Engineering PapersSearch

SEARCH · Engineering Papers

Results for “wind generation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Further Discussion: Parametric Study of Wind Generated Supermicron Particle Effects in Large Fires

In their reply (Porch et al., 1987) to our comments (Turco et al., 1987) on their smoke-scavenging-by-dust paper, Porch et al. attempt to justify a number of parameter assumptions in their original article, again revealing the extreme nature of those assumptions, particularly in the situation where all are taken simultaneously. In critiquing Porch et al.'s calculations, have not applied "opinion", but rather physical reality and common sense expressed through basic experimental results and logical physical bounds. A few examples of the unrealistic conditions required by the Porch et al. scavenging scheme, as described in their paper and comments, should suffice here. ) Porch et al. have fabricated a "fetch" region for dust particles in large fire plumes that logically must extend over an area up to 50 times greater than the fire area itself. Alternatively, they have invoked significant "necking down' of the fire plume, so that its cross-sectional area is at most a few percent of the fire area. Such severe constriction is seen only in very small fires with strong, organized vorticity, and then only over a limited plume rise region. No "fetch" has ever been noted in any large-scale fires we have observed, or for which accounts are available. Indeed, as we deduced in our original comments, complete dust scavenging even within the fire zone would probably occur less than 10% of the time for large urban fires.

Toon, O. B.

Wind wheel electric power generator

Wind wheel electric power generator apparatus includes a housing rotatably mounted upon a vertical support column. Primary and auxiliary funnel-type, venturi ducts are fixed onto the housing for capturing wind currents and conducting to a bladed wheel adapted to be operatively connected with the generator apparatus. Additional air flows are also conducted onto the bladed wheel; all of the air flows positively effecting rotation of the wheel in a cumulative manner. The auxiliary ducts are disposed at an acute angle with respect to the longitudinal axis of the housing, and this feature, together with the rotatability of the housing and the ducts, permits capture of wind currents within a variable directional range.

Kaufman, J. W.

Effect of wind turbine generator model and siting on wind power changes out of large WECS arrays

Methods of reducing the WECS generation change through selection of the wind turbine model for each site, selection of an appropriate siting configuration, and wind array controls are discussed. An analysis of wind generation change from an echelon and a farm for passage of a thunderstorm is presented. Reduction of the wind generation change over ten minutes is shown to reduce the increase in spinning reserve, unloadable generation and load following requirements on unit commitment when significant WECS generation is present and the farm penetration constraint is satisfied. Controls on the blade pitch angle of all wind turbines in an array or a battery control are shown to reduce both the wind generation change out of an array and the effective farm penetration in anticipation of a storm so that the farm penetration constraint may be satisfied.

Schleuter, R. A.

Substituted Quaternary Ammonium Salts Improve Low-Temperature Performance of Double-Layer Capacitors

Double-layer capacitors are unique energy storage devices, capable of supporting large current pulses as well as a very high number of charging and discharging cycles. The performance of doublelayer capacitors is highly dependent on the nature of the electrolyte system used. Many applications, including for electric and fuel cell vehicles, back-up diesel generators, wind generator pitch control back-up power systems, environmental and structural distributed sensors, and spacecraft avionics, can potentially benefit from the use of double-layer capacitors with lower equivalent series resistances (ESRs) over wider temperature limits. Higher ESRs result in decreased power output, which is a particular problem at lower temperatures. Commercially available cells are typically rated for operation down to only 40 C. Previous briefs [for example, Low Temperature Supercapacitors (NPO-44386), NASA Tech Briefs, Vol. 32, No. 7 (July 2008), p. 32, and Supercapacitor Electrolyte Solvents With Liquid Range Below 80 C (NPO-44855), NASA Tech Briefs, Vol. 34, No. 1 (January 2010), p. 44] discussed the use of electrolytes that employed low-melting-point co-solvents to depress the freezing point of traditional acetonitrile-based electrolytes. Using these modified electrolyte formulations can extend the low-temperature operational limit of double-layer capacitors beyond that of commercially available cells. This previous work has shown that although the measured capacitance is relatively insensitive to temperature, the ESR can rise rapidly at low temperatures, due to decreased electrolyte conductance within the pores of the high surface- area carbon electrodes. Most of these advanced electrolyte systems featured tetraethylammonium tetrafluoroborate (TEATFB) as the salt. More recent work at JPL indicates the use of the asymmetric quaternary ammonium salt triethylmethylammonium tetrafluoroborate (TEMATFB) or spiro-(l,l')-bipyrrolidium tetrafluoroborate (SBPBF4) in a 1:1 by volume solvent mixture of acetonitrile (AN) and methyl formate (MF) enables double-layer capacitor cells to operate well below -40 C with a relatively low ESR. Typically, a less than twofold increase in ESR is observed at -65 C relative to room-temperature values, when these modified electrolyte blends are used in prototype cells. Double-layer capacitor coin cells filled with these electrolytes have displayed the lowest measured ESR for an organic electrolyte to date at low temperature (based on a wide range of electrolyte screening studies at JPL). The cells featured high-surface-area (approximately equal to 2,500 m/g) carbon electrodes that were 0.50 mm thick and 1.6 cm in diameter, and coated with a thin layer of platinum to reduce cell resistance. A polyethylene separator was used to electrically isolate the electrodes.

Brandon, Erik J.

Noise generation of upwind motor wind turbine generators

Noise sources of wind turbines with rotors upstream of the support structure are discussed along with methodology for sound level prediction. Estimated noise levels for the MOD-2 wind turbine are presented operating in both the upwind and downwind configurations. Results indicate that upwind rotor configurations may be advantageous from an acoustical standpoint.

Spencer, R. H.

Synchronization of wind turbine generators against an infinite bus under gusting wind conditions

Studies of synchronizing a wind turbine generator against an infinite bus are performed on a digital computer. In the digital simulation, wind gusts of different magnitudes and durations are hypothesized. Prior to the synchronization, differences of the frequency and phase position between voltages of the alternator and the bus are also included in the simulation. Solutions for rotor speed, generator power angle, electromagnetic torque, wind turbine torque, wind turbine blade pitch angle, and armature current are simulated and presented graphically. The ERDA-NASA 100-kW wind turbine is used as a case study. The results so obtained will thus have immediate applications.

Hwang, H. H.

Large wind turbine generators

The large wind turbine portion of the Federal Wind Energy Program consists of two major project efforts: (1) the Mod-0 test bed project for supporting research technology, and (2) the large experimental wind turbines for electric utility applications. The Mod-0 has met its primary objective of providing the entire wind energy program with early operations and performance data. The large experimental wind turbines to be tested in utility applications include three of the Mod-0A (200 kW) type, one Mod-1 (2000 kW), and possibly several of the Mod-2 (2500 kW) designs. This paper presents a description of these wind turbine systems, their programmatic status, and a summary of their potential costs.

Thomas, R. L.

Lightning accommodation systems for wind turbine generator safety

The wind turbine safety program identifies the naturally occurring lightning phenomenon as a hazard with the potential to cause loss of program objectives, injure personnel, damage system instrumentation, structure or support equipment and facilities. Several candidate methods of lightning accommodation for each blade were designed, analyzed, and tested by submitting sample blade sections to simulated lightning. Lightning accommodation systems for composite blades were individually developed. Their effectiveness was evaluated by submitting the systems to simulated lightning strikes. The test data were analyzed and system designs were reviewed on the basis of the analysis. This activity is directed at defining design and procedural constraints, requirements for safety devices and warning methods, special procedures, protective equipment and personnel training.

Bankaitis, H.

Background and system description of the Mod 1 wind turbine generator

The Mod-1 wind turbine considered is a large utility-class machine, operating in the high wind regime, which has the potential for generation of utility grade power at costs competitive with other alternative energy sources. A Mod-1 wind turbine generator (WTG) description is presented, taking into account the two variable-pitch steel blades of the rotor, the drive train, power generation/control, the Nacelle structure, and the yaw drive. The major surface elements of the WTG are the ground enclosure, the back-up battery system, the step-up transformer, elements of the data system, cabling, area lighting, and tower foundation. The final system weight (rotor, Nacelle, and tower) is expected to be about 650,000 pounds. The WTG will be capable of delivering 1800 kW to the utility grid in a wind-speed above 25 mph.

Ernst, E. H.

Utility experience with two demonstration wind turbine generators

Edison has committed 360 MW of nameplate generating capacity to wind energy by year 1990 in its long-range generation plan. To reach this goal the Company's wind energy program focuses on three areas: the continuous evaluation of the wind resource, the hands-on demonstration of wind turbine generators (WTG) and an association with wind park developers. Two demonstration WTGs have been installed and operated at Edison's Wind Energy Center near Palm Springs, California: a 3 MW horizontal axis Bendix/Schachle WTG and a 500 kW vertical axis Alcoa WTG. They are part of a one to two year test program during which the performance of the WTGs will be evaluated, their system operation and environmental impact will be assessed and the design criteria of future WTGs will be identified. Edison's experience with these two WTGs is summarized and the problems encountered with the operation of the two machines are discussed.

Wehrey, M. C.

Development tests for the 2.5 megawatt Mod-2 wind turbine generator

The 2.5 megawatt MOD-2 wind turbine generator test program is discussed. The development of the 2.5 megawatt MOD-2 wind turbine generator included an extensive program of testing which encompassed verification of analytical procedures, component development, and integrated system verification. The test program was to assure achievement of the thirty year design operational life of the wind turbine system as well as to minimize costly design modifications which would otherwise have been required during on site system testing. Computer codes were modified, fatigue life of structure and dynamic components were verified, mechanical and electrical component and subsystems were functionally checked and modified where necessary to meet system specifications, and measured dynamic responses of coupled systems confirmed analytical predictions.

Andrews, J. S.

Variable speed generator application on the MOD-5A 7.3 mW wind turbine generator

This paper describes the application of a Scherbiustat type variable speed subsystem in the MOD-5A Wind Turbine Generator. As designed by General Electric Company, Advanced Energy Programs Department, under contract DEN3-153 with NASA Lewis Research Center and DOE, the MOD-5A utilizes the subsystem for both starting assistance in a motoring mode and generation in a controlled airgap torque mode. Reactive power control is also provided. The Scherbiustat type arrangement of a wound rotor machine with a cycloconverter in the rotor circuit was selected after an evaluation of variable speed technologies that followed a system evaluation of drivetrain cost and risk. The paper describes the evaluation factors considered, the results of the evaluations and summarizes operating strategy and performance simulations.

Barton, Robert S.

Method for predicting impulsive noise generated by wind turbine rotors

Large wind turbines can generate both broad band and impulsive noises. These noises can be controlled by proper choice of rotor design parameters such as rotor location with respect to the supporting tower, tower geometry and tip speed. A method was developed to calculate the impulsive noise generated when the wind turbine blade experiences air forces that are periodic functions of the rotational frequency. This phenomenon can occur when the blades operate in the wake of the support tower and the nonuniform velocity field near the ground due to wind shear. Results from this method were compared with measured sound spectra taken at locations of one to two rotor diameters from the DOE/NASA Mod-1 wind turbine. The calculated spectra generally agreed with the measured data in both the amplitude of the predominant harmonics and the roll of rate with frequency. Measured sound pressure levels far from the Mod-1 (15 rotor diameters), however, were higher than predicted. Simultaneous measurements in the near and far field indicated that the propagation effects could enhance the sound levels by more than 10 dB above that expected by spherical dispersion. These propagation effects are believed to be due to terrain and atmospheric characteristics of the Mod-1 site.

Viterna, L. A.

Sound measurements of the MOD-2 wind turbine generator

Sound measurements were made for the MOD-2 wind turbine generator for wind conditions of 7.6 to 13.4 m/sec and for output power ratings of about 1 to 2 NW. Both broad band and narrow band data wre obtained for a range of distances and azimuth angles from the machine. The rotor sound spectra are random in character and peak in the frequency ranges 30 to 50 Hz and 800 to 1300 Hz. Both peaks are predictable from experience with helicopter rotors and propellers. Results suggest that the lower frequency peak is due to the effects of inflow turbulence and the higher frequency peak is due to the interactions of the turbulent boundary layers with the trailing edges of the blades. The boundary layer related sound is the dominant component in the audible frequency range and determines the detectability of the machine. It could be detected at a distance of 1350 m in the upwind direction where the background noise was 30 dB (A) and at distances in excess of 2100 m in the downwind direction. Discrete frequency sound components associated with the power generation equipment are measurable in the direction normal to the axis of rotation but are not believed to be significant for detection or community response.

Hubbard, H. H.

A theoretical study of the upper bound of surface elevation variance in the Phillips initial stage during wind-wave generation

The resonance mechanism in the initial of wind-wave generation proposed by Phillips is a foundation of wind-wave generation theory, but a precise theoretical quantification of wave energy growth in this initial stage has not been obtained yet after more than six decades of research. In this study, we aim to address this knowledge gap by developing an analytical approach based on a novel complex analysis method to theoretically investigate the temporal evolution of the wave energy in the Phillips initial stage. We quantitatively derive and analyse the growth behaviour of the surface wave energy and obtain an analytical solution for its upper bound. Our result highlights the crucial effects of surface tension. Because the phase velocity of gravity–capillary waves has a minimal value at a critical wavenumber, gravity–capillary waves and gravity waves (which neglect surface tension) exhibit distinct resonance curve properties and wave energy growth behaviours. For gravity waves, the resonance curve extends indefinitely; for gravity–capillary waves, it either forms a finite-length curve or does not exist, depending on the wind speed. The leading-order term of the upper-bound solution of the energy of gravity waves increases linearly over time, while for gravity–capillary waves, the term increases linearly over time under strong wind conditions but remains finite under weak wind conditions. This theoretical study provides an analytical framework for the generation of wind-waves in the Phillips initial stage, which may inspire further theoretical, numerical and experimental research.

58 GEOSCIENCES