Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “APPLICATIONS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 541 records · Page 30

Contrast-Matched Small-Angle X-ray Scattering from a Heavy-Atom-Labeled Protein in Structure Determination: Application to a Lead-Substituted Calmodulin-Peptide Complex

The information content in 1-D solution X-ray scattering profiles is generally restricted to low-resolution shape and size information that, on its own, cannot lead to unique 3-D structures of biological macromolecules comparable to all-atom models derived from X-ray crystallography or NMR spectroscopy. Here we show that contrast-matched X-ray scattering data collected on a protein incorporating specific heavy-atom labels in 65% aqueous sucrose buffer can dramatically enhance the power of conventional small- and wide-angle X-ray scattering (SAXS/WAXS) measurements. Under contrast-matching conditions the protein is effectively invisible and the main contribution to the X-ray scattering intensity arises from the heavy atoms, allowing direct extraction of pairwise distances between them. In combination with conventional aqueous SAXS/WAXS data, supplemented by NMR-derived residual dipolar couplings (RDCs) measured in a weakly aligning medium, we show that it is possible to position protein domains relative to one another within a precision of 1 Å. We demonstrate this approach with respect to the determination of domain positions in a complex between calmodulin, in which the four Ca 2+ ions have been substituted by Pb 2+ , and a target peptide. The uniqueness of the resulting solution is established by an exhaustive search over all models compatible with the experimental data, and could not have been achieved using aqueous SAXS and RDC data alone. Moreover, we show that the correct structural solution can be recovered using only contrast-matched SAXS and aqueous SAXS/WAXS data.

Grishaev, Alexander↗

General Kinetic Model for pH Dependence of Proton-Coupled Electron Transfer: Application to an Electrochemical Water Oxidation System

The pH dependence of proton-coupled electron transfer (PCET) reactions, which are critical to many chemical and biological processes, is a powerful probe for elucidating their fundamental mechanisms. Herein, a general, multichannel kinetic model is introduced to describe the pH dependence of both homogeneous and electrochemical PCET reactions. According to this model, a weak pH dependence can arise from the competition among multiple sequential and concerted PCET channels involving different forms of the redox species, such as protonated and deprotonated forms, as well as different proton donors and acceptors. The contribution of each channel is influenced by the relative populations of the reactant species, which often depend strongly on pH, leading to complex pH dependence of PCET apparent rate constants. This model is used to explain the origins of the experimentally observed weak pH dependence of the electrochemical PCET apparent rate constant for a ruthenium-based water oxidation catalyst attached to a tin-doped In2O3 (ITO) surface. The weak pH dependence is found to arise from the intrinsic differences in the rate constants of participating channels and the dependence of their relative contributions on pH. This model predicts that the apparent maximum rate constant will become pH-independent at higher pH, which is confirmed by experimental measurements. Our analysis also suggests that the dominant channels are electron transfer at lower pH and sequential PCET via electron transfer followed by fast proton transfer at higher pH. Furthermore, this work highlights the importance of considering multiple competing channels simultaneously for PCET processes.

Catalysts↗

Exciton Absorption Spectra by Linear Response Methods: Application to Conjugated Polymers

The theoretical description of the time-evolution of excitons requires, as an initial step, the calculation of their spectra, which has been inaccessible to most users due to the high computational scaling of conventional algorithms and accuracy issues caused by common density functionals. Previously (J. Chem. Phys.2016, 144, 204105), we developed a simple method that resolves these issues. Our scheme is based on a two-step calculation in which a linear-response TDDFT calculation is used to generate orbitals perturbed by the excitonic state, and then a second linear-response TDDFT calculation is used to determine the spectrum of excitations relative to the excitonic state. Herein, we apply this theory to study near-infrared absorption spectra of excitons in oligomers of the ubiquitous conjugated polymers poly(3-hexylthiophene) (P3HT), poly(2-methoxy-5-(2-ethylhexyloxy)-1,4-phenylenevinylene) (MEH-PPV), and poly(benzodithiophene-thieno[3,4-b]thiophene) (PTB7). For P3HT and MEH-PPV oligomers, the calculated intense absorption bands converge at the longest wavelengths for 10 monomer units, and show strong consistency with experimental measurements. The calculations confirm that the exciton spectral features in MEH-PPV overlap with those of the bipolaron formation. In addition, our calculations identify the exciton absorption bands in transient absorption spectra measured by our group for oligomers (1, 2, and 3 units) of PTB7. For all of the cases studied, we report the dominant orbital excitations contributing to the optically active excited state–excited state transitions, and suggest a simple rule to identify absorption peaks at the longest wavelengths. We suggest our methodology could be considered for further developments in theoretical transient spectroscopy to include nonadiabatic effects, coherences, and to describe the formation of species such as charge-transfer states and polaron pairs.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

GPM IMERG V07B and V06B: Evaluation Using Ground-Based Radar Observations and Application in Global Mesoscale Convective System Tracking

This study evaluates the latest Global Precipitation Measurement (GPM) Integrated Multi-satellitE Retrievals for GPM (IMERG V07B) against its predecessor V06B, for studying mesoscale convective systems (MCSs). Both versions are compared using ground-based radar and rain gauge data from five meteorologically diverse regions: the contiguous United States (including eastern coastlines), Amazon rainforest, central Argentina mountains, equatorial Indian Ocean, and northern Australia across multiple temporal (0.5–6 hours) and spatial scales (0.1°–0.25°). An updated global MCS tracking dataset is developed by integrating satellite-observed infrared brightness temperature with IMERG V07B. Comparation of IMERG against radar observations reveals that IMERG demonstrates better performance in capturing the probability distribution and quantitative contributions of rainfall (from no-rain to intense-rain conditions) over tropical oceans than over land, with marked improvements in IMERG V07B for heavy-to-intense rain (> 10 mm h-1). Over land, systematic biases persist: IMERG tends to overestimate light-to-moderate rain (1–10 mm h-1) while underestimating heavy-to-intense rain. Additionally, aggregating IMERG to coarser resolutions (3-hourly or 0.25°) improves consistency with radar observations, outperforming the 1-hourly/0.1° resolution. The new IMERG V07B-based global MCS dataset exhibits consistent statistical characteristics with the V06B-based dataset, despite lower mean rain rates and reduced heavy precipitation contributions. These findings offer valuable insights for utilizing IMERG V07B in global precipitation studies, MCS characterization, and model evaluation.

Zhang, Sihan↗

In silico screening of metal–organic frameworks in separation applications

Porous materials such as metal–organic frameworks (MOFs) and zeolitic imidazolate frameworks (ZIFs) offer considerable potential for separating a variety of mixtures such as those relevant for CO₂ capture (CO₂/H₂, CO₂/CH₄, CO₂/N₂), CH₄/H₂, alkanes/alkenes, and hydrocarbon isomers. There are basically two different separation technologies that can be employed: (1) a pressure swing adsorption (PSA) unit with a fixed bed of adsorbent particles, and (2) a membrane device, wherein the mixture is allowed to permeate through a micro-porous crystalline layer. In view of the vast number of MOFs, and ZIFs that have been synthesized there is a need for a systematic screening of potential candidates for any given separation task. Also of importance is to investigate how MOFs and ZIFs stack up against the more traditional zeolites such as NaX and NaY with regard to their separation characteristics. This perspective highlights the potency of molecular simulations in determining the choice of the best MOF or ZIF for a given separation task. A variety of metrics that quantify the separation performance, such as adsorption selectivity, working capacity, diffusion selectivity, and membrane permeability, are determined from a combination of Configurational-Bias Monte Carlo (CBMC) and Molecular Dynamics (MD) simulations. The practical utility of the suggested screening methodology is demonstrated by comparison with available experimental data.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Optimization of mesoporous carbon structures for lithium–sulfur battery applications

Mesoporous carbon (MC) with tunable pore sizes (22nm, 12nm, 7nm, and 3nm) and pore volumes (from 1.3 to 4.8 cc/g) containing sulfur inside the pores were systematically studied as mesoporous carbon-sulfur (MCS) composite electrodes for Li-S batteries. Investigation on these MCS composites reveals that the pore structure has no influence on the battery performance at full sulfur loading conditions (the pore volume is fully filled by sulfur) but the maximum sulfur loading capability is higher for MC with larger pore volume. MC with large pore volumes, partial sulfur filling (part of the pore volume left unfilled), and surface modification, can have reasonably high sulfur loading, improved electrical and ionic contacts of sulfur with MC and with electrolytes, which subsequently promotes the battery performance. An initial capacity of ~1250 mAh/g (based on sulfur) and 650 mAh/g capacity retention over 100 cycles were obtained with 50 wt% sulfur loading in the MC with 22nm pore size (4.8 cc/g). When the surface of MCS was coated with Clevios P to reduce the dissolve of polysulfide anions in electrolytes, it exhibits a high initial discharge capacity of ~1390 mAh/g and improved cycling stability with capacity retention of ~840 mAh/g over 100 cycles. The reported correlation among the structure, sulfur filling, surface modification and the electrochemical performance of the MCS composite cathodes provides guidance in designing new electrodes for lithium-sulfur batteries

25 ENERGY STORAGE↗