At least 541 records · Page 30

Collective Analysis of Alpha Particle Losses Due to Self-Absorption by Mass Loading on Radioactive Particulate Glass Fiber Filters

In this study, we derived a relationship between filter mass loading and the percent loss during analysis using the mass loading data collected from six previous studies of self-absorption. Components of mass loading include particulate dust, radioactive particulates, and filter material. In a research report published in 1984, Higby calculated a minimum burial depth for an alpha particle to be lost due to absorption (100% loss) of about 3.7 mg/cm 2 based on calculations for the range of 239-Pu alpha particles in glass fiber filters. From there, Higby concluded that a correction factor of 0.85 assumes approximately 15% losses in the count rate of both alpha and beta particles. In 2000, Luetzelschwab et al. recommended assuming a 40% loss at a loading of 3.3 mg/cm 2 and a 28% loss for a loading of 2.3 mg/cm 2 which included the frontal face mass of the filter. More recently, the 100% losses due to absorption were reported to be in the 10 mg/cm 2 range. Presented here is a trinomial relationship method of relating percent loss due to self-absorption to filter mass loading, based on data reported by Higby, Luetzelschwab et al., Huang et al., Barnett et al., Smith et al., and Hogue et al. Under normal operating conditions at the stacks monitored by Effluent Management, the mass loading of sample filters averages 0.09 ± 0.12 (2s) mg/cm 2 (excluding negative values and outliers) and ranges from 0 mg/cm 2 to 0.24 mg/cm 2 . Based on current mass loading results for Effluent Management stack sample filters, the forced-zero trinomial relationship method estimated self-absorption losses of less than 5%. Because American National Standards Institute/Health Physics Society N13.1-2011 guidelines indicate a correction factor should be used when the penetration of radioactive material into the collection media or self-absorption of radiation by the material collected would reduce the count rate by more than 5%, it is possible continued application of a correction factor to the Effluent Management stack samples is no longer necessary. Nevertheless, continuing to assign a correction factor at the 5% threshold (i.e., 0.95) would be a conservative approach.

36 MATERIALS SCIENCE↗

Effect of oxygen annealing on the multiferroic properties of Ca{sup 2+} doped BiFeO{sub 3} nanoceramics

The high leakage current in divalent ion doped BiFeO{sub 3} systems is limiting their large scale application. It is clearly shown that the methodology of oxygen annealing will prove to be an effective procedure for suppressing the detrimental consequences that originate from the oxygen vacancies. The samples annealed under oxygen also show different particle morphologies and packing density that can help in tuning the relevant physical properties, viz., magnetic, ferroelectric, and magnetoelectric. The difference in magnetic behaviour in samples annealed in air and oxygen can be explained in terms of the modification in the Fe-O-Fe bonds, domain wall pinning centres, and crystal anisotropy. Another important observation is the stabilization of a dielectric anomaly near the magnetic transition temperature. This observation can make this multiferroic system very interesting for application in sensors where the change in the magnetic parameters can be observed by monitoring the electrical parameters. Detailed analysis of the dielectric and impedance curves indicate towards the presence of non-Debye type processes in samples obtained by annealing in air or oxygen. From the calculated activation energy values, the vacancy related relaxation mechanism is predominant in air annealed samples, while the oxygen annealed samples show the presence of two type of relaxation processes, viz., electron hopping mechanism stabilizes at low temperature while, at higher temperatures, the process associated with the diffusion of doubly ionized oxygen ions predominates. The ac-conductivity data suggests that the correlated barrier tunnelling mechanism, where single electron or two electrons hopping through neighbouring lattice sites leads to ac-conduction.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Filtration Performance Results: Sierra Peaks Material No. 4

Sandia National Laboratories (SNL) assessed the filtration performance of materials from Sierra Peaks to identify alternatives which may perform similarly to materials used in FDA-approved N95 respirators. This work is meant to characterize the aerosol performance of materials to give Sierra Peaks information for them to determine if they elect to submit masks made using these materials for follow-on N95 certification testing at an accredited facility. The R&D testbed used is a large-scale filtration system designed to test commercial filter boxes. System modifications were performed to simulate, where possible, parameters defined by the National Institute for Occupational Safety and Health (NIOSH) for certification of filter materials for N95 respirators (NIOSH 2019). The system is a pull-through design. Air enters through a Laminar Flow Element (LFE) and the volumetric flow is measured based on the pressure drop across the LFE. Pressure is measured via a Pressure Transducer (PT). The air then passes through a High Efficiency Particulate Air (HEPA) filter to purge the air of ambient airborne particulates. Test aerosol is injected into the flow shortly after and mixing is induced via a coarse mesh. The airflow is allowed to fully develop prior to arriving at the test section. The aerosol then passes through the test material mounted in a box in the test section. Pressure drop across the test article is measured and aerosol sampling probes measure the aerosol concentrations upstream and downstream of the sample. The air passes through a second HEPA filter prior to being exhausted to ambient by a blower. A Topas aerosol generator is used to produce the test aerosol from Sodium Chloride (NaC1) dissolved in deionized (DI) water. Generated aerosol passes through a heated mixing chamber and a desiccant dryer to produce nanosized solid-state particulates. A dilution loop allows for the aerosol concentration to be regulated. The aerosol sampling probes upstream and downstream of the test section are aligned with the flow path. These are ducted directly to the aerosol sizing and counting instruments. A Laser Aerosol Spectrometer (LAS) was used for data collection in the original configuration of the system and was also used for initial testing in this project. Because the lower measurement range for the LAS is 90 nanometers (nm), the LAS was switched out for a more complicated Scanning Mobility Particle Sizer (SMPS) spectrometer system. The SMPS is comprised of an Electrostatic Classifier (EC), Differential Mobility Analyzer (DMA), and a Condensation Particle Counter (CPC). This enabled data collection at 75 nm, the particle size called out in the NIOSH guidelines.

36 MATERIALS SCIENCE↗

The Response of ClO Radical Concentrations to Variations in NO2 Radical Concentrations in the Lower Stratosphere

The response of ClO concentrations to changes in NO2 concentrations has been inferred from simultaneous observations of [ClO], [NO], [NO2] and [O3] in the mid-latitude lower stratosphere. This analysis demonstrates that [ClO] is inversely correlated with [NO2], consistent with formation and photolysis of [ClONO2]. A factor of ten range in the concentration of NO2 was sampled (0.1 to 1 x 10(exp 9) mol/cc), with a comparable range in the ratio of [ClO] to total available inorganic chlorine (1% <= [ClO]/[Cl(sub y)] <= 5%). This analysis leads to an estimate of [ClONO2]/[Cl(sub y)] = 0.12 (x/divided by 2), in the mid-latitude, lower-stratospheric air masses sampled.

Stimpfle, R. M.↗

Reactive Nitrogen and its Correlation with O3 and CO Over the Pacific in Winter and Early Spring

Measurements of NO, NO(y), O3, and CO were made during NASA's Global Tropospheric Experiment/Pacific Exploratory Mission-West B (GTE/PEM-West B) carried out over the western Pacific in February and March 1994. NO(x) was calculated from NO using a photostationary state model ((NO(x)(sub mc)). Correlations between these species are presented, and some insights into the sources of NO(x) and NO(y) are described. The boundaries between the lower, middle, and upper troposphere have been defined at potential temperatures of 311 K and 328 K, which correspond to the geometric altitudes of about 5 and 9 km at 30degN. Enhancements in the mixing ratios of NO(y) and CO were observed in the lower and middle troposphere. A positive correlation was found between these two species suggesting that the high NO(y) values were due to anthropogenic emissions over the continental surface. On the other hand, O3 increased little with increase in CO. As a result, NO(y)/O3 ratios were higher in air more influenced by pollution. NO(y), values in 55 and 28% of the air masses sampled in the lower and middle troposphere, respectively, were higher than the clean free tropospheric NO(y)-O3 range when O3 values simultaneously observed were used. High (NOx)mc/NOy ratios between 0.15 and 0.3 were found in the boundary layer with relatively low mixing ratios of CO and NOy during the three flights. These air masses were transported from a higher altitude (approximately 5 km) and a higher latitude (approximately 50degN) within a few days. The peroxyacetyl nitrate (PAN)/NO(y) ratios were generally high (approximately 0.4) in these air masses, and the thermal decomposition of PAN was a probable source of NO(x). In the middle troposphere the (NO(x))mc mixing ratio did not generally increase with NO(y) or CO, suggesting that the transport of air masses affected by anthropogenic emissions did not increase the NO(x) level significantly. In the upper troposphere, very minor effects from the continental surface sources were seen in the CO mixing ratio. By contrast, NO(y) values in 33% of the air masses were higher than those expected when stratospheric air intrusion is assumed to be a single source of NO(y) based on NO(y)-O3 correlation analyses. This result suggests significant free tropospheric NO(y) sources, namely exhaust from the aircraft and NO production by lightning activity. In fact, spikes in the (NO(x))(sub m)c mixing ratios were observed near the aircraft corridor south of Tokyo at an altitude of 10 km. These two free tropospheric NO(x) sources were considered to be important in determining the levels of the upper tropospheric NO(x) and NO(y) during PEM-West B.

Koike, M.↗

The determination of the global average OH concentration using a deuteroethane tracer

It is proposed to measure the decreasing global concentration of an OH reactive isotopic tracer, G sub 2 D sub 6, after its introduction into the troposphere in a manner to facilitate uniform global mixing. Analyses at the level of 2 x 10 to the -19th power fraction, corresponding to one kg uniformly distributed globally, should be possible by a combination of cryogenic absorption techniques to separate ethane from air and high sensitivity isotopic analysis of ethane by mass spectrometry. Aliquots of C sub 2 D sub 6 totaling one kg would be introduced to numerous southern and northern latitudes over a 10 day period in order to achieve a uniform global concentration within 3 to 6 months by the normal atmospheric circulation. Then samples of air of 1000 l (STP) would be collected periodically at a tropical and temperate zone location in each hemisphere and spiked with a known amount of another isotopic species of ethane, C-13 sub 2 H sub 6, at the level of 10 to the -11th power mole fraction. After separation of the ethanes from air, the absolute concentration of C sub 2 D sub 6 would be analyzed using the Argonne 100-inch radius mass spectrometer.

Stevens, Charles M.↗

The response of C1O radical concentrations to variations in NO2 radical concentrations in the lower stratosphere

The respose of ClO concentrations to changes in NO2 concentrations has been inferred from simultaneous observations of (ClO), (NO), (NO2) and (O3) in the midlatitude lower stratosphere. This analysis demonstrates that (ClO) is inversely correlated with (NO2), consistent with formation and photolysis of (ClONO2). A factor of ten range in the concentration if NO2 was sampled (0.1 to 1 x 10(exp 9) mol/cu cm), with a comparable range in the ratio of (ClO) to total available inorganic chlorine (1% less than or equal to (ClO)/(Cl(sub y)) less than or equal to 5%. This analysis leads to an estimate of (ClONO2)/(Cl(sub y)) = 0.12 (x/2), in the mid-latitude, lower-stratospheric air masses sampled.

Stimfle, R. M.↗

Enhancement of acoustical performance of hollow tube sound absorber

This paper presents acoustical performance of hollow structures utilizing the recycled lollipop sticks as acoustic absorbers. The hollow cross section of the structures is arranged facing the sound incidence. The effects of different length of the sticks and air gap on the acoustical performance are studied. The absorption coefficient was measured using impedance tube method. Here it is found that improvement on the sound absorption performance is achieved by introducing natural kapok fiber inserted into the void between the hollow structures. Results reveal that by inserting the kapok fibers, both the absorption bandwidth and the absorption coefficient increase. For test sample backed by a rigid surface, best performance of sound absorption is obtained for fibers inserted at the front and back sides of the absorber. And for the case of test sample with air gap, this is achieved for fibers introduced only at the back side of the absorber.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Faster Array Training and Rapid Analysis for a Sensor Array Intended for an Event Monitor in Air

Environmental monitoring, in particular, air monitoring, is a critical need for human space flight. Both monitoring and life support systems have needs for closed loop process feedback and quality control for environmental factors. Monitoring protects the air environment and water supply for the astronaut crew and different sensors help ensure that the habitat falls within acceptable limits, and that the life support system is functioning properly and efficiently. The longer the flight duration and the farther the destination, the more critical it becomes to have carefully monitored and automated control systems for life support. There is an acknowledged need for an event monitor which samples the air continuously and provides near real-time information on changes in the air. Past experiments with the JPL ENose have demonstrated a lifetime of the sensor array, with the software, of around 18 months. We are working on a sensor array and new algorithms that will incorporate transient sensor responses in the analysis. Preliminary work has already showed more rapid quantification and identification of analytes and the potential for faster training time of the array. We will look at some of the factors that contribute to demonstrating faster training time for the array. Faster training will decrease the integrated sensor exposure to training analytes, which will also help extend sensor lifetime.

sensing array↗

Performance of methods for SARS-CoV-2 variant detection and abundance estimation within mixed population samples

The accurate identification of SARS-CoV-2 (SC2) variants and estimation of their abundance in mixed population samples (e.g., air or wastewater) is imperative for successful surveillance of community level trends. Assessing the performance of SC2 variant composition estimators (VCEs) should improve our confidence in public health decision making. Here, we introduce a linear regression based VCE and compare its performance to four other VCEs: two re-purposed DNA sequence read classifiers (Kallisto and Kraken2), a maximum-likelihood based method (Lineage deComposition for Sars-Cov-2 pooled samples (LCS)), and a regression based method (Freyja). We simulated DNA sequence datasets of known variant composition from both Illumina and Oxford Nanopore Technologies (ONT) platforms and assessed the performance of each VCE. We also evaluated VCEs performance using publicly available empirical wastewater samples collected for SC2 surveillance efforts. Bioinformatic analyses were performed with a custom NextFlow workflow (C-WAP, CFSAN Wastewater Analysis Pipeline). Relative root mean squared error (RRMSE) was used as a measure of performance with respect to the known abundance and concordance correlation coefficient (CCC) was used to measure agreement between pairs of estimators. Based on our results from simulated data, Kallisto was the most accurate estimator as it had the lowest RRMSE, followed by Freyja. Kallisto and Freyja had the most similar predictions, reflected by the highest CCC metrics. We also found that accuracy was platform and amplicon panel dependent. For example, the accuracy of Freyja was significantly higher with Illumina data compared to ONT data; performance of Kallisto was best with ARTICv4. However, when analyzing empirical data there was poor agreement among methods and variations in the number of variants detected (e.g., Freyja ARTICv4 had a mean of 2.2 variants while Kallisto ARTICv4 had a mean of 10.1 variants). This work provides an understanding of the differences in performance of a number of VCEs and how accurate they are in capturing the relative abundance of SC2 variants within a mixed sample (e.g., wastewater). Such information should help officials gauge the confidence they can have in such data for informing public health decisions.

60 APPLIED LIFE SCIENCES↗

Europa Propulsion Valve Seat Material Testing

The Europa mission and spacecraft design presented unique challenges for selection of valve seat materials that met the fluid compatibility requirements, and combined fluid compatibility and high radiation exposure level requirements. The Europa spacecraft pressurization system valves will be exposed to fully saturated propellant vapor for the duration of the mission. The effects of Nitrogen Tetroxide (NTO) and Monomethylhydrazine (MMH) propellant vapors on heritage valve seat materials, such as Vespel SP-1 and Polychlorotrifluoroethylene (PCTFE), were evaluated to determine if an alternate material is required. In liquid system applications, Teflon is the only available compatible valve seat material. Radiation exposure data for Teflon in an air or vacuum environment has been previously documented. Radiation exposure data for Teflon in an oxidizer environment such as NTO, was not available, and it was unknown whether the effects would be similar to those on air-exposed samples. Material testing was conducted by Marshall Space Flight Center (MSFC) and White Sands Test Facility (WSTF) to determine the effects of propellant vapor on heritage seat materials for pressurization valve applications, and the effects of combined radiation and NTO propellant exposure on Teflon. The results indicated that changes in heritage pressurization valve seat materials' properties rendered them unsuitable for the Europa application. The combined radiation and NTO exposure testing of Teflon produced results equivalent to combined radiation and air exposure results.

Addona, Brad M.↗

Continued Environmental Microbiology Monitoring of the International Space Station (ISS) Veggie Unit Used for In-Flight, Crop-Based Food Systems

Crewmembers live and work in a closed environment that is monitored to ensure their health and safety. To ensure occupants’ health and safety during their spaceflight residency, Environmental Health System (EHS) microbial samples including air, surface, and water, are collected, enumerated, and analyzed quarterly to monitor on-board system contamination and potential risks to crew health. Quarterly monitoring of the microorganisms in the ISS environment supports crew safety and contributes to a large set of microbial concentration and diversity data. Based upon data historically collected over the years, in-flight microbial requirements have been established to maintain the health and safety of the spacecraft environment. This study leverages quarterly operational Environmental Health System (EHS) sampling by collecting additional microbial samples from the surface of the station’s Veggie plant production system. Microbial surface samples collected from the Veggie plant production system will yield microbial concentration and diversity that can be compared and analyzed with nominal surface samples from the vehicle. The data collected in this study will aid in the development of requirements for spaceflight-based food production systems. Continued surface sampling of the internal and external surfaces of the Veggie locker, along with collaboration from both Johnson Space Center (JSC) & Kennedy Space Center (KSC) scientists studying the microbiome of the veggie-crop systems, will be implemented as part of the future development of crop-based food system requirements for the ISS and beyond. This presentation will include a review of the study procedures and evaluations of the current results.

Christian Mena↗

Microbiology and Crew Medical Events on the International Space Station

The closed environment of the International Space Station (ISS) creates an ideal environment for microbial growth. Previous studies have identified the ubiquitous nature of microorganisms throughout the space station environment. To ensure safety of the crew, microbial monitoring of air and surface within ISS began in December 2000 and continues to be monitored on a quarterly basis. Water monitoring began in 2009 when the potable water dispenser was installed on ISS. However, it is unknown if high microbial counts are associated with inflight medical events. The microbial counts are determined for the air, surface, and water samples collected during flight operations and samples are returned to the Microbiology laboratory at the Johnson Space Center for identification. Instances of microbial counts above the established microbial limit requirements were noted and compared inflight medical events (any non-injury event such as illness, rashes, etc.) that were reported during the same calendar-quarter. Data were analyzed using repeated measures logistic regression for the forty-one US astronauts flew on ISS between 2000 and 2012. In that time frame, instances of microbial counts being above established limits were found for 10 times for air samples, 22 times for surface samples and twice for water. Seventy-eight inflight medical events were reported among the astronauts. A three times greater risk of a medical event was found when microbial samples were found to be high (OR = 3.01; p =.007). Engineering controls, crew training, and strict microbial limits have been established to mitigate the crew medical events and environmental risks. Due to the timing issues of sampling and the samples return to earth, identification of particular microorganisms causing a particular inflight medical event is difficult. Further analyses are underway.

Oubre, Cherie↗

Microbiology and Crew Medical Events on the International Space Station

The closed environment of the International Space Station (ISS) creates an ideal environment for microbial growth. Previous studies have identified the ubiquitous nature of microorganisms throughout the space station environment. To ensure safety of the crew, microbial monitoring of air and surface within ISS began in December 2000 and continues to be monitored on a quarterly basis. Water monitoring began in 2009 when the potable water dispenser was installed on ISS. However, it is unknown if high microbial counts are associated with inflight medical events. The microbial counts are determined for the air, surface, and water samples collected during flight operations and samples are returned to the Microbiology laboratory at the Johnson Space Center for identification. Instances of microbial counts above the established microbial limit requirements were noted and compared inflight medical events (any non-injury event such as illness, rashes, etc.) that were reported during the same calendar-quarter. Data were analyzed using repeated measures logistic regression for the forty-one US astronauts flew on ISS between 2000 and 2012. In that time frame, instances of microbial counts being above established limits were found for 10 times for air samples, 22 times for surface samples and twice for water. Seventy-eight inflight medical events were reported among the astronauts. A three times greater risk of a medical event was found when microbial samples were found to be high (OR = 3.01; p =.007). Engineering controls, crew training, and strict microbial limits have been established to mitigate the crew medical events and environmental risks. Due to the timing issues of sampling and the samples return to earth, identification of particular microorganisms causing a particular inflight medical event is difficult. Further analyses are underway.

Oubre, Cherie M.↗

Implications of Sea Breeze Circulations on boundary layer aerosols in the southern coastal Texas region

The Sea Breeze Circulation (SBC) influences atmospheric processes at multiple scales in coastal regions. Understanding how SBCs impact the aerosol number budget and aerosol–cloud interaction processes is essential. This study investigates sea breeze–aerosol interactions (SAIs) during 46 summertime SBC events using data from the TRacking Aerosol Convection Interactions Experiment (TRACER) field campaign across urban (main) and rural (supplemental) coastal sites in southern Texas. Weather Research and Forecasting model coupled with Chemistry (WRF-Chem) simulations complement observations to explore spatio-temporal meteorological controls on boundary layer aerosols. During the summertime, Sea Breeze Fronts (SBF) penetrating inland transported cool, moist air over the land, introducing air masses with distinct properties compared to the preexisting continental air. These SAIs cause variability in number concentrations of up to a factor of two, with events typically lasting ∼ 5 h before returning to background conditions. SAI impact on aerosols varies with site proximity to water and the preceding sea breeze (SB) history, primarily affecting the marine-influenced accumulation mode. The main site, influenced by both Galveston Bay and the Gulf of Mexico, reflects a stronger marine influence. In contrast, a supplemental site, at a similar shoreline distance but exposed only to the Gulf of Mexico and typically upstream of the urban core, samples SB air that has traversed land and partially regained continental characteristics. Simulations show that the regional SAIs extend ∼ 50 km inland and reach up to the boundary layer height. SAIs further decrease cloud condensation nuclei relevant aerosol number concentrations in ∼ 20 % of events during SBF passage.

54 ENVIRONMENTAL SCIENCES↗

Assessment of NO2 Observations During DISCOVER-AQ and KORUS-AQ Field Campaigns

NASA’s Deriving Information on Surface Conditions from Column and Vertically Resolved Observations Relevant to Air Quality (DISCOVER-AQ, conducted in 2011–2014) campaign in the United States and the joint NASA and National Institute of Environmental Research (NIER) Korea–United States Air Quality Study (KORUS-AQ, conducted in 2016) in South Korea were two field study programs that provided comprehensive, integrated data sets of airborne and surface observations of atmospheric constituents, including nitrogen dioxide (NO2), with the goal of improving the interpretation of spaceborne remote sensing data. Various types of NO2 measurements were made, including in situ concentrations and column amounts of NO2 using ground- and aircraft-based instruments, while NO2 column amounts were being derived from the Ozone Monitoring Instrument (OMI) on the Aura satellite. This study takes advantage of these unique datasets by first evaluating in situ data taken from two different instruments on the same aircraft platform, comparing coincidently sampled profile-integrated columns from aircraft spirals with remotely sensed column observations from ground-based Pandora spectrometers, intercomparing column observations from the ground (Pandora), aircraft (in situ vertical spirals), and space (OMI), and evaluating NO2 simulations from coarse Global Modeling Initiative (GMI) and high-resolution regional models. We then use these data to interpret observed discrepancies due to differences in sampling and deficiencies in the data reduction process. Finally, we assess satellite retrieval sensitivity to observed and modeled a priori NO2 profiles. Contemporaneous measurements from two aircraft instruments that likely sample similar air masses generally agree very well but are also found to differ in integrated columns by up to 31.9 %. These show even larger differences with Pandora, reaching up to 53.9 %, potentially due to a combination of strong gradients in NO2 fields that could be missed by aircraft spirals and errors in the Pandora retrievals. OMI NO2 values are about a actor of 2 lower in these highly polluted environments due in part to inaccurate retrieval assumptions (e.g., a priori pro-files) but mostly to OMI’s large footprint (>312 km2).

Nitrogen dioxide↗

Ultra-low-level measurements of airborne fission products from the Fukushima Daiichi reactor accident using high volume collection systems at Savannah River National Laboratory

For this study, ultra-low-level measurements of radionuclides in air have been conducted at the Savannah River National Laboratory (SRNL) to determine the atmospheric concentration of fission products released following the Fukushima Daiichi reactor accident on March 11, 2011. Air filter samples were acquired from two high-volume collection systems (a traditional filter-based system and an electrostatic precipitator-based system) to monitor airborne radionuclide concentrations in the period covering from 2 weeks to 3 years after the disaster. The world-wide spread of low-level concentrations of airborne fission products from the Fukushima event provided a unique opportunity to demonstrate SRNL's electrostatic particle collection technology and other improvements in environmental monitoring developed at the Savannah River Site (SRS). Detecting and analyzing the release allowed a comprehensive test of SRS systems for monitoring environmental radioactivity. Gamma-ray-emitting fission products ( 131,132 I, 134,136,137 Cs, and 129,132 Te) and cosmogenic isotopes ( 7 Be and 22 Na) in air were detected and quantified by high-resolution gamma-ray spectroscopy at concentrations as low as 0.07 μBq per standard cubic meter (SCM) (50 mBq total 137 Cs), while plutonium content was quantified by thermal ionization mass spectrometry (TIMS) at concentrations as low as 6.5 × 10 –21 g/SCM (3.0 fg 239+240 Pu). Isotope concentrations measured at SRNL from gamma-ray spectroscopy were compared to independent measurements from Chapel Hill, NC, located approximately 370 km (230 mi) NE of SRNL. Meteorological modeling was also used to predict radionuclide transport from the location of release to both measurement locations.

63 RADIATION, THERMAL, AND OTHER ENVIRON. POLLUTAN↗

Process intensification approach to enhancing heat and mass transfer: Radio frequency (RF) assisted drying of paper and board

Conventional multi-cylinder drying of paper and board typically relies on both conductive drying from steam-heated cylinders and convective drying, where heated air flows over the paper web surface. Conduction primarily contributes to heat transfer, while convection is the main driver of mass transfer. However, conventional drying systems are heavily dependent on steam, usually powered by fossil fuels, and are often energy-inefficient with high levels of waste. Additionally, these surface-driven processes result in a lower percentage of energy absorption compared to the energy supplied, leading to significant energy losses. To improve this long-standing process, an experimental system was developed to investigate a process intensification approach involving the integration of Radio Frequency (RF) heating, a volumetric electromagnetic technology, alongside traditional conduction and convection drying methods. This study also emphasizes the use of sensors to continuously monitor key parameters such as moisture content, supply system temperatures, sample temperatures, air flows, and drying rates in real-time. The effect of RF as an auxiliary energy source in localized environments at varying moisture levels was explored to optimize industrial drying systems, quantify potential improvements, and provide insights for future studies. Experimental results from trials combining RF with convection and with the base case alternating conduction-convection drying processes are presented. It is shown that RF is a viable process intensification approach for paper drying improving the drying rate and energy intensity at higher moisture contents. These findings offer valuable insights for process intensification and contribute to the process development, modeling, and simulation of advanced paper drying techniques.

42 ENGINEERING↗