Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “waveform”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Harmonic arbitrary waveform generator

High frequency arbitrary waveforms have applications in radar, communications, medical imaging, therapy, electronic warfare, and charged particle acceleration and control. State of the art arbitrary waveform generators are limited in the frequency they can operate by the speed of the Digital to Analog converters that directly create their arbitrary waveforms. The architecture of the Harmonic Arbitrary Waveform Generator allows the phase and amplitude of the high frequency content of waveforms to be controlled without taxing the Digital to Analog converters that control them. The Harmonic Arbitrary Waveform Generator converts a high frequency input, into a precision, adjustable, high frequency arbitrary waveform.

47 OTHER INSTRUMENTATION↗

Adaptive Waveform Correlation Detectors for Arrays: Algorithms for Autonomous Calibration

Waveform correlation detectors compare a signal template with successive windows of a continuous data stream and report a detection when the correlation coefficient, or some comparable detection statistic, exceeds a specified threshold. Since correlation detectors exploit the fine structure of the full waveform, they are exquisitely sensitive when compared to power (STA/LTA) detectors. The drawback of correlation detectors is that they require complete knowledge of the signal to be detected, which limits such methods to instances of seismicity in which a very similar signal has already been observed by every station used. Such instances include earthquake swarms, aftershock sequences, repeating industrial seismicity, and many other forms of controlled explosions. The reduction in the detection threshold is even greater when the techniques are applied to arrays since stacking can be performed on the individual channel correlation traces to achieve significant array gain. In previous years we have characterized the decrease in detection threshold afforded by correlation detection across an array or network when observations of a previous event provide an adequate template for signals from subsequent events located near the calibration event. Last year we examined two related issues: (1) the size of the source region calibration footprint afforded by a master event, and (2) the use of temporally incoherent detectors designed to detect the gross envelope structure of the signal to extend the footprint. In Case 1, results from the PETROBAR-1 marine refraction profile indicated that array correlation gain was usable at inter-source separations out to one or two wavelengths. In Case 2, we found that incoherent detectors developed from a magnitude 6 event near Svalbard were successful at detecting aftershocks where correlation detectors derived from individual aftershocks were not. Incoherent detectors might provide 'seed' events for correlation detectors that then could extend detection to lower magnitudes. This year we addressed a problem long known to limit the acceptance of correlation detectors in practice: the labor intensive development of templates. For example, existing design methods cannot keep pace with rapidly unfolding aftershock sequences. We successfully built and tested an object-oriented framework (as described in our 2005 proposal) for autonomous calibration of waveform correlation detectors for an array. The framework contains a dynamic list of detectors of several types operating on a continuous array data stream. The list has permanent detectors: beam forming power (STA/LTA) detectors which serve the purpose of detecting signals not yet characterized with a waveform template. The framework also contains an arbitrary number of subspace detectors which are launched automatically using the waveforms from validated power detections as templates. The implementation is very efficient such that the computational cost of adding subspace detectors was low. The framework contains a supervisor that oversees the validation of power detections, and periodically halts the processing to revise the portfolio of detectors. The process of revision consists of collecting the waveforms from all detections, performing cross-correlations pairwise among all waveforms, clustering the detections using correlations as a distance measure, then creating a new subspace detector from each cluster. The collection of new subspace detectors replaces the existing portfolio and processing of the data stream resumes. This elaborate scheme was implemented to prevent proliferation of closely-related subspace detectors. The method performed very well on several simple sequences: 2005 'drumbeat' events observed locally at Mt. St. Helens, and the 2003 Orinda, CA aftershock sequence. Our principal test entailed detection of the aftershocks of the San Simeon earthquake using the NVAR array; in this case, the system automatically detected and categorized approximately 2/3 of the events above magnitude 2.8.

58 GEOSCIENCES↗

Lossy Compression: An Online Multi-Stage Technology for High-Fidelity Synchro- Waveform Measurements

Effective real-time monitoring and analysis of distributed grids necessitate the use of synchro-waveform measurements, which capture almost all high-frequency disturbances and transient phenomena. However, due to limitations in high-speed measurements and network bandwidth, it is challenging to transfer all high-fidelity synchro-waveforms losslessly and successfully. To cope with these challenges, a hybrid-based online multi-stage compression algorithm is proposed to significantly improve the compression efficiency for synchro-waveform measurements. Initially, the multiple discrete Wavelet transformation is deployed to deconstruct the waveform components. The delta encoding is further developed to decrease the magnitude. In conjunction with the Lempel-Ziv-Markov chain, the hybrid compression algorithm is implemented to achieve real-time compression for the synchro-waveform measurements. Moreover, an innovative error index that synergizes the time and frequency domain error and correlation is formulated to evaluate the waveform distortion. By integrating compression ratio, suitable parameters can be optimally selected. Finally, the simulation, laboratory experiments, as well as field tests across a spectrum of sampling frequencies and time intervals are conducted to substantiate the efficacy of the proposed method. Here, the outcomes demonstrated that a compression ratio of approximately 15.5 and 17.83 can be reached for 0.5 s and 1 s data under both offline and online scenarios, which equates to a substantial 93.5% to 94.39% reduction in data storage requirements.

High-fidelity synchro-waveform measurements↗

Denoising Seismic Waveforms Using a Wavelet-Transform-Based Machine-Learning Method

Seismic waveform data recorded at stations can be thought of as a superposition of the signal from a source of interest and noise from other sources. Frequency‐based filtering methods for waveform denoising do not result in desired outcomes when the targeted signal and noise occupy similar frequency bands. Recently, denoising techniques based on deep‐learning convolutional neural networks (CNNs), in which a recorded waveform is decomposed into signal and noise components, have led to improved results. These CNN methods, which use short‐time Fourier transform representations of the time series, provide signal and noise masks for the input waveform. These masks are used to create denoised signal and designaled noise waveforms, respectively. However, advancements in the field of image denoising have shown the benefits of incorporating discrete wavelet transforms (DWTs) into CNN architectures to create multilevel wavelet CNN (MWCNN) models. The MWCNN model preserves the details of the input due to the good time–frequency localization of the DWT. In this report we use a data set of over 382,000 constructed seismograms recorded by the University of Utah Seismograph Stations network to compare the performance of CNN and MWCNN‐based denoising models. Evaluation of both models on constructed test data shows that the MWCNN model outperforms the CNN model in the ability to recover the ground‐truth signal component in terms of both waveform similarity and preservation of amplitude information. Model evaluation of real‐world data shows that both the CNN and MWCNN models outperform standard band‐pass filtering (BPF; average improvement in signal‐to‐noise ratio of 9.6 and 19.7 dB, respectively, with respect to BPF). Evaluation of continuous data suggests the MWCNN denoiser can improve both signal detection capabilities and phase arrival time estimates.

58 GEOSCIENCES↗

Effects of Different Waveforms on the Performance of Active Capillary Dielectric Barrier Discharge Ionization Mass Spectrometry

Active capillary dielectric barrier discharge ionization (DBDI) is emerging as a compact, low-cost, and robust method to form intact ions of small molecules for detection in near real time by portable mass spectrometers. Here, we demonstrate that by using a 10 kHz, ~2.5 kV{sub p-p} high-voltage square-wave alternating current plasma, active capillary DBDI can consume less than 1 μW of power. In contrast, the power consumed using a sine and triangle alternating current waveform is more than two orders of magnitude higher than that for the square waveform to obtain a similar voltage for plasma generation. Moreover, the plasma obtained using a square waveform can be significantly more homogenous than that obtained using sine and triangle waveforms. Protonated dimethyl methylphosphonate (DMMP) and deprotonated perfluorooctanoic acid (PFOA) can be detected at about the same or higher abundances using square-wave DBDI mass spectrometry compared with the use of sine and triangle waveforms. By use of benzylammonium thermometer ions, the extent of internal energy deposition using square, sine, or triangle waveform excited plasmas are essentially the same at the optimum voltages for ion detection. Using an H-bridge circuit driving a transformer optimized to reduce losses, square-wave active capillary DBDI can be continuously powered for ~50 h by common 9 V-battery (PP3). .

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A seamless acquisition digital storage oscilloscope with three-dimensional waveform display

In traditional digital storage oscilloscope (DSO), sampled data need to be processed after each acquisition. During data processing, the acquisition is stopped and oscilloscope is blind to the input signal. Thus, this duration is called dead time. With the rapid development of modern electronic systems, the effect of infrequent events becomes significant. To capture these occasional events in shorter time, dead time in traditional DSO that causes the loss of measured signal needs to be reduced or even eliminated. In this paper, a seamless acquisition oscilloscope without dead time is proposed. In this oscilloscope, three-dimensional waveform mapping (TWM) technique, which converts sampled data to displayed waveform, is proposed. With this technique, not only the process speed is improved, but also the probability information of waveform is displayed with different brightness. Thus, a three-dimensional waveform is shown to the user. To reduce processing time further, parallel TWM which processes several sampled points simultaneously, and dual-port random access memory based pipelining technique which can process one sampling point in one clock period are proposed. Furthermore, two DDR3 (Double-Data-Rate Three Synchronous Dynamic Random Access Memory) are used for storing sampled data alternately, thus the acquisition can continue during data processing. Therefore, the dead time of DSO is eliminated. In addition, a double-pulse test method is adopted to test the waveform capturing rate (WCR) of the oscilloscope and a combined pulse test method is employed to evaluate the oscilloscope's capture ability comprehensively. The experiment results show that the WCR of the designed oscilloscope is 6 250 000 wfms/s (waveforms per second), the highest value in all existing oscilloscopes. The testing results also prove that there is no dead time in our oscilloscope, thus realizing the seamless acquisition.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A method to fuse multiphysics waveforms and improve predictive explosion detection: theory, experiment and performance

Natural and human-made sources of transient energy often emit multiple geophysical signatures that include mechanical and electromagnetic waveforms. We present a constructive method to fuse and evaluate statistics that we derive from such multiphysics waveforms that improves our capability to detect small, near-ground explosions over similar methods that consume single signature waveforms. Our method advances Fisher's Combined Probability Test (Fisher's Method) to operate under both hypotheses of a binary test on noisy data and provide researchers with the density functions required to forecast the ability of Fisher's Method to screen fused explosion signatures from noise. We apply this method against 12 d, multisignature explosion and noise records to show (1) that a fused multiphysics waveform statistic that combines radio, acoustic and seismic waveform data can identify explosions roughly 0.8 magnitude units lower than an acoustic emission, STA/LTA detector for the same detection probability and (2) that we can quantitatively predict how this fused, multiphysics statistic performs with Fisher's Method. Our work thereby offers a baseline method for predictive waveform fusion that supports multiphenomenological explosion monitoring (multiPEM) and is applicable to any binary testing problem in observational geophysics.

58 GEOSCIENCES↗

High-accuracy waveforms for black hole-neutron star systems with spinning black holes

The availability of accurate numerical waveforms is an important requirement for the creation and calibration of reliable waveform models for gravitational wave astrophysics. For black hole-neutron star binaries, very few accurate waveforms are however publicly available. Most recent models are calibrated to a large number of older simulations with good parameter space coverage for low-spin non-precessing binaries but limited accuracy, and a much smaller number of longer, more recent simulations limited to non-spinning black holes. In this paper, we present long, accurate numerical waveforms for three new systems that include rapidly spinning black holes, and one precessing configuration. Here, we study in detail the accuracy of the simulations, and in particular perform for the first time in the context of BHNS binaries a detailed comparison of waveform extrapolation methods to the results of Cauchy Characteristic Extraction. The new waveforms have <0.1rad phase errors during inspiral, rising to ~(0.2-0.4)rad errors at merger, and ≲1% error in their amplitude. We compute the faithfulness of recent analytical models to these numerical results, and find that models specifically designed for BHNS binaries perform well (F>0.99) for binaries seen face-on. For edge-on observations, particularly for precessing systems, disagreements between models and simulations increase, and models that include precession and/or higher-order modes start to perform better than BHNS models that currently lack these features.

79 ASTRONOMY AND ASTROPHYSICS↗

Model waveform accuracy standards for gravitational wave data analysis

Model waveforms are used in gravitational wave data analysis to detect and then to measure the properties of a source by matching the model waveforms to the signal from a detector. This paper derives accuracy standards for model waveforms which are sufficient to ensure that these data analysis applications are capable of extracting the full scientific content of the data, but without demanding excessive accuracy that would place undue burdens on the model waveform simulation community. These accuracy standards are intended primarily for broadband model waveforms produced by numerical simulations, but the standards are quite general and apply equally to such waveforms produced by analytical or hybrid analytical-numerical methods.

79 ASTRONOMY AND ASTROPHYSICS↗

High-accuracy waveforms for binary black hole inspiral, merger, and ringdown

The first spectral numerical simulations of 16 orbits, merger, and ringdown of an equal-mass nonspinning binary black hole system are presented. Gravitational waveforms from these simulations have accumulated numerical phase errors through ringdown of < or approx. 0.1 radian when measured from the beginning of the simulation, and < or approx. 0.02 radian when waveforms are time and phase shifted to agree at the peak amplitude. The waveform seen by an observer at infinity is determined from waveforms computed at finite radii by an extrapolation process accurate to < or approx. 0.01 radian in phase. The phase difference between this waveform at infinity and the waveform measured at a finite radius of r=100M is about half a radian. The ratio of final mass to initial mass is M{sub f}/M=0.951 62{+-}0.000 02, and the final black hole spin is S{sub f}/M{sub f}{sup 2}=0.686 46{+-}0.000 04.

39↗

Accuracy and effectualness of closed-form, frequency-domain waveforms for nonspinning black hole binaries

The coalescences of binary black hole systems, here taken to be nonspinning, are among the most promising sources for gravitational wave (GW) ground-based detectors, such as LIGO and Virgo. To detect the GW signals emitted by binary black holes and measure the parameters of the source, one needs to have in hand a bank of GW templates that are both effectual (for detection) and accurate (for measurement). We study the effectualness and the accuracy of the two types of parametrized banks of templates that are directly defined in the frequency domain by means of closed-form expressions, namely, 'post-Newtonian' (PN) and 'phenomenological' models. In the absence of knowledge of the (continuous family of) exact waveforms, our study assumes as fiducial, target waveforms the ones generated by the most accurate version of the effective-one-body formalism, calibrated upon a few high-accuracy numerical-relativity (NR) waveforms. We find that, for initial GW detectors the use, at each point of parameter space, of the best closed-form template (among PN and phenomenological models) leads to an effectualness >97% over the entire mass range and >99% in an important fraction of parameter space; however, when considering advanced detectors, both of the closed-form frequency-domain models fail to be effectual enough in significant domains of the two-dimensional [total mass and mass ratio] parameter space. Moreover, we find that, for both initial and advanced detectors, the two closed-form frequency-domain models fail to satisfy the minimal required accuracy standard in a very large domain of the two-dimensional parameter space. In addition, a side result of our study is the determination, as a function of the mass ratio, of the maximum frequency at which a frequency-domain PN waveform can be 'joined' onto a NR-calibrated effective-one-body waveform without undue loss of accuracy. In the case of mass ratios larger than 4 ratio 1 this maximum frequency occurs well before the last stable orbit, leaving probably too many orbital cycles to be covered by current NR techniques if one wanted to construct accurate-enough hybrid PN-NR waveforms. This problem will, however, be probably greatly alleviated, or even solved, by using the effective-one-body formalism instead of PN theory.

79 ASTRONOMY AND ASTROPHYSICS↗

Mergers of black-hole binaries with aligned spins: Waveform characteristics

We conduct a descriptive analysis of the multipolar structure of gravitational-radiation waveforms from equal-mass aligned-spin mergers, following an approach first presented in the complementary context of nonspinning black holes of varying mass ratio [J. G. Baker et al., Phys. Rev. D 78, 044046 (2008).]. We find that, as with the nonspinning mergers, the dominant waveform mode phases evolve together in lock-step through inspiral and merger, supporting the previous waveform description in terms of an adiabatically rigid rotator driving gravitational-wave emission--an implicit rotating source. We further apply the late-time merger-ringdown model for the rotational frequency introduced in [J. G. Baker et al., Phys. Rev. D 78, 044046 (2008).], along with an improved amplitude model appropriate for the dominant (2, {+-}2) modes. This provides a quantitative description of the merger-ringdown waveforms, and suggests that the major features of these waveforms can be described with reference only to the intrinsic parameters associated with the state of the final black hole formed in the merger. We provide an explicit model for the merger-ringdown radiation, and demonstrate that this model agrees to fitting factors better than 95% with the original numerical waveforms for system masses above {approx}150M{sub {center_dot}}. This model may be directly applicable to gravitational-wave detection of intermediate-mass black-hole mergers.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Examining the Performance of MIL-STD-188-110D Waveform 0 Against FBMC-SS Over Skywave HF Channels

This paper provides a comprehensive performance comparison between a current robust military waveform; namely, MIL-STD-188-110D, Waveform 0, and a filter bank multicarrier spread-spectrum (FBMC-SS) waveform proposed for communications through ionospheric/skywave HF channels. Waveform 0 is effectively a direct sequence spread spectrum waveform that uses Walsh multi-codes to enhance the information transmission rate. It may thus be referred to as Walsh-DSSS. FBMC-SS, on the other hand, makes use of filter banks to provide excellent performance when the received signal is subject to partial band interference. Successful application of FBMC-SS for communications across skywave HF channels has been previously demonstrated, both theoretically and through experimental work. However, very little has been done to contrast FBMC-SS against Walsh-DSSS. The goal of this paper is to first add new features to FBMC-SS to bring it on par with Walsh-DSSS. These features include: (i), introduction of multi-codes that achieve a comparable (or better) data rate to Walsh-DSSS; and (ii), addition of a scrambling step applied to the multi-codes to make the receiver detection robust against widely spread multipaths. With this established, in the second part of the paper, we examine the performance of the developed FBMC-SS against Walsh-DSSS when both are applied for communications across skywave HF channels. The two waveforms are compared both through a theoretical study and through experimental works across several skywave channels ranging from hundreds to thousands of kilometers.

42 ENGINEERING↗

Improved Regional Moment Tensor Inversion for Moderately Large Earthquakes in the Western United States Using a 3D Earth Model Based on Full Waveform Tomography

The nature of seismic sources for moderately large (moment magnitude, M w 5.0–6.5) events are commonly characterized by their moment tensor (MT) solutions and obtained by inversion of regional distance (200–1600 km) long‐period (20–50 s) waveforms. Regional MT estimates are often calculated from average plane‐layered, one‐dimensional (1D) velocity models. However, 1D model calculations can produce misfits in the arrival times and waveform shapes that introduce errors, particularly at longer distances or for shorter periods, which are necessary for analyzing lower magnitude events. Approximate Earth models (e.g., 1D) representing broad areas may be inadequate, particularly in the crust and uppermost mantle of tectonically complex regions. In this study, we show how a three‐dimensional (3D) Earth model obtained from full waveform inversion tomography can improve waveform fits and decrease phase errors. We developed a platform and workflow to perform routine 3D MT inversions and inverted MTs for 25 earthquakes in the western United States and seven nuclear explosions using an average 1D and a recent 3D Earth model, WUS256 (Rodgers et al., 2022). Using the 3D model improves waveform fits (variance reduction and phase time shifts) compared with the 1D model, and the 3D MT solutions are stable across large distances. This study shows that 3D models obtained from full waveform tomography can improve MTs and source characterization especially at far regional distances (>800 km).

Geosciences↗

Automatic Waveform Quality Control for Surface Waves Using Machine Learning

Surface-wave seismograms are widely used by researchers to study Earth’s interior and earthquakes. To extract information reliably and robustly from a suite of surface waveforms, the signals require quality control screening to reduce artifacts from signal complexity and noise. This process has usually been completed by human experts labeling each waveform visually, which is time consuming and tedious for large data sets. We explore automated approaches to improve the efficiency of waveform quality control processing by investigating logistic regression, support vector machines, K-nearest neighbors, random forests (RF), and artificial neural networks (ANN) algorithms. To speed up signal quality assessment, we trained these five machine learning (ML) methods using nearly 400,000 human-labeled waveforms. The ANN and RF models outperformed other algorithms and achieved a test accuracy of 92%. We evaluated these two best-performing models using seismic events from geographic regions not used for training. The results show that the two trained models agree with labels from human analysts but required only 0.4% of the time. Although the original (human) quality assignments assessed general waveform signal-to-noise, the ANN or RF labels can help facilitate detailed waveform analysis. Our investigations demonstrate the capability of the automated processing using these two ML models to reduce outliers in surface-wave-related measurements without human quality control screening.

58 GEOSCIENCES↗

NORSAR Final Scientific Report Adaptive Waveform Correlation Detectors for Arrays: Algorithms for Autonomous Calibration

Correlation detection is a relatively new approach in seismology that offers significant advantages in increased sensitivity and event screening over standard energy detection algorithms. The basic concept is that a representative event waveform is used as a template (i.e. matched filter) that is correlated against a continuous, possibly multichannel, data stream to detect new occurrences of that same signal. These algorithms are therefore effective at detecting repeating events, such as explosions and aftershocks at a specific location. This final report summarizes the results of a three-year cooperative project undertaken by NORSAR and Lawrence Livermore National Laboratory. The overall objective has been to develop and test a new advanced, automatic approach to seismic detection using waveform correlation. The principal goal is to develop an adaptive processing algorithm. By this we mean that the detector is initiated using a basic set of reference ('master') events to be used in the correlation process, and then an automatic algorithm is applied successively to provide improved performance by extending the set of master events selectively and strategically. These additional master events are generated by an independent, conventional detection system. A periodic analyst review will then be applied to verify the performance and, if necessary, adjust and consolidate the master event set. A primary focus of this project has been the application of waveform correlation techniques to seismic arrays. The basic procedure is to perform correlation on the individual channels, and then stack the correlation traces using zero-delay beam forming. Array methods such as frequency-wavenumber analysis can be applied to this set of correlation traces to help guarantee the validity of detections and lower the detection threshold. In principle, the deployment of correlation detectors against seismically active regions could involve very large numbers of very specific detectors. To meet this challenge, we have examined two strategies: (1) use of subspace detectors, a multi-dimensional extension of correlators, which allow representation and detection of signals exhibiting some degree of variation; and (2) autonomous calibration of many subspace and correlation detectors in an adaptive detection framework, subject to analyst review. Because correlation detectors are relatively new to seismology, a significant amount of research on how to tune these detectors has been needed to address later calibration efforts that will arise as they are adopted for operational use. We have approached these challenges by carrying out a number of case studies, encompassing various monitoring scenarios such as earthquake aftershock sequences and swarms, recurring mining explosions, other types of explosions, and rockbursts. We have studied several different geographical regions (the European Arctic, Central Asia, and the western United States). We have drawn on available Ground Truth data in assessing the results of the various processing schemes. In all cases, we have benefited from the high-quality seismic arrays or networks available in these regions, and we have thus been able to evaluate the performance of array-based correlation processing under a variety of conditions. The main results of the project are summarized as follows: (1) Array-based waveform correlation has been demonstrated to lower significantly detection thresholds in comparison with standard single-channel waveform correlation. (2) Frequency-wavenumber analysis of the correlation traces on a small-aperture array provides an effective method for screening out a certain category of false alarms, and can therefore be used to improve detector sensitivity by lowering the threshold for automatic array detection. (3) We have developed and tested a framework for autonomous correlation detection. The framework comprises a set of conventional (STA/LTA) detectors on a collection of array beams, augmented by correlation and subspace detectors. The detectors are applied in parallel. (4) We have experimentally tested the processing of a large aftershock sequence using various transformations of the signals from the main event to construct what we denote an incoherent correlation detector or characteristic function correlation detector. (5) An important application of multi-channel waveform correlation is to identify instances of erroneous instrumental timing. We provide examples of detected timing errors on single channels of an array, as well as on a remote three-component station.

58 GEOSCIENCES↗

Exploring the limits of waveform correlation event detection as applied to three earthquake aftershock sequences.

Swarms of earthquakes and/or aftershock sequences can dramatically increase the level of seismicity in a region for a period of time lasting from days to months, depending on the swarm or sequence. Such occurrences can provide a large amount of useful information to seismologists. For those who monitor seismic events for possible nuclear explosions, however, these swarms/sequences are a nuisance. In an explosion monitoring system, each event must be treated as a possible nuclear test until it can be proven, to a high degree of confidence, not to be. Seismic events recorded by the same station with highly correlated waveforms almost certainly have a similar location and source type, so clusters of events within a swarm can quickly be identified as earthquakes. We have developed a number of tools that can be used to exploit the high degree of waveform similarity expected to be associated with swarms/sequences. Dendro Tool measures correlations between known events. The Waveform Correlation Detector is intended to act as a detector, finding events in raw data which correlate with known events. The Self Scanner is used to find all correlated segments within a raw data steam and does not require an event library. All three techniques together provide an opportunity to study the similarities of events in an aftershock sequence in different ways. To comprehensively characterize the benefits and limits of waveform correlation techniques, we studied 3 aftershock sequences, using our 3 tools, at multiple stations. We explored the effects of station distance and event magnitudes on correlation results. Lastly, we show the reduction in detection threshold and analyst workload offered by waveform correlation techniques compared to STA/LTA based detection. We analyzed 4 days of data from each aftershock sequence using all three methods. Most known events clustered in a similar manner across the toolsets. Up to 25% of catalogued events were found to be a member of a cluster. In addition, the Waveform Correlation Detector and Self Scanner identified significant numbers of new events that were not in either the EDR or regional catalogs, showing a lowering of the detection threshold. We extended our analysis to study the effect of distance on correlation results by applying the analysis tools to multiple stations along a transect of nearly constant azimuth when possible. We expected the number of events found via correlation would drop off as roughly 1/r2, where r is the distance from mainshock to station. However, we found that regional geological conditions influenced the performance of a given station more than distance. For example, for one sequence we clustered 25% of events at the nearest station to the mainshock (34 km), while our performance dropped to 2% at a station 550 km distant. However, we matched our best performance (25% clustering) at a station 198 km distant.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Optimal Multicarrier Phase-Coded Waveform Design for Detection of Extended Targets

We design a parametric multicarrier phase-coded (MCPC) waveform that achieves the optimal performance in detecting an extended target in the presence of signal-dependent interference. Traditional waveform design techniques provide only the optimal energy spectral density of the transmit waveform and suffer a performance loss in the synthesis process of the time-domain signal. Therefore, we opt for directly designing an MCPC waveform in terms of its time-frequency codes to obtain the optimal detection performance. First, we describe the modeling assumptions considering an extended target buried within the signal-dependent clutter with known power spectral density, and deduce the performance characteristics of the optimal detector. Then, considering an MCPC signal transmission, we express the detection characteristics in terms of the phase-codes of the MCPC waveform and propose to optimally design the MCPC signal by maximizing the detection probability. Our numerical results demonstrate that the designed MCPC signal attains the optimal detection performance and requires a lesser computational time than the other parametric waveform design approach.

Sen, Satyabrata↗