SU-E-T-288: Dose Volume Population Histogram (DVPH): A New Method to Evaluate Intensity Modulated Proton Therapy Plans With Geometrical Uncertainties

Purpose: In Proton therapy, especially intensity modulated proton therapy(IMPT), the dose distribution shape is very sensitive to errors due to sharp dose gradients at the Bragg peaks. The concept of the conventional margin is based on the assumption that dose distribution is shifted rather than deformed due to geometrical uncertainties. The goal of this study is to access the validity of the margin concept as well as propose a new approach using Dose Volume Population Histogram (DVPH) in evaluating IMPT plans. Methods: For a prostate case, an intensity modulated proton therapy is optimized based on the conventional PTV based objective function. The plan is evaluated based on the PTV DVH and CTV DVPH (dose volume population histogram) which explicitly taking into account geometric uncertainties. The DVPH is calculated based on 2197 dose distributions at different CTV possible positions for both random and systematic errors. The DVPH with a 90% confidence level is used for the comparison. Results: The minimum dose of the CTV DVPH with a 90% confidence level is only about 18% of the prescribed dose, while the minimum dose of the PTV is 95%. For bladder DVHs, the D50 and D35 is 26% and 30%, compared to 65% and 70% of the prescribed dose from the bladder DVPH with 90% confidence level. Conclusion: The results showed that the PTV concept for ensuring the prescribed dose actually delivered to the CTV is invalid in proton therapy. The good PTV DVH might Result in an underdose to the target and should not be used for IMPT optimization. For OARs, the conventional evaluation approach underestimates dose volume end points. The new concept DVPH has been proved to provide a more accurate DVH evaluation in proton therapy.

60 APPLIED LIFE SCIENCES↗

SU-E-T-305: Dosimetric Comparison of Cyberknife Versus Linac Based VMAT Stereotactic Treatment Planning for Localised Prostate Cancer

Purpose: The purpose of this study was to compare dosimetric indices of Cyberknife versus Linac for localised prostate cancer Methods: In this study, twenty patients were taken from Cyberknife Multiplan TPS v 4.6.0. All these patients underwent hypo fractionated boost treatment for localised prostate cancer in Cyberknife with the prescription dose of 18Gy in 3 fractions. For each patient VMAT stereotactic plans were generated in Monaco TPS v 5.0 using Elekta beam modulator MLC machine for 6MV photon beam. The plans quality were evaluated by comparing dosimetry indices such that D95, D90, D5 for target volume and V100, V80, V50, V30 for critical organs. The p values were calculated for target and OAR to ascertain the significant differences. Results: For each case, D95 of target coverage was achieved with 100% prescription dose with p value of 0.9998. The p value for D90, D5 and V100 for linac and Cyberknife plans was 0.9938, 0.9918 and 0.9838 respectively. For rectum, rectum-PTV and bladder doses were significantly less in Cyberknife compared to linac plans. For rectum, rectum-PTV and bladder at V100 the p value is 0.2402, 0.002, and 0.1615 respectively. Other indices V80, V50 and V30 were comparable in both plans. Conclusion: This study demonstrated that both linac and Cyberknife plans were shown adequate target coverage, while in Cyberknife the treatment time is longer and more MUs to be delivered. However, better conformity, lesser doses to the critical organs and dose gradient outside target for localised prostate treatment were achieved in Cyberknife plans due to multiple non coplanar beam arrangements.

60 APPLIED LIFE SCIENCES↗

SU-E-T-393: Evaluation of Large Field IMRT Versus RapidArc Planning for Carcinoma Cervix with Para-Aotic Node Irradiation

Purpose: The objective of this work is to evaluate and compare Large field IMRT and RapidArc planning for Carcinoma Cervix and Para-aotic node irradiation. Methods: In this study, ten patients of Cervix with para-aotic node have been selected with PTV length 35+2cm. All plans were generated in Eclipse TPS V10.0 with Dynamic IMRT and RapidArc technique using 6MV photon energy. In IMRT planning, 7 fields were chosen to get optimal plan and in RapidArc, double Full arc clockwise and counter clockwise were used for planning. All the plans were generated with single isocenter and calculated using AAA dose algorithm. For all the cases the prescribed dose to PTV was same and the plan acceptance criteria is; 95% of the PTV volume should receive 100% prescribed dose. The tolerance doses for the OAR’s is also taken in to account. The evaluation criteria used for analysis are; 1) Homogeneity Index, 2) Conformity Index, 3) Mean Dose to OAR’s, 4)Total monitor units delivered. Results: DVH analysis were performed for both IMRT and RapidArc planning. In both the plans, 95% of PTV volume receives prescribed dose and maximum dose are less than 107%. The conformity index are same in both the techniques. The mean Homogeneity index are 1.036 and 1.053 for IMRT and RapidArc plan. The mean (mean + SD) dose of bladder and rectum in IMRT is 44.2+1.55, 42.05+2.52 and RapidArc is 46.66+1.6, 44.2+2.75 respectively. There is no significant difference found in Right Femoral head, Left Femoral head and Kidney doses. It is found that total MU’s are more in IMRT compared with RapidArc planning. Conclusion: In the case of cervix with Para-arotic node single isocenter irradiation, IMRT planning in large-field is better compared to RapidArc planning in terms of Homogeneity Index and mean dose of Bladder and Rectum.

60 APPLIED LIFE SCIENCES↗

SU-E-T-759: To Replan Or Not To Replan for Each Fraction Using Inverse Optimization for Multichannel Vaginal Cylinder

Purpose: This study investigates whether replanning each fraction for vaginal cuff HDR therapy using a multichannel cylinder (MC) and brachytherapy inverse optimization (BIO) provides dosimetric benefits to organs-at-risk (OAR). The goal was to appropriately cover the target and limit dose to OAR, as well as evaluate dosimetric changes for each fraction, while doing this in a timely and cost effective manner. Methods: From an initial selection of 57 patients that were treated with 3 fractions using a MC and BIO, a subset of n=12 patients was selected based on the criterion that one plan was used for all 3 fractions. A simulation CT was acquired prior to each fraction. CT scans for fractions 2 and 3 were fused to the initial CT. Contours for the bladder and rectum were manually drawn on CTs for all 3 fractions, and the clinical treatment volume (PTVeval) was defined. Cylinders were reconstructed using applicator modeling library, influencing time and cost effectiveness. Planning objectives were at least 95% prescription dose to 95% (D95%) of target volume and limiting high dose to OAR. Dose to 2 cm{sup 3} (D2cc) for each OAR was analyzed using a t-test. Results: This study concentrated on comparing 2cm{sup 3} of highest dose to OAR (D2cc), for each fraction for the plans that were used to treat all 3 fraction. Based on statistical analysis, using the initial plan for fractions 2 and 3 resulted in approximately 6% change to the highest D2cc of the bladder (p=0.03). Conclusion: Performing CT fusion and contours of each OAR on each fraction allows objective plan evaluation and supports decision making on the necessity of replanning based on improved dose sparing for OAR. Future studies will investigate the effects of replanning on maximum dose (D0.1cc) using the same physician-drawn OAR contours to avoid subjectivity.

60 APPLIED LIFE SCIENCES↗

SU-E-T-807: VMAT Vs. DIMRT Vs. SsIMRT Assessing the Dosimetric Parameters of Cervical Carcinoma Treatment with a 20-Patient Sample

Purpose: The purpose of this study is to assess the dosimetric parameters of cervical carcinoma treatment using 3 different radiation therapy delivery Methods: volumetric-modulated arc therapy (VMAT), the static-field dynamic multileaf collimator intensity-modulated radiation therapy (dIMRT) and the static-field step-and-shoot intensity-modulated radiotherapy (ssIMRT). Methods: Twenty patients with cervical carcinoma were selected to be planned with dual arc VMAT, dIMRT and ssIMRT using Monaco 3.3 TPS on the Axesse™ linear accelerator in this investigation. The total dose of the planning target volume (PTV) is 60Gy. The homogeneity index (HI), conformity index (CI), dose volume histograms (DVHs), delivery efficiency, dose of organs at risks (bladder, rectum, and femoral heads), were all measured. Results: Dose distribution in 3 different radiation therapy delivery methods satisfied clinical requirements. Mean HI of PTV with VMAT, dIMRT and ssIMRT is 1.08, 1.10, and 1.09 (p>0.05). Mean CI of PTV with VMAT, dIMRT and ssIMRT is 0.82, 0.8 and 0.8 (p>0.05). For the DVH of V10, V20 and V30 in bladder, there was a significant difference: VMAT>dIMRT=ssIMRT (p <0.05). For the DVH of V40 and V50, there was a significant difference: VMAT dIMRT >ssIMRT (p <0.05). Conclusion: The results show that VMAT has a great advantage in delivery efficiency than dIMRT and ssIMRT, without compromise to the PTV coverage, HI and CI. The delivery methods should be considered under the actual cervical carcinoma radiotherapy situation.

60 APPLIED LIFE SCIENCES↗

SU-F-BRB-10: A Statistical Voxel Based Normal Organ Dose Prediction Model for Coplanar and Non-Coplanar Prostate Radiotherapy

Purpose: Knowledge learned from previous plans can be used to guide future treatment planning. Existing knowledge-based treatment planning methods study the correlation between organ geometry and dose volume histogram (DVH), which is a lossy representation of the complete dose distribution. A statistical voxel dose learning (SVDL) model was developed that includes the complete dose volume information. Its accuracy of predicting volumetric-modulated arc therapy (VMAT) and non-coplanar 4π radiotherapy was quantified. SVDL provided more isotropic dose gradients and may improve knowledge-based planning. Methods: 12 prostate SBRT patients originally treated using two full-arc VMAT techniques were re-planned with 4π using 20 intensity-modulated non-coplanar fields to a prescription dose of 40 Gy. The bladder and rectum voxels were binned based on their distances to the PTV. The dose distribution in each bin was resampled by convolving to a Gaussian kernel, resulting in 1000 data points in each bin that predicted the statistical dose information of a voxel with unknown dose in a new patient without triaging information that may be collectively important to a particular patient. We used this method to predict the DVHs, mean and max doses in a leave-one-out cross validation (LOOCV) test and compared its performance against lossy estimators including mean, median, mode, Poisson and Rayleigh of the voxelized dose distributions. Results: SVDL predicted the bladder and rectum doses more accurately than other estimators, giving mean percentile errors ranging from 13.35–19.46%, 4.81–19.47%, 22.49–28.69%, 23.35–30.5%, 21.05–53.93% for predicting mean, max dose, V20, V35, and V40 respectively, to OARs in both planning techniques. The prediction errors were generally lower for 4π than VMAT. Conclusion: By employing all dose volume information in the SVDL model, the OAR doses were more accurately predicted. 4π plans are better suited for knowledge-based planning than the VMAT plans that are strongly biased in its dose gradient orientation. This project is supported by Varian Medical Systems.

60 APPLIED LIFE SCIENCES↗

MO-G-304-02: Knowledge Based DVH Prediction Using a Geometric Dose Transform

Purpose: To demonstrate a novel method for predicting patient dose-volume histograms (DVHs) using a prior database of optimized radiotherapy treatment plans. Such predicted DVHs could be useful for automating treatment planning. Methods: Our initial demonstration utilized a database of 100 prostate intensity-modulated radiotherapy (IMRT) data-sets. Each data-set contained a CT image with contours of the planning target volume (PTV), rectum, and bladder, the parameters of a clinically approved IMRT plan, and a corresponding simulated dose distribution. We applied a novel geometric transformation to remove the influence of the PTV size, shape, and location on the dose distribution. We termed the transformed distribution the geometrically normalized dose distribution (GNDD). This normalization transform was applied to 80 data-sets randomly selected from the database, and a population GNDD was computed as the average. Next, the population GNDD was mapped onto each of the remaining 20 patient datasets using the reverse of the geometric normalization transform, and predicted DVHs were calculated from the reverse transformed dose distributions (GNDD-DVHs). In addition, a state of the art machine learning based method from the literature was tested for comparison. Results: DVH prediction accuracy was quantified by calculating the relative root mean squared error (rRMSE) on predicted DVHs for the 20 test patients using their known DVHs. For bladder, rectum, and PTV average rRMSEs for the GNDD method were 9.7 ± 4.2%, 13.9 ± 6.0%, and 2.3 ± 0.5% respectively. Prediction results using GNDD were roughly equivalent to that from the machine learning method. Conclusion: We developed a new method for predicting DVH curves from a database of prior patient plans. We demonstrated that our simple approach achieves accuracy comparable to a method using a complicated machine learning based approach.

60 APPLIED LIFE SCIENCES↗

MO-F-CAMPUS-I-05: Radiation Dosimetry of 99mTc-IDA-D-[c(RGDfK)]2, a SPECT Agent for Angiogenesis Imaging

Purpose: Tc-99m labeled IDA-D-[c(RGDfK){sub 2} ( {sup 99m}Tc-RGD) is a recently developed radiotracer for gamma camera or single photon emission computed tomography (SPECT) imaging and promising agent for the visualization of angiogenesis. In this study, we investigated the internal radiation dosimetry of {sup 99m}Tc-RGD in humans. Methods: Six normal controls (F:M=4:2; 68.3±3.2 years; 56.5±10.7 kg) were participated in this study. Simultaneous anterior and posterior scans of whole-body were performed using dual head gamma camera system. Before the emission scan, transmission scan was performed just before injection of {sup 99m}Tc-RGD using Co-57 flood source. After an intravenous injection of 388.7±29.3 MBq of {sup 99m}Tc-RGD, six serial emission scans were performed at 0, 1, 2, 4, 8 and 24 hours post-injection. The anterior and posterior images were geometrically averaged and attenuation correction was applied using transmission scan image. Regions of interest (ROIs) were drawn on liver, gallbladder, kidneys, urinary bladder, spleen, brain, and large intestine. Time activity curves were obtained from serial emission scan and ROIs. The number of disintegrations per unit activity administered (residence time) were calculated from the area under the curve of time activity curves and injected dose of each patient. Finally, the radiation dose for each organ and effective doses were obtained using OLINDA/EXM 1.1 software and residence time. Results: High radiation doses were reported on renal and biliary excretion tracks such as urinary bladder wall, upper large intestine, kidneys, liver and gallbladder wall and their doses were 19.15±6.84, 19.28±4.78, 15.67±0.90, 9.13±1.71 and 9.09±2.03 µGy/MBq, respectively. The effective dose and effective dose equivalent were 5.08±0.53 and 7.11±0.58 µSv/MBq, respectively. Conclusion: We evaluated the radiation dose of 99mTc-RGD, which has an acceptable effective radiation dose compare to the other Tc-99m labeled radio-tracers.

60 APPLIED LIFE SCIENCES↗

WE-G-BRD-07: Automated MR Image Standardization and Auto-Contouring Strategy for MRI-Based Adaptive Brachytherapy for Cervix Cancer

Purpose: MRI-based adaptive brachytherapy (ABT) is an emerging treatment modality for patients with gynecological tumors. However, MR image intensity non-uniformities (IINU) can vary from fraction to fraction, complicating image interpretation and auto-contouring accuracy. We demonstrate here an automated MR image standardization and auto-contouring strategy for MRI-based ABT of cervix cancer. Methods: MR image standardization consisted of: 1) IINU correction using the MNI N3 algorithm, 2) noise filtering using anisotropic diffusion, and 3) signal intensity normalization using the volumetric median. This post-processing chain was implemented as a series of custom Matlab and Java extensions in MIM (v6.4.5, MIM Software) and was applied to 3D T2 SPACE images of six patients undergoing MRI-based ABT at 3T. Coefficients of variation (CV=σ/µ) were calculated for both original and standardized images and compared using Mann-Whitney tests. Patient-specific cumulative MR atlases of bladder, rectum, and sigmoid contours were constructed throughout ABT, using original and standardized MR images from all previous ABT fractions. Auto-contouring was performed in MIM two ways: 1) best-match of one atlas image to the daily MR image, 2) multi-match of all previous fraction atlas images to the daily MR image. Dice’s Similarity Coefficients (DSCs) were calculated for auto-generated contours relative to reference contours for both original and standardized MR images and compared using Mann-Whitney tests. Results: Significant improvements in CV were detected following MR image standardization (p=0.0043), demonstrating an improvement in MR image uniformity. DSCs consistently increased for auto-contoured bladder, rectum, and sigmoid following MR image standardization, with the highest DSCs detected when the combination of MR image standardization and multi-match cumulative atlas-based auto-contouring was utilized. Conclusion: MR image standardization significantly improves MR image uniformity. The combination of MR image standardization and multi-match cumulative atlas-based auto-contouring produced the highest DSCs and is a promising strategy for MRI-based ABT for cervix cancer.

60 APPLIED LIFE SCIENCES↗

SU-C-207B-03: A Geometrical Constrained Chan-Vese Based Tumor Segmentation Scheme for PET

Purpose: Accurate segmentation of tumor in PET is challenging when part of tumor is connected with normal organs/tissues with no difference in intensity. Conventional segmentation methods, such as thresholding or region growing, cannot generate satisfactory results in this case. We proposed a geometrical constrained Chan-Vese based scheme to segment tumor in PET for this special case by considering the similarity between two adjacent slices. Methods: The proposed scheme performs segmentation in a slice-by-slice fashion where an accurate segmentation of one slice is used as the guidance for segmentation of rest slices. For a slice that the tumor is not directly connected to organs/tissues with similar intensity values, a conventional clustering-based segmentation method under user’s guidance is used to obtain an exact tumor contour. This is set as the initial contour and the Chan-Vese algorithm is applied for segmenting the tumor in the next adjacent slice by adding constraints of tumor size, position and shape information. This procedure is repeated until the last slice of PET containing tumor. The proposed geometrical constrained Chan-Vese based algorithm was implemented in Matlab and its performance was tested on several cervical cancer patients where cervix and bladder are connected with similar activity values. The positive predictive values (PPV) are calculated to characterize the segmentation accuracy of the proposed scheme. Results: Tumors were accurately segmented by the proposed method even when they are connected with bladder in the image with no difference in intensity. The average PPVs were 0.9571±0.0355 and 0.9894±0.0271 for 17 slices and 11 slices of PET from two patients, respectively. Conclusion: We have developed a new scheme to segment tumor in PET images for the special case that the tumor is quite similar to or connected to normal organs/tissues in the image. The proposed scheme can provide a reliable way for segmenting tumors.

60 APPLIED LIFE SCIENCES↗

SU-D-BRB-02: Combining a Commercial Autoplanning Engine with Database Dose Predictions to Further Improve Plan Quality

Purpose: Database dose predictions and a commercial autoplanning engine both improve treatment plan quality in different but complimentary ways. The combination of these planning techniques is hypothesized to further improve plan quality. Methods: Four treatment plans were generated for each of 10 head and neck (HN) and 10 prostate cancer patients, including Plan-A: traditional IMRT optimization using clinically relevant default objectives; Plan-B: traditional IMRT optimization using database dose predictions; Plan-C: autoplanning using default objectives; and Plan-D: autoplanning using database dose predictions. One optimization was used for each planning method. Dose distributions were normalized to 95% of the planning target volume (prostate: 8000 cGy; HN: 7000 cGy). Objectives used in plan optimization and analysis were the larynx (25%, 50%, 90%), left and right parotid glands (50%, 85%), spinal cord (0%, 50%), rectum and bladder (0%, 20%, 50%, 80%), and left and right femoral heads (0%, 70%). Results: All objectives except larynx 25% and 50% resulted in statistically significant differences between plans (Friedman’s χ{sup 2} ≥ 11.2; p ≤ 0.011). Maximum dose to the rectum (Plans A-D: 8328, 8395, 8489, 8537 cGy) and bladder (Plans A-D: 8403, 8448, 8527, 8569 cGy) were significantly increased. All other significant differences reflected a decrease in dose. Plans B-D were significantly different from Plan-A for 3, 17, and 19 objectives, respectively. Plans C-D were also significantly different from Plan-B for 8 and 13 objectives, respectively. In one case (cord 50%), Plan-D provided significantly lower dose than plan C (p = 0.003). Conclusion: Combining database dose predictions with a commercial autoplanning engine resulted in significant plan quality differences for the greatest number of objectives. This translated to plan quality improvements in most cases, although special care may be needed for maximum dose constraints. Further evaluation is warranted in a larger cohort across HN, prostate, and other treatment sites. This work is supported by Philips Radiation Oncology Systems.

60 APPLIED LIFE SCIENCES↗

SU-F-J-62: Assessment of Dose Changes Due to Anterior-Posterior Patient Separation During Daily MVCT Scans

Purpose: To determine the effects of patient separation on absolute dose and dose distribution in patients undergoing pelvic radiotherapy on TomoTherapy. Methods: An Alderson RANDO phantom with 4cm of bolus was imaged on a CT simulator and the resulting scans were contoured as a whole pelvic case. Using TomoTherapy Planning Station, the plan was designed to give 45 Gy to 95% of the treatment volume in 25 fractions. TomoTherapy MVCT scans were performed on the RANDO phantom with 2cm and 4cm of bolus removed to simulate visible changes in a patient’s anatomy. The MVCT images were rigidly registered with planning CT images on TomoTherapy Planned Adaptive. The original fluence was recalculated on the MVCT images and changes in dose distribution due to patient separation were quantified by the changes in DVHs for the target volume and the organs at risk. Results: Patient separation difference equivalent to 2cm and 4cm in anterior-posterior direction resulted in an increase of the PTV D50 and maximum PTV dose of 5.6%, 6.2% for 2cm and 7.7%, 10.4% for 4cm, respectively. For the 2cm change, D50 and maximum doses to organs at risk increased by 6.5%, 7.1% in the bladder, 4.9%, 4.8% in the rectum, and 5.3%, 6.6% in the bowel. For the 4cm change, D50 and maximum doses increased by 10.7%, 12.2% in the bladder, 5.9%, 6.1% in the rectum, and 7.7%, 10.1% in the bowel. Conclusion: This research indicates that, without any changes to the structures, patient separation in the anterior-posterior direction can affect the dose distribution for the PTV and organs at risk. These results can assist physicians in determining if obtaining a new CT simulation set and replanning is necessary for pelvic patients on TomoTherapy.

60 APPLIED LIFE SCIENCES↗

SU-F-J-81: Evaluation of Automated Deformable Registration Between Planning Computed Tomography (CT) and Daily Cone Beam CT Images Over the Course of Prostate Cancer Radiotherapy

Purpose: To compute daily dose delivered during radiotherapy, deformable registration needs to be relatively fast, automated, and accurate. The aim of this study was to evaluate the performance of commercial deformable registration software for deforming between two modalities: planning computed tomography (pCT) images acquired for treatment planning and cone beam (CB) CT images acquired prior to each fraction of prostate cancer radiotherapy. Methods: A workflow was designed using MIM Software™ that aligned and deformed pCT into daily CBCT images in two steps: (1) rigid shifts applied after daily CBCT imaging to align patient anatomy to the pCT and (2) normalized intensity-based deformable registration to account for interfractional anatomical variations. The physician-approved CTV and organ and risk (OAR) contours were deformed from the pCT to daily CBCT over the course of treatment. The same structures were delineated on each daily CBCT by a radiation oncologist. Dice similarity coefficient (DSC) mean and standard deviations were calculated to quantify the deformable registration quality for prostate, bladder, rectum and femoral heads. Results: To date, contour comparisons have been analyzed for 31 daily fractions of 2 of 10 of the cohort. Interim analysis shows that right and left femoral head contours demonstrate the highest agreement (DSC: 0.96±0.02) with physician contours. Additionally, deformed bladder (DSC: 0.81±0.09) and prostate (DSC: 0.80±0.07) have good agreement with physician-defined daily contours. Rectum contours have the highest variations (DSC: 0.66±0.10) between the deformed and physician-defined contours on daily CBCT imaging. Conclusion: For structures with relatively high contrast boundaries on CBCT, the MIM automated deformable registration provided accurate representations of the daily contours during treatment delivery. These findings will permit subsequent investigations to automate daily dose computation from CBCT. However, improved methods need to be investigated to improve deformable results for rectum contours.

60 APPLIED LIFE SCIENCES↗

SU-F-J-85: Evaluation of the Velocity Deformable Image Registration Algorithm

Purpose: To perform validation and commissioning of a commercial deformable image registration (DIR) algorithm (Velocity, Varian Medical Systems) for numerous clinical sites using single and multi-modality images. Methods: In this retrospective study, the DIR algorithm was evaluated for 10 patients in each of the following body sites: head and neck (HN), prostate, liver, and gynecological (GYN). HN DIRs were evaluated from planning (p)CT to re-pCT and pCTs to daily CBCTs using dice similarity coefficients (DSC) of corresponding anatomical structures. Prostate DIRs were evaluated from pCT to CBCTs using DSC and target registration error (TRE) of implanted RF beacons within the prostate. Liver DIRs were evaluated from pMR to pCT using DSC and TRE of vessel bifurcations. GYN DIRs were evaluated between fractionated brachytherapy MRIs using DSC of corresponding anatomical structures. Results: Analysis to date has given average DSCs for HN pCT-to-(re)pCT DIR for the brainstem, cochleas, constrictors, spinal canal, cord, esophagus, larynx, parotids, and submandibular glands as 0.88, 0.65, 0.67, 0.91, 0.77, 0.69, 0.77, 0.87, and 0.71, respectively. Average DSCs for HN pCT-to-CBCT DIR for the constrictors, spinal canal, esophagus, larynx, parotids, and submandibular glands were 0.64, 0.90, 0.62, 0.82, 0.75, and 0.69, respectively. For prostate pCT-to-CBCT DIR the DSC for the bladder, femoral heads, prostate, and rectum were 0.71, 0.82, 0.69, and 0.61, respectively. Average TRE using implanted beacons was 3.35 mm. For liver pCT-to-pMR, the average liver DSC was 0.94 and TRE was 5.26 mm. For GYN MR-to-MR DIR the DSC for the bladder, sigmoid colon, GTV, and rectum were 0.79, 0.58, 0.67, and 0.76, respectively. Conclusion: The Velocity DIR algorithm has been evaluated over a number of anatomical sites. This work functions to document the uncertainties in the DIR in the commissioning process so that these can be accounted for in the development of downstream clinical processes. This work was supported in part by a co-development agreement with Varian Medical Systems.

60 APPLIED LIFE SCIENCES↗

SU-F-J-145: MRI-Guided Interventional Boost Radiotherapy for Rectal Cancer: Investigating the Feasibility of Adapting the Anatomy

Purpose: The recent development of an MRI-linac allows adaptation of treatments to the anatomy of the moment. This anatomy, in turn, could be altered into a more favorable situation for radiotherapy purposes. The purpose of this study is to investigate the potential dosimetric benefits of manipulating rectal anatomy in MRI-guided interventional external-beam radiotherapy for rectal cancer. Methods: For this retrospective analysis, four patients (1M/3F) diagnosed with rectal cancer were included. These underwent MR-imaging using sonography transmission gel as endorectal contrast at time of diagnosis and standard, non-contrast, MR-imaging prior to radiotherapy planning. In the contrast scan, the rectum is inflated by the inserted contrast gel, thereby potentially increasing the distance between tumor and the organs-at-risk (OAR). Both anatomies were delineated and 7- beam IMRT-plans were calculated for both situations (RT-standard and RT-inflated), using in-house developed treatment planning software. Each plan was aimed to deliver 15Gy to the planning target volume (PTV; tumor+3mm margin) with a D99>95% and Dmax<120% of the planned dose. The D2cc dose to the OAR were then compared for both situations. Results: At equal (or better) target coverage, we found a mean reduction in D2cc of 4.1Gy/237% [range 2.6Gy–6.3Gy/70%–621%] for the bladder and of 2.0Gy/145% [range −0.7Gy–7.9Gy/−73%–442%] for the small-bowel, for the RT-inflated compared to the RT-standard plans. For the three female patients, a reduction in D2cc of 5.2Gy/191% [range 3.2Gy–9.2Gy/44%–475%] for the gynecological organs was found. We found all D2cc doses to be better for the RT-inflated plans, except for one patient for whom the bladder D2cc dose was slightly increased. Conclusion: Reduction of OAR dose by manipulation of anatomy is feasible. Inflation of the rectum results in more distance between OAR and PTV. This leads to a substantial reduction in dose to OAR at equal or better target coverage.

60 APPLIED LIFE SCIENCES↗

SU-F-T-18: The Importance of Immobilization Devices in Brachytherapy Treatments of Vaginal Cuff

Purpose: High dose rate brachytherapy is a highly localized radiation therapy that has a very high dose gradient. Thus one of the most important parts of the treatment is the immobilization. The smallest movement of the patient or applicator can result in dose variation to the surrounding tissues as well as to the tumor to be treated. We will revise the ML Cylinder treatments and their localization challenges. Methods: A retrospective study of 25 patients with 5 treatments each looking into the applicator’s placement in regard to the organs at risk. Motion possibilities for each applicator intra and inter fractionation with their dosimetric implications were covered and measured in regard with their dose variance. The localization immobilization devices used were assessed for the capability to prevent motion before and during the treatment delivery. Results: We focused on the 100% isodose on central axis and a 15 degree displacement due to possible rotation analyzing the dose variations to the bladder and rectum walls. The average dose variation for bladder was 15% of the accepted tolerance, with a minimum variance of 11.1% and a maximum one of 23.14% on the central axis. For the off axis measurements we found an average variation of 16.84% of the accepted tolerance, with a minimum variance of 11.47% and a maximum one of 27.69%. For the rectum we focused on the rectum wall closest to the 120% isodose line. The average dose variation was 19.4%, minimum 11.3% and a maximum of 34.02% from the accepted tolerance values Conclusion: Improved immobilization devices are recommended. For inter-fractionation, localization devices are recommended in place with consistent planning in regards with the initial fraction. Many of the present immobilization devices produced for external radiotherapy can be used to improve the localization of HDR applicators during transportation of the patient and during treatment.

60 APPLIED LIFE SCIENCES↗

SU-F-T-29: The Important of Each Fraction Image-Guided Planning for Postoperative HDR-Brachytherapy in Endometrial Carcinoma

Purpose: Cylindrical applicators are often used for postoperative HDRbrachytherapy in endometrial carcinoma. It has been considered that dosimetric variation between fractions for this treatment is minimal and might not be necessary to perform treatment planning for every fractions. At our institute, it is traditional to perform treatment planning with CT simulation on the first fraction and uses this plan for the rest of treatment. This study was aim to evaluate the errors of critical structure doses between the fractions when simulation and planning were done for first fraction only. Methods: Treatment plans of 10 endometrial carcinoma patients who received postoperative HDR-brachytherapy and underwent CT-simulation for every HDR-fractions at our department were retrospectively reviewed. All of these patients were treated with cylindrical applicator and prescribed dose 15Gy in 3 fractions to 0.5cm from vaginal surface. The treatment plan from the first fraction was used to simulate in second and third CT-simulation. Radiation dose for critical structures in term of Dose-to-2cc (D2cc) were evaluated and compared between planning CT. Results: The D2cc for bladder and rectum were evaluated. For bladder, the mean error of D2cc estimation for second and third fractions was 7.6% (0.1–20.1%, SD=5.7). And the mean error for D2cc of rectum was 8.5% (0.1–29.4%, SD=8.5). Conclusion: The critical structure doses could be significant difference between fractions which may affects treatment outcomes or toxicities. From our data, image-guided brachytherapy at least with CT-Simulation should be done for every treatment fractions.

60 APPLIED LIFE SCIENCES↗

SU-F-T-37: Dosimetric Evaluation of Planned Versus Decay Corrected Treatment Plans for the Treatment of Tandem-Based Cervical HDR Brachytherapy

Purpose: This study evaluated dosimetric parameters for actual treatment plans versus decay corrected treatment plans for cervical HDR brachytherapy. Methods: 125 plans of 25 patients, who received 5 fractions of HDR brachytherapy, were evaluated in this study. Dose was prescribed to point A (ICRU-38) and High risk clinical tumor volume (HR-CTV) and organs at risk (OAR) were, retrospectively, delineated on original CT images by treating physician. First HDR plan was considered as reference plan and decay correction was applied to calculate treatment time for subsequent fractions, and was applied, retrospectively, to determine point A, HR-CTV D90, and rectum and bladder doses. Results: The differences between mean point A reference doses and the point A doses of the plans computed using decay times were found to be 1.05%±0.74% (−2.26% to 3.26%) for second fraction; −0.25%±0.84% (−3.03% to 3.29%) for third fraction; 0.04%±0.70% (−2.68% to 2.56%) for fourth fraction and 0.30%±0.81% (−3.93% to 2.67%) for fifth fraction. Overall mean point A dose difference, for all fractions, was 0.29%±0.38% (within ± 5%). Mean rectum and bladder dose differences were calculated to be −3.46%±0.12% and −2.47%±0.09%, for points, respectively, and −1.72%±0.09% and −0.96%±0.06%, for D2cc, respectively. HR-CTV D90 mean dose difference was found to be −1.67% ± 0.11%. There was no statistically significant difference between the reference planned point A doses and that calculated using decay time to the subsequent fractions (p<0.05). Conclusion: This study reveals that a decay corrected treatment will provide comparable dosimetric results and can be utilized for subsequent fractions of cervical HDR brachytherapy instead of actual treatment planning. This approach will increase efficiency, decrease workload, reduce patient observation time between applicator insertion and treatment delivery. This would be particularly useful for institutions with limited resources or large patient populations with limited access to care.

60 APPLIED LIFE SCIENCES↗