Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “COSMIC PROTONS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 541 records · Page 30

Improved cross section calculations for astrophysical applications

Modifications are proposed for the semiempirical equations and parameters of Silberberg and Tsao (1973) for partial cross section calculations of proton-nucleus reactions in cosmic rays. These modifications include: adjustment of general parameters; modification of energy dependence; effects of nuclear alpha-particle structure, deuteron emission, and even-charged products; peripheral reactions; fission reactions; averaging cross sections near boundaries of different parameters; elimination of certain special cases; and treatment of the Pt to Pb group that cannot yet be generalized to Z(t) less than 76.

Silberberg, R.↗

The international cometary explorer mission to comet Giacobini-Zinner

The encounter, on September 11, 1985, between the International Cometary Explorer (ICE) and the comet Giacobini-Zinner, is described in detail. The primary goal of this encounter was to study the interaction between the solar wind and the comet. At the time of the encounter, the spacecraft was approximately 50 times farther from the earth than it was designed to go, making it difficult to recover data. The seven instruments on board ICE which were operational in this mission were the plasma electron, magnetometer, plasma waves, radio waves, plasma composition, low-energy cosmic ray, and energetic proton instruments. The encounter is depicted schematically, showing the times different regions were crossed. The spacecraft velocity vector, measured relative to the comet, made a 93 deg angle with respect to the plasma tail axis. The spacecraft crossed the center of the comet ion tail at approximately 1102 U.T. A cold, dense plasma was found near the center of the tail; at the very center was a temperature reading of only 13,000 K and a density of 670 electrons/cu cm. Alfven's model of comet tail formation was confirmed and it was found that water group ions are the dominant comet component. Pulses were detected which were attributed to dust particles hitting the spacecraft.

Von Rosenvinge, T. T.↗

Measurements of background gamma radiation on Spacelab 2

A nuclear radiation monitor (NRM) which was flown as part of the verification instrumentation on the Spacelab 2 mission (July 29 - August 6, 1985) recorded spectra every 20 seconds and counting rates in coarse energy bands on finer time scales. The gamma radiation environment on Spacelab is characterized by cosmic-ray and trapped proton secondary radiation in the Spacelab/Shuttle, earth albedo radiation, and delayed induced radioactivity in the detector and surrounding materials. It is found that passages through South Atlantic Anomaly protons produce a well-defined background enhancement.

Fishman, G. J.↗

Trace element abundance determinations by Synchrotron X Ray Fluorescence (SXRF) on returned comet nucleus mineral grains

Trace element analyses were performed on bulk cosmic dust particles by Proton Induced X Ray Emission (PIXE) and Synchrotron X Ray Fluorescence (SXRF). When present at or near chondritic abundances the trace elements K, Ti, Cr, Mn, Cu, Zn, Ga, Ge, Se, and Br are presently detectable by SXRF in particles of 20 micron diameter. Improvements to the SXRF analysis facility at the National Synchrotron Light Source presently underway should increase the range of detectable elements and permit the analysis of smaller samples. In addition the Advanced Photon Source will be commissioned at Argonne National Laboratory in 1995. This 7 to 8 GeV positron storage ring, specifically designed for high-energy undulator and wiggler insertion devices, will be an ideal source for an x ray microprobe with one micron spatial resolution and better than 100 ppb elemental sensitivity for most elements. Thus trace element analysis of individual micron-sized grains should be possible by the time of the comet nucleus sample return mission.

Flynn, G. J.↗

Gamma-ray observations of the Galactic center - Removing the Galactic ridge contribution

Spectral measurements of the emission from the disk of the Galaxy from keV to GeV energies are combined. It is found that this emission has a similar spatial distribution at all energies: a longitude extent of about +/-40 deg and a latitude extent of about less than 5 deg. The emission over most of the energy range is dominated by cosmic-ray electrons and protons interacting with interstellar matter. The ridge spectrum is estimated to be near 100 keV using observations by HEAO A-4 from 1977 to 1979. To determine the emission from point sources in the region the diffuse component is substracted from Galactic center observations made by wide-field gamma-ray instruments over the past 20 years. The Galactic ridge accounts for between one-third and one-half of the observed flux for most of the measurements. Substracting the diffuse emission and GRS 1758-258 emission from the HEXAGONE observations on May 22 gives a spectrum that is dominated by lines from positron annihilation.

Gehrels, Neil↗

Concepts and strategies for lunar base radiation protection - Prefabricated versus in-situ materials

The most recently accepted environment data are used as inputs for the Langley nucleon and heavy-ion transport codes, BRYNTRN and HZETRN, to examine the shield effectiveness of lunar regolith in comparison with commercially-used shield materials in nuclear facilities. Several of the fabricated materials categorized as neutron absorbers exhibit favorable characteristics for space radiation protection. In particular, polyethylene with additive boron is analyzed with regard to response to the predicted lunar galactic cosmic ray and solar proton flare environment during the course of a complete solar cycle. Although this effort is not intended to be a definitive trade study for specific shielding recommendations, attention is given to several factors that warrant consideration in such trade studies. For example, the transporting of bulk shield material to the lunar site as opposed to regolith-moving and processing equipment is assessed on the basis of recent scenario studies. The transporting of shield material from Earth may also be a viable alternative to the use of regolith from standpoints of cost-effectiveness, EVA time required, and risk factor.

Simonsen, Lisa C.↗

STRV RADMON: An integrated high-energy particle detector

The RADMON (Radiation Monitor) was developed as a compact device with a 4-kbit SRAM particle detector and two p-FET total dose monitors. Thus it can be used as a spacecraft radiation alarm and in situ total dose monitor. This paper discusses the design and calibration of the SRAM for proton, alpha, and heavy ion detection. Upset rates for the RADMON, based on a newly developed space particle flux algorithm, are shown to vary over eight orders of magnitude. On the STRV (Space Technology Research Vehicle) the RADMON's SRAM will be used to detect trapped protons, solar flares, and cosmic rays and to evaluate our ability to predict space results from ground tests.

Buehler, Martin↗

Gamma-ray observations of Ophiuchus with EGRET: The diffuse emission and point sources

Observations of the Ophiuchus region made with the Energetic Gamma-Ray Experiment Telescope (EGRET) on the Compton Gamma Ray Observatory (CGRO) during the first 2 1/2 years of operation show the diffuse emission from the interstellar gas in Ophiuchus as well as variable emission from two point sources. The gamma-ray emission is modeled in terms of cosmic-ray interactions with atomic and molecular hydrogen in Ophiuchus and with low-energy photons along the line of sight. The model also includes the flux from the two point sources and an isotropic diffuse contribution. The cosmic-ray density is assumed to be uniform. The derived ratio of molecular hydrogen column density to integrated CO intensity is (1.1 +/- 0.2) x 10(exp 20) H-mols/sq cm (K km/s)(exp -1). At the sensitivity and resolution of the gamma-ray data, no variation of this ratio over the modeled region is discernible, nor are any regions of enhanced cosmic-ray density apparent. The model was fitted to seven narrow energy bands to obtain the energy depedence of the gamma-ray production function and the spectra of the point sources. The derived production function is in good agreement with theoretical calculations and the local cosmic-ray electron and proton spectra. The positions of the point sources were determined from maximum likelihood analysis of the gamma-ray emission observed in excess of the diffuse model. We identify one point source with the quasar PKS 1622-253, which has an average flux, E greater than 100 MeV, of (2.5 +/- 0.5) x 10(exp -7) photons/sq cm/s and photon spectral index -1.9 +/- 0.3. The other source, denoted GRO J1631-27, has not yet been identified at other wavelengths. Its average flux, E greater than 100 MeV, is (1.1 +/- 0.4) x 10(exp -7) photons/sq cm/s; however, its spectral index is poorly determined. The spectral index and intensity of the isotropic contribution to the model agree well with the extragalactic diffuse emission derived from the SAS 2 data.

Hunter, S. D.↗

Low cost spacecraft computers: Oxymoron or future trend?

Over the last few decades, application of current terrestrial computer technology in embedded spacecraft control systems has been expensive and wrought with many technical challenges. These challenges have centered on overcoming the extreme environmental constraints (protons, neutrons, gamma radiation, cosmic rays, temperature, vibration, etc.) that often preclude direct use of commercial off-the-shelf computer technology. Reliability, fault tolerance and power have also greatly constrained the selection of spacecraft control system computers. More recently, new constraints are being felt, cost and mass in particular, that have again narrowed the degrees of freedom spacecraft designers once enjoyed. This paper discusses these challenges, how they were previously overcome, how future trends in commercial computer technology will simplify (or hinder) selection of computer technology for spacecraft control applications, and what spacecraft electronic system designers can do now to circumvent them.

Manning, Robert M.↗

Atmospheric Ionization by Solar Particles Detected by Nitrate Measurements in Antarctic Snow. FY91 AASERT

The odd nitrogen source strengths associated with Solar Proton Events (SPEs), Galactic Cosmic Rays (GCRs), and the oxidation of nitrous oxide in the Earth's middle atmosphere from 1974 through 1993 have been compared globally, at middle and lower latitudes (less than 50 deg), and polar regions (greater than 50 deg) with a two-dimensional (2-D) photochemical transport model. As discovered previously, the oxidation of nitrous oxide dominates the global odd nitrogen source while GCRs and SPEs are significant at polar latitudes. The horizontal transport of odd nitrogen, produced by the oxidation of nitrous oxide at latitudes < 50 deg, was found to be the dominant source of odd nitrogen in the polar regions with GCRs contributing substantially during the entire solar cycle. The source of odd nitrogen from SPEs was more sporadic; however, contributions during several years (mostly near solar maximum) were significant in the polar middle atmosphere.

Vitt, Francis M.↗

EGRET Observations of the Diffuse Gamma-Ray Emission in Orion: Analysis Through Cycle 6

We present a study of the high-energy diffuse emission observed toward Orion by the Energetic Gamma-Ray Experiment Telescope (EGRET) on the Compton Gamma-Ray Observatory. The total exposure by EGRET in this region has increased by more than a factor of two since a previous study. A simple model for the diffuse emission adequately fits the data; no significant point sources are detected in the region studied (1 = 195 deg to 220 deg and b = -25 deg to -10 deg) in either the composite dataset or in two separate groups of EGRET viewing periods considered. The gamma-ray emissivity in Orion is found to be (1.65 +/- 0.11) x 10(exp -26)/s.sr for E > 100 MeV, and the differential emissivity is well-described as a combination of contributions from cosmic-ray electrons and protons with approximately the local density. The molecular mass calibrating ratio is N(H2)/W(sub CO) = (1.35 +/- 0.15) x 10(exp 20)/sq cm.(K.km/s).

Digel, S. W.↗

In-Situ Spectrometry of Neutrons

High energy charged particles of extra-galactic, galactic and solar origin collide with spacecraft structures in Earth orbit outside the atmosphere and in interplanetary travel beyond the Earth's magnetosphere. These primaries create a number of secondary particles inside the structures that can produce a significant ionizing radiation environment. This radiation is a threat to long term inhabitants or travelers for space missions and produces an increased risk of cancer and DNA damage. The primary high energy cosmic rays and trapped protons collide with common spacecraft materials such as aluminum and silicon and create secondary particles inside structures that are mostly protons and neutrons. Charged protons are readily detected and instruments are already in existence for this task. Neutrons are electrically neutral and therefore much more difficult to measure and detect. These neutrons are reported to contribute 30-60% of the dose inside space structures and cannot be ignored. Currently there is no compact, portable and real time neutron detector instrumentation available for use inside spacecraft or on planetary surfaces where astronauts will live and work. We propose to design and build a portable, low power and robust neutron spectrometer that will measure the neutron spectrum from 10 KeV to 500 MeV with at least 10% energy resolution in the various energy intervals. This instrument will monitor the existing neutron environment both inside spacecraft structures and on planetary surfaces to determine the safest living areas, warn of high fluxes associated with solar storms and assist the NSBRI Radiation Effects Team in making an accurate assessment of increased cancer risk and DNA damage to astronauts. The instrument uses a highly efficient proportional counter Helium 3 tube at the lowest energy intervals where .equivalent damage factors for tissue are the highest (10 KeV-2 MeV). The Helium 3 tube may be shielded with a cadmium absorber to eliminate the much less damaging, but more prevalent, thermal and epithermal neutrons and to make the structure of the spectrum more accurate in the 20 KeV-2 MeV range; or a pair of tubes, one shielded and one unshielded, can be combined so that the difference in their counts yields the thermal neutron contribution. The spectrometer also uses a 5mm lithium drifted bulk silicon solid state detector in the medium energy range of 2-20 Mev and two standard silicon surface barrier detectors separated by tens of millimeters behind a I cm thick polyethylene moderator in a stack or telescope arrangement for the high energy neutrons (>20 MeV). In the medium and high energy regions equivalent damage factors are lower but hits from one or a small number of neutrons may prove to be important. The silicon detector systems for medium and high energy neutrons will discriminate against charged particles by using a plastic cesium iodide scintillator of an appropriate geometry monitored by a silicon PIN photodiode.

Maurer, Richard H.↗

Numerical Simulations of Cosmogenic Neutron Production and Transport in Planetary Surfaces

The numerical simulation code MCNPX was used to calculate the production and transport of cosmic-ray-produced neutrons in Mars and meteorites. These calculations help to understand the processes involved and the parameters that control the neutron fluxes. Results are presented here for neutrons in Mars and for the distribution of cosmic-ray neutrons and protons in a 50 cm-radius L-chondrite.

Kim, Kyeong J.↗

Fundamental space radiobiology

The unique feature of the space radiation environment is the dominance of high-energy charged particles (HZE or high LET radiation) emitted by the Sun and galactic sources, or trapped in the Van Allen radiation belts. These charged particles present a significant hazard to space flight crews, and accelerator-based experiments are underway to quantify the health risks due to unavoidable radiation exposure. There are three principal properties of charged particles that distinguish them from conventional radiation, i.e. gamma rays and x-rays. First, they have a defined range in matter rather than an exponential absorption profile. Second, they undergo nuclear reactions to produce secondary particles. Third, and most important, they deposit their energy along well-defined linear paths or tracks rather than diffuse fields. The structured energy deposition pattern interacts on multiple scales with the biological structures of DNA, cells and tissues to produce correlated patterns of damage that evade repair systems. Traditional concepts of dose and its associated normalization parameter, RBE (relative biological effectiveness), break down under experimental scrutiny, and probabilistic models of risk based on the number of particle traversals per cell may be more appropriate. Unique patterns of DNA damage, gene expression, mobilization of repair proteins, activation of cytokines and remodeling of cellular microenvironment are observed following exposure to high LET radiation. At low levels of exposure the communication of bioactive substances from irradiated to unirradiated "bystander" cells can amplify the damage and cause a significant deviation from linearity in dose vs. response relations. Under some circumstances, there is even a multigenerational delay in the expression of radiation-induced genetic damage (genomic instability) which is not strictly dose dependent. These issues and the experimental evidence derived from ground based experiments at particle accelerators are presented along with speculation about how modified inertial conditions might perturb homeostatic responses to radiation to further complicate risk assessment for space flight.

NASA Discipline Radiation Health↗

Radiation dosimetry measurements with real time radiation monitoring device (RRMD)-II in Space Shuttle STS-79

The real-time measurement of radiation environment was made with an improved real-time radiation monitoring device (RRMD)-II onboard Space Shuttle STS-79 (S/MM#4: 4th Shuttle MIR Mission, at an inclination angle of 51.6 degrees and an altitude of 250-400km) for 199 h during 17-25 September, 1996. The observation of the detector covered the linear energy transfer (LET) range of 3.5-6000 keV/micrometer. The Shuttle orbital profile in this mission was equivalent to that of the currently planned Space Station, and provided an opportunity to investigate variations in count rate and dose equivalent rate depending on altitude, longitude, and latitude in detail. Particle count rate and dose equivalent rate were mapped geographically during the mission. Based on the map of count rate, an analysis was made by dividing whole region into three regions: South Atlantic Anomaly (SAA) region, high latitude region and other regions. The averaged absorbed dose rate during the mission was 39.3 microGy/day for a LET range of 3.5-6000 keV/micrometer. The corresponding average dose equivalent rates during the mission are estimated to be 293 microSv/day with quality factors from International Commission on Radiological Protection (ICRP)-Pub. 60 and 270 microSv/day with quality factors from ICRP-Pub. 26. The effective quality factors for ICRP-Pub. 60 and 26 are 7.45 and 6.88, respectively. From the present data for particles of LET > 3.5keV/micrometer, we conclude that the average dose equivalent rate is dominated by the contribution of galactic cosmic ray (GCR) particles. The dose-detector depth dependence was also investigated.

manned↗

HZE beam transport in multilayered materials

A nonperturbative analytic solution of the high charge and energy (HZE) Green's function is used to implement a computer code for laboratory ion beam transport in multiple-layered materials. The code is established to operate on the Langley nuclear fragmentation model used in space engineering applications. Computational procedures are established to generate linear energy transfer (LET) distributions for a specified ion beam and target for comparison with experimental measurement. Comparison with 56Fe ion with Pb-Al and Pb-(CH2)x targets shows reasonable agreement.

NASA Discipline Radiation Health↗

Single Particle Damage Events in Candidate Star Camera Sensors

Si charge coupled devices (CCDs) are currently the preeminent detector in star cameras as well as in the near ultraviolet (uv) to visible wavelength region for astronomical observations in space and in earth-observing space missions. Unfortunately, the performance of CCDs is permanently degraded by total ionizing dose (TID) and displacement damage effects. TID produces threshold voltage shifts on the CCD gates and displacement damage reduces the charge transfer efficiency (CTE), increases the dark current, produces dark current nonuniformities and creates random telegraph noise in individual pixels. In addition to these long term effects, cosmic ray and trapped proton transients also interfere with device operation on orbit. In the present paper, we investigate the dark current behavior of CCDs - in particular the formation and annealing of hot pixels. Such pixels degrade the ability of a CCD to perform science and also can present problems to the performance of star camera functions (especially if their numbers are not correctly anticipated). To date, most dark current radiation studies have been performed by irradiating the CCDs at room temperature but this can result in a significantly optimistic picture of the hot pixel count. We know from the Hubble Space Telescope (HST) that high dark current pixels (so-called hot pixels or hot spikes) accumulate as a function of time on orbit. For example, the HST Advanced Camera for Surveys/Wide Field Camera instrument performs monthly anneals despite the loss of observational time, in order to partially anneal the hot pixels. Note that the fact that significant reduction in hot pixel populations occurs for room temperature anneals is not presently understood since none of the commonly expected defects in Si (e.g. divacancy, E center, and A-center) anneal at such a low temperature. A HST Wide Field Camera 3 (WFC3) CCD manufactured by E2V was irradiated while operating at -83C and the dark current studied as a function of temperature while the CCD was warmed to a sequence of temperatures up to a maximum of +30C. The device was then cooled back down to -83 and re-measured. Hot pixel populations were tracked during the warm-up and cool-down. Hot pixel annealing began below 40C and the anneal process was largely completed before the detector reached +3OC. There was no apparent sharp temperature dependence in the annealing. Although a large fraction of the hot pixels fell below the threshold to be counted as a hot pixel, they nevertheless remained warmer than the remaining population. The details of the mechanism for the formation and annealing of hot pixels is not presently understood, but it appears likely that hot pixels are associated with displacement damage occurring in high electric field regions.

Marshall, Paul↗

Simulation of the ATIC-2 Silicon Matrix for Protons and Helium GCR Primaries at 0.3, 10, and 25 TeV/Nucleon

The energy deposition distribution for protons and helium galactic cosmic ray primaries at 0.3, 10, and 25 TeV/nucleon in the ATIC-2 silicon matrix detector are simulated with GEANT4. The GEANT3 geometrical model of ATIC developed by the University of Maryland was combined with a GEANT4 application developed for the Deep Space Test Bed (DSTB) detector package. The new code included relatively minor modifications to completely describe the ATIC materials and a more detailed model of the Silicon Matrix detector. For this analysis all particles were started as a unidirectional beam at a single point near the center of the Silicon Matrix front surface. The point was selected such that each primary passed through at least two of the overlapping silicon pixels.

Watts, J.↗