Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Ablation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 541 records · Page 30

Stereotactic Radiofrequency Ablation for Metastatic Melanoma to the Liver

PurposeTo evaluate the outcome of patients with melanoma liver metastasis treated with stereotactic radiofrequency ablation (SRFA).Material and MethodFollowing IRB approval, a retrospective evaluation of the treatment of 20 patients with 75 melanoma liver metastases was performed.ResultsA median number of 2 lesions (range 1–14) per patient with a median size of 1.7 cm (range 0.5–14.5 cm) were treated. 67 lesions were <3 cm (89.3 %) and 8 lesions were >3 cm (10.7 %). Per patient a median of 1 ablation session was performed (range: 1–4) totaling 34 sessions. There were no procedure-related deaths and all major complications (n = 3) could be easily treated by pleural drainages. The primary and secondary success rates were 89.3 and 93.3 %, respectively. The overall local recurrence rate was 13.3 %. Four of ten local recurrences were re-treated successfully by SRFA. During follow-up, 9/20 patients developed extrahepatic metastatic disease and 10/20 had liver recurrence at any location. The median OS from the date of SRFA was 19.3 months, with an OS of 64, 41, and 17 % at 1, 3, and 5 years, with no significant difference for patients with cutaneous and ocular melanoma. The median DFS after SRFA for all 20 patients was 9.5 months, with 37, 9, and 0 % at 1, 3, and 5 years.ConclusionsDue to the high local curative potential and the promising long-term survival rates associated with minimal morbidity and mortality, radiofrequency ablation seems to be an attractive alternative to resection in patients with melanoma liver metastases.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Image-Guided Spinal Ablation: A Review

The image-guided thermal ablation procedures can be used to treat a variety of benign and malignant spinal tumours. Small size osteoid osteoma can be treated with laser or radiofrequency. Larger tumours (osteoblastoma, aneurysmal bone cyst and metastasis) can be addressed with radiofrequency or cryoablation. Results on the literature of spinal microwave ablation are scarce, and thus it should be used with caution. A distinct advantage of cryoablation is the ability to monitor the ice-ball by intermittent CT or MRI. The different thermal insulation, temperature and electrophysiological monitoring techniques should be applied. Cautious pre-procedural planning and intermittent intra-procedural monitoring of the ablation zone can help reduce neural complications. Tumour histology, patient clinical-functional status and life-expectancy should define the most efficient and least disabling treatment option.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

RF Ablation of Giant Hemangiomas Inducing Acute Renal Failure: A Report of Two Cases

ObjectiveIn patients that require treatment for hepatic giant cavernous hemangiomas (GCH), radiofrequency ablation (RFA) has been suggested to represent a safe and effective alternative to invasive surgery. In a recent report of bipolar RFA, using two expandable needle electrodes, was uneventfully performed in patients with large GCH (>10 cm). The objective of this report is to present two cases in which bipolar RFA of symptomatic GCH was complicated by acute kidney injury.Materials and methodsIn 2015 we treated two patients for very large symptomatic GCH (15.7 and 25.0 cm) with bipolar RFA during open laparotomy.ResultsIn both patients the urine showed a red–brown discoloration directly after the ablation. They became anuric and presented with progressive dyspnea, tachypnea, and tachycardia, requiring hemodialysis for a period of 1 month in one case. Lab results revealed hemepigment-induced acute kidney. Both patients fully recovered and both showed a complete relief of symptoms at 3 months following the procedure.ConclusionRFA for large GCHs can cause hemepigment-induced acute kidney injury due to massive intravascular hemolysis. The presented cases suggest that caution is warranted and advocate an upper limit regarding the volume of GCHs that can be safely ablated.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Radiographic Local Tumor Control and Pain Palliation of Sarcoma Metastases within the Musculoskeletal System with Percutaneous Thermal Ablation

PurposeTo evaluate the effectiveness of percutaneous image-guided thermal ablation in achieving local tumor control and pain palliation of sarcoma metastases within the musculoskeletal system.Materials and MethodsRetrospective review of 64 sarcoma metastases within the musculoskeletal system in 26 women and 15 men (total = 41) treated with ablation between December 2011 and August 2016 was performed. Mean age of the cohort was 42.9 years ± 16.0 years. Two subgroups were treated: oligometastatic disease (n = 13) and widely metastatic disease (n = 51). A variety of sarcoma histologies were treated with average tumor volume of 42.5 cm{sup 3} (range 0.1–484.7 cm{sup 3}). Pain scores were recorded before and 4 weeks after therapy for 59% (38/64) of treated lesions. Follow-up imaging was evaluated for local control and to monitor sites of untreated disease as an internal control. Fifty-eight percent (37/64) were lost to imaging follow-up at varying time points over a year. Complication rate was 5% (3/64; one minor and two major events).ResultsOne-year local tumor control rates were 70% (19/27) in all patients, 67% (12/18) in the setting of progression of untreated metastases, and 100% (10/10) in the setting of oligometastatic disease. Median pain scores decreased from 8 (interquartile range 5.0–9.0) to 3 (interquartile range 0.1–4.0) 1 month after the procedure (P < 0.001).ConclusionImage-guided percutaneous ablation is an effective option for local tumor control and pain palliation of metastatic sarcomas within the musculoskeletal system. Treatment in the setting of oligometastatic disease offers potential for remission. Level of Evidence: Level 4, Retrospective Review.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Fusion Imaging and Virtual Navigation to Guide Percutaneous Thermal Ablation of Hepatocellular Carcinoma: A Review of the Literature

As medical imaging advancements have improved the detectability of hepatocellular carcinoma (HCC) in early stages, the approach to percutaneous thermal ablation for curative treatment has concomitantly advanced. Although many centers are adopting cross-sectional imaging to guide percutaneous ablation, the majority of procedures are still performed under ultrasound (US) guidance worldwide. Challenges to ultrasound guidance may present due to relatively poor resolution particularly with small or isoechoic lesions, or due to intervening structures such as the bowel or diaphragm that obstruct lesional visualization. Fusion imaging (FI) systems have been employed to address these challenges. By merging or synchronizing the real-time images from US with a previously obtained cross-sectional study, FI mitigates the inherent limitations of each individual imaging modality and expands procedural feasibility and technical outcomes. This manuscript reviews the current literature on the use of FI during percutaneous thermal ablation of HCC.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Microwave Ablation of Renal Cell Carcinoma of the Transplanted Kidney: Two Cases

Thermal ablative techniques have been increasingly recognized as a valuable alternative to graftectomy and nephron-sparing surgery for the treatment of small neoplasms arising in the transplanted kidney. However, long-term efficacy and safety data are still lacking. In particular, current experience with microwave ablation is limited to a very recent single-centre series of three cases. We herein report two microwave ablations of renal cell carcinoma of the kidney allograft. The procedures were successfully performed under ultrasound guidance with complete tumour necrosis, no peri-operative complications, and preserved renal function. No recurrences were observed after 3 years of follow-up.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Percutaneous Laser Ablation of Liver Metastases from Neuroendocrine Neoplasm. A Retrospective Study for Safety and Effectiveness

Purpose: To retrospectively assess safety and efficacy of laser ablation (LA) of multiple liver metastases (LM) from neuroendocrine neoplasms (NEN). Methods: Twenty-one patients with NEN and at least 3 LM ≤ 4 cm in diameter underwent ultrasonography-guided LA. Up to seven LM were ablated in a single session; if the number of LM exceeded seven, the remaining LM were ablated in further LA sessions with a time interval of 3–4 weeks. LA was performed according to the multifiber technique. The patients underwent contrast-enhanced CT 1 month after LA, and were subsequently monitored every 3 months for the first 2 years and then every 6 months. Results: In total, 189 LM were treated in 21 patients (mean 9 ± 8.2, median 6) in 41 LA sessions (range 1–5). The diameter of LM ranged from 5 to 35 mm (median 19 mm, mean 17.9 ± 6.4 mm). One grade 4 complication occurred (0.53%): a bowel perforation managed by surgery. Technical efficacy was 100%, primary efficacy rate 94.7%, and secondary efficacy rate 100%. Complete relief of hormone-related symptoms was obtained in all the 13 symptomatic patients. Median follow-up was 39 months (range 12–99). 1-, 2-, 3-, and 5-year survival rates were 95%, 86%, 66%, and 40%, respectively. Overall survival resulted higher for patients with Ki-67 expression ≤ 7% than for those with Ki-67 > 7% (p = 0.0347). Conclusions: LA is a promising and safe technique to treat LM from NEN. A longer follow-up should provide definitive information on the long-term efficacy of this liver-directed therapy. Level of Evidence: Retrospective study, local non-random sample, level 3.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Au, Ge and AuGe Nanoparticles Fabricated by Laser Ablation

A eutectic AuGe target immersed in distilled water was ablated by pulsed ultraviolet laser light. The structure of the ablated material was investigated by high-resolution transmission electron microscopy (HRTEM). The images show formation of nanowire structures of AuGe up to 100 nm in length, with widths of 5-10 nm. These nanostructures have Ge content significantly lower than the target material. Electron diffraction demonstrates that they crystallize in the {alpha}-AuGe structure. For comparison, laser ablation of pure Au and pure Ge targets was also performed under the same conditions. HRTEM shows that Ge forms spherical nanoparticles with a characteristic size of {approx}30 nm. Au forms spherical nanoparticles with diameters of {approx}10 nm. Similar to AuGe, it also forms chainlike structures with substantially lower aspect ratio.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Influence of the Solvent on the Structure and Morphology of Nanoparticles Fabricated by Laser Ablation of Bulk Magnesium Targets

Ultrafine powders and colloid solutions of nanoparticles are fabricated by nanosecond pulsed laser ablation (a Nd:YAG laser, 1064 nm, 7 ns, 150 mJ, and 20 Hz) of metallic magnesium targets in water and organic solvents of different polarities (ethyl alcohol, ethyl acetate, and n-hexane). The morphology, dimensional characteristics, composition, and structure of the particles are studied by the methods of transmission electron microscopy, x-ray diffraction, and Fourier-transform infrared spectroscopy depending on the solvent used. For the first time it has been demonstrated that nanostructures of magnesium oxyhydroxide Mg{sub 5}O(OH){sub 8} are formed during the ablation in water. It is established that in organic solvents, formation of hexagonal and cubic magnesium oxides is possible. Nanoparticles fabricated by the ablation in less thermostable solvents – ethyl acetate and hexane – contain carbonates.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Infrared Laser Ablation with Vacuum Capture for Fingermark Sampling

Infrared laser ablation coupled to vacuum capture was employed to collect material from fingermarks deposited on surfaces of different porosity and roughness. Laser ablation at 3 μm was performed in reflection mode with subsequent capture of the ejecta with a filter connected to vacuum. Ablation and capture of standards from fingermarks was demonstrated on glass, plastic, aluminum, and cardboard surfaces. Using matrix assisted laser desorption ionization (MALDI), it was possible to detect caffeine after spiking with amounts as low as 1 ng. MALDI detection of condom lubricants and detection of antibacterial peptides from an antiseptic cream was demonstrated. Detection of explosives from fingermarks left on plastic surfaces as well as from direct deposition on the same surface using gas chromatography mass spectrometry (GC-MS) was shown. .

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Comparison Between Mass Spectra of Individual Organic Particles Generated by UV Laser Ablation and in the IR/UV Two-Step Mode

One of the most fundamental aspects of single particle mass spectrometry is that the individual particle mass spectra are first classified and only then averaged. When ions are generated by ablation with a UV laser the mass spectra of particles with identical compositions exhibit large particle to particle fluctuations in the mass spectral intensity pattern. This is particularly true when it comes to particles containing organic molecules. At laser fluence that is sufficient to ionize sulfates many of the organic molecules exhibit high degree of fragmentation, often to the point where they cannot be distinguished from elemental carbon. In contrast, when ion generation is separated into two steps, in which the first step uses infra red to evaporate the semi-volatile components and the second, time delayed UV pulse to ionize the evaporating plume, the quality of the individual particle mass spectra are significantly improved. We present an experimental investigation of the properties and behavior of individual particle mass spectra of organic particles that are generated by ablation and in two steps. We investigate the effect of UV laser fluence and the delay between the two lasers. The study shows that the two step approach yields highly reproducible mass spectra that contain sufficient detail to allow clear molecular assignments. The two step approach also produces 10 times as many ions, and the mass spectral intensity can be related to the amount of organics in the particle. In contrast, ablation generated mass spectra were found to exhibit high degree of fragmentation and particle-to-particle fluctuations.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Laser hydrothermal reductive ablation of titanium monoxide: Hydrated TiO particles with modified Ti/O surface

IR laser- and UV laser-induced ablation of titanium monoxide (TM) in hydrogen (50 Torr) is compared to the same process induced in vacuum and shown to result in deposition of hydrated surface modified nanostructured titanium suboxide films. Complementary analyses of the films deposited in vacuum and in hydrogen by Fourier transform infrared, Raman and X-ray photoelectron spectroscopy, X-ray diffraction and electron microscopy allowed to determine different features of both films and propose a mechanism of surface modification of ejected particles, which involves hydrothermal reduction of TM and subsequent reactions of evolved water. The films exert good adhesion to metal and quartz surfaces and are hydrophobic in spite of having their surface coated with adsorbed water. - Graphical abstract: Laser ablation of titanium monoxide (TiO) in hydrogen involves a sequence of H{sub 2} and H{sub 2}O eliminations and additions and yields hydrated amorphous nanostructured titanium suboxide which is richer in oxygen than TiO. Highlights: Black-Right-Pointing-Pointer IR and UV laser ablated particles of titanium monoxide (TiO) undergo amorphization. Black-Right-Pointing-Pointer Films deposited in vacuum have TiO stoichiometry and are oxidized in atmosphere. Black-Right-Pointing-Pointer Films deposited in hydrogen are hydrated and have more O in topmost layers. Black-Right-Pointing-Pointer Films modification in hydrogen is explained by reactions in hydrogen plasma.

36 MATERIALS SCIENCE↗

The TriBeam system: Femtosecond laser ablation in situ SEM

Femtosecond laser ablation offers the unique ability to remove material at rates that are orders of magnitude faster than existing ion beam technologies with little or no associated damage. By combining ultrafast lasers with state-of-the-art electron microscopy equipment, we have developed a TriBeam system capable of targeted, in-situ tomography providing chemical, structural, and topographical information in three dimensions of near mm{sup 3} sized volumes. The origins, development, physics, current uses, and future potential for the TriBeam system are described in this tutorial review. - Graphical abstract: Display Omitted - Highlights: • An emerging tool, the TriBeam, for in situ femtosecond (fs) laser ablation is presented. • Fs laser ablation aided tomography at the mm{sup 3}-scale is demonstrated. • Fs laser induced deposition of Pt is demonstrated at sub-diffraction limit resolution. • Fs laser surface structuring is reviewed as well as micromachining applications.

36 MATERIALS SCIENCE↗

Laser ablation of sub-10 nm silver nanoparticles

Laser ablation of silver nanoparticles (NPs) was studied with laser post-ionization (LPI) time-of-flight mass spectrometry (TOF MS). Silver NPs containing ~15 000 Ag atoms (4 nm radius) were deposited by soft landing (energy 3 eV/atom) onto indium tin oxide (ITO)/glass substrates. Laser ablation was performed using frequency-doubled Ti:sapphire nanosecond pulsed laser irradiation at three different wavelengths (371, 401, and 421 nm), whereas for post-ionization, pulses from an F 2 laser were used. Laser fluences and time delay dependencies of Ag and In signals were obtained. Using these data, the temperature of the desorption source as well as its time duration were calculated. It was found that the peak temperature of NPs was above their melting point and they cooled down slowly, with temperature decay time of several hundreds of nanoseconds. This anomalous behavior was explained based on a model where the semiconducting ITO substrate is initially transparent to the desorption laser radiation but starts to adsorb it due to the temperature increase arising from heat exchange with NPs. Poor heat conduction in the ITO film creates conditions for long-lived hot spots on the surface and initiates further optical damage of the substrate. No difference in the ablation process due to plasmon resonance was detected, likely due to thermal expansion and melting of NPs during laser irradiation, which then broadens the plasmon absorption band enough to cover all wavelengths used. Here, these results clearly demonstrate that the process of NP interaction with laser radiation is governed not only by initial optical and thermophysical parameters of NPs and the surrounding media, but also by their alteration due to temperature increases during the irradiation process.

36 MATERIALS SCIENCE↗

Dynamics of Molecular Emission Features from Nanosecond, Femtosecond Laser and Filament Ablation Plasmas

The evolutionary paths of molecular species and nanoparticles in laser ablation plumes are not well understood due to the complexity of numerous physical processes that occur simultaneously in a transient laser-plasma system. It is well known that the emission features of ions, atoms, molecules and nanoparticles in a laser ablation plume strongly depend on the laser irradiation conditions. In this letter we report the temporal emission features of AlO molecules in plasmas generated using a nanosecond laser, a femtosecond laser and filaments generated from a femtosecond laser. Our results show that, at a fixed laser energy, the persistence of AlO is found to be highest and lowest in ns and filament laser plasmas respectively while molecular species are formed at early times for both ultrashort pulse (fs and filament) generated plasmas. Analysis of the AlO emission band features show that the vibrational temperature of AlO decays rapidly in filament assisted laser ablation plumes.

Laser ablation (LA)↗

Initiation of aluminum wire array on the 1-MA ZEBRA accelerator and its effect on ablation dynamics and x-ray yield

The effect of current prepulse on the initiation of Al wire arrays, ablation dynamics and x-ray production was investigated on the 1-MA ZEBRA accelerator (University of Nevada, Reno). It is shown that increasing the number of wires lowers the temperature of the wire cores at the time of breakdown. Al arrays with cold wire cores demonstrate long and inhomogeneous ablation, and a less intense, wider x-ray pulse. Shortening the current prepulse by a flashover switch causes an increased wire-core temperature, symmetrization and synchronization of the wires' ablation, and improvement of the amplitude and shape of the x-ray pulse. Application of a vacuum flashover switch can be important for shortening the current prepulse on the upcoming 28-MA ZR-accelerator at Sandia National Laboratories to optimize the x-ray production and shot-to-shot reproducibility from wire-array Z pinches.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Background gas effects on the generation of nanopatterns on a pure silicon wafer with multiple femtosecond near field laser ablation

Significant laser energy was transferred from the near field scanning optical microscope tip to a silicon wafer producing nanopatterns on the sample surface. The patterns changed from nanoprotrusions to nanocraters when the background gas was changed from air to argon. Two physical mechanisms were attributed to this dramatic change, namely, oxidation and laser ablation. When air was present, oxidation dominated over ablation in the formation of the nanoprotrusions obtained after multiple laser pulses. When oxygen was absent, e.g., pure argon was the background gas, laser ablation was dominant, and nanocraters resulted after multiple laser pulses.

36 MATERIALS SCIENCE↗

Laser ablation of preheated copper samples

A study of the effect of initial sample temperature on laser ablation of a copper sample at ambient air pressure by a 1064 nm, 10 ns laser pulse with energies of 11 and 15 mJ (2.7-3.2 GW/cm{sup 2}) is carried out. The sample is uniformly heated by a heating element up to 600 K. Spectral emission of plasma is measured at different initial sample temperatures and delay times. Plasma temperatures are determined from the method of line pair ratio. The temperature profile inside the preheated target, ablation depth, thickness of dielectric, and melting layer are numerically computed by the finite difference method based on the phase explosion mechanism. Results show that an increase in the initial sample temperature leads to an increase in the spectral emission of plasma up to 90% which is attributed to both the plasma temperature and the ablated volume. Initial sample temperatures have no effects on background intensity of plasma emission. Thus, for spectroscopic purposes, the signal to noise ratio can be improved with initial sample temperature.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗