SEARCH · Engineering Papers
Results for “Accelerators, Instrumentation”
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Tracking rare-isotope beams with microchannel plates
A system of two microchannel-plate detectors has been successfully implemented for tracking projectile-fragmentation beams. The detectors provide interaction positions, angles, and arrival Limes of ions at the reaction target. Furthermore, the current design is an adaptation of an assembly used for low-energy beams (~1.4 MeV/nucleon). In order to improve resolution in tracking high-energy heavy-ion beams, the magnetic field strength between the secondary-electron accelerating foil and the microchannel plate had to be increased substantially. Results from an experiment using a 37-MeV/nucleon 56 Ni beam show that the tracking system can achieve sub-nanosecond timing resolution and a position resolution of ~1 mm for beam intensities up to 5 x 10 5 pps.
Beam position reconstruction for the g2p experiment in Hall A at Jefferson Lab
Beam-line equipment was upgraded for experiment E08-027 (g2p) in Hall A at Jefferson Lab. Two beam position monitors (BPMs) were necessary to measure the beam position and angle at the target. A new BPM receiver was designed and built to handle the low beam currents (50-100 nA) used for this experiment. Two new super-harps were installed for calibrating the BPMs. In addition to the existing fast raster system, a slow raster system was installed. We found that before and during the experiment, these new devices were tested and debugged, and their performance was also evaluated. In order to achieve the required accuracy (1-2 mm in position and 1-2 mrad in angle at the target location), the data of the BPMs and harps were carefully analyzed, as well as reconstructing the beam position and angle event by event at the target location. Finally, the calculated beam position will be used in the data analysis to accurately determine the kinematics for each event.
Laser and optical system for laser assisted hydrogen ion beam stripping at SNS
A high-efficiency laser assisted hydrogen ion (H-) beam stripping was recently successfully carried out in the Spallation Neutron Source (SNS) accelerator. The experiment was not only an important step toward foil-less H- stripping for charge exchange injection, it also set up a first example of using megawatt ultraviolet (UV) laser source in an operational high power proton accelerator facility. This study reports in detail the design, installation, and commissioning result of a macro-pulsed multi-megawatt UV laser system and laser beam transport line for the laser stripping experiment.
Beam test results of a 16 ps timing system based on ultra-fast silicon detectors
Not Available
The ALICE Transition Radiation Detector: Construction, operation, and performance
The Transition Radiation Detector (TRD) was designed and built to enhance the capabilities of the ALICE detector at the Large Hadron Collider (LHC). While aimed at providing electron identification and triggering, the TRD also contributes significantly to the track reconstruction and calibration in the central barrel of ALICE. In this article, the design, construction, operation, and performance of this detector are discussed. A pion rejection factor of up to 410 is achieved at a momentum of 1 GeV/c in p-Pb collisions and the resolution at high transverse momentum improves by about 40% when including the TRD information in track reconstruction. The triggering capability is demonstrated both for jet, light nuclei, and electron selection.
Optical design for increased interaction length in a high gradient dielectric laser accelerator
Not Available
The fast non-ferric kicker system for the Muon g–2 Experiment at Fermilab
Here we describe the installation, commissioning, and characterization of the new injection kicker system in the Muon g – 2 Experiment (E989) at Fermilab, which makes a precision measurement of the muon magnetic anomaly. Three Blumlein pulsers drive each of the 1.27-m-long non-ferric kicker magnets, which reside in a storage ring vacuum (SRV) that is subjected to a 1.45 T magnetic field. The new system has been redesigned relative to Muon g – 2 ’s predecessor experiment, and we present those details in this manuscript.
Optically pumped polarized 3 He ++ ion source development for RHIC/EIC
The proposed polarized 3 He ++ acceleration in RHIC and the future Electron-Ion Collider will require about 2×10 11 ions in the source pulse. A new technique had been proposed for production of high intensity polarized 3 He ++ ion beams. It is based on ionization and accumulation of the 3 He gas (polarized by metastability-exchange optical pumping and in the 5T high magnetic field) in the existing Electron Beam Ion Source (EBIS). A novel 3 He cryogenic purification and storage technique was developed to provide the required gas purity. An original gas refill and polarized 3 He gas injection to the EBIS long drift tubes, (which serves as the storage cell) were developed to ensure polarization preservation. An infrared laser system for optical pumping and polarization measurements in the high 3–5 T field has been developed. The 3 He polarization 80–85% (and sufficiently long ~30 min relaxation time) was obtained in the “open” cell configuration with refilling valve tube inlet and isolation valve closed. The development of the spin-rotator and 3 He 4 He absolute nuclear polarimeter at 6 MeV 3 He ++ beam energy is also presented here in this work.
Characterization of 4H-SiC Low Gain Avalanche Detectors (LGADs)
4H-SiC Low Gain Avalanche Detectors (LGADs) have been fabricated and characterized. The devices employ a circular mesa design with low-resistivity contacts and an SiO 2 passivation layer. The I–V and C–V characteristics of the 4H-SiC LGADs are compared with complementary 4H-SiC PiN diodes to confirm a high breakdown voltage and low leakage current. Both LGADs and PiN diodes were irradiated with alpha particles from a $^{210}_{84}$Po source. The charge collected by each device was compared, and it was observed that low-gain charge carrier multiplication is achieved in the 4H-SiC LGAD.
Detector development for Jefferson Lab's 12GeV Upgrade
Jefferson Lab will soon finish its highly anticipated 12 GeV Upgrade. With doubled maximum energy, Jefferson Lab’s Continuous Electron Beam Accelerator Facility (CEBAF) will enable a new experimental program with substantial discovery potential, addressing important topics in nuclear, hadronic and electroweak physics. In order to take full advantage of the high energy, high luminosity beam, new detectors are being developed, designed and constructed to fit the needs of different physics topics. The paper will give an overview of various new detector technologies to be used for 12 GeV experiments. It will then focus on the development of two solenoid-based spectrometers, the GlueX and SoLID spectrometers. The GlueX experiment in Hall D will study the complex properties of gluons through exotic hybrid meson spectroscopy. The GlueX spectrometer, a hermetic detector package designed for spectroscopy and the associated partial wave analysis, is currently in the final stage of construction. Hall A, on the other hand, is developing the SoLID spectrometer to capture the 3D image of the nucleon from semi-inclusive processes and to study the intrinsic properties of quarks through mirror symmetry breaking. Such a spectrometer will have the capability to handle very high event rates while still maintaining a large acceptance in the forward region.
Particle-in-cell techniques for the study of space charge effects in the Advanced Cryogenic Gas Stopper
The Facility for Rare Isotope Beams, FRIB, will significantly increase the rates and varieties of rare isotopes compared to those presently available at existing rare-isotope facilities. The production of stopped beams via the current generation of linear gas stopping devices available is not well matched to the beam intensities that will be available at FRIB. Many experiments that make use of reaccelerated beams, from the ReA facility, greatly benefit from having the highest-intensity, rare-isotope beams possible. Some experiments would also benefit greatly from stopped beams with improved purity. In this paper, the intensity bottlenecks of FRIB’s newest linear gas stopper are studied via experiment and simulation in support of a future detailed conceptual design of a next-generation linear gas stopper that can provide rare-isotope beams with rates of 10^8 pps, a factor of 50 higher than the current state-of-the-art system, with improved beam purity.
Finite element analysis of the impact of beam heating mode in molten salt corrosion experiments employing simultaneous ion irradiation
Finite element analysis was used to investigate the temperature and stress profiles that develop in 316L stainless steel membranes being irradiated using different proton beam conditions in contact with a molten salt environment. It was shown that in addition to a nonuniform irradiation profile, a focused 2 MeV proton beam leads to very strong temperature and stress gradients in the membrane, introducing highly localized driving forces that complicate and even compromise the integrity and reliability of the experimental results of corrosion studies. Here, the use of a focused beam in corrosion studies can create experimental artifacts that may misrepresent the true corrosion behavior. In contrast, the use of a rastered beam is shown to distribute the protons and resulting radiation damage uniformly across the membrane face, and more importantly, results in temperature and stress profiles that are not only very uniform but are of much lower magnitude. The use of a rastered beam during molten salt corrosion experiments is therefore recommended to achieve uniform damage rates, thereby reducing both gradients and magnitudes of the temperature and stress distributions.
A high-precision miniaturized rotating coil transducer for magnetic measurements
A miniaturized Printed Circuit Board (PCB) sensing coil, jointly developed by CERN and Fermilab for measuring the field of small-gap (less than 10 mm) accelerator magnets, is illustrated. A sensing coil array, with a scheme for compensating the main field when measuring the harmonic error components, hosted on a synthetic sapphire-based transducer, is presented. Key innovating features are (i) very-small size, both for the sensing coil array (thickness of 1.380 mm) and for the transducer (overall diameter of 7.350 mm), (ii) metrological performance, namely accuracy (more than five times better than state of the art), and 1-sigma repeatability (ten times better on harmonics with amplitude less than 100 ppm), and (iii) manufacturing technology of both the coil array (13 double layers aligned within 10 μm), and the sapphire support (concentricity, the most important uncertainty source for rotating coils, 3 μm of uncertainty, namely one order of magnitude better than fiberglass support). After stating the measurement problem, the design of the transducer and a case study of a two-layer PCB sensor array are also illustrated. Then, the prototyping and quality control of both the sensor and the transducer are discussed. Furthermore, the calibration and the results obtained with a prototype setup at Fermilab are presented. Finally, in the appendix, the theory of the rotating coil, the sensor geometry, and the harmonic compensation are briefly reviewed for the reader easiness.
A MHz-repetition-rate hard X-ray free-electron laser driven by a superconducting linear accelerator
The European XFEL is a hard X-ray free-electron laser (FEL) based on a high-electron-energy superconducting linear accelerator. The superconducting technology allows for the acceleration of many electron bunches within one radio-frequency pulse of the accelerating voltage and, in turn, for the generation of a large number of hard X-ray pulses. In this paper, we report on the performance of the European XFEL accelerator with up to 5,000 electron bunches per second and demonstrating a full energy of 17.5 GeV. Feedback mechanisms enable stabilization of the electron beam delivery at the FEL undulator in space and time. The measured FEL gain curve at 9.3 keV is in good agreement with predictions for saturated FEL radiation. Hard X-ray lasing was achieved between 7 keV and 14 keV with pulse energies of up to 2.0 mJ. Using the high repetition rate, an FEL beam with 6 W average power was created.
The need for reproducible research in soft robotics
In recent years we have witnessed the rise of commercialization efforts for soft robotic technology, including soft grippers (Soft Robotics, Inc.), stretchable sensors (StretchSense, Inc. and Lightlace, Inc.), and platforms for human-robot interaction (Festo Inc., Meta Reality Labs, Toyota Research Institute, and Disney Research). However, commercialization as a whole lags the trends enjoyed by other robotic technology at equivalent points in their respective lifecycles.
Measurements and analysis of bremsstrahlung x-ray spectrum obtained in NANOGAN electron cyclotron resonance ion source
From the ECR plasma, hot electrons leak across the magnetic lines of force and by striking the plasma chamber produce bremsstrahlung x-rays. The wall bremsstrahlung gives information on the confinement status of hot electron. In our studies, experimental measurements are carried out in NANOGAN electron cyclotron resonance (ECR) ion source for the wall bremsstrahlung x-rays and the results are presented. While optimizing a particular charge state in ECR ion source, experimental parameters are adjusted to get a maximum current. The wall bremsstrahlung components are studied in these cases for understanding the hot electron confinement conditions.
Observations of the frequency tuning effect in the 14 GHz CAPRICE ion source
A set of measurements with the CAPRICE ion source at the GSI test bench has been carried out to investigate its behavior in terms of intensity and shape of the extracted beam when the microwaves generating the plasma sweep in a narrow range of frequency ({+-}40 MHz) around the klystron center frequency (14.5 GHz). Remarkable variations have been observed depending on the source and the beamline operating parameters, confirming that a frequency dependent electromagnetic distribution is preserved even in the presence of plasma inside the source. Moreover, these observations confirm that the frequency tuning is a powerful method to optimize the electron cyclotron resonance ion source performances. A description of the experimental setup and of the obtained results is given in the following.