a high-resolution non-dispersive soft x-ray spectrometer from nominally 0.3 keV to 12 keV based on a calorimeter detector array operating at 50 mK with a resolution better than 7 eV FWHM at 6 keV. For such sensitive cryogenic instruments, temperature stability has a strong impact on the detector’s performance. The Adiabatic Demagnetization Refrigerator Controller (ADRC) in the XRISM Resolve instrument is an electronics box responsible for high-precision sub-K temperature readout and control of the multi-stage adiabatic demagnetization refrigerator subsystem to achieve a thermal stability better than 2.5 uK RMS (over a 10-minute interval) for the calorimeter detectors in both cryogen (liquid helium) and cryo-free modes. It has direct telemetry/command and power interfaces with the spacecraft. It also provides sensor read-out and heater circuits for decontamination of the filters in the cold aperture. As a part of the discussion on the design and performance of the ADRC, this paper will also include an overall view of the 50 mK temperature control, plus monitor and control of the aperture filter temperature for de-contamination purpose.

ADRC↗

Design and Performance of the Hitomi/XRISM Adiabatic Demagnetization Refrigerator Controller

The Resolve instrument in the recently launched X-ray Imaging and Spectroscopy Mission (XRISM) is a rebuild of the Soft X-ray Spectrometer (SXS) in Hitomi (aka Astro-H which had an unfortunately brief mission life in 2016). It is a high-resolution non-dispersive soft x-ray spectrometer from nominally 0.3 keV to 12 keV based on a calorimeter detector array operating at 50 mK with a resolution better than 7 eV FWHM at 6 keV. For such sensitive cryogenic instruments, temperature stability has a strong impact on the detector’s performance. The Adiabatic Demagnetization Refrigerator Controller (ADRC) in the XRISM Resolve instrument is an electronics box responsible for high-precision sub-K temperature readout and control of the multi-stage adiabatic demagnetization refrigerator subsystem to achieve a thermal stability better than 2.5 uK RMS (over a 10-minute interval) for the calorimeter detectors in both cryogen (liquid helium) and cryo-free modes. It has direct telemetry/command and power interfaces with the spacecraft. It also provides sensor read-out and heater circuits for decontamination of the filters in the cold aperture. As a part of the discussion on the design and performance of the ADRC, this paper will also include an overall view of the 50 mK temperature control, plus monitor and control of the aperture filter temperature for de-contamination purpose.

ADRC↗

Dual-Readout Calorimetry for Future Experiments Probing Fundamental Physics

In this White Paper for the 2021 Snowmass process, we detail the status and prospects for dual-readout calorimetry. While all calorimeters allow estimation of energy depositions in their active material, dual-readout calorimeters aim to provide additional information on the light produced in the sensitive media via, for example, wavelength and polarization, and/or a precision timing measurements, allowing an estimation of the shower-by-shower particle content. Utilizing this knowledge of the shower particle content may allow unprecedented energy resolution for hadronic particles and jets and new types of particle flow algorithms. We also discuss the impact continued development of this kind of calorimetry could have on precision on Higgs boson property measurements at future colliders.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Readout for Calorimetry at Future Colliders: A Snowmass 2021 White Paper

Calorimeters will provide critical measurements at future collider detectors. As the traditional challenge of high dynamic range, high precision, and high readout rates for signal amplitudes is compounded by increasing granularity and precision timing the readout systems will become increasingly complex. This white paper reviews the challenges and opportunities in calorimeter readout at future collider detectors.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

PIONEER: Studies of Rare Pion Decays

A next-generation rare pion decay experiment, PIONEER, is strongly motivated by several inconsistencies between Standard Model (SM) predictions and data pointing towards the potential violation of lepton flavor universality. It will probe non-SM explanations of these anomalies through sensitivity to quantum effects of new particles even if their masses are at very high scales. Measurement of the charged-pion branching ratio to electrons vs. muons $R_{e/\mu}$ is extremely sensitive to new physics effects. At present, the SM prediction for $R_{e/\mu}$ is known to 1 part in $10^4$, which is 15 times more precise than the current experimental result. An experiment reaching the theoretical accuracy will test lepton flavor universality at an unprecedented level, probing mass scales up to the PeV range. Measurement of pion beta decay, $\pi^+\to \pi^0 e^+ \nu (\gamma)$, with 3 to 10-fold improvement in sensitivity, will determine $V_{ud}$ in a theoretically pristine manner and test CKM unitarity, which is very important in light of the recently emerged tensions. In addition, various exotic rare decays involving sterile neutrinos and axions will be searched for with unprecedented sensitivity. The experiment design benefits from experience with the recent PIENU and PEN experiments at TRIUMF and the Paul Scherrer Institut (PSI). Excellent energy and time resolutions, greatly increased calorimeter depth, high-speed detector and electronics response, large solid angle coverage, and complete event reconstruction are all critical aspects of the approach. The PIONEER experiment design includes a 3$\pi$ sr 25 radiation length calorimeter, a segmented low gain avalanche detector stopping target, a positron tracker, and other detectors. Using intense pion beams, and state-of-the-art instrumentation and computational resources, the experiments can be performed at the PSI ring cyclotron.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Nucleon Structure Studies at Jefferson Lab and the Electron Ion Collider

The research programs of Thomas Jefferson Laboratory (JLab) and the future Electron- Ion Collider (EIC) focus on one of the main goals of strong interaction studies : understanding the structure of nucleons in terms of the quarks and gluons composing them. Their structure is encoded in functions such as Generalized Parton Distributions (GPDs), which describe how quarks and gluons’ transverse position and longitudinal momentum are distributed inside nucleons. GPDs allow to obtain three-dimensional pictures of nucleons and to understand some of their fundamental properties, such as their internal pressure or the emergence of their spin from the dynamics of the partons composing them. At JLab and the EIC, electron beams are used to probe nucleons. Measurement of reactions such as Deeply Virtual Compton Scattering (DVCS) allows access to GPDs. The first longitudinally polarized-target experiment of the CLAS12 program at Jlab took place in 2022-2023. Combining polarized electron beams and nucleon targets, this experiment offers unique access to observables that allow the measurement of different types of GPDs. In particular, the DVCS beam- and target-spin asymmetries for protons and neutrons in deuterium will be measured for the first time. They give access to kinds of GPDs that are still poorly known, and the comparison between proton and neutron data will allow the extraction of the flavor dependence of the structure of nucleons. Specific analysis methods have been implemented to work with a polarized nuclear target and are presented in this thesis. These methods allow to obtain preliminary results for the asymmetries, waiting for the complete statistics to be available. In the long term, the experimental program for the EIC has been established with a strong emphasis on the measurement of the structure of nucleons at high energy. Measurements of reactions such as DVCS impose strict requirements on the electromagnetic calorimeter that will allow to measure the energy of the scattered electrons and photons. This calorimeter, which is under development, will be based on scintillating crystals read by Silicon Photomultipliers (SiPMs). A new type of glass-based scintillating material was tested, evaluating the possibilities to meet the technical requirements concerning their light yield and resistance to radiation damage in particular. Several models of SiPMs have been characterized, demonstrating they can operate over the vast energy range necessary to address the physics case at the EIC and providing guidelines for developing their readout electronics.

Pilleux, Noemie↗

Diagnostic Systems in the Muon $g-2$ experiment at Fermilab

The muon anomalous magnetic moment, $a_\mu=\frac{g-2}{2}$, is a low-energy observable which can be both measured and computed to high precision, making it a sensitive test of the Standard Model and a probe for new physics. This anomaly was measured with a precision of $0.20$~parts per million (ppm) by the Fermilab's Muon g-2 (E989) experiment. The final goal of the E989 experiment is to reach a precision of $0.14$~ppm. The experiment is based on the measurement of the muon spin anomalous precession frequency, $\omega_a$, based on the arrival time distribution of high-energy decay positrons observed by 24 electromagnetic calorimeters, placed around the inner circumference of a $14$~m diameter storage ring, and on the precise knowledge of the storage ring magnetic field and of the beam time and space distribution. Achieving this level of precision requires strict control over systematics, which is ensured through several diagnostic devices. At the accelerator level, these devices monitor the quality of the injected beam (e.g., verifying that it has the correct momentum), while at the detector level, they track both the magnetic field and the gain of the calorimeters. In this work the devices and techniques used by the E989 experiment will be presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Modeling a Sodium Heat Pipe Experiment at SPHERE Using Sockeye

The Single Primary Heat Extraction and Rejection Emulator (SPHERE) facility at Idaho Na- tional Laboratory was recently utilized to generate data for the startup and steady operation of a high-performance, sodium heat pipe over the course of 1000 hours, as a test of detrimental, long-term effects of heat pipe operation. The setup consists of a single, sodium heat pipe enclosed in a stainless-steel vacuum chamber, heated radiatively via a cylindrical ceramic fiber heater configuration and cooled via a water-cooled calorimeter. Measurements include temperatures at several axial locations along the outer surface of the heat pipe, the power provided to the heaters, and the heat removal rate of the calorimeter. In this work, this data is utilized to validate heat pipe models in the heat pipe application Sockeye, which is based upon the Multiphysics Object-Oriented Simulation Environment (MOOSE) framework. Sockeye provides various heat pipe models at an engineering scale appropriate for the multiphysics simulation of microreactors, which may feature several hundred heat pipes. This work details models of this experiment in SPHERE using various heat pipe models with Sockeye, including heat conduction-based models and compressible flow models of the heat pipe interior. These models are compared to the experimental data to assess the accuracy of several aspects of heat pipe modeling, including frozen startup, the effect of non-condensable gases, and the coupling of the heat pipe to its environment.

97 - MATHEMATICS AND COMPUTING↗

Modeling a Sodium Heat Pipe Experiment at SPHERE Using Sockeye

The Single Primary Heat Extraction and Rejection Emulator (SPHERE) facility at Idaho National Laboratory was recently utilized to generate data for the startup and steady operation of a high-performance, sodium heat pipe over the course of 1,000 hours to test the detrimental, long-term effects of heat pipe operation. The setup consisted of a single, sodium heat pipe enclosed in a stainless-steel vacuum chamber, heated radiatively via a cylindrical ceramic-fiber heater configuration and cooled via a water-cooled calorimeter. Measurements included temperatures at several axial locations along the outer surface of the heat pipe, the power provided to the heaters, and the heat removal rate of the calorimeter. In this work, we use this data to validate heat pipe models in Sockeye, a heat pipe application based on the Multiphysics Object-Oriented Simulation Environment (MOOSE) framework. Sockeye provides various heat pipe models at an engineering scale appropriate for the multiphysics simulation of microreactors, which may feature several hundred heat pipes. This work details models of this experiment at SPHERE using various heat pipe models with Sockeye, including heat-conduction-based and compressible flow models of the heat pipe interior.

97 - MATHEMATICS AND COMPUTING↗