Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “CAVITY”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 541 records · Page 30

Characterization of faulted dislocation loops and cavities in ion irradiated alloy 800H

Alloy 800H is a high nickel austenitic stainless steel with good high temperature mechanical properties which is considered for use in current and advanced nuclear reactor designs. The irradiation response of 800H was examined by characterizing samples that had been bulk ion irradiated at the Michigan Ion Beam Laboratory with 5 MeV Fe 2+ ions to 1, 10, and 20 dpa at 440 °C. Transmission electron microscopy was used to measure the size and density of both {111} faulted dislocation loops and cavities as functions of depth from the irradiated surface. The faulted loop density increased with dose from 1 dpa up to 10 dpa where it saturated and remained approximately the same until 20 dpa. The faulted loop average diameter decreased between 1 dpa and 10 dpa and again remained approximately constant from 10 dpa to 20 dpa. Cavities were observed after irradiation doses of 10 and 20 dpa, but not after 1 dpa. The average diameter of cavities increased with dose from 10 to 20 dpa, with a corresponding small decrease in density. Cavity denuded zones were observed near the irradiated surface and near the ion implantation peak. To further understand the microstructural evolution of this alloy, FIB lift-out samples from material irradiated in bulk to 1 and 10 dpa were re-irradiated in-situ in their thin-foil geometry with 1 MeV Kr 2+ ions at 440 °C at the Intermediate Voltage Electron Microscope. We observed that the cavities formed during bulk irradiation shrank under thin-foil irradiation in-situ while dislocation loops were observed to grow and incorporate into the dislocation network. The thin-foil geometry used for in-situ irradiation is believed to cause the cavities to shrink.

36 MATERIALS SCIENCE↗

Behavior of helium cavities in ion-irradiated W-Ni-Fe ductile-phase toughened tungsten

This study reports on the distribution of helium (He) cavities in a hot-rolled W-Ni-Fe ductile-phase toughened tungsten (DPT W) composite irradiated to a dose and a helium concentration that are comparable to those in the material after 5-year irradiation in a conceptual fusion power plant. Here, the DPT W sample consists of W particles embedded in a ductile-phase NiFeW matrix with a nominal composition of 90W-7Ni-3Fe by weight. It was hot-rolled to a thickness reduction by 87% (87R DPT W). Sequential irradiation of the material with 1.2 MeV Ni + ions to a fluence of 2.15×10 16 Ni + /cm 2 and 90 keV He + ions to 6.5×10 15 He + /cm 2 was performed at 973 K. Larger He cavities with a lower number density are observed in NiFeW than W. Helium cavities are aggregated preferentially along the NiFeW/W interphase boundary. This behavior is not observed along the W/W grain boundary under the same irradiation conditions. A similar distribution of He cavities with comparable sizes is observed in 87R DPT W irradiated with He + ions only, suggesting that the He cavity distribution is not significantly affected by pre-irradiation of Ni + ions at 973 K. The data from this study does not provide any evidence for formation of visible voids or Ni precipitates in W phase irradiated with Ni + ions only. Diffusion and clustering of He atoms and mobile vacancies during ion irradiation at 973 K are responsible for the formation and growth of the He cavities.

36 MATERIALS SCIENCE↗

Effect of beam arrangement on oral cavity dose in external beam radiotherapy of nasopharyngeal carcinoma

This study compared the oral cavity dose between the routine 7-beam intensity-modulated radiotherapy (IMRT) beam arrangement and 2 other 7-beam IMRT with the conventional radiotherapy beam arrangements in the treatment of nasopharyngeal carcinoma (NPC). Ten NPC patients treated by the 7-beam routine IMRT technique (IMRT-7R) between April 2009 and June 2009 were recruited. Using the same computed tomography data, target information, and dose constraints for all the contoured structures, 2 IMRT plans with alternative beam arrangements (IMRT-7M and IMRT-7P) by avoiding the anterior facial beam and 1 conventional radiotherapy plan (CONRT) were computed using the Pinnacle treatment planning system. Dose-volume histograms were generated for the planning target volumes (PTVs) and oral cavity from which the dose parameters and the conformity index of the PTV were recorded for dosimetric comparisons among the plans with different beam arrangements. The dose distributions to the PTVs were similar among the 3 IMRT beam arrangements, whereas the differences were significant between IMRT-7R and CONRT plans. For the oral cavity dose, the 3 IMRT beam arrangements did not show significant difference. Compared with IMRT-7R, CONRT plan showed a significantly lower mean dose, V30 and V-40, whereas the V-60 was significantly higher. The 2 suggested alternative beam arrangements did not significantly reduce the oral cavity dose. The impact of varying the beam angles in IMRT of NPC did not give noticeable effect on the target and oral cavity. Compared with IMRT, the 2-D conventional radiotherapy irradiated a greater high-dose volume in the oral cavity.

61 RADIATION PROTECTION AND DOSIMETRY↗

Effects of break geometry and orientation on helium-air mixing in simulated reactor cavities of high temperature gas reactors

Here, this study experimentally examined the spatial and temporal variations in air and helium concentrations and temperature fields within simulated reactor cavities of a High Temperature Gas Reactor (HTGR) following helium discharge into an initially air-filled reactor cavity system. Detailed temperature maps were generated using a combination of fiber optics temperature sensor and multiple thermocouple probes within the simulated reactor cavities. The research scenario involved a hypothetical small pipe break in the Reactor Pressure Vessel, resulting in the release of high-temperature helium into the surrounding cavity. A scaled multi-compartment experimental facility, modeled after the General Atomics Modular High Temperature Gas Reactor (GA-MHTGR) design, was constructed for helium and air mixing experiments. Oxygen sensors and thermocouple probes were installed in all five cavities to measure the concentrations of oxygen (or helium) and the temperature distributions of the gas mixture. The experimental findings highlighted the significant impact of the injected helium jet velocity on the gas mixing process and demonstrated how the direction of the helium jet influences the air-helium temperature profiles within the cavities.

Air-ingress↗

Hybrid Integration of GaP Photonic Crystal Cavities with Silicon-Vacancy Centers in Diamond by Stamp-Transfer

Optically addressable solid-state defects are emerging as some of the most promising qubit platforms for quantum networks. Maximizing photon-defect interaction by nanophotonic cavity coupling is key to network efficiency. We demonstrate fabrication of gallium phosphide 1-D photonic crystal waveguide cavities on a silicon oxide carrier and subsequent integration with implanted silicon-vacancy (SiV) centers in diamond using a stamp-transfer technique. The stamping process avoids diamond etching and allows fine-tuning of the cavities prior to integration. After transfer to diamond, we measure cavity quality factors (Q) of up to 8900 and perform resonant excitation of single SiV centers coupled to these cavities. For a cavity with a Q of 4100, we observe a 3-fold lifetime reduction on-resonance, corresponding to a maximum potential cooperativity of C = 2. In conclusion, these results indicate promise for high photon-defect interaction in a platform which avoids fabrication of the quantum defect host crystal.

Purcell enhancement↗

Perturbation theory to model shielding effectiveness of cavities loaded with electromagnetic dampeners

It is notable that a slotted resonant cavity with high-quality factor exhibits interior electromagnetic (EM) fields that may be even larger than the external field. The authors aspire to reduce the cavity's EM fields and quality factor over a frequency band analytically, numerically, and experimentally by introducing microwave absorbing materials in the cavity. A perturbation model approach was developed to estimate the quality factor of loaded cavities, which is validated against full-wave simulations and experiments. Conclusions with 78.7 mils (2 mm) thick ECCOSORB-MCS absorber placed on the inside cavity wall above and below the aperture slot (with only 0.026% cavity volume) result in a reduction of shielding effectiveness >19 dB and reductions in quality factor >91%, providing confirmation of the efficacy of this approach.

42 ENGINEERING↗

A method to measure the frequencies of individual half cells in a dumbbell cavity

Dumbbell fabrication is a midprocess for manufacturing an elliptical superconducting rf cavity. In order to understand how a welding shrinkage affects a dumbbell's frequencies and length, we need to measure the exact frequencies of each individual half cell of a dumbbell. To improve such a calculation precision and to simplify the calculation formulae, based on a two-coupled oscillator model and a cavity perturbation theory, a new formula to calculate the individual half-cell frequencies of a dumbbell or the individual cavity frequencies of a two-cavity coupling system has been developed, and its performance has been confirmed by using a dumbbell simulation. This formula can be applied to any kind of rf cavities with electric, magnetic, or electromagnetic coupling, if a coupling hole between two coupling cavities is small compared to the wavelength. Compared to other calculation formulae, this formula simplifies the calculation process of the individual resonator frequencies of a coupling system considerably, and it can also improve the calculation precision than that of a normal calculation method. Another advantage of this new method is that we do not need to consider a coupling factor between two resonators during a testing for an individual resonator frequency of an oscillator. The developed formula has been successfully used to tune the PEFP dumbbells.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Progress on a Be Cavity Design

Previous RF experiments with normal-conducting cavities have demonstrated that there is a significant degradation in maximum gradient when the cavity is subjected to a strong axial magnetic field. We have developed a model suggesting that a cavity with beryllium walls may perform better than copper cavities. In this paper we outline the issues that led us to propose fabricating a Be-wall cavity. We also discuss a concept for fabricating such a cavity and mention some of the manufacturing issues we expect to face.

43 PARTICLE ACCELERATORS↗

Beam current enhancement of microwave plasma ion source utilizing double-port rectangular cavity resonator

Microwave plasma ion source with rectangular cavity resonator has been examined to improve ion beam current by changing wave launcher type from single-port to double-port. The cavity resonators with double-port and single-port wave launchers are designed to get resonance effect at TE-103 mode and TE-102 mode, respectively. In order to confirm that the cavities are acting as resonator, the microwave power for breakdown is measured and compared with the E-field strength estimated from the HFSS (High Frequency Structure Simulator) simulation. Langmuir probe measurements show that double-port cavity enhances central density of plasma ion source by modifying non-uniform plasma density profile of the single-port cavity. Correspondingly, beam current from the plasma ion source utilizing the double-port resonator is measured to be higher than that utilizing single-port resonator. Moreover, the enhancement in plasma density and ion beam current utilizing the double-port resonator is more pronounced as higher microwave power applied to the plasma ion source. Therefore, the rectangular cavity resonator utilizing the double-port is expected to enhance the performance of plasma ion source in terms of ion beam extraction.

43 PARTICLE ACCELERATORS↗

Design parameters and commissioning of vertical inserts used for testing the XFEL superconducting cavities

The European XFEL is a new research facility currently under construction at DESY in the Hamburg area in Germany. From 2015 on, it will generate extremely intense X-ray flashes that will be used by researchers from all over the world. The superconducting XFEL linear accelerator consists of 100 accelerator modules with more than 800 RF-cavities inside. The accelerator modules, superconducting magnets and cavities will be tested in the accelerator module test facility (AMTF). This paper gives an overview of the design parameters and the commissioning of the vertical insert, used in two cryostats (XATC) of the AMTF-hall. The Insert serves as a holder for 4 nine-cell cavities. This gives the possibility to cool down 4 cavities to 2K in parallel and, consequently, to reduce the testing time. The following RF measurement, selected as quality check, will be done separately for each cavity. Afterwards the cavities will be warmed up again and will be sent to the accelerator module assembly.

43 PARTICLE ACCELERATORS↗

Introduction of DC line structures into a superconducting microwave 3D cavity

We report a technique that can noninvasively add multiple DC wires into a 3D superconducting microwave cavity for electronic devices that require DC electrical terminals. We studied the influence of our DC lines on the cavity performance systematically. We found that the quality factor of the cavity is reduced if any of the components of the electrical wires cross the cavity equipotential planes. Using this technique, we were able to incorporate a quantum dot (QD) device into a 3D cavity. We then controlled and measured the QD transport signal using the DC lines. We have also studied the heating effects of the QD by the microwave photons in the cavity.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Design of a multi beam klystron cavity from its single beam parameters

The klystron is a well-known microwave amplifier which uses kinetic energy of an electron beam for amplification of the RF signal. There are some limitations of conventional single beam klystron such as high operating voltage, low efficiency and bulky size at higher power levels, which are very effectively handled in Multi Beam Klystron (MBK) that uses multiple low purveyance electron beams for RF interaction. Each beam propagates along its individual transit path through a resonant cavity structure. Multi-Beam klystron cavity design is a critical task due to asymmetric cavity structure and can be simulated by 3D code only. The present paper shall discuss the design of multi beam RF cavities for klystrons operating at 2856 MHz (S-band) and 5 GHz (C-band) respectively. The design approach uses some scaling laws for finding the electron beam parameters of the multi beam device from their single beam counter parts. The scaled beam parameters are then used for finding the design parameters of the multi beam cavities. Design of the desired multi beam cavity can be optimized through iterative simulations in CST Microwave Studio.

42 ENGINEERING↗

Influence of phonon reservoir on photon blockade in a driven quantum dot-cavity system

We theoretically investigate the influence of the phonon bath on photon blockade in a simultaneously driven dot-cavity system. An optimal condition for avoiding two-photon excitation of a cavity field is put forward which can be achieved by modulating the phase difference and the strengths of the driving fields. The second-order correlation function and the mean photon number of the cavity field are discussed. In the absence of phonon effect, the strong photon blockade in a moderate quantum dot (QD)-cavity coupling regime occurs, which can be attributed to the destructive quantum interference arisen from different transition paths induced by simultaneously driving the dressed QD-cavity system. The participation of acoustic-phonon reservoir produces new transition channels for the QD-cavity system, which leads to the damage of destructive interference. As a result, the photon blockade effect is hindered when taking the electron-phonon interaction into account. It is also found that the temperature of the phonon reservoir is disadvantageous for the generation of photon blockade.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

The effect of cavity tuning on oxygen beam currents of an A-ECR type 14 GHz electron cyclotron resonance ion source

The efficiency of the microwave-plasma coupling plays a significant role in the production of highly charged ion beams with electron cyclotron resonance ion sources (ECRISs). The coupling properties are affected by the mechanical design of the ion source plasma chamber and microwave launching system, as well as damping of the microwave electric field by the plasma. Several experiments attempting to optimize the microwave-plasma coupling characteristics by fine-tuning the frequency of the injected microwaves have been conducted with varying degrees of success. The inherent difficulty in interpretation of the frequency tuning results is that the effects of microwave coupling system and the cavity behavior of the plasma chamber cannot be separated. A preferable approach to study the effect of the cavity properties of the plasma chamber on extracted beam currents is to adjust the cavity dimensions. The results of such cavity tuning experiments conducted with the JYFL 14 GHz ECRIS are reported here. The cavity properties were adjusted by inserting a conducting tuner rod axially into the plasma chamber. The extracted beam currents of oxygen charge states O{sup 3+}–O{sup 7+} were recorded at various tuner positions and frequencies in the range of 14.00–14.15 GHz. It was observed that the tuner position affects the beam currents of high charge state ions up to several tens of percent. In particular, it was found that at some tuner position / frequency combinations the plasma exhibited “mode-hopping” between two operating regimes. The results improve the understanding of the role of plasma chamber cavity properties on ECRIS performances.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Effect of Many Modes on Self-Polarization and Photochemical Suppression in Cavities

The standard description of cavity-modified molecular reactions typically involves a single (resonant) mode, while in reality the quantum cavity supports a range of photon modes. In this work we demonstrate that as more photon modes are accounted for, physico-chemical phenomena can dramatically change, as illustrated by the cavity-induced suppression of the important and ubiquitous process of proton-coupled electron-transfer. Using a multi-trajectory Ehrenfest treatment for the photonmodes, we find that self-polarization effects become essential, and we introduce the concept of selfpolarization- modified Born-Oppenheimer surfaces as a new construct to analyze dynamics. As the number of cavity photon modes increases, the increasing deviation of these surfaces from the cavityfree Born-Oppenheimer surfaces, together with the interplay between photon emission and absorption inside the widening bands of these surfaces, leads to enhanced suppression. The present findings are general and will have implications for the description and control of cavity-driven physical processes of molecules, nanostructures and solids embedded in cavities.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Light–matter interaction of a molecule in a dissipative cavity from first principles

Cavity-mediated light–matter coupling can dramatically alter opto-electronic and physico-chemical properties of a molecule. Ab initio theoretical predictions of these systems need to combine non-perturbative, many-body electronic structure theory-based methods with cavity quantum electrodynamics and theories of open-quantum systems. Here, we generalize quantum-electrodynamical density functional theory to account for dissipative dynamics of the cavity and describe coupled cavity–single molecule interactions in the weak-to-strong-coupling regimes. Specifically, to establish this generalized technique, we study excited-state dynamics and spectral responses of benzene and toluene under weak-to-strong light–matter coupling. By tuning the coupling, we achieve cavity-mediated energy transfer between electronically excited states. This generalized ab initio quantum-electrodynamical density functional theory treatment can be naturally extended to describe cavity-mediated interactions in arbitrary electromagnetic environments, accessing correlated light–matter observables and thereby closing the gap between electronic structure theory, quantum optics, and nanophotonics.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Superconducting radio-frequency cavities made from medium and low-purity niobium ingots

Superconducting radio-frequency cavities made of ingot niobium with residual resistivity ratio (RRR) greater than 250 have proven to have similar or better performance than fine-grain Nb cavities of the same purity, after standard processing. The high purity requirement contributes to the high cost of the material. As superconducting accelerators operating in continuous-wave typically require cavities to operate at moderate accelerating gradients, using lower purity material could be advantageous not only to reduce cost but also to achieve higher Q 0 -values. In this contribution we present the results from cryogenic RF tests of 1.3–1.5 GHz single-cell cavities made of ingot Nb of medium (RRR = 100–150) and low (RRR = 60) purity from different suppliers. Cavities made of medium-purity ingots routinely achieved peak surface magnetic field values greater than 70 mT with an average Q 0 -value of 2 × 10 10 at 2 K after standard processing treatments. As a result, the performances of cavities made of low-purity ingots were affected by significant pitting of the surface after chemical etching.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

First characterisation of the MAGO cavity, a superconducting RF detector for kHz–MHz gravitational waves

Heterodyne detection using microwave cavities is a promising method for detecting high-frequency gravitational waves (GWs) or ultralight axion dark matter. In this work, we report on studies conducted on a spherical 2-cell cavity developed by the MAGO collaboration for high-frequency GWs detection. Although fabricated around 20 years ago, the cavity had not been used since. Due to deviations from the nominal geometry, we conducted a mechanical survey and performed room-temperature plastic tuning. Measurements and simulations of the mechanical resonances and electromagnetic properties were carried out, as these are critical for estimating the cavity’s GW coupling potential. Based on these results, we plan further studies in a cryogenic environment. The cavity characterisation does not only provide valuable experience for a planned physics run but also informs the future development of improved cavity designs.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗