Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “APS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 541 records · Page 30

Balloon-Assisted Chemoembolization Using a Micro-Balloon Catheter Alongside a Microcatheter for a Hepatocellular Carcinoma with a Prominent Arterioportal Shunt: A Case Report

Although transcatheter arterial chemoembolization is one of the established treatments for hepatocellular carcinoma (HCC), it is difficult to treat HCCs with prominent arterioportal (AP) shunts because anticancer drugs and embolic materials migrate into the non-tumorous liver through the AP shunts and may cause liver infarction. We developed a novel method of balloon-assisted chemoembolization using a micro-balloon catheter alongside a microcatheter simultaneously inserted through a single 4.5-Fr guiding sheath, comprising proximal chemoembolization with distal arterial balloon occlusion. We applied this method to treat an HCC with a prominent distal AP shunt induced by previous proton beam therapy and achieved successful chemoembolization without non-tumorous liver infarction under temporal balloon occlusion of a distal AP shunt.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

CSK hopping pattern model for visible light communication networks

This paper proposes a new channel access method for visible light communications. The transmitter uses the CSK hopping pattern mode to load data to the R, G, and B light-emitting diodes of LEDs and establishes the network access point (AP) of the LEDs for the illumination coverage area. The coordinator controls the work of each AP to ensure that it simultaneously uses different color patterns to distinguish its respective networks. When the receiver (mobile terminal) detects a particular color pattern in the illumination coverage area, it establishes a communication access network process with the AP that is transmitting the particular color pattern. The advantage of this method is that interference between adjacent APs can be avoided. In addition, due to the simplification of the access network, the proposed CSK hopping model can shorten delays in the terminal’s access network. Through modeling and simulation, it is found that this method can effectively support network power and reduce network delay. Moreover, the fairness and stability of terminals that access the network are improved to a certain extent.

42 ENGINEERING↗

Initial Studies on Development of High-Performance Nano-structured Fe{sub 2}O{sub 3} Catalysts for Solid Rocket Propellants

Space launch vehicles and strategic military vehicles commonly employ composite solid rocket propellants containing Fe{sub 2}O{sub 3} as ballistic modifier. Nanoscale catalysts, including nanoscale Fe{sub 2}O{sub 3}, have been reported to exhibit superior activity in the thermal decomposition and combustion of composite rocket propellants. However, scalable methods to prepare such nano-structured catalysts with high performance as ballistic modifiers and systematic studies relating the synthesis parameters to the catalyst characteristics and consequently to the thermal and combustion properties of the composite propellant are scarce. In this paper, we report a novel and facile route to prepare nano-structured Fe{sub 2}O{sub 3} with enhanced catalytic activity in the ballistic modification of ammonium perchlorate (AP)-based composite solid rocket propellant. A submerged spray precipitation method using air-assisted liquid-centered coaxial atomization has been developed to prepare these nano-structured Fe{sub 2}O{sub 3} catalysts. The prepared Fe{sub 2}O{sub 3} catalysts possess higher surface area and exhibit superior activity in the thermal sensitization of AP, leading to an 88% increase in the burning rate of AP-based composite solid rocket propellants, than the Fe{sub 2}O{sub 3} catalyst prepared via traditional precipitation method. Merits of the developed preparatory route, influence of the atomization process on the nano-structure morphology and subsequent benefits of these nano-structured catalysts on the ballistic properties of AP-based propellants are demonstrated and discussed in this paper.

36 MATERIALS SCIENCE↗

Silencing MR-1 attenuates inflammatory damage in mice heart induced by AngII

Myofibrillogenesis regulator-1(MR-1) can aggravate cardiac hypertrophy induced by angiotensin(Ang) II in mice through activation of NF-{kappa}B signaling pathway, and nuclear transcription factor (NF)-{kappa}B and activator protein-1(AP-1) regulate inflammatory and immune responses by increasing the expression of specific inflammatory genes in various tissues including heart. Whether inhibition of MR-1 expression will attenuate AngII-induced inflammatory injury in mice heart has not been explored. Herein, we monitored the activation of NF-{kappa}B and AP-1, together with expression of pro-inflammatory of interleukin(IL)-6, tumor necrosis factor(TNF)-{alpha}, vascular-cell adhesion molecule (VCAM)-1, platelet endothelial cell adhesion molecule (PECAM), and inflammatory cell infiltration in heart of mice which are induced firstly by AngII (PBS),then received MR-1-siRNA or control-siRNA injecting. We found that the activation of NF-{kappa}B and AP-1 was inhibited significantly, together with the decreased expression of IL-6, TNF-{alpha}, VCAM-1, and PECAM in AngII-induced mice myocardium in MR-1-siRNA injection groups compared with control-siRNA injecting groups. However, the expression level of MR-1 was not an apparent change in PBS-infused groups than in unoperation groups, and MR-1-siRNA do not affect the expression of MR-1 in PBS-infused mice. Our findings suggest that silencing MR-1 protected mice myocardium against inflammatory injury induced by AngII by suppression of pro-inflammatory transcription factors NF-{kappa}B and AP-1 signaling pathway.

60 APPLIED LIFE SCIENCES↗

Characterization of human AlkB homolog 1 produced in mammalian cells and demonstration of mitochondrial dysfunction in ALKBH1-deficient cells

Highlights: • Mammalian produced ALKBH1 (ALKBH1{sub 293}) possesses m{sup 6}A demethylase and AP lyase activity. • ALKBH1{sub 293} forms an adduct with the 5′-product of the AP lyase reaction. • ALKBH1 localizes to the mitochondria in MSU1.1 and HEK293 cells. • ALKBH1-deficient cells exhibit mitochondrial dysfunction. Alkbh1 is a mammalian homolog of the Escherichia coli DNA repair enzyme AlkB, an Fe(II) and 2-oxoglutarate dependent dioxygenase that removes alkyl lesions from DNA bases. The human homolog ALKBH1 has been associated with six different enzymatic activities including DNA, mRNA, or tRNA hydroxylation, cleavage at abasic (AP) sites in DNA, as well as demethylation of histones. The reported cellular roles of this protein reflect the diverse enzymatic activities and include direct DNA repair, tRNA modification, and histone modification. We demonstrate that ALKBH1 produced in mammalian cells (ALKBH1{sub 293}) is similar to the protein produced in bacteria (ALKBH1{sub Ec}) with regard to its m{sup 6}A demethylase and AP lyase activities. In addition, we find that ALKBH1{sub 293} forms a covalent adduct with the 5′ product of the lyase product in a manner analogous to ALKBH1{sub Ec}. Localization and subcellular fractionation studies with the endogenous protein in two human cell strains confirm that ALKBH1 is primarily in the mitochondria. Two strains of CRISPR/Cas9-created ALKBH1-deficient HEK293 cells showed increases in mtDNA copy number and mitochondrial dysfunction as revealed by growth measurements and citrate synthase activity assays.

60 APPLIED LIFE SCIENCES↗

The simultaneous removal of technetium and iodine from Hanford tank waste

The simultaneous removal of radionuclides technetium-99 and iodine-129 from an actual decontaminated Hanford tank waste sample (a mixture of decontaminated waste from tanks 241-AP-105 and 241-AP-107) was demonstrated for the first time in this work. A series of commercially available ion exchange resins were evaluated in batch contact tests in the tank waste, and all showed removal of both Tc and I. The highest Tc removal was observed for Purolite A530e while the highest iodine removal was observed for ResinTech SIR-110-MP. Batch tests in simulated tank waste with these two resins showed that the SIR-110-HP-MP had consistently higher K d for both pertechnetate and iodide and much higher K d than previous works on Tc removal from Hanford waste. As such, the SIR-110-MP was evaluated in a dual -column (lead/lag) test processing 5.2L of the tank waste mixture showing 60% breakthrough of Tc on the lead column and no significant breakthrough on the lag after 625 bed volumes (BV, 6 mL size) while significant iodine breakthrough (>50%) occurred after 28 BV. The limited iodine uptake was attributed to the column conditions generating mass transfer limitations. A fraction of the Tc and I was not captured by the resin (<10%) in either the batch tests or column tests. The iodine fraction was identified to be an iodide, likely organo-iodide. The fraction of the Tc was identified as a non-pertechnetate species, which is the first time non-pertechnetate has been identified in AP-105 and AP-107 tanks, although the exact species is still unknown.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Capacitive Deionization Using Alternating Polarization: Effect of Surface Charge on Salt Removal

Alternating polarization (AP) at ±1.2/0 V is performed on a capacitive deionization stack assembled with carbon xerogel (CX) electrodes. Long-term testing shows enhanced cycling stability without the formation of inversion peaks. AP also leads to an arch-shaped plot of salt adsorption capacity (SAC) versus cycling time, with the highest SAC of approximately 3 mg (NaCl) g −1 (CX) during this long-term test. Characterization of both the freshly prepared and cycled electrodes depict that AP results in surface charge of all the electrodes being modified from positive to negative character. Here by leveraging balances of electronic, surface, and ionic charges in carbon micropores, it is found that a portion of the electronic charge contributes to the ionic charge for salt adsorption, and another portion is parasitically consumed to balance the surface charge during the charge reconciliation process. When the consumption of electronic charge for charge reconciliation becomes minimal, both the positive and negative surface charges are nearly equivalent on the CX electrode. Under such a condition, the highest SAC values can be achieved for AP testing.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Development of low-cost sodium-aqueous polysulfide hybrid batteries

There has been increasing interest in sodium-sulfur (Na-S) batteries as an option for low-cost grid-scale energy storage. Yet, traditional Na-S batteries operate at high temperatures, raising concerns about long-term maintenance costs and safety. On the other hand, room-temperature Na-S batteries have their own limitations, including Na dendrite formation, polysulfide shuttling, and low utilization of active material. To overcome these issues, we introduce here a novel low-cost room-temperature sodium-aqueous polysulfide (Na-APS) hybrid battery system with a Na-metal anode, Na+-ion solid electrolyte separator, and an aqueous polysulfide catholyte. The solid electrolyte blocks Na dendrites and polysulfide shuttling while simultaneously protecting the reactive Na metal anode from the aqueous catholyte. The redox kinetics of the APS catholyte is improved with a rational development of a freestanding CuS-CNT catalytic electrode. The improvements with the Na-APS hybrid battery compared to the traditional Na-S battery systems are discussed. The Na-APS hybrid battery displays excellent performance under a 418 mA h g -1 of sulfur capacity-restricted cycling. The battery achieves an energy efficiency of 90% over 100 cycles at 0.5 mA cm -2 current density.

25 ENERGY STORAGE↗

Supermolecular structures of recrystallized starches with amylopectin side chains modified by amylosucrase to different chain lengths

Understanding the supermolecular structures of recrystallized starches is imperative to manufacture novel starches with controllable physicochemical properties enabling novel applications. In this study, native amylopectin (AP) from maize was modified to different chain lengths using amylosucrase from Neisseria polysaccharea. Native AP granules showed well-organized lamellar structures with a periodicity of ca. 9.0 nm whereas modified starches formed heterogeneous structures with the average crystallite size ranging from 19.77 to 29.88 nm. Acidic treatments eroded amorphous domains in both native AP granules and modified starch particles, producing nanocrystals composed of double helices. A-type nanocrystals (~40 nm) from native AP granules showed quadrangular shape with an acute angle of ca. 60°, while irregular B-type nanocrystals were observed for the modified starches. Molecular characterizations suggested that the nanocrystals had relatively uniform chain lengths (DP 16.5–25.2), and the helix length (the thickness of nanocrystals) was positively correlated to the thermal stability of starches.

60 APPLIED LIFE SCIENCES↗

Focusing ions at atmospheric pressure using nonlinear DC voltage sequences applied to a stacked ring ion guide

Many modern ion mobility (IM) and mass spectrometers (MS) operate under low pressure (= 10 Torr) and employ high voltage radiofrequencies (RF) to provide ion confinement. Unfortunately, RF effectiveness drastically decreases as pressure increases, and few techniques for focusing ions at elevated pressures exist. Here we demonstrate a new approach for focusing ions at atmospheric pressure (AP) by applying nonlinear DC voltage sequences following quadratic and power (exponential) functions to a stacked ring ion guide. In this work, we used ion trajectory simulations to rigorously explore how ions react to nonlinear electric fields and validate the simulations with a set of ion current measurements performed at AP. Ion trajectory simulations show that ions initially defocus near the entrance of the device but then become intensely focused as they travel through the device. Contour plots for both nonlinear voltage sequences show electric field lines that increasingly curve inwards as a function of distance, resulting in spatial ion focusing. Experimental ion current and spot size measurements were performed at AP using a 10-cm stacked ring ion guide and a segmented Faraday cup detector. Quadratic sequences produced ~5% smaller spot sizes (~22.8 mm) and ~25% higher ion current compared to a linear voltage sequence (~24.0 mm). Alternatively, power sequences produced ~64% smaller spot sizes (~8.7 mm), albeit with ~10x lower ion current. However, both nonlinear voltage sequences produced similar ion currents at the center of the Faraday cup detector, indicating that higher ion densities are achieved when using nonlinear voltage gradients. These results demonstrate a new way to focus ions at AP, and the capabilities demonstrated here provide fundamental insights on how to keep ions inside analytical devices at elevated pressures without RF.

47 OTHER INSTRUMENTATION↗

Analysis of Interfraction Prostate Motion Using Megavoltage Cone Beam Computed Tomography

Purpose: Determine the degree of interfraction prostate motion and its components measured by using daily megavoltage (MV) cone beam computed tomography (CBCT) imaging. Methods and Materials: A total of 984 daily MV CBCT images from 24 patients undergoing definitive intensity-modulated radiotherapy for localized prostate cancer were analyzed retrospectively. Pretreatment couch shifts, based on physician registration of MV CBCT to planning CT data sets, were used as a measure of daily interfraction motion. Off-line bony registration was performed to separate bony misalignment from internal organ motion. Interobserver and intraobserver variation studies were performed on 20 MV CBCT images. Results: Mean interfraction prostate motion was 6.7 mm, with the greatest single-axis deviation in the anterior-posterior (AP) direction. The largest positional inaccuracy was accounted for by systematic deviations in bony misalignment, whereas random deviations occurred from bony misalignment and internal prostate motion. In the aggregate, AP motion did not correlate with days elapsed since beginning therapy or on average with rectal size at treatment planning. Interobserver variation was greatest in the AP direction, decreased in experienced observers, and further decreased in intraobserver studies. Mean interfraction motion during the first 6 days of therapy, when used as a subsequent offset, reduced acceptable AP planning target volume margins by 50%. Conclusion: The MV CBCT is a practical direct method of daily localization that shows significant interfraction motion with respect to conventional three-dimensional conformal and intensity-modulated radiotherapy margins, similar to that measured in other modalities.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Generic Planning Target Margin for Rectal Cancer Treatment Setup Variation

Purpose: To calculate the generic planning target margin (GPTM) for patients receiving radiation therapy (RT) for rectal cancer placed in a prone position with a customized cradle for small-bowel exclusion. Methods and Materials: A total of 25 consecutive rectal cancer patients were treated for 25 or 28 fractions in a prone position using a cradle to maximize small bowel exclusion. Treatment planning computed tomography (CT) scans were used to create orthogonally digitally reconstructed radiographs (DRRs) for portal image registration, which were compared with daily portal images from an electronic portal-imaging device (EPID). Translation values needed to align the DRRs and EPIDs were recorded for the superior to inferior (SI), right to left (RL), and anterior to posterior (AP) directions, and used to calculate the GPTM using the four-parameter model. Age, weight, and body mass index were tested compared with the setup variation using a Pearson correlation and a t test for significance. Gender versus setup variation was compared with a t test. Results: A total of 1,723 EPID images were reviewed. The GPTM was 10 mm superior, 8 mm inferior, 7 mm RL and 10 mm AP. Age and gender were unrelated to setup variation. Weight was significantly associated with systematic AP variation (p < 0.05). BMI was significantly associated with systematic SI (p < 0.05) and AP (p < 0.01) variation and random RL variation (p < 0.05). Conclusions: The GPTM for rectal cancer is asymmetric with a maximum of 10 mm in the superior, anterior and posterior dimensions. Body mass index may effect setup variation. Research using advanced treatment planning should include these margins in the planning target volume definition.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Comparison of CT on Rails With Electronic Portal Imaging for Positioning of Prostate Cancer Patients With Implanted Fiducial Markers

Purpose: The objective of this investigation was to measure the agreement between in-room computed tomography (CT) on rails and electronic portal image (EPI) radiography. Methods and Materials: Agreement between the location of the center of gravity (COG) of fiducial markers (FMs) on CT and EPI images was determined in phantom studies and a patient cohort. A secondary analysis between the center of volume (COV) of the prostate on CT and the COG of FMs on CT and EPI was performed. Agreement was defined as the 95% probability of a difference of {<=}3.0 mm between images. Systematic and random errors from CT and EPI are reported. Results: From 8 patients, 254 CT and EPI pairs were analyzed. FMs were localized to within 3 mm on CT and EPI images 96.9% of the time in the left-right (LR) plane, 85.8% superior-inferior (SI), and 89% anterior-posterior (AP). The differences between the COV on CT and the COG on EPI were not within 3 mm in any plane: 87.8% (LR), 64.2% (SI), and 70.9% (AP). The systematic error varied from 1.2 to 2.9 mm (SI) and 1.8-2.9 mm (AP) between the COG on EPI and COV on CT. Conclusions: Considerable differences between in-room CT and EPI exist. The phantom measurements showed slice thickness affected the accuracy of localization in the SI plane, and couch sag that occurs at the CT on rails gantry could not be totally corrected for in the AP plane. Other confounding factors are the action of rotating the couch and associated time lag between image acquisitions (prostate motion), EPI image quality, and outlining uncertainties.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Inter- and Intrafraction Variability in Liver Position in Non-Breath-Hold Stereotactic Body Radiotherapy

Purpose: The inter- and intrafraction variability of liver position was assessed in patients with liver cancer treated with kilovoltage cone-beam computed tomography (CBCT)-guided stereotactic body radiotherapy. Methods and Materials: A total of 314 CBCT scans obtained in the treatment position immediately before and after each fraction were evaluated from 29 patients undergoing six-fraction, non-breath-hold stereotactic body radiotherapy for unresectable liver cancer. Off-line, the CBCT scans were sorted into 10 bins, according to the phase of respiration. The liver position (relative to the vertebral bodies) was measured using rigid alignment of the exhale CBCT liver with the exhale planning CT liver, following the alignment of the vertebrae. The interfraction liver position change was measured by comparing the pretreatment CBCT scans, and the intrafraction change was measured from the CBCT scans obtained immediately before and after each fraction. Results: The mean amplitude of liver motion for all patients was 1.8 mm (range, 0.1-5.7), 8.0 mm (range, 0.1-18.8), and 4.3 mm (range 0.1-12.1) in the medial-lateral (ML), craniocaudal (CC), and anteroposterior (AP) directions, respectively. The mean absolute ML, CC, and AP interfraction changes in liver position were 2.0 mm (90th percentile, 4.2), 3.5 mm (90th percentile, 7.3), and 2.3 mm (90th percentile, 4.7). The mean absolute intrafraction ML, CC, and AP changes were 1.3 mm (90th percentile, 2.9), 1.6 mm (90th percentile, 3.6), and 1.5 mm (90th percentile, 3.1), respectively. The interfraction changes were significantly larger than the intrafraction changes, with a CC systematic error of 2.9 and 1.1 mm, respectively. The intraobserver reproducibility ({sigma}, n = 29 fractions) was 1.3 mm in the ML, 1.4 mm in the CC, and 1.6 mm in the AP direction. Conclusion: Interfraction liver position changes relative to the vertebral bodies are an important source of geometric uncertainty, providing a rationale for prefraction soft-tissue image guidance. The intrafraction change in liver position from the beginning to the end of each fraction was small for most patients.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A Prospective Study of Intrafraction Prostate Motion in the Prone vs. Supine Position

Purpose: To prospectively analyze prostate intrafraction motion in the prone vs. supine position and to assess patient satisfaction with these two positions. Methods and Materials: Fifteen prostate cancer patients underwent implantation of five fiducial gold seeds in their prostate for localization. Patients were treated with high-dose-rate brachytherapy to 2,200 cGy followed by intensity-modulated radiation therapy (IMRT) to 5,040 cGy. Patients underwent computed tomography simulation and IMRT in the prone position. For the first five IMRT treatments, an electronic portal imaging system was used to acquire anteroposterior (AP) and lateral images pretreatment and posttreatment. We then repositioned each patient supine and repeated the process, resulting in 600 images. Results: Mean +- standard deviation intrafraction prostate motion was 2.1 +- 1.2 mm and 1.7 +- 1.4 mm (AP, p = 0.47), 2.2 +- 2.0 mm and 1.6 +- 1.8 mm (superoinferior, p = 0.16), and 1.0 +- 1.2 mm and 0.6 +- 0.9 mm (left-right, p = 0.03) in the prone and supine positions, respectively. Eighty percent of patients stated that they were more comfortable in the supine position (p = 0.02). Conclusions: Prone and supine positions resulted in a similar magnitude of AP and superoinferior intrafraction prostate motion (2 mm). Because there was no significant difference in the magnitude of AP and superoinferior prostate motion prone vs. supine and patients were more comfortable in the supine position, patients now undergo IMRT to the prostate and seminal vesicles at our center in the supine position.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Interfraction and Respiratory Organ Motion During Conformal Radiotherapy in Gastric Cancer

Purpose: To quantify the interfraction and breathing organ motion during adjuvant radiotherapy for gastric cancer and assess organ stability in different breathing states. Methods and Materials: A planning computed tomography (CT) scan and serial study CT scans in free breathing, voluntary inhale and exhale were performed in weeks 1, 3, and 5 of radiotherapy for 22 resected gastric patients. All data sets were fused to register the vertebral bodies. The regions of interest (kidneys, stomach, liver, pancreas, celiac axis, and porta hepatis) or points of interest (POIs; left dome of diaphragm, splenic hilum) were identified. For each region of interest, a POI was automatically placed at the center of mass. The interfraction displacement and breathing amplitude were assessed in the craniocaudal (CC), anteroposterior (AP), and right-left (RL) directions. Results: Comparison of the serial free-breathing CT scans with the planning CT scan showed a median displacement of all POIs of 5.6, 2.2, and 1.8 mm in the CC, AP, and RL directions, respectively. Comparison of the serial inhale scans with the first inhale scan showed a displacement of 4.9, 2.6, and 1.8 mm in the CC, AP, and RL directions, respectively. The comparable values for the exhale scans were 5.1, 2.0, and 1.8 mm. The displacements of the organs were similar in the free breathing, inhale, and exhale states. The median respiratory amplitude in the CC, AP, and RL direction was 14, 4.8, and 1.7 mm, respectively. Conclusion: The median interfraction displacement of the POIs relative to the vertebral bodies was about 6 mm in the CC direction and 2 mm in the other directions. The planning target volume margins need to account for these shifts. Individual assessment of respiratory motion is recommended to identify patients with unusually large respiratory amplitude.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Results of a Multi-Institution Deformable Registration Accuracy Study (MIDRAS)

Purpose: To assess the accuracy, reproducibility, and computational performance of deformable image registration algorithms under development at multiple institutions on common datasets. Methods and Materials: Datasets from a lung patient (four-dimensional computed tomography [4D-CT]), a liver patient (4D-CT and magnetic resonance imaging [MRI] at exhale), and a prostate patient (repeat MRI) were obtained. Radiation oncologists localized anatomic structures for accuracy assessment. Algorithm accuracy was determined by comparing the computer-predicted displacement at each bifurcation point with the displacement computed from the oncologists' annotations. Thirty-seven academic institutions and medical device manufacturers with published evidence of active deformable image registration capabilities were invited to participate. Results: Twenty-seven groups agreed to participate; 6 did not return results. Sixteen completed the liver 4D-CT, 12 the lung 4D-CT, 3 the prostate MRI, and 3 the liver MRI-CT. The range of average absolute error for the lung 4D-CT was 0.6-1.2 mm (left-right [LR]), 0.5-1.8 mm (anterior-posterior [AP]), and 0.7-2.0 mm (superior-inferior [SI]); the liver 4D-CT was 0.8-1.5 mm (LR), 1.0-5.2 mm (AP), and 1.0-5.9 mm (SI); the liver MRI-CT was 1.1-2.6 mm (LR), 2.0-5.0 mm (AP), and 2.2-2.6 mm (SI); and the repeat prostate MRI prostate datasets was 0.5-6.2 mm (LR), 3.1-3.7 mm (AP), and 0.4-2.0 mm (SI). Conclusions: An infrastructure was developed to assess multi-institution deformable registration accuracy. The results indicate large discrepancies in reported shifts, although the majority of deformable registration algorithms performed at an accuracy equivalent to the voxel size, promising to improve treatment planning, delivery, and assessment.

62 RADIOLOGY AND NUCLEAR MEDICINE↗