Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “water resources hydrodynamics”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

41 records · Page 3

Influences on Discharge Partitioning on a Large River Delta: Case Study of the Mississippi-Atchafalaya Diversion, 1926-1950

The modern Mississippi River (M.R.) Delta is plumbed by the Mississippi and Atchafalaya rivers, setting water and sediment dispersal pathways for Earth’s fifth-largest river system. The Atchafalaya River’s (A.R.) partial annexation of discharge from the M.R., particularly between 1926 and 1950, prompted warnings of a rapid river avulsion and the construction of the Old River Control Structure to regulate flow. Natural and anthropogenic causes of this discharge annexation are difficult to disentangle. Here, we develop and validate a hydrodynamic model of flow partitioning through the historic channel network. We then isolate how several key changes to the system affected discharge partitioning and stage at the A.R.-M.R. diversion. Simulations show that erosion of the upper A.R. can account for 73% of the water discharge increase. Dredging in the lower A.R. between 1932 and 1950 can account for 35% of the water discharge increase, and was also an important control on shear stress distribution. The lower M.R. was slightly erosional during this period, and therefore hindered the A.R. discharge increase. Significant lacustrine delta deposition in A.R. had little effect on partitioning. These findings highlight the importance of A.R. enlargement processes on avulsion dynamics at this site. Given the essential nature of this river junction to the society, transportation, and commerce of the United States, improved attribution of discharge increases may lead to future management strategies that are broadly impactful.

54 ENVIRONMENTAL SCIENCES↗

Thermocatalytic Heat Pipes for Geothermal Resource Recovery

Heat pipes are an important technology that allow orders of magnitude faster heat transfer than simple conduction. However, operating principles in heat pipes place fundamental bounds on their performance (critical heat flux and efficiency). Conventional heat pipe functionality is inherently tied to vaporization and condensation of the working fluid charged in the heat pipe. These fluids each have different operating temperature ranges based on the capillary, entrainment, sonic, and boiling limits of the heat pipe design. These limits, typically the capillary limit, dictate the maximum heat flux a heat pipe can carry, and most importantly for geothermal systems, the distance over which the pipes can operate (100 to 200 m maximum under optimum conditions). A thermocatalytic heat pipe breaks the inherent limitations of phase change thermo- and hydrodynamics and can transform heat pipe technology as a potentially more efficient means of extracting heat from a geothermal resource. The thermocatalytic heat pipe uses a working fluid to transport both sensible and chemical heat. An endothermic chemical reaction at depth removes heat from the reservoir and produces reactive intermediates, which are transported to the surface and used to run a reverse exothermic reaction that releases heat for use in power generation or other useful purposes. This technology offers two distinct advantages over conventional geothermal heat recovery technologies: (1) lower heat loss to the rock outside of the geothermal reservoir, and (2) higher heat transfer rates to the well field within the geothermal reservoir. Both advantages offer opportunity to reduce risks and lower costs of geothermal energy recovery. In this report, we discuss an initial effort to assess the efficacy and limitations of this technology for extracting heat from both porous/permeable and nominally impermeable geothermal reservoirs. Numerical simulation capabilities of the STOMP-GT code were enhanced to enable simulations of thermochemical heat pipes traversing geothermal reservoirs. An array of potential thermochemical reaction systems was evaluated and screened. Of these, an ethanol dehydration reaction was most promising in the vapor-liquid reaction set. A solid-phase dehydration reaction (CuSO4·5H2O) showed the highest reaction enthalpy per unit volume but would require development of a nonaqueous carrier fluid to implement it in a heat pipe. Subsurface reservoir simulations predicted long-term performance of the heat pipes for each geothermal reservoir type. The performance of U-shaped wells and coaxial wells was evaluated for a suite of reactions for both hydrothermal and hot dry rock reservoirs and was compared with a baseline case of simply pumping water through the wells. The heat pipe technology was additionally evaluated for an enhanced geothermal system (EGS) with an injection borehole, production borehole, and intervening hydraulically conductive fracture. All reservoir types showed significant improvement in heat recovered over a 20-year operating period ranging from a 1.8X increase for the hot dry rock case to more than 2.5X more energy recovered for the EGS case.

15 GEOTHERMAL ENERGY↗

rHealth One Demonstration Aboard ISS: A Microfluidic Bioanalyzer Based on Sheath/Hydrodynamic Focusing Flow Cytometry

The Exploration Medical Capability (ExMC) element aims to provide astronauts with the means for their own health monitoring, diagnosis, and treatment during exploration missions. As space flight ventures further from earth, the need for autonomous medical care increases under greater constraints on size, mass, and resources. One pillar for diagnosis that crew would be separated from is laboratory analysis. Even now on ISS, blood samples must be collected and returned to earth for testing. In response, ExMC is assessing how assays for hematology, bone health, radiation exposure etc. could be addressed through commercial-off-the-shelf (COTS) and Small Business Innovation Research (SBIR) funded bioanalyzers that are miniaturizing lab technology. Since missions will reach distances where there are no timely replacements, validation on the International Space Station (ISS) is a necessary part of that assessment. In partnership with NASA Johnson Space Center (JSC) Immunology Lab and the Research Operations and Integration (ROI) element, ExMC conducted a technology demonstration on ISS of the rHEALTH ONE, a flow cytometry based bioanalyzer, to assess future devices based on this design. In flow cytometry, there are predominantly three ways to focus the cells (or particles) into a single file stream: hydrodynamic focusing, microcapillary, and acoustic focusing. The rHEALTH ONE utilizes the commercial standard, sheath-based hydrodynamic focusing. rHEALTH itself represents both a company and a suite of medical tools NASA has funded through SBIR grants towards the development of a promising diagnosis instrument for exploration missions. rHEALTH ONE is the interim version of the technology, functional as a benchtop analyzer and test bed for the next generation of rHEALTH in development. Several modifications were made to the rHEALTH ONE analyzer for operation in microgravity. For function, fluid management was key. A sheath-based analyzer uses sheath fluid to flow the sample, cleaning fluid to prevent biological contamination, and a reservoir to collect the liquid waste. The rHEALTH ONE analyzer uses bottles dependent on gravity to separate the air and liquid pathways and keep the liquids contained. It uses only 1 psig of air pressure to directly push the liquid through the device, requiring little-to-no resistance at inlet and outlet. A microtubing assembly with self-sealing luer connectors was designed – featuring 0.014 mm thick durable medical balloons to hold water inside the supply bottles – to create safe containment and easy access for the crew while maintaining the analyzer’s function. For safety, copper tape was added to the interior of the plastic housing to reduce electromagnetic interference, fluid and electrical connections were secured against vibration and leaks, and gaps were further sealed to ensure containment of the optical block and lasers. Water as the sheath and cleaning fluid and TOX 0 samples were used to reduce the biohazard risk to the crew. In May 2022, European Space Agency astronaut Samantha Cristoforetti demonstrated the rHEALTH ONE aboard ISS for its sample loading, flow cytometry, and data collection capability in microgravity. The JSC Immunology Lab provided flow cytometry expertise, designed the sample test protocol, and manufactured and benchmarked the flight samples on a ‘gold-standard’ flow cytometer. The analyzer was primed with water, purged of air, and four calibration solutions of polystyrene microparticles were tested to characterize its performance. Tightly controlled procedures and excellent execution prevented air bubble interference during air/water separation, fluid transfer, sample mixing and loading. Data showed a slight increase in signal noise on 3 of 5 channels and an anomaly of fluorophores migrating in one sample (confirmed by JSC post-flight). Flight results correctly detected the change in sample, matched the analyzer’s ground performance, and were consistent with the gold-standard’s ground results. Although areas were noted for improvement, these outcomes signified complete mission success.

R. S. Miller↗

Sediment transport and morphodynamic changes due to upstream variation and sea level rise on the Western Mekong Delta, Vietnam

The hydrological and morphological dynamics across the Vietnam Mekong Delta (VMD) coastline are increasingly shaped by human interventions and climate change, affecting the sustainability of socio-economic environments. This study employs the TELEMAC-MASCARET modeling system (TELEMAC-2D, TOMAWAC, and SISYPHE modules) to simulate hydrodynamics, sediment transport, and morphological changes for a 10-year period under baseline (SC1) and future climate (SC2) scenarios, considering wave climatology of Northeast (NEM) and Southwest monsoons (SWM). The results of sedimentation and erosion were analyzed across five key coastal zones from Ca Mau Cape (KV1) to Ha Tien (KV5). Model results highlight distinct seasonal patterns of sediment redistribution shaped by monsoonal flows, wave action, and seabed morphology. During the NEM, sediment deposition is concentrated near estuarine zones, while the SWM favors offshore sediment accumulation due to perpendicular wave actions, and shallow, gently sloping bathymetry that dissipates wave energy. Coastal erosion predominantly occurs at convex shoreline features subjected to stronger coastal currents, particularly in fine-grained sediment areas. Under future sea level rise and land subsidence scenarios, reduced flow velocities lead to lower bottom shear stress, promoting deposition and mitigating erosion problems despite increased wave energy. Besides that, sediment transport analyses across 14 cross-sections (C-S) reveal a southward trend during the NEM and a northward reversal during the SWM, with upstream sediment reductions primarily influencing near-estuarine zones and exerting minimal impact beyond the mid-coastal regions. Furthermore, these findings advance the understanding of sediment redistribution processes under climate change and seasonal change, and provide a scientific basis for adaptive coastal management and sustainable development.

Climate change↗

ISS Technology Demonstrations for Future Spaceflight Medical Systems

Throughout the history of human spaceflight, crewmembers have experienced various in-flight medical conditions including illness and injury. Planned missions to the Moon and Mars will require capabilities to maintain the health of future space travelers. Mass, power, and volume available in the vehicles and habitats for these missions will be severely constrained; resupply of resources will be limited or non-existent, as will opportunities for evacuation to Earth. Furthermore, ground-based support will be hampered by communication latencies and blackouts. These vehicle and mission constraints will necessitate a medical system that has been efficiently planned, providing on-board procedural guidance in addition to a variety of medical devices and consumable resources. Medical capabilities required for the diagnosis and treatment of potential medical conditions during future spaceflight missions may include real-time health monitoring, medical imaging, and biomarker analyses ( e.g., blood or urine). Terrestrial medicine shares these needs, thus many of these medical capabilities could likely be satisfied by Commercial-Off-The-Shelf (COTS) devices and methodologies; however, in some cases the unique space environment and increased mission duration will drive the need to modify technologies and the way care is provided. NASA’s Human Research Program (HRP) Exploration Medical Capability (ExMC) Element and Mars Campaign Office’s Exploration Medical Integrated Product Team (XMIPT) are working together to decrease medical risk during exploration missions. Flight-tested medical diagnostic and treatment technologies are necessary to effectively manage medical conditions relevant to exploration missions while meeting vehicle constraints, integrating with medical decision-support tools, and enabling increasingly Earth-independent operations. Several projects have leveraged the ISS as a testbed for exploration, including 1) i n- situ blood analysis, 2) medical inventory, 3) intravenous fluid generation, and 4) autonomous medical procedure guidance. Management of several in-flight medical conditions, such as bacterial and viral infections and acute radiation syndrome, is dramatically improved with ability to assess blood cell populations, electrolytes, and metabolites. I n December 2020 and January 2021 ExMC performed an ISS technology demonstration (Tech Demo) of the HemoCue® WBC DIFF analyzer (HemoCue, Brea, CA), a COTS device that was modified to enable functionality in a spaceflight environment. This Tech Demo marked the first time that hematology measurements were successfully performed real-time in microgravity. Also modified and demonstrated was the reusable Handheld Electrolytes and Lab Technology for Humans (rHEALTH) ONE analyzer (rHEALTH, Bedford, MA), which uses flow cytometry and sheath-based hydrodynamic focusing methodologies. The rHEALTH ONE ISS Tech Demo in May 2022 demonstrated test results obtained in-flight matched those on the ground. NASA currently relies on crew self-reporting to manage and maintain medical inventory on ISS.The ability to maintain an accurate inventory becomes more critical during long duration missions since the crew will need to be increasingly autonomous in finding and utilizing medical items, including those scenarios when alternative treatments need to be considered due to limited or no resupply. HRP’s Medical Consumables Tracking (MCT) project was developed by ZIN Technologies, Inc. (Cleveland, OH), and demonstrated real-time tracking of medical supplies aboard the ISS between December 2016 and July 2018. The MCT system design utilized Radio Frequency Identification Device (RFID) technology to perform automated inventory and was installed in the Crew Health Care System (CHeCS) Resupply Stowage Rack (RSR). The challenge of limited shelf life, exacerbated by the lack of resupply opportunities, affects a plethora of medical system components including consumables, pharmaceuticals, and intravenous (IV) fluid. In 2010, ExMC funded ZIN Technologies, Inc. (Cleveland, OH), to develop the Intravenous Fluid Generation (IVGEN) system. IV fluids were successfully generated with IVGEN using the potable water supply on ISS during ISS Expedition 23. The XMIPT is in the process of developing a miniaturized version of the original IVGEN hardware for a future Tech Demo aboard the ISS. Current ISS medical operations rely heavily on preflight training and real-time remote guidance, both of which become impractical or impossible for exploration missions. The primary goal of the Autonomous Medical Officer Support (AMOS) Software Tech Demos on ISS was to confirm telemedical proof-of-concept for autonomous medical imaging in an operational setting. This novel software tool shifts emphasis from preflight training and real-time remote guidance to in-flight just-in-time instruction, a new and necessary paradigm for crew medical autonomy. AMOS introduces a novel, streamlined skill management concept for exploration missions featuring comprehensive training and guidance modules for ultrasound examinations using the ISS Ultrasound 2 (a modified GE Vivid-q™; General Electric HealthCare, Chicago, IL). With no prior crew training or remote guidance, two Tech Demos on the ISS (April 2020 and June 2022) resulted in high quality, clinically useful image sets. We will provide a review of historical, current, and planned medical devices and technologies considered for inclusion within future spaceflight medical systems and summarize hardware development activities and medical device tech demos conducted on the ISS.

Astronaut health and performance↗