Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “COMPRESSION TESTING”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 541 records · Page 30

Self‐Healing of Concrete Cracks by Ceramsite‐Loaded Microorganisms

Protective carrier is essential for the self‐healing of concrete cracks by microbially induced CaCO 3 precipitation, owing to the harsh conditions in concrete. In this paper, porous ceramsite particles are used as microbial carrier. Heat treatment and NaOH soaking are first employed to improve the loading content of the ceramsite. The viability of bacterial spores is assessed by urea decomposition measurements. Then, the self‐healing efficiency of concrete cracks by spores is evaluated by a series of tests including compressive strength regain, water uptake, and visual inspection of cracks. Results indicate that heat treatment can improve the loading content of ceramsite while not leading to a reduction of concrete strength by the ceramsite addition. The optimal heating temperature is 750°C. Ceramsite particles act as a shelter and protect spores from high‐pH environment in concrete. When nutrients and spores are incorporated in ceramsite particles at the same time, nutrients are well accessible to the cells. The regain ratio of the compressive strength increases over 20%, and the water absorption ratio decreases about 30% compared with the control. The healing ratio of cracks reaches 86%, and the maximum crack width healed is near 0.3 mm.

Xu, Jing↗

CSR behavior and aging model for the Viton© Fluorelastomer O-rings in the 9975 shipping package

The 9975 Type B shipping package is used within the DOE complex for shipping special nuclear materials. This package is re-certified annually in accordance with Safety Analysis Report for Packaging (SARP) requirements. The package is also used at the Savannah River Site as part of the long-term storage configuration of special nuclear materials. As such, the packages do not undergo annual recertification during storage, with uncertainty as to how long some of the package components will meet their functional requirements in the storage environment. The packages are currently approved for up to 15 years storage, and work continues to provide a technical basis to extend that period. This report describes efforts by the Savannah River National Laboratory (SRNL) to extend the service life estimate of Viton® GLT and GLT-S fluoroelastomer O-rings used in the 9975 shipping package. O-rings of both GLT and GLT-S compositions are undergoing accelerated aging at elevated temperature, and are periodically tested for compression stress relaxation (CSR) behavior. The CSR behavior of O-rings was evaluated at temperatures from 175 to 400 °F. These collective data were used to develop predictive models for extrapolation of CSR behavior to relevant service temperatures (< 156 °F). The predictive model developed from the CSR data conservatively indicates a service life of approximately 37 years for Viton GLT O-rings at the maximum effective service temperature of 156 °F. The estimated service life for Viton GLT-S O-rings is significantly longer.

36 MATERIALS SCIENCE↗

SAVY-4000 O-Ring and Filter Lifetime Extension Report

The 3-year accelerated aging study of the SAVY-4000 O-ring detailed in our previous Lifetime Extension Report showed very little evidence of significant degradation to samples subjected to aggressive elevated temperature and radiation conditions. Whole container thermal aging studies followed by helium leakage testing and compression set measurements were used to establish a failure criterion estimate for O-ring compression set of ≥ 65 %, which led to an O-ring lifetime estimate of greater than 65 years at 80°C. Herein, we describe a statistical model of the 3-year accelerated aging study and present additional results gathered in FY17 that further support the lifetime extension of the O-ring to 40 years at 80°C. Because we are choosing an extremely conservative lifetime value (40 years) compared to the aging study results (>65 years), the O-ring lifetime could be extended further, especially if supported by surveillance results collected over the years to come.

36 MATERIALS SCIENCE↗

Cost-efficient temperature mediation of DPMS synthesis in flow using continuous flow chemistry

An efficient synthesis of diphenylmethylsilanol (DPMS) utilizing continuous flow chemistry was performed using a coil reactor and an ice bath. The inclusion of careful temperature control minimized the exothermic production of an unwanted dimer. Yields of up to 88% were obtained and dimer formation as low as 2.2% was confirmed by NMR. This material will be used in the formulation to make SX358 and its physical and chemical characteristics will be determined using DSC, DMA, TMA, compression set testing and FTIR.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Embedded Sensing in Additive Manufacturing Metal and Polymer Parts: A Comparative Study of Integration Techniques and Structural Health Monitoring Performance

This study presents a comparative evaluation of post-process sensor integration in additively manufactured (AM) metal and the in-situ process for polymer structures for structural health monitoring (SHM), with an emphasis on embedded sensors. Geometrically identical specimens were fabricated using copper via metal fused filament fabrication (FFF) and PLA via polymer FFF, with piezoelectric transducers (PZTs) inserted into internal cavities to assess the influence of material and placement on sensing fidelity. Mechanical testing under compressive and point loads generated signals that were transformed into time–frequency spectrograms using a Short-Time Fourier Transform (STFT) framework. An engineered RGB representation was developed, combining global amplitude scaling with an amplitude-envelope encoding to enhance contrast and highlight subtle wave features. These spectrograms served as inputs to convolutional neural networks (CNNs) for classification of load conditions and detection of damage-related features. Results showed reliable recognition in both copper and PLA specimens, with CNN classification accuracies exceeding 95%. Embedded PZTs were especially effective in PLA, where signal damping and environmental sensitivity often hinder surface-mounted sensors. This work demonstrates the advantages of embedded sensing in AM structures, particularly when paired with spectrogram-based feature engineering and CNN modeling, advancing real-time SHM for aerospace, energy, and defense applications.

additive manufacturing↗

Probability of Pinching Failure in PWR SNF after Long-Term Storage

A probabilistic assessment was performed on pinching failure of PWR SNF rod cladding under accidental SNF cask transport conditions. a set of 3,000 rod pinching scenarios was analyzed, with different geometrical, material, and loading parameters, using a Latin Hypercube Sampling (LHS). The investigated accidents include train derailments leading to cask collisions or cask drops. Pinching failure was related to cladding offset strain, defined as the plastic deformation interval in radial cladding direction normalized with respect to the outer cladding diameter. Finite element (FE) models were used to compute SNF rod deformations and the offset strain demand OSD in each of the assessed pinching scenarios. The numerical models account for the contribution of the degraded fuel pellets to rod pinching stiffness. The offset strain capacity OSC was computed using regression and interpolation models based on ring compression (RCT) test results, and account for hydride-related effects on cladding ductility. The results show a low probability of pinching failure. Hydride-related cladding embrittlement affects the structural integrity of PWR SNF rods after long-term dry storage of up to 300 years. Radial hydride patterns or large amounts of circumferentially oriented hydrides reduce the cladding ductile deformation capability when pinched at low material temperatures. The probability of hydride-related pinching failure of PWR cladding is estimated after long-term dry storage to address: How do PWR SNF rod conditions like hydrogen content, vacuum drying peak cladding hoop stress σ{sub θ}, and cladding material temperature affect cladding ductility? Is hydride-related cladding embrittlement a material degradation mechanism that affects the structural integrity of PWR SNF rods under pinching loading? What are the controlling parameters for deformation demands in PWR SNF rods under pinching loading? Is the pinching load amplitude an important parameter that controls the probability of pinching failure? How do parameters like pellet-cladding gap or fuel pellet degradation affect the pinching loading capacity of PWR SNF rods? Statistical modelling of PWR SNF rod conditions in U.S. inventory: A pseudo rod database was generated based on EIA database. Analysis of train accident scenarios: a probability density function (pdf) of a pinching load distribution P{sub 9m} of a 9-m cask drop is linearly scaled to generate a more representative: distribution P{sub AS}. The new distribution considers train collision velocities, cask drops for on- and off-bridge accidents, and cask impact orientation. LHS generates 3,000 rod pinching scenarios based on nine independent geometrical, material, and loading parameters. Probabilistic FE Analysis: The LHS realizations are used to generate 3,000 FE models. The FE analysis is conducted for P{sub 9m}, and P{sub AS}. The workflow is automatized. The OSC is computed with regression and interpolation models, as a function of the hydrogen content C{sub H}, vacuum drying peak σ{sub θ}, and SNF temperature T{sub FR}: The regression data was obtained in RCTs on PWR cladding. The OSD is derived from the cladding deformations in the FE models. Cladding failure was identified via a comparison of OSC and OSD. A 300 and a 30 years-of-dry-storage duration is investigated: The dry-storage period affects the expected SNF temperature and consequently, the OSC and the OSD. The material temperature LHS population is adapted to account for a SNF temperature variation. The probability of hydride-related, ductile cladding failure during a severe transportation accident is not significantly affected by the pinching load amplitude: The probability is slightly reduced from a range of less than 0.0333% to 0.1667% for P{sub 9m}, to a range of less than 0.0333% to 0.1333% for P{sub AS}, depending on the vacuum drying peak cladding hoop stress modelling assumptions. Further, the SNF dry-storage duration does not significantly affect the probability of ductile pinching failure. Based on available train accidents data, the pinching failure probability for a 5,000 km long transportation route ranges from less than 1.62 E-7 to a value of 6.47 E-7, depending on the vacuum drying peak cladding hoop stress modelling assumptions. The pinching load amplitude is not a controlling parameter for the probability of ductile cladding pinching failure, and does not control the cladding deformations once pellet-cladding contact is established, The pellet-cladding gap width, however, plays a key role. Fuel pellet degradation only affects the deformation capacity, if the pellet stiffness is significantly reduced (more than 90%). Only highly embrittled cladding is likely to fail. The deformation demands on the cladding under pinching loading are small.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Hanford single-shell tank sidewall coring Project - 15548

As part of an enhanced Single-Shell Tank (SST) integrity project, Washington River Protection Solutions, the US DOE Hanford site Tank Operations Contractor, established an expert panel to provide recommendations for implementation of the project. In one of the main areas of interest, structural integrity, the panel recommended obtaining and testing a vertical core from the entire depth of the sidewall for SSTs that have leaked and have been operated at high temperatures for extended periods. Due to concerns over handling contaminated samples, the panel later recommended that the evaluation focus only on thermal degradation. SST 241-A-106 was selected as the best choice for sidewall coring based on heat exposure and other factors. During site preparation activities, nondestructive testing and evaluation of the exposed tank dome and sidewall was performed using impact echo, spectral analysis of surface waves, and sonic echo/impulse response acoustic wave test methods. Good results were observed in the tests performed on the dome, but results were inconclusive for the full wall height due to signal damping. Results indicated that no cracking was predicted in the upper wall. Sidewall coring of tank A-106 was completed over two weeks in May 2014. Over 38 feet of concrete core was successfully removed, to a depth approximately halfway through the tank footing. Nondestructive and destructive physical testing of the concrete core specimens was successfully performed and included visual examination and determination of transverse and longitudinal resonant frequency and dynamic modulus of elasticity; pulse velocity; static modulus of elasticity; Poisson's ratio; and compressive strength. The testing indicated favorable results with values generally greater, and in many cases significantly greater, than expected in comparison with the values originally specified and those used in the current structural analysis of record. Petrographic analysis was performed to assess the quality and condition of the concrete and the extent of any deterioration or deleterious reactions occurring within the concrete, and determined that the concrete within the examined core segments is in overall good condition, with a minor amount of microcracking and minor evidence of deleterious mechanisms that do not appear to have significantly affected the overall quality and integrity of the concrete. The results of the testing performed on the concrete core removed from the sidewall of SST 241-A-106 do not reveal any deficiencies with the structural integrity of the tank. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Generation and Analysis of Subpicosecond Double Electron Bunch at the Brookhaven Accelerator Test Facility

Two compressed electron beam bunches from a single 60-MeV bunch have been generated in a reproducible manner during compression in the magnetic chicane - 'dog leg' arrangement at ATF. Measurements indicate they have comparable bunch lengths ({approx}100-200 fs) and are separated in energy by {approx}1.8 MeV with the higher-energy bunch preceding the lower-energy bunch by 0.5-1 ps. Some simulation results for analyzing the double-bunch formation process are also presented.

43 PARTICLE ACCELERATORS↗

Upgrade of the SLAC SLED II Pulse Compression System Based on Recent High Power Tests

In the Next Linear Collider (NLC) it is expected that the high power rf components be able to handle peak power levels in excess of 400 MW. We present recent results of high power tests designed to investigate the RF breakdown limits of the X-band pulse compression system used at SLAC. (SLED-II). Results of these tests show that both the TE{sub 01}-TE{sub 10} mode converter and the 4-port hybrid have a maximum useful power limit of 220-250 MW. Based on these tests, modifications of these components have been undertaken to improve their peak field handling capability. Results of these modifications will be presented. As part of an international effort to develop a new 0.5-1.5 TeV electron-positron linear collider for the 21st century, SLAC has been working towards a design, referred to as 'The Next Linear Collider' (NLC), which will operate at 11.424 GHz and utilize 50-75 MW klystrons as rf power sources. One of the major challenges in this design, or any other design, is how to generate and efficiently transport extremely high rf power from a source to an accelerator structure. SLAC has been investigating various methods of 'pulse compressing' a relatively wide rf pulse ({ge} 1 {mu}s) from a klystron into a narrower, but more intense, pulse. Currently a SLED-II pulse compression scheme is being used at SLAC in the NLC Test Accelerator (NLCTA) and in the Accelerator Structures Test Area (ASTA) to provide high rf power for accelerator and component testing. In ASTA, a 1.05 {mu}s pulse from a 50 MW klystron was successfully pulse compressed to 205 MW with a pulse width of 150 ns. Since operation in NLC will require generating and transporting rf power in excess of 400 MW it was decided to test the breakdown limits of the SLED-II rf components in ASTA with rf power up to the maximum available of 400 MW. This required the combining of power from two 50 MW klystrons and feeding the summed power into the SLED-II pulse compressor. Results from this experiment demonstrated that two of the key components of SLED-II; the Magic Tee and the 'Flower Petal' mode converter (converts between TE{sub 10} rectangular and TE{sub 01} circular modes), were not robust enough at higher power levels. Because of this, a major effort is underway to upgrade the existing devices to operate stably at the higher power levels, and also to investigate new components, which have inherently low field enhancement in their design and therefore more robust.

43 PARTICLE ACCELERATORS↗

Quasi-static to Dynamic Mechanical Response and Microstructure Development of Tantalum-Tungsten Alloys

Lawrence Livermore National Laboratory (LLNL) is interested the quasi-static to dynamic mechanical response and microstructure evolution of tantalum-tungsten (Ta-W) alloys (Ta-2.5W, Ta-5W, and Ta-10W, wt.%) made by conventional wrought processing and additive manufacturing (AM). This work scope was performed at the Colorado School of Mines (Mines) and included quasi-static (e.g., 10 -3 s -1 ) mechanical testing in tension and compression, along with selected high strain rate (Kolsky) pressure bar testing in compression (e.g., 10 3 s -1 ), with and without temperature variations in some instances. Complementary microstructure characterization was performed on undeformed and deformed samples to understand the role of processing on microstructural evolution and the deformation mechanisms that impact the mechanical response with variations in strain rate, temperature, and strain state (e.g., tension versus compression in selected examples). The wrought material provided by LLNL from Viridis Materials was found to have unrecrystallized regions within the microstructure, which led to unexpected results relative to previously reported properties for Ta-W. The AM Ta-2.5W (wt.%) material provided by LLNL was found to have higher compressive strength than wrought Ta-2.5W (wt.%), which is hypothesized to be due to differences in the crystallographic texture between the two materials. This project partially supported several postdocs and graduate students at Mines.

36 MATERIALS SCIENCE↗

New Insights on the Mechanical Characterization of Kerogen-Rich Shale, KRS

In the past decade, mechanical, physical, and chemical characterization of reservoir shale rocks, such as the Woodford shale, which is kerogen-rich shale (KRS), has moved toward micro- and nanoscale testing and analyses. Nanoindentation equipment is now widely used in many industrial and university laboratories to measure shale anisotropic Young’s moduli, kerogen stiffness, plastic yield parameters, and other isotropic and anisotropic poromechanical and viscoelastic properties. However, to date, failure analyses of KRS and the effects of organic components on the tensile strength have not been observed or measured at the micro- or nanoscales. In this study, preserved kerogen-rich Woodford shale samples manufactured in micro-beam and micro-pillar geometries were mechanically tested and brought to failure in tension and compression, respectively. These tests were conducted in situ using a nanoindenter inside a scanning electron microscope (SEM). The load versus displacement curves of prismatic micro-cantilever beams were analyzed in light of high-resolution images collected during tensile fracture initiation, propagation, and ultimately sample failure. The micro-pillar geometries were subjected to a uniaxial compressive load and were also brought to failure while capturing measurements of stress and strain. It was found that, within just a few hundred microns of the KRS microcantilever beams, both brittle and ductile failure modes were observed. In the ductile plastic domain, strain-softening and strain-hardening behaviors were identified and characterized. These were not due to confining stress variations, but due to the volume of the organic matter and the way it is interlaced with the shale minerals in and around the failure planes. The tensile strength characteristics and the large modulus of toughness of kerogen, which is a cross-linked polymer, definitely weigh heavily in our engineering field applications, such as hydraulic fracking, which is a Mode I tensile fracture opening and propagation phenomenon. This practice demands that, due to the complex composite nature of KRS, mechanical characterization be not only for unconfined compressive strength but also for unconfined tensile strength and moduli of ruptures. At the end of this study, the need for nanometer scale mechanical characterization of KRS will become apparent. These nano- and micro-scale shale failure tests reinforce our previous understanding of the heterogeneous composite nature of Woodford KRS and its complex behavior, as well as other source shale reservoir formations.

58 GEOSCIENCES↗

The granular and polymer composite nature of kerogen-rich shale

In the past decade, mechanical, physical, and chemical characterization of reservoir shale rocks, such as the Woodford shale, which is kerogen-rich shale (KRS), has moved toward micro- and nanoscale testing and analyses. Nanoindentation equipment is now widely used in many industrial and university laboratories to measure shale anisotropic Young’s moduli, kerogen stiffness, plastic yield parameters, and other isotropic and anisotropic poromechanical and viscoelastic properties. However, to date, failure analyses of KRS and the effects of organic components on the tensile strength have not been observed or measured at the micro- or nanoscales. In this study, preserved kerogen-rich Woodford shale samples manufactured in micro-beam and micro-pillar geometries were mechanically tested and brought to failure in tension and compression, respectively. These tests were conducted in situ using a nanoindenter inside a scanning electron microscope (SEM). The load versus displacement curves of prismatic micro-cantilever beams were analyzed in light of high-resolution images collected during tensile fracture initiation, propagation, and ultimately sample failure. The micro-pillar geometries were subjected to a uniaxial compressive load and were also brought to failure while capturing measurements of stress and strain. It was found that, within just a few hundred microns of the KRS microcantilever beams, both brittle and ductile failure modes were observed. In the ductile plastic domain, strain-softening and strain-hardening behaviors were identified and characterized. These were not due to confining stress variations, but due to the volume of the organic matter and the way it is interlaced with the shale minerals in and around the failure planes. The tensile strength characteristics and the large modulus of toughness of kerogen, which is a cross-linked polymer, definitely weigh heavily in our engineering field applications, such as hydraulic fracking, which is a Mode I tensile fracture opening and propagation phenomenon. This practice demands that, due to the complex composite nature of KRS, mechanical characterization be not only for unconfined compressive strength but also for unconfined tensile strength and moduli of ruptures. At the end of this study, the need for nanometer scale mechanical characterization of KRS will become apparent. Furthermore, these nano- and micro-scale shale failure tests reinforce our previous understanding of the heterogeneous composite nature of Woodford KRS and its complex behavior, as well as other source shale reservoir formations.

58 GEOSCIENCES↗

True triaxial testing of Castlegate sandstone.

Deformation bands in high porosity sandstone are an important geological feature for geologists and petroleum engineers; however, their formation is not fully understood. Axisymmetric compression, the common test for this material, is not sufficient to fully evaluate localization criteria. This study seeks to investigate the influence of the second principal stress on the failure and the formation of deformation bands in Castlegate sandstone. Experimental results from tests run in the axisymmetric compression stress state, as well as a stress state between axisymmetric compression and pure shear will be presented. Samples are tested using a custom triaxial testing rig at Sandia National Laboratories capable of applying stresses up to 400 MPa. Acoustic emissions are used to locate deformation bands should they not be visible on the specimen exterior. It is suspected that the second invariant of stress has a strong contribution to the failure mode and band formation. These results could have significant bearing on petroleum extraction as well as carbon dioxide sequestration.

02 PETROLEUM↗

Final Report on the Plasma Liner Compression Experiment

The Field Reversed Configuration (FRC) plasmoid’s stability, robustness, and self-organization have been demonstrated in many experiments employing a variety of formation methods over the last 50 years. A new formation method capable of remotely forming a hot, stable, and stationary FRC that can be further compressed to fusion conditions has been developed at MSNW. The formation method consists of the super-sonic merging of two FRCs, which are independently formed outside of the central compression chamber. Upon collision in the center of the compression chamber, the FRCs merge and become stationary, thereby thermalizing their translational kinetic energy. In the Plasma Liner Compression (PLC) experiment, the target FRC is positioned in a compression chamber where it is either magnetically compressed by the increasing flux from a theta-pinch coil, or by the theta-pinch implosion of a pre-formed plasma liner. The plasma liner is formed via an annular array of 32 axially directed MPD plasma sources near the vacuum chamber walls in the compression area. Xenon gas is ionized by the plasma sources, magnetized to the ~ 0.1 T bias field which keeps the Xenon liner confined to an annulus near the chamber wall. The FRC is ideally vacuum isolated from the Xenon plasma liner due to the bias field, which also acts as the guide field required for FRC merging. Close agreement is found between experimental results and 2D MHD numerical calculations. Efficient coupling (~ 50%) between the compression bank and the plasma liner has been observed. Flux and plasma liner compression of merged FRCs were tested. While the flux compression of the merged FRC resulted in a hot fusion plasma, the liner interaction with the FRC at this scale cooled the plasma.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Effect of Moisture and Feedstock Variability on the Rheological Behavior of Corn Stover Particles

Continuous feeding, processing, and handling of biomass powders is pivotal to the economic viability of integrated biorefineries. However, current challenges associated with the operational reliability of bulk solids handling and transport greatly impact the process economics and ultimately the widespread commercialization of integrated biorefineries. In this work, we examine the effect of moisture and feedstock variability on the flow behavior of corn stover biomass particles. The total flow energy, compressibility, shear properties, and wall friction angles were measured for corn stover samples A and B containing 0%, 15%, 25%, 50%, and 75% (mass fraction) moisture contents using a FT4 powder rheometer. In general, the flowability of both A and B was reduced when moisture was present as indicated by the stability and variable flow rate, compressibility, and shear tests. The 15% moisture sample had the highest flow energy, revealing the interplay between the increased surface tension and looser packing both of which were caused by liquid bridging. The 75% moisture sample had the highest compressibility and the lowest flowability factor (ff c ). The trend in wall friction angle was found to be dependent upon the surface hydrophobicity of the wall material. The wall friction angle on the hydrophilic, stainless-steel surface increased with moisture and therefore poses additional handling challenges. On the other hand, the wall friction angle on the hydrophobic polymer surfaces were the lowest for samples with intermediate moisture contents. Sample B had greater bulk density, smaller compressibility, and greater flowability than the sample A , as suggested by the compressibility and shear tests. The wall friction angle of sample B was higher than or equal to that of sample A depending on both the type and the surface roughness of the wall material.

09 BIOMASS FUELS↗