Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “COUNTING RATES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 541 records · Page 30

Neutron multiplicity analysis tool

I describe the capabilities of the EXCOM (EXcel based COincidence and Multiplicity) calculation tool which is used to analyze experimental data or simulated neutron multiplicity data. The input to the program is the count-rate data (including the multiplicity distribution) for a measurement, the isotopic composition of the sample and relevant dates. The program carries out deadtime correction and background subtraction and then performs a number of analyses. These are: passive calibration curve, known alpha and multiplicity analysis. The latter is done with both the point model and with the weighted point model. In the current application EXCOM carries out the rapid analysis of Monte Carlo calculated quantities and allows the user to determine the magnitude of sample perturbations that lead to systematic errors. Neutron multiplicity counting is an assay method used in the analysis of plutonium for safeguards applications. It is widely used in nuclear material accountancy by international (IAEA) and national inspectors. The method uses the measurement of the correlations in a pulse train to extract information on the spontaneous fission rate in the presence of neutrons from ({alpha},n) reactions and induced fission. The measurement is relatively simple to perform and gives results very quickly ({le} 1 hour). By contrast, destructive analysis techniques are extremely costly and time consuming (several days). By improving the achievable accuracy of neutron multiplicity counting, a nondestructive analysis technique, it could be possible to reduce the use of destructive analysis measurements required in safeguards applications. The accuracy of a neutron multiplicity measurement can be affected by a number of variables such as density, isotopic composition, chemical composition and moisture in the material. In order to determine the magnitude of these effects on the measured plutonium mass a calculational tool, EXCOM, has been produced using VBA within Excel. This program was developed to help speed the analysis of Monte Carlo neutron transport simulation (MCNP) data, and only requires the count-rate data to calculate the mass of material using INCC's analysis methods instead of the full neutron multiplicity distribution required to run analysis in INCC. This paper describes what is implemented within EXCOM, including the methods used, how the program corrects for deadtime, and how uncertainty is calculated. This paper also describes how to use EXCOM within Excel.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Monitoring the Bragg peak location of 73 MeV/u carbon ions by means of prompt {gamma}-ray measurements

By means of a time-of-flight technique, we measured the longitudinal profile of prompt {gamma}-rays emitted by 73 MeV/u {sup 13}C ions irradiating a polymethyl methacrylate target. This technique allowed us to minimize the shielding against neutrons and scattered {gamma}-rays, and to correlate prompt gamma emission to the ion path. This correlation, together with a high counting rate, paves the way toward real-time monitoring of the longitudinal dose profile during ion therapy treatments. Moreover, the time correlation between the prompt gamma detection and the transverse position of the incident ions measured by a beam monitor can provide real-time three dimensional control of the irradiation.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A collimated neutron detector for RFP plasmas in MST

The neutron emissivity profile in the Madison Symmetric Torus is being reconstructed through the use of a collimated neutron detector. A scintillator-photomultiplier tube (PMT) system is employed to detect the fusion neutrons with the plasma viewing volume defined by a 55 cm deep, 5 cm diameter aperture. Effective detection of neutrons from the viewing volume is achieved through neutron moderation using 1300 lbs of high density polyethylene shielding, which modeling predicts attenuates the penetrating flux by a factor of 10{sup 4} or more. A broad spectrum of gamma radiation is also present due to the unconfined fusion proton bombardment of the thick aluminum vacuum vessel. A 15 cm cylindrical liquid scintillator of 3.8 cm diameter is used to further increase directional sensitivity. A fast (5 ns rise time) preamplifier and digitization at 500 MHz prevent pulse pile-up even at high count rates (∼10{sup 4}/s). The entire neutron camera system is situated on an adjustable inclining base which provides the differing plasma viewing volumes necessary for reconstruction of the neutron emissivity profile. This profile, directly related to the fast-ion population, allows for an investigation of the critical fast-ion pressure gradient required to destabilize a neutral beam driven Alfvénic mode which has been shown to transport fast ions.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Rapid three-dimensional imaging of defect distributions using a high-intensity positron microbeam

An intense positron microbeam generated by an electron accelerator has been developed for obtaining three-dimensional positron lifetime mappings in a sample to permit visual evaluation of defect distributions. The beam diameter at the sample was 80-100 {mu}m. The counting rate of the positron annihilation {gamma} rays used to measure positron lifetime was as large as 3x10{sup 3} s{sup -1}. Three-dimensional imaging was demonstrated of positron lifetimes in a SiO{sub 2} sample, which was irradiated with ion beams through a mesh mask. The time to obtain a single image (3500 pixels for an area of 2.5x3.5 mm{sup 2}) was 0.5-1 h.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Photon Science at Modern Light Sources

More than 50 large x-ray and UV light sources based on high-energy electron accelerators are in operation around the world, serving a scientific community numbering in the tens of thousands. These sources generate synchrotron radiation from accelerated electrons or positrons. The development of synchrotron light sources over the last 40 years has fueled an exponential increase in x-ray source brightness of more than 10 orders of magnitude. The next large advance in source potential is now underway, with the commissioning of the first x-ray Free-Electron Laser (FEL) sources. Using high-energy electron linear accelerators, these facilities produce sub-picosecond pulses of hard x-rays with peak brightness more than 10 orders of magnitude greater than current synchrotron facilities. FEL x-ray facilities will soon be operational in the US, Japan, and Germany.Research at modern light sources makes use of a wide range of experimental techniques. Many experiments are designed to study the structure of matter at the atomic scale using elastic x-ray scattering. This technique has been particularly effective for determining the structures of biological molecules, such as proteins, viruses, and drugs. Inelastic x-ray scattering, or x-ray absorption followed by emission of electrons or photons, can give information about the electronic structures of atoms, which can be used to deduce local environment information such as atomic species, bonding state, geometry of neighboring atoms, or magnetic state. For some techniques involving x-ray emission from a sample, cryogenic detectors with energy resolution at the {approx}10 eV level or better would be very helpful. Shifts in electron energy levels associated with bonding states and magnetic states are typically several eV, while the energy structure associated with Compton inelastic scattering is typically in the range of a few tens of eV. Current energy-resolving detectors used at synchrotron light sources are hampered by either poor energy resolution ({approx}100 eV for solid state detectors), or very poor angular acceptance (10{sup -3} sr or worse for grating and crystal analyzer detectors).Photon detectors at synchrotron light sources can be presented with very high signal count rates. At the new FEL sources, this issue will be especially acute, since each sub-picosecond pulse will deliver the flux produced in one second by a synchrotron. This invites the use of multiple small detectors to spread the load. The ideal energy-resolving detector for x-ray science at modern light sources would combine eV-level energy resolution, 100-{mu}m pixel size, and a low per-pixel cost allowing several megapixels to be deployed.

74 ATOMIC AND MOLECULAR PHYSICS↗

The NUSTAR view of a QPO evolution of GRS 1915+105

We report a timing analysis of the black hole binary GRS 1915+105 with the Nuclear Spectroscopic Telescope Array Observatory. A strong type-C quasi-periodic oscillation (QPO) below 2 Hz appears in the power density spectrum during the whole observation, whose frequency is correlated with the 3–25 keV count rate. The QPO shows a sudden increase in frequency along with an increase in flux and a softening of the spectrum. We discuss the possible origin of the QPO and the reasons that lead to the QPO frequency variation. It is suggested that the reflection component has little influence on QPO frequency and the increase in QPO frequency could be associated with the inward motion of the outer part of the disk.

79 ASTRONOMY AND ASTROPHYSICS↗

Tracking the evolution of quasi-periodic oscillation in RE J1034+396 using the Hilbert-Huang transform

RE J1034+396, a narrow-line Seyfert 1 active galactic nucleus (AGN), is the first example of AGNs that exhibited a nearly coherent quasi-periodic oscillation (QPO) for the data collected by XMM-Newton in 2007. The spectral behaviors and timing properties of the QPO have been studied since its discovery. We present an analysis of the QPO in RE J1034+396 based on the Hilbert-Huang transform. Comparing with other time-frequency analysis methods, the Hilbert spectrum reveals the variation of the QPO period in great detail. Furthermore, the empirical mode decomposition provides bandpass-filtered data that can be used in the O – C and correlation analysis. We suggest that it is better to divide the evolution of the QPO in this observation into three epochs according to their different periodicities. In addition to the periodicities, the correlations between the QPO periods and corresponding mean count rates are also different in these three epochs. Further examining the phase lags in these epochs, we found no significant phase lags between the soft and hard X-ray bands, which is also confirmed in the QPO phase-resolved spectral analysis. Finally, we discuss the indications of current models including a spotted accretion disk, diskoseismology, and oscillation of shock according to the observed time-frequency and spectral behaviors.

79 ASTRONOMY AND ASTROPHYSICS↗

Experimental approaches for the development of gamma spectroscopy well logging system

This article discusses experimental approaches for the development of gamma spectroscopy well logging system. Considering the size of borehole sonde, we customize 2 x 2 inches inorganic scintillators and the system including high voltage, preamplifier, amplifier and multichannel analyzer (MCA). The calibration chart is made by test using standard radioactive sources so that the measured count rates are expressed by energy spectrum. Optimum high-voltage supplies and the measurement parameters of each detector are set up by experimental investigation. Also, the responses of scintillation detectors have been examined by analysis according to the distance between source and detector. Because gamma spectroscopy well logging needs broad spectrum, high sensitivity and resolution, the energy resolution and sensitivity as a function of gamma ray energy are investigated by analyzing the gamma ray activities of the radioactive sources.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Performance of the prototype LaBr{sub 3} spectrometer developed for the JET gamma-ray camera upgrade

In this work, we describe the solution developed by the gamma ray camera upgrade enhancement project to improve the spectroscopic properties of the existing JET γ-ray camera. Aim of the project is to enable gamma-ray spectroscopy in JET deuterium-tritium plasmas. A dedicated pilot spectrometer based on a LaBr{sub 3} crystal coupled to a silicon photo-multiplier has been developed. A proper pole zero cancellation network able to shorten the output signal to a length of 120 ns has been implemented allowing for spectroscopy at MHz count rates. The system has been characterized in the laboratory and shows an energy resolution of 5.5% at E{sub γ} = 0.662 MeV, which extrapolates favorably in the energy range of interest for gamma-ray emission from fast ions in fusion plasmas.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The RHIC p-Carbon CNI Polarimeter Upgrade For The Beam Polarization And Intensity Measurements

Proton polarization measurements in the AGS and RHIC (Relativistic Heavy Ion Collider at the beam energies 24-250 GeV) are based on proton-carbon and proton-proton elastic scattering in the Coulomb Nuclear Interference (CNI) region. Polarimeter operation in the scanning mode also gives polarization profile and beam intensity profile (beam emittance) measurements. Bunch by bunch emittance measurement is a very powerful tool for machine setup. Presently, the polarization and beam intensity profile measurements (in both vertical and horizontal planes) are restricted by the long target switching time and possible target destruction during this complicated motion. The RHIC polarimeters were operated near the limit of the counting rate for present silicon strip detectors. The ongoing polarimeter upgrade for the 2009 run will address all these problems. The upgrade should allow significant reduction of the polarization measurement errors by making feasible the complete polarization measurements, which includes polarization profiles in both the horizontal and vertical planes.

43 PARTICLE ACCELERATORS↗

Performance of Canberra TruckScan Waste Assay Measurement System - 16361

After the Fukushima accident, large (approximately cubic meter) super-sacks of potentially contaminated soil and vegetation were stored at various temporary locations throughout the prefecture. Canberra has developed the TruckScan system to perform rapid and accurate assay measurements for these waste sacks loaded on trucks to determine the individual and total sack activities for Cs-137 and Cs-134. The measurement system consists of eight 3x3 inch shielded and collimated NaI(Tl) gamma-ray detectors. Data collected with the eight detectors is analyzed using a maximum entropy fitting algorithm which optimizes and predicts the mean and maximum possible activity concentration present in each of the sacks. The algorithm uses SuperISOCS to generate detection efficiencies for each detector-sack combination in the measurement, which are then used to solve for the distribution of activity concentrations in each sack that yields the best agreement with the count rates observed in each detector. Throughout the summer and fall of 2015, a prototype system was developed and tested at Canberra's Meriden CT facility. In October 2015, the prototype system was installed and demonstrated in Japan. Results of the demonstration measurements are presented along with estimates of the total measurement uncertainty (TMU) budget. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Characterization Techniques for LiInSe{sub 2} Semiconducting Neutron Detector - Paper 55

As the world supply of helium continues to dwindle, alternatives to neutron detection have been a key focus area of radiation detection research. Solid-state neutron detectors are one possible alternative to the {sup 3}He detectors currently used for neutron detection when large detector areas are not required. Although {sup 6}Li and {sup 10}B are both also commonly used for neutron detection, neither has as high of a thermal cross section as {sup 3}He. The thermal cross sections for {sup 6}Li, {sup 10}B, and {sup 3}He are, respectively, 940 barns, 3840 barns, and 5330 barns. Both boron and helium are used in a gaseous form for neutron detection; however, there is no suitable gaseous form of lithium for neutron detection. Lithium is instead utilized in solid or liquid compounds for neutron detection. In this context, one area of interest is in the development of ternary A{sup I}B{sup III}C{sup IV} semiconductors comprised of isotopically-enriched lithium. Single crystal samples are being prepared through collaboration with the Y12 National Security Complex. This research focuses on the characterization of {sup 6}LiInSe{sub 2} (LISe) crystals, as well as on the development of prototype systems to assess the viability of using LISe crystals as a thermal neutron detector. Data to be obtained will provide previously untested physical parameters to facilitate growth optimization. Eventually, the refined crystals will be developed into solid-state, position-sensitive pixel detectors used for neutron imaging, among a wide array of possible applications including nuclear forensics. For the most part, the research team has been focused on mastering the detector fabrication processes, response tests on the first two batches of crystal samples, and the design of the first iteration detection system (Fig. 2). Response tests using alphas and neutrons have shown sensitivity to both particles. The first iteration detection system developed utilizes a 3-stage filter ladder of resistors and capacitors, similar to an ORTEC 142PC Preamplifier. Ideally, this ladder will reduce the noise associated with the high voltage power supply. The preamplifier is AC coupled to improve its counting rate capability (saturation), and critical components are on insulated posts. The custom circuit is housed in an aluminum box, and initial testing of the circuit has shown expected results. Investigation into further noise reduction is underway and will be the focus of the presented results. Upon completion and successful testing of the final detection system design, further development in spatial resolution and gamma/neutron discrimination will continue. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Gallium oxide semiconductor-based large volume ultrafast radiation hard spectroscopic scintillators

We report on the development of the first-ever inorganic radiation-hard moisture-insensitive large volume spectroscopic semiconductor-based scintillator with less than 2 ns decay time and light yields as high as 8000 ph/MeV. Despite extensive research into scintillator materials, the quest for an ideal scintillator combining ultrafast decay times (akin to BaF 2 and Yb-doped scintillators such as Lu 2 O 3 :Yb), high light yields (exceeding 2000 photons per MeV), spectroscopic capabilities, and exceptional radiation hardness remain unfulfilled. In this study, we demonstrate and report for the first time the viability of large-volume (up to 20 mm thickness) gallium oxide (β-Ga 2 O 3 ) semiconductor-based scintillators for applications requiring these properties. These β-Ga 2 O 3 scintillators were grown using the fast turnaround (~2 days) crucible-free optical float zone (FZ) technique. The high light yield and ultrafast decay time of these high-purity n-type semiconductors with free carrier concentration of 6 × 10 17 cm –3 are attributed to native defects, specifically oxygen vacancies (V O ) and gallium–oxygen vacancy pairs (V Ga –V O ), generated during optimized FZ growth. The ultrafast decay, along with high light yield, enables excellent timing resolution and high count rate detection for applications like time-of-flight positron emission tomography, physics experiments, and nuclear safety. The radiation hardness of these devices has been documented in a separate publication.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

The X-ray luminosity function of M37 and the evolution of coronal activity in low-mass stars

We use a 440.5 ks Chandra observation of the ≈500 Myr old open cluster M37 to derive the X-ray luminosity functions of its ≤1.2 M{sub ⊙} stars. Combining detections of 162 M37 members with upper limits for 160 non-detections, we find that its G, K, and M stars have a similar median (0.5–7 keV) X-ray luminosity L{sub X}=10{sup 29.0} erg s{sup −1}, whereas the L{sub X}-to-bolometric-luminosity ratio (L{sub X}/L{sub bol}) indicates that M stars are more active than G and K stars by ≈1 order of magnitude at 500 Myr. To characterize the evolution of magnetic activity in low-mass stars over their first ≈600 Myr, we consolidate X-ray and optical data from the literature for stars in six other open clusters: from youngest to oldest they are, the Orion Nebula Cluster (ONC), NGC 2547, NGC 2516, the Pleiades, NGC 6475, and the Hyades. For these, we homogenize the conversion of instrumental count rates to L{sub X} by applying the same one-temperature emission model as for M37, and obtain masses using the same empirical mass-absolute magnitude relation (except for the ONC). We find that for G and K stars X-ray activity decreases ≈2 orders of magnitude over their first 600 Myr, and for M stars, ≈1.5. The decay rate of the median L{sub X} follows the relation L{sub X}∝ t{sup b}, where b=−0.61±0.12 for G stars, −0.82 ± 0.16 for K stars, and −0.40 ± 0.17 for M stars. In L{sub X}/L{sub bol} space, the slopes are −0.68 ± 0.12, −0.81 ± 0.19, and −0.61 ± 0.12, respectively. These results suggest that for low-mass stars the age-activity relation steepens after ≈625 Myr, consistent with the faster decay in activity observed in solar analogs at t>1 Gyr.

79 ASTRONOMY AND ASTROPHYSICS↗

TIME SERIES MODELS OF THREE SETS OF RXTE OBSERVATIONS OF 4U 1543-47

The X-ray nova 4U 1543-47 was in a different physical state (low/hard, high/soft, and very high) during the acquisition of each of the three time series analyzed in this paper. Standard time series models of the autoregressive moving average (ARMA) family are fitted to these series. The low/hard data can be adequately modeled by a simple low-order model with fixed coefficients, once the slowly varying mean count rate has been accounted for. The high/soft series requires a higher order model, or an ARMA model with variable coefficients. The very high state is characterized by a succession of 'dips', with roughly equal depths. These seem to appear independently of one another. The underlying stochastic series can again be modeled by an ARMA form, or roughly as the sum of an ARMA series and white noise. The structuring of each model in terms of short-lived aperiodic and 'quasi-periodic' components is discussed.

79 ASTRONOMY AND ASTROPHYSICS↗

Photon Regeneration Experiment for Axion Search Using X-Rays

In this Letter we describe our novel photon regeneration experiment for the axionlike particle search using an x-ray beam with a photon energy of 50.2 and 90.7 keV, two superconducting magnets of 3 T, and a Ge detector with a high quantum efficiency. A counting rate of regenerated photons compatible with zero has been measured. The corresponding limits on the pseudoscalar axionlike particle-two-photon coupling constant is obtained as a function of the particle mass. Our setup widens the energy window of purely terrestrial experiments devoted to the axionlike particle search by coupling to two photons. It also opens a new domain of experimental investigation of photon propagation in magnetic fields.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

High-Resolution Hypernuclear Spectroscopy Electron Scattering at Jlab, Hall A

Hypernuclear spectroscopy via electromagnetic induced reactions is a valuable and powerful way to study hypernuclei, hadronic systems with non-zero strangeness content, providing an alternative to the hadron induced reactions mainly studied so far. Electron-induced hypernuclear spectroscopy has been studied in Hall A at Jefferson Lab on three nuclei, 12C, 16O, and 9Be with unprecedented resolution and with an improved particle identification system, using a RICH detector, in order to unambiguously identify kaons, thus allowing the measurement of high-quality, almost background-free, hypernuclear spectra. Two superconducting septum magnets were added to the existing apparatus in order to permit particle detection at very forward angle providing a reasonable counting rate. These studies have provided the first quantitative information on, for instance, core-excited states in hypernuclei. In the case of oxygen, a waterfall target has been employed allowing for the simultaneous measurement of hypernuclear production on oxygen and of elementary kaon-Lambda electro-production on protons: a crucial measurement to disentangle the contribution of the elementary reaction from the measured hypernuclear production cross section, yielding direct access to the nucleus-hypernucleus transition structure. Final results for 12C and 16O as well as preliminary results on 9Be will be presented.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Single crystal diamond detector measurements of deuterium-deuterium and deuterium-tritium neutrons in Joint European Torus fusion plasmas

First simultaneous measurements of deuterium-deuterium (DD) and deuterium-tritium neutrons from deuterium plasmas using a Single crystal Diamond Detector are presented in this paper. The measurements were performed at JET with a dedicated electronic chain that combined high count rate capabilities and high energy resolution. The deposited energy spectrum from DD neutrons was successfully reproduced by means of Monte Carlo calculations of the detector response function and simulations of neutron emission from the plasma, including background contributions. The reported results are of relevance for the development of compact neutron detectors with spectroscopy capabilities for installation in camera systems of present and future high power fusion experiments.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗