SEARCH · Engineering Papers
Results for “Animals”
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Establishment of Microbeam Radiation Therapy at a Small-Animal Irradiator
Microbeam radiation therapy is a preclinical concept in radiation oncology. It spares normal tissue more effectively than conventional radiation therapy at equal tumor control. The radiation field consists of peak regions with doses of several hundred gray, whereas doses between the peaks (valleys) are below the tissue tolerance level. Widths and distances of the beams are in the submillimeter range for microbeam radiation therapy. A similar alternative concept with beam widths and distances in the millimeter range is presented by minibeam radiation therapy. Although both methods were developed at large synchrotron facilities, compact alternative sources have been proposed recently.
Real-time three-dimensional color doppler evaluation of the flow convergence zone for quantification of mitral regurgitation: Validation experimental animal study and initial clinical experience
BACKGROUND: Pitfalls of the flow convergence (FC) method, including 2-dimensional imaging of the 3-dimensional (3D) geometry of the FC surface, can lead to erroneous quantification of mitral regurgitation (MR). This limitation may be mitigated by the use of real-time 3D color Doppler echocardiography (CE). Our objective was to validate a real-time 3D navigation method for MR quantification. METHODS: In 12 sheep with surgically induced chronic MR, 37 different hemodynamic conditions were studied with real-time 3DCE. Using real-time 3D navigation, the radius of the largest hemispherical FC zone was located and measured. MR volume was quantified according to the FC method after observing the shape of FC in 3D space. Aortic and mitral electromagnetic flow probes and meters were balanced against each other to determine reference MR volume. As an initial clinical application study, 22 patients with chronic MR were also studied with this real-time 3DCE-FC method. Left ventricular (LV) outflow tract automated cardiac flow measurement (Toshiba Corp, Tokyo, Japan) and real-time 3D LV stroke volume were used to quantify the reference MR volume (MR volume = 3DLV stroke volume - automated cardiac flow measurement). RESULTS: In the sheep model, a good correlation and agreement was seen between MR volume by real-time 3DCE and electromagnetic (y = 0.77x + 1.48, r = 0.87, P <.001, delta = -0.91 +/- 2.65 mL). In patients, real-time 3DCE-derived MR volume also showed a good correlation and agreement with the reference method (y = 0.89x - 0.38, r = 0.93, P <.001, delta = -4.8 +/- 7.6 mL). CONCLUSIONS: real-time 3DCE can capture the entire FC image, permitting geometrical recognition of the FC zone geometry and reliable MR quantification.
Modulation of Neuroinflammation by Low-Dose Radiation Therapy in an Animal Model of Alzheimer's Disease
Recently, several studies have reported that low-dose radiation therapy (RT) suppresses the release of proinflammatory cytokines in inflammatory-degenerative disorders, including Alzheimer disease (AD). AD is the most common cause of dementia, and neuroinflammation is one of the major contributing factors in AD pathogenesis. Therefore, low-dose RT may be used clinically for treating AD. However, the appropriate doses, effects, and underlying mechanisms of RT in AD have not been determined. In this study, we aimed to determine the appropriate RT dose and schedule for AD treatment and to investigate the therapeutic effects and mechanisms of low-dose RT in AD.
Solar Energy-driven Land-cover Change Could Alter Landscapes Critical to Animal Movement in the Continental United States
Not Available
Ammonia Retention in Biowaste via Low-Temperature-Plasma-Synthesized Nitrogen Oxyacids: Toward Sustainable Upcycling of Animal Waste
Not Available
Image quality assessment for CT used on small animals
Image acquisition on a CT scanner is nowadays necessary in almost any kind of medical study. Its purpose, to produce anatomical images with the best achievable quality, implies the highest diagnostic radiation exposure to patients. Image quality can be measured quantitatively based on parameters such as noise, uniformity and resolution. This measure allows the determination of optimal parameters of operation for the scanner in order to get the best diagnostic image. A human Phillips CT scanner is the first one minded for veterinary-use exclusively in Colombia. The aim of this study was to measure the CT image quality parameters using an acrylic phantom and then, using the computational tool MATLAB, determine these parameters as a function of current value and window of visualization, in order to reduce dose delivery by keeping the appropriate image quality.
Lab-on-a-Fish: Wireless, Miniaturized, Fully Integrated, Implantable Biotelemetric Tag for Real-Time In Vivo Monitoring of Aquatic Animals
Not Available
Interactive lung segmentation in abnormal human and animal chest CT scans
Purpose: Many medical image analysis systems require segmentation of the structures of interest as a first step. For scans with gross pathology, automatic segmentation methods may fail. The authors’ aim is to develop a versatile, fast, and reliable interactive system to segment anatomical structures. In this study, this system was used for segmenting lungs in challenging thoracic computed tomography (CT) scans. Methods: In volumetric thoracic CT scans, the chest is segmented and divided into 3D volumes of interest (VOIs), containing voxels with similar densities. These VOIs are automatically labeled as either lung tissue or nonlung tissue. The automatic labeling results can be corrected using an interactive or a supervised interactive approach. When using the supervised interactive system, the user is shown the classification results per slice, whereupon he/she can adjust incorrect labels. The system is retrained continuously, taking the corrections and approvals of the user into account. In this way, the system learns to make a better distinction between lung tissue and nonlung tissue. When using the interactive framework without supervised learning, the user corrects all incorrectly labeled VOIs manually. Both interactive segmentation tools were tested on 32 volumetric CT scans of pigs, mice and humans, containing pulmonary abnormalities. Results: On average, supervised interactive lung segmentation took under 9 min of user interaction. Algorithm computing time was 2 min on average, but can easily be reduced. On average, 2.0% of all VOIs in a scan had to be relabeled. Lung segmentation using the interactive segmentation method took on average 13 min and involved relabeling 3.0% of all VOIs on average. The resulting segmentations correspond well to manual delineations of eight axial slices per scan, with an average Dice similarity coefficient of 0.933. Conclusions: The authors have developed two fast and reliable methods for interactive lung segmentation in challenging chest CT images. Both systems do not require prior knowledge of the scans under consideration and work on a variety of scans.
Patterns of Gene Content and Co-occurrence Constrain the Evolutionary Path toward Animal Association in Candidate Phyla Radiation Bacteria
Studying the genetic differences between related microorganisms from different environment types can indicate factors associated with their movement among habitats. This is particularly interesting for bacteria from the Candidate Phyla Radiation because their minimal metabolic capabilities require associations with microbial hosts.
Poultry Building Smart Control Technologies for Energy Efficiency and Animal Welfare
Explore the source record for details and available documents.
Cavemen Animations for Nuclear Weapons Exhibit: Templates for VISIBLE Team
We use a couple of cavemen to explain the concept of deterrence, which has been with humans from the beginning. The interaction between the two cavemen will demonstrate how deterrence can discourage violence by instilling doubt and fear of the consequences escalating such violence further.
Reburning of Animal Waste Based Biomass with Coal for NO x Reduction, Part I: Feedlot Biomass (FB) and Coal:FB Blends
Cattle biomass (CB or manure from cattle) is proposed as reburn fuel under slightly fuel-rich conditions. The CB includes wastes from cattle feedlots (cattle grown in feedlots to slaughter weights of 450–640 kg) termed as Feedlot Biomass (FB) and cattle wastes from dairy farms termed as Dairy Biomass (DB). NOx emissions from coal-fired power plants can be reduced by using pure CB and Coal:CB mixtures as reburn fuels (10~30% by heat) injected after the primary combustion region. Experiments with Coal:CB mixtures as reburn fuels were performed using the 30 kW burner facility. Part I deals with results from experiments using pure FB and Coal:FB blends as reburn fuels while Part II presents results on extent of NOx reduction using pure DB and Coal:DB blends as reburn fuels (RF). In the current work, results on NOx emission are presented with FB and Coal:FB blends as RF. The parametric studies include: equivalence ratio in reburn zone (ERRBZ), vitiated air, angle of reburn nozzles, presence and absence of heat exchangers (HEXs), and baseline NOx concentration. The optimum operating conditions for FB reburning were found to be conditions with vitiation at ERRBZ = 1.1 with 45° upward counter-current injection in the presence of HEXs. NOx emissions were reduced by as much as 96%.
Experimental animal decompressions to less than 2 mm. hg absolute - pathologic effects.
Pathological effects of rapid decompression in experimental dogs, examining tissues and lung damage
Survival of animals in magnetic fields of 140,000 oe.
Biological effects of 100,000 oe magnetic fields on mice, drosophila and sea urchin eggs, particularly survival and genetic effects
Pathological changes in the lungs of animals under the influence of high oxygen pressures
Pathological characteristics and mechanism of pulmonary involvement in high pressure oxygen toxicity in guinea pigs and dogs
Changes in the electrical activity of the hearts of animals under the influence of high oxygen pressure
Heart activity during high pressure oxygen toxicity in dogs and guinea pigs