At least 541 records · Page 30

The MIPAS balloon borne trace constitutent experiment

A novel cryogenic Fourier transform spectrometer (FTS) has been developed for limb emission measurements in the mid IR-region from balloon-borne platforms. The FTS is a rapid scanning interferometer using a modified Michelson arrangement which allows a spectral resolution of 0.04 cm(exp -1) to be achieved. Solid carbon-dioxide cooling of the spectrometer and liquid-helium cooling of the detectors provide adequate sensitivity. The line of sight can be stabilized in terms of azimuth and elevation. A three-mirror off-axis telescope provides good vertical resolution and straylight rejection. Calibration is performed by high elevation and internal blackbody measurements. Four balloon flights were performed, two of them during spring turn-around 1989 and 1990 over mid-latitudes (Aire sur L'Adour, France, 44 deg N) and two near the northern polar circle in winter 1992 (Esrange, Sweden, 68 deg N). Limb emission spectra were collected from 32 km to 39 km floating altitudes covering tangent heights between the lower troposphere and the floating altitude. The trace gases CO2, H2O, O3, CH4, N2O, HNO3, N2O5, ClONO2, CF2Cl2, CFCl3, CHF2Cl, CCl4, and C2H6 have been identified in the measured spectra. The 1989 data have been analyzed to retrieve profiles of O3, HNO3, CFCl3 and CF2Cl2. The flights over Kiruna have provided the first ever reported profile measurements of the key reservoir species ClONO2 and N2O5 inside the polar vortex.

Oelhaf, H.↗

An assessment of image reconstruction from balloon-borne and the IRAS data

Angular resolution and structural information from the far-infrared mapping of astronomical sources (Galactic star forming regions, spiral galaxies, etc.) made using the TIFR 1 m balloon-borne telescope and the IRAS have been compared. The effective wavelengths of the TIFR two-band photometer are 58 and 150 microns. From IRAS, the survey COADD data, additional observations (AO's) made with the survey detectors with different Macros (DPS, DSD, DPM), as well as the chopped photometric channel (CPC) data have been considered here. The observed signals have been processed using different deconvolution strategies, either based on a maximum entropy method (MEM) developed at TIFR or the HiRes package developed at IPAC. Relative merits of each of these, under different conditions of signal to noise ratio, are highlighted. The following sources have been selected for illustration: Carina complex, W31 region, IRAS 10361-5830 (all Galactic), M101 and M81 (extragalactic). The main conclusions are: far-infrared maps from MEM deconvolution of balloon-borne data have the best angular resolution; MEM deconvolution of IRAS AO's gives resolution comparable to HiRes but with less amount of computation, though the dynamic range in MEM maps is less than in HiRes maps.

Ghosh, S. K.↗

Neutron Induced Backgrounds In the MIXE X-Ray Detector at Balloon Altitudes

The MIXE detector developed at NASA/MSFC is designed for x-ray astronomy and consists of a multiwire proportional counter sensitive to photons less than 150 keV. The detector has been flown on several balloon flights with higher than expected background levels observed. Previous predictions of the detector background due to atmospheric gamma-ray and cosmic diffuse sources were much less (factor of 3) than flight background measurements. The work reported here was undertaken to determine if the additional contribution from gamma-rays generated by albedo and cosmic-ray induced neutrons in the detector and payload assembly could account for the background levels observed. Monte Carlo nuclear interaction and radiation transport simulations were made for the ambient cosmic-ray environment corresponding to a previous MEE balloon flight at 3 g/cm(exp 2) residual atmosphere and 42 N geomagnetic latitude. The omnidirectional albedo neutron spectrum and the GCR proton spectrum which were used as input to the calculations are shown. For the albedo angular distribution, the predicted up/down flux ratio of 2.5 was used together with the angular dependence measured by Preszler, et al.

Armstrong, T. W.↗

Long-Duration, Balloon-Borne Observations of Cosmic Microwave Background Anisotropy

Funds from this grant were used to support the continuing development of BOOMERANG, a 1.3 m, balloon-borne, attitude-stabilized telescope designed to measure the anisotropy of the Cosmic Microwave Background (CMB) on angular scales of 12 min to 10 degrees. By the end of the funding period covered by this grant, the fabrication of most of the BOOMERANG sub-systems was completed, and integration and test of the payload at Caltech had begun. The project was continued under a new grant from NASA and continuing funding from the NSF. Payload integration and test was completed in April, 1997. A campaign to Palestine, Texas, resulted in two test flights during 1997. A flight on August 12, 1997 was terminated on ascent due to a leaky balloon. The payload was successfully recovered, refurbished, and flown again on August 29, 1997. The second flight was completely successful, and qualified the payload for an LDB flight from McMurdo Stn., Antarctica, in December 1998.

Source record↗

A Balloon-Borne Cloud Condensation Nuclei Counter

A balloon-borne instrument was constructed for observations of vertical profiles of cloud condensation nucleus (CCN) concentrations, active at 1% supersaturation. Droplet concentration in the static thermal-gradient diffusion chamber is deduced from the amount of scattered laser light detected by a photodetector. The photodetector is calibrated using a video camera and computer system to count the number of droplets produced from NaCl aerosol. Preliminary data are available from nine early morning profiles obtained at Laramie, Wyoming, between June 1995 and January 1997. To complement the CCN measurements, instruments that measure condensation nuclei (CN) and aerosols with diameter greater than 0.30 micrometers (D(sub 0.3) were also included on the balloon package. CCN concentrations exhibited a general decrease from the surface to the top of the boundary layers, were generally uniform through well-mixed layers, and show variability above well-mixed layers. In general, the structure of the CCN profile appears to be closely related to the structure in the CN and D(sub 0.3) profiles. Summer profiles generally have CCN concentration greater than 200/cu cm up to 500 mbar, whereas winter profiles are less than 200/cu cm at all levels.

Delene, David J.↗

Vertical Profiles of Cloud Condensation Nuclei, Condensation Nuclei, Optical Aerosol, Aerosol Optical Properties, and Aerosol Volatility Measured from Balloons

Under the support of this grant a balloon-borne gondola containing a variety of aerosol instruments was developed and flown from Laramie, Wyoming, (41 deg N, 105 deg W) and from Lauder, New Zealand (45 deg S, 170 deg E). The gondola includes instruments to measure the concentrations of condensation nuclei (CN), cloud condensation nuclei (CCN), optically detectable aerosol (OA.) (r greater than or equal to 0.15 - 2.0 microns), and optical scattering properties using a nephelometer (lambda = 530 microns). All instruments sampled from a common inlet which was heated to 40 C on ascent and to 160 C on descent. Flights with the CN counter, OA counter, and nephelometer began in July 1994. The CCN counter was added in November 1994, and the engineering problems were solved by June 1995. Since then the flights have included all four instruments, and were completed in January 1998. Altogether there were 20 flights from Laramie, approximately 5 per year, and 2 from Lauder. Of these there were one or more engineering problems on 6 of the flights from Laramie, hence the data are somewhat limited on those 6 flights, while a complete data set was obtained from the other 14 flights. Good CCN data are available from 12 of the Laramie flights. The two flights from Lauder in January 1998 were successful for all measurements. The results from these flights, and the development of the balloon-bome CCN counter have formed the basis for five conference presentations. The heated and unheated CN and OA measurements have been used to estimate the mass fraction of the aerosol volatile, while comparisons of the nephelometer measurements were used to estimate the light scattering, associated with the volatile aerosol. These estimates were calculated for 0.5 km averages of the ascent and descent data between 2.5 km and the tropopause, near 11.5 km.

Deshler, T.↗

The HERO Program: High-Energy Replicated Optics for a Hard-X-Ray Balloon Payload

We are developing high-energy replicated optics for a balloon-borne hard-x-ray telescope. When completed, the telescope will have around 150 square cm of effective collecting area up to 65 keV, and an angular resolution of around 30 arc seconds, half power diameter. When used in conjunction with an array of focal plane imaging detectors, for which Gas Scintillation Proportional Counters are under development, the payload will provide unprecedented sensitivity for pointed observations in the hard-x-ray band. We will present an overview of the High Energy Replicated Optics (HERO) program together with test data from the first mirror units. The overall sensitivity of the full payload, when flown on long- and ultra-long-duration balloon flights, will be compared with past and planned satellite-borne hard-x-ray missions.

Ramsey, B. D.↗

Low-Density Silica Xerogel Capture of Leonids Meteor Storm Dust Candidates by Stratospheric Balloon Return

High altitude balloon (20 km) and low-density capture media were explored to return meteor-related dust during the November 1998 Leonids meteor storm. One 20-30 micron particle captured showed a characteristic signature of extraterrestrial origin, featuring high aluminum, magnesium and other non-volatile metals. The technique of balloon capture will be optimized for March and November 1999 reflights.

Noever, David↗

Leonid's Particle Analyses from Stratospheric Balloon Collection on Xerogel Surfaces

Recovered from a stratospheric balloon above 20 km on 17-18 November 1998, at least eight candidate microparticles were collected and analyzed from low-density silica xerogel collection plates. Capture time at Leonids' storm peak was validated locally along the balloon trajectory by direct video imaging of meteor fluence up to 24/hr above 98% of the Earth's atmosphere. At least one 30 micron particle agrees morphologically to a smooth, unmelted spherule and compares most closely in non-volatile elemental ratios (Mg/Si, Al/Si, and Fe/Si) to compositional data in surface/ocean meteorite collections. A Euclidean tree diagram based on composition makes a most probable identification as a non-porous stratospherically collected particle and a least probable identification as terrestrial matter or an ordinary chondrite. If of extraterrestrial origin, the mineralogical class would be consistent with a stony (S) type of silicate, olivine [(Mg,Fe)2SiO4] and pyroxene [(Mg, Fe)Si!O3)--or oxides, herecynite [(Fe,Mg) Al2O4].

Noever, David↗

Balloon-Borne Measurements of Total Reactive Nitrogen, Nitric Acid, and Aerosol in the Cold Arctic Stratosphere

Total reactive nitrogen (NO(Y)) between 15 and 29 km was measured for the first time on board a balloon within the Arctic cold vortex. Observations of HNO3, aerosol, and ozone were made by instruments on the same balloon gondola which was launched from Esrange, Sweden (68 deg N, 20 deg E) on January 23, 1989. The NO(y) mixing ratio was observed to increase very rapidly from 6 ppbv at 18 km altitude to a maximum of 21 ppbv at 21 km, forming a sharp layer with a thickness of about 2 km. A minimum in the NO(y) mixing ratio of 5 ppbv was found at 27 km. The measured HNO3 profile shows broad similarities to that of NO(y). This observation, together with the observed very low column amount of NO2, shows that NO(x) had been almost totally converted to HNO3, and that NO(y) was composed mainly of HNO3. The enhanced aerosol concentration between 19 and 22 km suggests that the maximum abundance of HNO3 trapped in the form of nitric acid trihydrate (NAT) was about 6 ppbv at 21 km. The sampled air parcels were highly supersaturated with respect to NAT. Although extensive denitrification throughout the stratosphere did not prevail, an indication of denitrification was found at altitudes of 27 and 22 km, and between 18 and 15 km.

Kondo, Y.↗

The Use of Large Lithium-Drifted, Germanium Diodes for Gamma-Ray Spectral Measurements at Balloon Altitudes

A series of balloon-borne experiments has been initiated at the Oak Ridge National Laboratory (ORNL) in cooperation with the Space Sciences Laboratory of the NASA G. C. Marshall Space Flight Center to determine the feasibility of using large (greater than 20 cc) lithium-drifted, germanium diodes to investigate the spectrum of atmospheric gamma rays (60 keV < E < 1.5 MeV) at altitudes corresponding to a few grams per cm (sup 2) residual atmosphere. The results of these measurements will also provide a basis for designing an appropriate shield for a multi-diode, highly directional gamma-ray spectrometer for use in astrophysical measurements. Two flights were accomplished during 1967 using the same two diodes and basic instrument package. Both flights were launched at the NCAR Scientific Balloon Flight Base, Palestine, Texas, and attained a float altitude of 117, 000 ft. The measured atmospheric gamma-ray spectrum shows at least one distinct line at 511 keV (annihilation radiation) superimposed on a continuous distribution of gamma rays attributable to both energy-degraded gamma rays and brems-strahlung photons. A second diode, encased in a passive shield of plastic and lead, shows the expected lines resulting from both neutron inelastic scattering and capture in the germanium. Data acquisition was accomplished on an event-by-event basis through the use of 512-channel, on-board ADC and word-generator circuits and a ground-based, on-line telemetry decoder. The decoder makes it possible to store the data in the memory of a modified pulse-height analyzer simultaneously with storage on magnetic tape. This provides a real-time visual observation of the data as it is accumulated and greatly facilitates preflight calibrations.

Chapman, G. T.↗

Data Acquisition and Prompt Analysis System for High Altitude Balloon Experiments

An inexpensive and simple data acquisition system has been developed for balloon borne experiments and has been tested with a gamma ray detector in a balloon flight launched from Palestine, Texas. The detector used for the test consisted of an NaI(T1) scintillation crystal encased in a 1/8 in. plastic scintillator-charged particle shield. The combination was viewed by a single photomultiplier and charged particle gating was accomplished by a conventional phoswich discriminator. The pulse height analysis of the NaI events, not associated with prompt charged particle interactions, is accomplished by converting to a time spectrum using an airborne height to time converter. A range of pulse widths from 5 microseconds to 250 microseconds corresponds to energy losses in NaI from 100 to 1000 keV. The time spectrum information, along with charged particle events and barometric pressure, is fed to a mixer which modulates a 252.4 Mc FM transmitter. The original scintillator spectrum is recovered on the ground utilizing conversion circuitry at the receiver video output and a 128 channel commercial pulse height analyzer. The charged particle events of standard time width are stored with the spectrum at a fixed channel position and are therefore represented by a sharp line riding on the lower part of the NaI energy loss spectrum. An energy loss greater than 1000 keV is presented by the maximum pulse width of the converter and stored in the last analyzer channel. Barometric pressure data is transmitted by low frequency modulation of the sme FM carrier. In flight operation, the receiver video output can be recorded on a wide band tape recorder and simultaneously analyzed by the 128 channel analyzer, or the telemetered data can be analyzed later. The flight system features high pulse resolution, essentially instantaneous time response, high data rate, and flexibility; and is of modest cost. A detailed description of the system and operating performance is discussed.

Sarkady, A. A.↗

HERO: High Energy Replicated Optics for a Hard-X-Ray Balloon Payload

We are developing high-energy grazing-incidence replicated optics for a balloon-borne hard-x-ray telescope. When completed, the instrument will have 170 cm2 of effective collecting area at 40 keV and 130 square cm at 60 keV with <= 30 arc seconds half power diameter. This payload will offer unprecedented sensitivity in the hard-x-ray region, with around 250 microCrab sensitivity on long-duration flights and 50-100 microCrab on ultra- long-duration balloon missions The payload consists of 16 mirror modules, each with 14 nested mirrors made from a high-strength nickel alloy, and a corresponding array of 16 focal plane detectors. An engineering demonstration flight is scheduled for the Spring of 2000, using just two mirror modules each with 3 shells, above a pair of gas-scintillation-proportional counters. This flight is intended to test a newly designed gondola pointing and aspect system and the stability of the optical bench design. The first scientific flight of the full payload is scheduled for the Fall of 2002. Full details of the payload and its capabilities will be presented together with data from various mirror-module tests. If available data from the first flight will also be presented.

Ramsey, B.↗

The Ultimate Mountaintop: Astronomy Aboard Stratospheric Balloons

As funding, for astronomy dwindles and the competition for observation time heats up, more astronomers may turn to balloons. Far above the Keck telescope on Hawaii's Mauna Kea, higher still than the hostile snowcapped peaks of Mt. Everest, there exists a 40-kilometer summit that will place their telescopes above 99% of the atmosphere. With the prospect of 100-day and even 1,000-day balloons, the climb to the summit is more and more tempting. Surely, given enough cash, most astronomers would opt for a lunar base or a platform beyond the Earth. Until then, many seem happy to settle for a stratospheric mountaintop.

Wanjek, Christopher↗

Exploring Mars with Balloons and Inflatable Rovers

Until now, the exploration of Mars has taken place with global coverage of the planet by satellites in orbit or with landers providing very detailed coverage of extremely limited local areas. New developments in inflatable technology, however, now offer the possibility of in situ surface and atmospheric global studies of Mars using very lightweight rovers and balloons that can travel hundreds or even thousands of kilometers relatively quickly and safely. Both systems are currently being tested at JPL; preliminary results show great promise. One of the balloon technologies offers the additional bonus of being able to land payloads on Mars much more gently than parachutes, yet with considerably less mass.

Jones, Jack A.↗

A Daytime Aspect Camera for Balloon Altitudes

We have designed, built, and flight-tested a new star camera for daytime guiding of pointed balloon-borne experiments at altitudes around 40km. The camera and lens are commercially available, off-the-shelf components, but require a custom-built baffle to reduce stray light, especially near the sunlit limb of the balloon. This new camera, which operates in the 600-1000 nm region of the spectrum, successfully provided daytime aspect information of approximately 10 arcsecond resolution for two distinct star fields near the galactic plane. The detected scattered-light backgrounds show good agreement with the Air Force MODTRAN models, but the daytime stellar magnitude limit was lower than expected due to dispersion of red light by the lens. Replacing the commercial lens with a custom-built lens should allow the system to track stars in any arbitrary area of the sky during the daytime.

Dietz, Kurt L.↗

Polar Balloon Experiment for Astrophysics Research (Polar BEAR)

A new balloon experiment is proposed for a long duration flight around the North Pole. The primary objective of the experiment is to measure the elemental energy spectra of high-energy cosmic rays in the region up to 10(exp 15) eV. The proposed instrument involves the combination of a large collecting area (approximately 1 x 1 square m) KLEM (Kinematic Lightweight Energy Meter) device with an ionization calorimeter having a smaller collecting area (approximately 0.5 x 0.5 square m) and integrated beneath the KLEM apparatus. This combination has several important advantages. Due to the large aperture (greater than 2 square m sr) of the KLEM device a large exposure factor can be achieved with a long duration balloon flight (2-4 weeks). The calorimeter will collect about 10% of the events already registered by KLEM and provide effective cross-calibration for both energy measurement methods. Details of the experiment and its astrophysical significance will be presented.

Bashindzhagyan, G.↗