Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “CESIUM ION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 541 records · Page 30

Measurement of Electron Density near Plasma Grid of Large-scaled Negative Ion Source by Means of Millimeter-Wave Interferometer

A millimeter-wave interferometer with the frequency of 39 GHz ({lambda} 7.7 mm) was newly installed to a large-scaled negative ion source. The measurable line-integrated electron density (n{sub e}l) is from 2x10{sup 16} to 7x10{sup 18} m{sup -2}, where n{sub e} and l represent an electron density and the plasma length along the millimeter-wave path, respectively. Our interest in this study is behavior of negative ions and reduction of electron density in the beam extraction region near the plasma grid. The first results show the possibility of the electron density measurement by the millimeter-wave interferometer in this region. The line-averaged electron density increases proportional to the arc power under the condition without cesium seeding. The significant decrease of the electron density and significant increase of the negative ion density were observed just after the cesium seeding. The electron density measured with the interferometer agrees well with that observed with a Langmuir probe. The very high negative ion ratio of n{sub H-}/(n{sub e}+n{sub H-}) = 0.85 was achieved within 400 min. after the cesium seeding.

43 PARTICLE ACCELERATORS↗

Iodine (I) Expulsion at Photoirradiated Mixed Halide Perovskite Interface. Should I Stay or Should I Go?

Visible light irradiation of the mixed halide perovskite film in contact with a solvent (dichloromethane, DCM) in which the film otherwise is stable, leads to selective expulsion of iodide (I) from the film with concurrent shift in the band edge to lower wavelengths. Here we have now employed mixed halide perovskites to uncover the influence of A-site cation (Methyl ammonium, MA and Cesium, Cs) on the mobility of iodide ions under photoirradiation. In the absence of solvent contact, the mixed halide perovskite films undergo photoinduced segregation with a rate constant that decreases with increasing Cs content. Interestingly, the iodide expulsion rate in DCM is strongly dependent on the rate of photoinduced segregation. At Cs atomic concentrations higher than 50%, the films become stable as the iodide expulsion is largely suppressed. The role of A-site cation in dictating the mobility of halide ions is discussed.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Efficient Mn 2+ Doping in Non-Stoichiometric Cesium Lead Bromide Perovskite Quantum Dots

Doping magnetic transition metal ions (e.g., Mn 2+ ) into colloidal quantum dots endows novel optical and magnetic properties to the host materials. CsPbBr 3 quantum dots (QDs) are emerging light-emitting materials with high structural and chemical flexibility in the visible spectral regime. However, efficiently doping Mn 2+ ions in CsPbBr 3 QDs remains challenging, especially when size confinement and ensemble uniformity are needed for understanding the underexplored exciton-dopant exchange interaction. Here, we introduce a doping mechanism based on electrostatic surface Mn 2+ adsorption that enables efficient Mn 2+ incorporation in strongly confined CsPbBr 3 QDs. The resultant QDs are found to have a Cs-deficient stoichiometry compared to their undoped counterparts. A redox reaction-based purification method was developed to remove Mn 2+ cations that are tightly adsorbed on the surface to determine the concentration of lattice-incorporated Mn 2+ . Our synthesis enables a Mn 2+ doping/alloying concentration of up to ∼44% with a Mn 2+ photoluminescence efficiency exceeding 90%. This allows for the determination of the intrinsic exciton-to-dopant energy transfer rate.

Hidayatova, Lamia [Univ. of Oklahoma, Norman, OK (↗

Current-Regulated Arc Modulator Optimization

n this study, the performance of a current-regulated arc modulator was investigated with a focus on its role in initiating and sustaining plasma discharge within the Magnetron Body of the LINAC system. The analysis centered on how switching components, circuit topology, and feedback loop architecture influence critical factors such as energy efficiency, discharge stability, and long-term plasma containment. Particular attention was given to variations in pulse termination behavior, as observed through oscilloscope traces, which revealed inconsistencies affecting the duty factor and cathode temperature. These fluctuations have downstream effects on the cesium-coated cathode surface, thereby impacting H⁻ ion production and beam reliability. Simulation-based testing in LTspice was used to evaluate noise suppression techniques and arc current regulation schemes, revealing how optimized snubber networks, improved pulse shaping, and feedback stability can mitigate modulator-induced noise. The results ide

Campos, Nathan↗

Time and frequency technology at NIST

The state of development of advanced timing systems at NIST is described. The work on cesium and rubidium frequency standards, stored-ion frequency standards, diode lasers used to pump such standards, time transfer, and methods for characterizing clocks, oscillators, and time distribution systems is presented. The emphasis is on NIST-developed technology rather than the general state of the art in this field.

Sullivan, D. B.↗

Development and Testing of a new Current-Regulated Arc Modulator for the LINAC

In this study, the performance of a current-regulated arc modulator was investigated with a focus on its role in initiating and sustaining plasma discharge within the Magnetron Body of the LINAC system. The analysis centered on how switching components, circuit topology, and feedback loop architecture influence critical factors such as energy efficiency, discharge stability, and long-term plasma containment. Particular attention was given to variations in pulse termination behavior, as observed through oscilloscope traces, which revealed inconsistencies affecting the duty factor and cathode temperature. These fluctuations have downstream effects on the cesium-coated cathode surface, thereby impacting H⁻ ion production and beam reliability. Simulation-based testing in LTspice was used to evaluate noise suppression techniques and arc current regulation schemes, revealing how optimized snubber networks, improved pulse shaping, and feedback stability can mitigate modulator-induced noise. The results identified hardware level parameters that significantly enhance discharge repeatability and improve overall plasma performance under operational conditions.

Campos, Nathan [Unlisted, US; Fermilab]↗

Cs atoms on helium nanodroplets and the immersion of Cs{sup +} into the nanodroplet

We report the non-desorption of cesium (Cs) atoms on the surface of helium nanodroplets (He{sub N}) in their 6{sup 2}P{sub 1/2} ({sup 2}{Pi}{sub 1/2}) state upon photo-excitation as well as the immersion of Cs{sup +} into the He{sub N} upon photo-ionization via the 6{sup 2}P{sub 1/2} ({sup 2}{Pi}{sub 1/2}) state. Cesium atoms on the surface of helium nanodroplets are excited with a laser to the 6{sup 2}P states. We compare laser-induced fluorescence (LIF) spectra with a desorption-sensitive method (Langmuir-Taylor detection) for different excitation energies. Dispersed fluorescence spectra show a broadening of the emission spectrum only when Cs-He{sub N} is excited with photon energies close to the atomic D{sub 1}-line, which implies an attractive character of the excited state system (Cs*-He{sub N}) potential energy curve. The experimental data are compared with a calculation of the potential energy curves of the Cs atom as a function of its distance R from the center of the He{sub N} in a pseudo-diatomic model. Calculated Franck-Condon factors for emission from the 6{sup 2}P{sub 1/2} ({sup 2}{Pi}{sub 1/2}) to the 6{sup 2}S{sub 1/2} ({sup 2}{Sigma}{sub 1/2}) state help to explain the experimental data. The stability of the Cs*-He{sub N} system allows to form Cs{sup +} snowballs in the He{sub N}, where we use the non-desorbing 6{sup 2}P{sub 1/2} ({sup 2}{Pi}{sub 1/2}) state as a springboard for ionization in a two-step ionization scheme. Subsequent immersion of positively charged Cs ions is observed in time-of-flight mass spectra, where masses up to several thousand amu were monitored. Only ionization via the 6{sup 2}P{sub 1/2} ({sup 2}{Pi}{sub 1/2}) state gives rise to a very high yield of immersed Cs{sup +} in contrast to an ionization scheme via the 6{sup 2}P{sub 3/2} ({sup 2}{Pi}{sub 3/2}) state. When resonant two-photon ionization is applied to cesium dimers on He droplets, Cs{sub 2}{sup +}-He{sub N} aggregates are observed in time-of-flight mass spectra.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

TRIPLICATE SODIUM IODIDE GAMMA RAY MONITORS FOR THE SMALL COLUMN ION EXCHANGE PROGRAM

This technical report contains recommendations from the Analytical Development (AD) organization of the Savannah River National Laboratory (SRNL) for a system of triplicate Sodium Iodide (NaI) detectors to be used to monitor Cesium-137 ({sup 137}Cs) content of the Decontaminated Salt Solution (DSS) output of the Small Column Ion Exchange (SCIX) process. These detectors need to be gain stabilized with respect to temperature shifts since they will be installed on top of Tank 41 at the Savannah River Site (SRS). This will be accomplished using NaI crystals doped with the alpha-emitting isotope, Americium-241({sup 241}Am). Two energy regions of the detector output will be monitored using single-channel analyzers (SCAs), the {sup 137}Cs full-energy {gamma}-ray peak and the {sup 241}Am alpha peak. The count rate in the gamma peak region will be proportional to the {sup 137}Cs content in the DSS output. The constant rate of alpha decay in the NaI crystal will be monitored and used as feedback to adjust the high voltage supply to the detector in response to temperature variation. An analysis of theoretical {sup 137}Cs breakthrough curves was used to estimate the gamma activity expected in the DSS output during a single iteration of the process. Count rates arising from the DSS and background sources were predicted using Microshield modeling software. The current plan for shielding the detectors within an enclosure with four-inch thick steel walls should allow the detectors to operate with the sensitivity required to perform these measurements. Calibration, testing, and maintenance requirements for the detector system are outlined as well. The purpose of SCIX is to remove and concentrate high-level radioisotopes from SRS salt waste resulting in two waste streams. The concentrated high-level waste containing {sup 137}Cs will be sent to the Defense Waste Processing Facility (DWPF) for vitrification and the low-level DSS will be sent to the Saltstone Production Facility (SPF) to be incorporated into grout.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Lifetime of the Highly Efficient H- Ion Sources

Factors limiting the operating lifetime of Compact Surface Plasma Sources (CSPS) are analyzed and possible treatments for lifetime enhancement are considered. Noiseless discharges with lower gas and cesium densities are produced in experiments with modified discharge cells. With these discharge cells it is possible to increase the emission aperture and extract the same beam with a lower discharge current and with correspondingly increased source lifetime. A design of an advanced CSPS is presented. Optimization of the discharge cells in a Penning H{sup -} ion source is a viable method for increasing the phase space of the stable region for noiseless discharge production. With this method, cesium usage would be decreased, potentially resulting in longer source lifetimes.

43 PARTICLE ACCELERATORS↗

Performance Test on Polymer Waste Form - 12137

Polymer solidification was attempted to produce stable waste form for the boric acid concentrates and the dewatered spent resins. The polymer mixture was directly injected into the mold or drum which was packed with the boric acid concentrates and the dewatered spent resins, respectively. The waste form was produced by entirely curing the polymer mixture. A series of performance tests was conducted including compressive strength test, water immersion test, leach test, thermal stability test, irradiation stability test and biodegradation stability test for the polymer waste forms. From the results of the performance tests for the polymer waste forms, it is believed that the polymer waste form is very stable and can satisfy the acceptance criteria for permanent disposal. At present, performance tests with full scale polymer waste forms are being carried out in order to obtain qualification certificate by the regulatory institute in Korea. Polymer waste forms were prepared with the surrogate of boric acid concentrates and the surrogate of spent ion exchange resins respectively. Waste forms were also made in lab scale and in full scale. Lab. scale waste forms were directly subjected to a series of the performance tests. In the case of full scale waste form, the test specimens for the performance test were taken from a part of waste form by coring. A series of performance tests was conducted including compressive strength test, thermal stability test, irradiation stability test and biodegradation stability test, water immersion test, leach test, and free standing water for the polymer waste forms. In addition, a fire resistance test was performed on the waste forms by the requirement of the regulatory institute in Korea. Every polymer waste forms containing the boric acid concentrates and the spent ion exchange resins had exhibited excellent structural integrity of more than 27.58 MPa (4,000 psi) of compressive strength. On thermal stability testing, biodegradation testing and water immersion testing, no degradation was observed in the waste forms. Also, by measuring the compressive strength after these tests, it was confirmed that the structural integrity was still retained. A leach test was performed by using non radioactive cobalt, cesium and strontium. The leaching of cobalt, cesium and strontium from the polymer waste forms was very low. Also, the polymer waste forms were found to possess adequate fire resistance. From the results of the performance tests, it is believed that the polymer waste form is very stable and can satisfy the acceptance criteria for permanent disposal. At present, Performance tests with full scale polymer waste forms are on-going in order to obtain qualification certificate by the regulatory institute in Korea. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Negative Hydrogen Ion Source with Inverse Gas Magnetron Geometry

The work is dedicated to the experimental investigation of the intense volume-plasma H{sup -} ion source. Formation of ions occurs in a volume of hydrogen plasma (without additives of cesium) due to two-step dissociative attachment of thermal electrons to vibrationally excited molecules H{sub 2}. Preliminary experimental researches of two parameters of the upgraded source--emission density of H{sup -} ions and gas flow are represented below. The advancing of electrode system of the emission chamber of a source has allowed receiving the value of an emission density of H{sup -} ions equal 440 mA/cm{sup 2}.

43 PARTICLE ACCELERATORS↗

Status of the heavy ion beam probe system in the Large Helical Device

A heavy ion beam probe (HIBP) system has been installed into the Large Helical Device (LHD) to measure the spatial profile of the plasma potential and density fluctuations. The optimization of the HIBP system, especially the beam injector, is described. The negative ion beam is required for the MeV beam production in a tandem accelerator. A sputter-type heavy negative ion source has been developed as an intense Au{sup -} beam source to produce Au{sup +} beams with energy in the MeV range. The extraction electrodes and the Einzel lens system of the ion source have been designed taking into account the beam optics, and installed into the real machine. Throughout the plasma diagnostics on LHD experiments, the consumptions of vaporized caesium and gold target are being characterized for practical operations. In addition, the experimental charge fractions are compared with the theoretical fractions for understanding the charge-changing behavior of Au{sup -} ions and optimizing the fraction of Au{sup +} ions at the exit of the tandem accelerator of the HIBP system.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Emittance measurements for optimum operation of the J-PARC RF-driven H{sup −} ion source

In order to satisfy the Japan Proton Accelerator Research Complex (J-PARC) second stage requirements of an H{sup −} ion beam of 60mA within normalized emittances of 1.5πmm•mrad both horizontally and vertically, a flat top beam duty factor of 1.25% (500μs×25Hz) and a life-time of longer than 1month, the J-PARC cesiated RF-driven H{sup −} ion source was developed by using an internal-antenna developed at the Spallation Neutron Source (SNS). The transverse emittances of the source were measured with various conditions to find out the optimum operation conditions minimizing the horizontal and vertical rms normalized emittances. The transverse emittances were most effectively reduced by operating the source with the plasma electrode temperature lower than 70°C. The optimum value of the cesium (Cs) density around the beam hole of the plasma electrode seems to be proportional to the plasma electrode temperature. The fine control of the Cs density is indispensable, since the emittances seem to increase proportionally to the excessiveness of the Cs density. Furthermore, the source should be operated with the Cs density beyond a threshold value, since the plasma meniscus shape and the ellipse parameters of the transverse emittances seem to be changed step-function-likely on the threshold Cs value.

43 PARTICLE ACCELERATORS↗

Wash Penalty Factors: Insight into the Effects of Water Wash Down of Building Materials for Radionuclide/Nuclear (Rn) Decontamination - 20153

The release of radiological material to the urban environment can have a devastating socio-economic impact. In an urban release scenario, areas around the dispersal epicenter and any areas contaminated via atmospheric deposition may require extensive decontamination. Most recently, our group reported the decontamination efficacy of pressurized water washing of common porous building materials, and compared the penetration depth of the contaminations before and after exposure to pressurized tap water. Here, we continue evaluation of the decontamination efficacy of wash solutions based on potassium (K{sup +}) salt for cesium (Cs), strontium (Sr), and europium (Eu) contaminations on common building surfaces. The surfaces included: the cement used in concrete, the aggregate used in concrete, intact concrete, roadway asphalt, asphalt shingles, and latex paint. We deposited solutions of {sup 137}Cs, {sup 85}Sr, and {sup 152}Eu onto numerous common building materials and exposed these materials to a static bath or low-pressure flow of tap water, 0.1 M potassium chloride (KCl), and 0.5 M KCl. The decontamination efficacy and the depth profile for residual contamination were measured to determine the conditions under which applying a wash solution has benefit compared to physically removing the surface material. To aid in these analyses, we introduced a 'wash penalty factor' to quantify the degree to which contamination migrated into the bulk material by the action of the wash method. On asphalt, 70-80% of the radionuclides were found to be within 0.02 mm of the surface. Cs{sup +} bonded to negative charge sites on the surface of the mineral aggregate (used in concrete) so decontamination was improved by ion exchange with K{sup +}. Sr{sup 2+} is soluble and removed by water, while not bonding to aggregate or demonstrating solubility in the liquid asphalt. Eu{sup 3+} is precipitated and not removed in gentle wash but displays mobility within the pore space that suggests its presence as a colloid. Concrete is more porous than asphalt, and 80% of the radionuclides were within 0.2 mm of the surface for {sup 137}Cs and {sup 152}Eu and 50- 80% for {sup 85}Sr. On concrete, Cs{sup +} bonds similarly to asphalt. Sr{sup 2+} bonds to the cement or precipitates from the alkaline pore water. Eu{sup 3+} sorbs to the cement and then precipitates. In brick, the results for Cs{sup +} and Sr{sup 2+} suggested that diffusion of ions from deeper in the coupon was important. Eu{sup 3+} is removed poorly due to precipitation. We will explain and report example wash penalty factors that vary from 0 to > 1 for the various methods and the implications for deciding when to implement wash down methods. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Ramping Up the SNS Beam Power with the LBNL Baseline H- source

LBNL designed and built the Frontend for the Spallation Neutron Source, including its H- source and Low-Energy Beam Transport (LEBT). This paper discusses the performance of the H- source and LEBT during the commissioning of the accelerator, as well as their performance while ramping up the SNS beam power to 540 kW. Detailed discussions of major shortcomings and their mitigations are presented to illustrate the effort needed to take even a well-designed R&D ion source into operation. With these modifications, at 4% duty factor the LBNL H- source meets the essential requirements that were set at the beginning of the project.

43 PARTICLE ACCELERATORS↗

Crystal Growth of Cesium Hafnium Chloride (Cs2HfCl6) Scintillating Crystal

Crystal growth is the process where crystalline substance forms and increases in size through the addition of atoms, ions, or molecules. In this research we used the Bridgman technique to grow Cesium Hafnium Chloride (C2HfCl6). This technique is ideal for growing large volume crystal. Using a vertical furnace with two heating zones for heating and cooling. the material solidifies into a crystal as it slowly transitions from hot to cold zone.

Tribble, Jalen↗

Direct Encapsulation of Spent Ion-exchange Resins at the Dukovany Nuclear Power Plant, Czech Republic - 12367

At the Dukovany Nuclear Power Plant there are large amounts of spent ion exchange resins contained within storage tanks. These resins are a product of the operation of an Active Water Purification System within the Power Plant. Activity levels of the resins are in the range of 105 to 10{sup 6} Bq/l and the main isotopes present are Co-60, Cs-137, Mn-54 and Ag-110m. In order to maintain storage tank availability throughout the planned lifetime of the Power Plant these resins must be removed and disposed of safely. The storage tanks do not have an effective retrieval route for the resins and the installed agitation system is inoperable. A proven system for retrieving and directly encapsulating these resins to a standard required for the Czech repository is described, together with an overview of operational performance. Experience gained from this and other projects has highlighted some common challenges relating to the treatment of ion-exchange resins and sludges. There are common approaches that can assist in overcoming these challenges. 1. Transport resin / sludge type waste over as short a distance as possible to avoid issues with line plugging. 2. Transport these wastes once and once only wherever possible. 3. Try to keep the treatment process as simple as possible. With sludge or resin handling equipment consider the physical properties foremost - radiological issues can be addressed within any subsequent design. 4. Consider the use of dry-mix technologies. This avoids the requirement for expensive and complicated grouting plant. 5. Avoid the use of make up water for transport purposes if at all possible - it introduces secondary waste that needs to be treated at additional cost. 6. Consider alternative disposal techniques. SIAL{sup R} is AMEC's preferred technology as we developed it and understand it well - additionally the waste loading factors are much higher than for cement. 7. Consider final waste volumes when selecting the disposal technique. Disposal costs will probably make up the bulk of the total life-time cost for any retrieval / encapsulation project. 8. Have a selection of ion-exchange resin/sludge retrieval techniques available - it is difficult and time consuming to develop a technique that will cope with all eventualities, particularly when there are unknown conditions. It is much more productive to switch retrieval techniques as appropriate to deal with evolving conditions. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗