Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “CALIBRATION STANDARDS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 541 records · Page 30

Measured physical and optical properties of the passive geodetic satellite /Pageos/ and Echo 1.

Two satellites used for geodesy, Pageos and Echo 1, have been observed in a continuing program since 1966 to determine the stability of their physical and optical properties. Measurements are made in the UBVRI spectral system. The amount of solar radiation reflected from a satellite's surface is measured photoelectrically and is calibrated against known stellar magnitudes by standard astronomical techniques. The calibrated satellite magnitudes are analyzed with respect to the sun-satellite-observer phase angle to infer the shape and size of the satellite and the reflective properties of the satellite's surface material. The physical and optical properties are used to determine proper position of the solar image on the satellite's surface, resulting in more precise geometric geodesy. Quantitative results from five observing periods indicate that, although local structural anomalies appear to exist, both satellites essentially maintained their nominal average 30.48-meter (50-ft) radius of curvature and specular reflecting characteristics.

Mcdougal, D. S.↗

Spectrometric Estimation of Total Nitrogen Concentration in Douglas-Fir Foliage

Spectral measurements of fresh and dehydrated Douglas-fir foliage, from trees cultivated under three fertilization treatments, were acquired with a laboratory spectrophotometer. The slope (first-derivative) of the fresh- and dry-leaf absorbance spectra at locations near known protein absorption features was strongly correlated with total nitrogen (TN) concentration of the foliage samples. Particularly strong correlation was observed between the first-derivative spectra in the 2150-2170 nm region and TN, reaching a local maximum in the fresh-leaf spectra of -0.84 at 2 160 nm. Stepwise regression was used to generate calibration equations relating first derivative spectra from fresh, dry/intact, and dry/ground samples to TN concentration. Standard errors of calibration were 1.52 mg g-1 (fresh), 1.33 (dry/intact), and 1.20 (dry/ground), with goodness-of-fit 0.94 and greater. Cross-validation was performed with the fresh-leaf dataset to examine the predictive capability of the regression method; standard errors of prediction ranged from 1.47 - 2.37 mg g(exp -1) across seven different validation sets, prediction goodness of fit ranged from .85-.94, and wavelength selection was fairly insensitive to the membership of the calibration set. All regressions in this study tended to select wavelengths in the 2100-2350 nm region, with the primary selection in the 2142-2172 nm region. The study provides positive evidence concerning the feasibility of assessing TN status of fresh-leaf samples by spectrometric means. We assert that the ability to extract biochemical information from fresh-leaf spectra is a necessary but insufficient condition regarding the use of remote sensing for canopy-level biochemical estimation.

Johnson, Lee F.↗

Calibration of Post-AGB Supergiants as Standard Extragalactic Candles for HST

This report summarizes activities carried out with support from the NASA Ultraviolet, Visible, and Gravitational Astrophysics Research and Analysis Program. The aim of the program is to calibrate the absolute magnitudes of post-asymptotic-giant-branch (post-AGB or PAGB) stars, which we believe will be an excellent new "standard candle" for measuring extragalactic distances. The reason for this belief is that in old populations, the stars that are evolving through the PAGB region of the HR (Hertzsprung-Russell) diagram arise from only a single main-sequence turnoff mass. In addition, the theoretical PAGB evolutionary tracks show that they evolve through this region at constant luminosity; hence the PAGB stars should have an extremely narrow luminosity function. Moreover, as the PAGB stars evolve through spectral types F and A (en route from the AGB to hot stellar remnants and white dwarfs), they have the highest luminosities attained by old stars (both bolometrically and in the visual band). Finally, the PAGB stars of these spectral types are very easily identified, due to their large Balmer jumps, which are due to their very low surface gravities.

Bond, Howard E.↗

Accurate frequency and intensity measurements of the infrared spectra of atmospheric molecules

Various problems encountered and solutions found in infrared laboratory measurements on atmospheric molecules are discussed. The advantages and limitations of various measurement techniques and equipment are discussed, with emphasis placed on calibration techniques and measurement accuracy and precision. Frequency calibration aids are presented, including the current and planned tables of absorption frequency standards being developed by the Bureau of Standards for the calibration of high-resolution devices with an accuracy of + or - 3 MHz. It is noted that intensity measurements are highly susceptible to systematic errors and that great care must be taken to obtain accuracies better than + or - 10%. What is even more difficult is knowing the accuracy of a particular measurement. Recent work done on providing accurate intensity data are described.

Maki, A. G.↗

Spectral Irradiance Calibration in the Infrared: 1.2 - 35 microns Spectra of Six Standard Stars - Part 4

We present five new absolutely calibrated continuous stellar spectra from 1.2 to 35 microns, constructed as far as possible from actual observed spectral fragments taken from the ground, the Kuiper Airborne Observatory (KAO), and the IRAS Low Resolution Spectrometer (LRS). These stars- beta Peg, alpha Boo, beta And, beta Gem, and alpha Hya-augment our already created complete absolutely calibrated spectrum for alpha Tau. All these spectra have a common calibration pedigree. The wavelength coverage is ideal for calibration of many existing and proposed ground-based, airborne, and satellite sensors.

Cohen, Martin↗

Contributed Review: Absolute spectral radiance calibration of fiber-optic shock-temperature pyrometers using a coiled-coil irradiance standard lamp

We describe an accurate and precise calibration procedure for multichannel optical pyrometers such as the 6-channel, 3-ns temporal resolution instrument used in the Caltech experimental geophysics laboratory. We begin with a review of calibration sources for shock temperatures in the 3000-30 000 K range. High-power, coiled tungsten halogen standards of spectral irradiance appear to be the only practical alternative to NIST-traceable tungsten ribbon lamps, which are no longer available with large enough calibrated area. However, non-uniform radiance complicates the use of such coiled lamps for reliable and reproducible calibration of pyrometers that employ imaging or relay optics. Careful analysis of documented methods of shock pyrometer calibration to coiled irradiance standard lamps shows that only one technique, not directly applicable in our case, is free of major radiometric errors. We provide a detailed description of the modified Caltech pyrometer instrument and a procedure for its absolute spectral radiance calibration, accurate to ±5%. We employ a designated central area of a 0.7× demagnified image of a coiled-coil tungsten halogen lamp filament, cross-calibrated against a NIST-traceable tungsten ribbon lamp. We give the results of the cross-calibration along with descriptions of the optical arrangement, data acquisition, and processing. We describe a procedure to characterize the difference between the static and dynamic response of amplified photodetectors, allowing time-dependent photodiode correction factors for spectral radiance histories from shock experiments. We validate correct operation of the modified Caltech pyrometer with actual shock temperature experiments on single-crystal NaCl and MgO and obtain very good agreement with the literature data for these substances. We conclude with a summary of the most essential requirements for error-free calibration of a fiber-optic shock-temperature pyrometer using a high-power coiled tungsten halogen irradiance standard lamp.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Water isotope data for the TEMPEST study site, 2023-2026

This dataset contains water isotope (deuterium (dD) and oxygen (d18O)) data from porewater, experimental source water, and aquifer sources from the Terrestrial Ecosystem Manipulation to Probe the Effects of Storm Treatments (TEMPEST) experimental field site in Edgewater, MD. Samples were taken from 2023-2026 and included in file "TEMPEST_Water_Isotope_LANL_2023-2026.csv". Porewater samples were taken from 15cm depth at multiple locations in each experimental plot (i.e., control, freshwater, and saltwater). Water samples were stored in 2 ml amber glass vials with septum caps under refrigeration until analysis. A L2140-i Picarro cavity ringdown spectrometer connected to an A0211 Picarro vaporization module was used to run water samples. Standards (United States Geological Survey (USGS) 47 and 48) were used to check instrument accuracy during each run of samples. Post-processing codes were run to calculate isotopic values from raw data. Reported isotope data is post-processed. Raw data CSV files from the Picarro were processed using a Python script and output as excel files containing data calibrated to Vienna Standard Mean Ocean Water (VSMOW). Standardization is based on USGS47 and USGS48 standards that are measured before and after every 5-10 unknowns. Every measurement is comprised of 10 injections. Processing involved discarding the first 4 injections due to a known memory effect. Raw means of the last 6 injections are taken for each measurement and then corrected from the linear calibration relationship of the USGS standards expected vs measured values to obtain corrected compositions relative to VSMOW. Reported isotope data are corrected mean results.

Aquifer↗

Stress anisotropy and concentration effects in high pressure measurements

Sodium chloride is used as an internal pressure standard in high pressure research. Possible corrections are discussed which are needed in the calibration of this standard due to the independent effects of stress anisotropy and stress concentration in pressure vessels. The first is due to the lack of a truly hydrostatic state of stress in solid state pressure vessels. The second is due to the difference in the compressibilities between the pressure transmitting substances (sodium chloride) and a stiffer test specimen. These two corrections are then combined and a total correction, as a function of measured pressure, is discussed for two systems presently in use. The predicted value of the combined effect is about 5-10% of the pressure at 30 GPa.

Nelson, D. A., Jr.↗

Analytical study of electrophoretic characterization of kidney cells

Embryonic kidney cells were studied as a follow-up to the MA-011 Electrophoresis Technology Experiment which was conducted during the Apollo Soyuz Test Project (ASTP). The postflight analysis of the performance of the ASTP zone electrophoresis experiment involving embryonic kidney cells is reported. The feasibility of producing standard particles for electrophoresis was also studied. This work was undertaken in response to a need for standardization of methods for producing, calibrating, and storing electrophoretic particle standards which could be employed in performance tests of various types of electrophoresis equipment. Promising procedures were tested for their suitability in the production of standard test particles from red blood cells.

Knox, R. J.↗

Comparison between Brewer spectrometer, M 124 filter ozonometer and Dobson spectrophotometer

Concurrent measurements were taken using the Brewer spectrometer no. 30, the filter ozonometer M 124 no. 200 and the Dobson spectrophotometer no. 71 from September 1987 to December 1988 at Potsdam. The performance of the instrument types and the compatibility of ozone data was checked under the conditions of a field measuring station. Total ozone values derived from Dobson AD direct sun measurements were considered as standard. The Dobson instrument had been calibrated at intercomparisons with the World Standard Dobson instrument no. 83 (Boulder) and with the Regional Standard instrument no. 64 (Potsdam), while the Brewer instrument was calibrated several times with the Travelling Standard Brewer no. 17 (Canada). The differences between individual Brewer DS (direct sun) ozone data and Dobson ADDS are within plus or minus 3 percent with half of all differences within plus or minus 1 percent. Less than 0.7 percent of the systematic difference can be due to atmospheric SO2. Due to inadequate regression coefficients Brewer ZB (zenith blue) ozone measurements are by (3...4) percent higher than Dobson ADDS ozone values. M124 DS ozone data are systematically by (1...2) percent higher than Dobson ADDS ozone with 50 percent of the differences within plus or minus 4 percent, but with extreme differences up to plus or minus (20...25) percent. M124 ZB ozone values are by (3...5) percent higher than Dobson ADDS with all the differences within plus or minus 10 percent, i.e. the scatter of differences is smaller for ZB than for M 124 DS measurements, Results for differences in the daily mean ozone values are also addressed. The differences include the uncertainties in the ozone values derived from both types of measurements. They provide an indication of the uncertainty in ozone data and the comparability of ozone values derived from different types of instruments.

Feister, U.↗

Standardization of surface contamination analysis systems

Corrosion products, oils and greases can potentially degrade material bonding properties. The Marshall Space Flight Center (MSFC) Surface Contamination Analysis Team (SCAT) utilizes a variety of analytical equipment to detect identify and quantify contamination on metallic and non-metallic substrates. Analysis techniques include FT-IR Microscopy (FT-IR), Near Infrared Optical Fiber Spectrometry (NIR), Optically Stimulated Electron Emission (OSEE), Ultraviolet Fluorescence (UVF) and Ellipsometry. To insure that consistent qualitative and quantitative information are obtained, standards are required to develop analysis techniques, to establish instrument sensitivity to potential contaminants, and to develop calibration curves. This paper describes techniques for preparing and preserving contamination standards. Calibration of surface contamination analysis systems is discussed, and methods are presented for evaluating the effects of potential contaminants on bonding properties.

Boothe, Richard E.↗

Frequency calibration techniques

The techniques and standards used by the U. S. Army Metrology and Calibration Center for frequency calibration are discussed.

Williams, J. M., Jr.↗

Prototype ultrasonic instrument for quantitative testing

Ultrasonic instrument has been developed for use in quantitative nondestructive evaluation of material defects such as cracks, voids, inclusions, and unbonds. Instrument is provided with standard pulse source and transducer for each frequency range selected and includes integral aids that allow calibration to prescribed standards.

Lynworth, L. C.↗

Common Calibration Source for Monitoring Long-term Ozone Trends

Accurate long-term satellite measurements are crucial for monitoring the recovery of the ozone layer. The slow pace of the recovery and limited lifetimes of satellite monitoring instruments demands that datasets from multiple observation systems be combined to provide the long-term accuracy needed. A fundamental component of accurately monitoring long-term trends is the calibration of these various instruments. NASA s Radiometric Calibration and Development Facility at the Goddard Space Flight Center has provided resources to minimize calibration biases between multiple instruments through the use of a common calibration source and standardized procedures traceable to national standards. The Facility s 50 cm barium sulfate integrating sphere has been used as a common calibration source for both US and international satellite instruments, including the Total Ozone Mapping Spectrometer (TOMS), Solar Backscatter Ultraviolet 2 (SBUV/2) instruments, Shuttle SBUV (SSBUV), Ozone Mapping Instrument (OMI), Global Ozone Monitoring Experiment (GOME) (ESA), Scanning Imaging SpectroMeter for Atmospheric ChartographY (SCIAMACHY) (ESA), and others. We will discuss the advantages of using a common calibration source and its effects on long-term ozone data sets. In addition, sphere calibration results from various instruments will be presented to demonstrate the accuracy of the long-term characterization of the source itself.

Kowalewski, Matthew↗