Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “water distribution system”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Novel Modular Treatment System for Distributed Energy Recovery and Water Reclamation from Industrial Wastewaters

The overarching goal of this work was to accelerate the commercialization of a distributed, modular, agile treatment technology - the Modular Encapsulated Two-stage Anaerobic Biological (METAB) system - by advancing it to pilot-scale. Specifically, the METAB system was developed to treat high strength wastewater (5,000-35,000 mg/L chemical oxygen demand (COD)), produce hydrogen (H2) and methane (CH4), and achieve these outcomes without a membrane for retention of microorganisms.

42 ENGINEERING↗

Seeding Advanced Treated Wastewater for Purposes of Direct Potable Reuse

Direct potable reuse (DPR) is a promising solution to address water scarcity. However, a better understanding of how introducing advanced treated water (ATW) affects microbial communities present in distribution systems is needed. Here, in this study, we measured changes to the microbial water quality in simulated distribution systems that were conditioned using treated, unimpaired surface water (SW) and then transitioned to ATW. In addition, we investigated whether adding a biological filtration step would seed the microbial community of the ATW and whether the influence would persist in the simulated distribution systems. We found that the bulk water in the ATW-fed distribution systems had lower cell counts and ATP concentrations and a distinct microbial community (based on 16S amplicon sequencing) compared to the SW-fed or the seeded ATW-fed systems. However, biofilm community composition and biomass remained consistent regardless of the feedwater. Increased microbial biomass and diversity were present in the seeded ATW, with several amplicon sequence variants identified as being introduced by the biological filter. Our results suggest that directly introducing ATW to distribution systems could disturb the existing microbial community. Preparing ATW for distribution via biological filtration may deliver more predictable and stable microbial water quality than introducing unseeded ATW.

16S↗

A Comprehensive Scheduling Framework using SP-ADMM for Residential Demand Response with Weather and Consumer Uncertainties

This paper presents a comprehensive scheduling framework for residential demand response (DR) programs considering both the day-ahead and real-time electricity markets. In the first stage, residential customers determine the operating status of their responsive devices such as heating, ventilation, and air conditioning (HVAC) systems and electric water heaters (EWHs), while the distribution system operator (DSO) computes the amount of electricity to be purchased in the day-ahead electricity market. In the second stage, the DSO purchases insufficient (or sells surplus) electricity in the real-time electricity market to maintain the supply-demand balance. Due to its computational complexity and data privacy issues, the proposed model cannot be directly solved in a centralized manner, especially with a large number of uncertain scenarios. Therefore, this paper proposes a combination of stochastic programming (SP) and the alternating direction method of multipliers (ADMM) algorithm, called SP-ADMM, to decompose the original model and then solve each sub-problem in a distributed manner while considering multiple uncertain scenarios. The simulation study is performed on the IEEE 33-bus system including 121 residential houses. Here, the results demonstrate the effectiveness of the proposed approach for large-scale residential DR applications under weather and consumer uncertainties.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Enabling residential heating decarbonization through hydronic low-temperature thermal distribution using forced-air assistive devices

Space heating represents approximately one-tenth of the United States’ energy use and has a breadth of potential for emission reduction. An element of space heating, hydronic heat distribution methods, use water supply temperatures up to 82.2 °C (180 °F). However, this operating temperature can be incompatible with high-efficiency heat generation systems, which typically provide heating temperatures of up to 60 °C (140 °F). In this work, a low-cost retrofit solution is developed using experimentally validated computational tools by incorporating an airflow distributor that preferentially directs the airflow from a fan to enhance heat transfer over the finned-tube heat exchanger found in conventional baseboards. The same heat output of traditional baseboard heat distribution systems operating at higher water supply temperatures (71.1 – 82.2 °C) can also be achieved at lower temperatures (≤60 °C). Specifically, results indicate that the technology can produce more than a 46.7% improvement in the heat transfer output at temperatures as low as 60 °C (140 °F), effectively matching the same output range achieved by 71.1 – 82.2 °C (160–180 °F) water supply temperatures. An important benefit of this solution is that it utilizes the existing infrastructure as opposed to requiring the replacement of the entire distribution system. Additionally, this technology enables existing building infrastructure to be coupled with newer, high-efficiency heating systems such as condensing boilers, solar-thermal systems, and geothermal/air-to-water heat pumps that may produce lower water supply temperatures (60 °C). A geospatially resolved techno-economic and environmental analysis is completed and presented to further understand the equivalent carbon footprint of enabling higher efficiency heat generation systems with the improved efficiency heat distribution system disclosed. Using 2021 grid-average emission factors, an emission reduction of up to a 67.5% decrease (2658 kgCO 2 /yr) for a single-family home, depending on state and climate region, could be realized by replacing a traditional natural gas-fired boiler with an air-to-water heat pump coupled to the same high-temperature heat distribution system along with the low-cost retrofit solution. A complete CO 2 emission reduction of 6688 kgCO 2 /yr, depending on state and climate region, could be realized if all electricity is further renewably sourced. Thus, this study provides a possible pathway towards enabling the reduction of operational emissions in space heating.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Irrigation system

A gravity irrigation system includes a distribution piping having apertures to distribute water to a field, and a valve located upstream of the distribution piping. The valve limits a pressure of the water being delivered to the distribution piping. The system also includes a sump to receive the water at a lowest elevation of the field, a depth sensor disposed within the sump, and a return pump disposed at least partially within the sump to move the water to an elevated portion of the field. The system also includes a motor to drive the return pump, and a power source coupled to a variable frequency drive that powers the motor and controls a motor speed proportionately to an indication of the depth sensor. The system also includes a transfer piping to bring the water from the return pump to a check valve and to the distribution piping.

Henry, Christopher G.↗

Water Microgrids: A Primer for Facility Managers

A water microgrid is similar in concept to an energy microgrid, which the U.S. Department of Energy defines as “a local energy grid with control capability, which means it can disconnect from the traditional grid and operate autonomously.” Similarly, a water microgrid is a local water system that supplies, treats, and distributes water, with the primary objective to meet mission critical water demands during a disruption of the primary supply. A water microgrid has the capability to operate independently of an existing primary water system and includes a layer of sensing capability that provides the necessary monitoring and controls to operate the water microgrid. A water microgrid may offer a viable solution for a site to address resilience gaps identified through the resilience planning process. For example, a site may not have adequate and redundant water supply to meet mission critical demands with vulnerabilities in the operating systems. A water microgrid provides the ability to island the water system from the primary water supply to satisfy water demand requirements throughout an outage or disruption.

42 ENGINEERING↗

Development and Evaluation of Distributed Energy Resource Device Models: Electric Vehicles, Electric Water Heaters, and Commercial Refrigeration Systems

In order to validate distributed energy resource (DER) models operated with grid services in the GMLC 1.4.2 team’s February (GMLC 2019a) and July (GMLC 2019b) reports, a test and measurement program using actual DER devices was conducted by national laboratories for three devices: (1) electric vehicles (EVs), (2) water heaters, and (3) commercial refrigeration. Test procedures were developed and carried out to identify the mathematical models and their parameters that describe the operational function, characterize the physics, and obey transient response of the devices. This report focuses on the experimental results obtained to develop and verify simulations of three specific EV models. This section summarizes elements of the mathematical model and shows the necessity data collected from the EVs while charging and discharging (driving). In the course of the study, we found it necessary to make some modifications to the model to deal with observed transient behavior. Section 1.2 details the model assumptions and equations, Section 1.3 provides details of the EVs tested, Section 1.4 outlines the test procedures developed for the projects, and Section 1.5 presents the experimental results obtained for the three different EVs tested and how these results compare to the models running the same test profiles.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Emerging Technologies Review: Water Microgrid

Project 69643 Task 10 - The Air Force Civil Engineer Center has tasked Pacific Northwest National Laboratory with investigating emerging technologies to inform the Air Force’s understanding of the technology and to guide key considerations for implementing technologies that are resilient and alternative sources to the traditional methods used in the Air Force today. This report explores the concept of a water microgrid for deployment at Air Force installations. A water microgrid is a local water system that supplies, treats, and distributes water, with the primary objective to meet mission critical water demand during a disruption of the primary supply. A water microgrid can advance an Air Force installation’s water infrastructure and water resilience by being at the ready for meeting critical missions during a utility outage.

42 ENGINEERING↗

U.S. Industrial and Commercial Motor System Market Assessment Report. Volume 3: Energy Saving Opportunity

This report seeks to inform the potential for motor systems to support decarbonization by estimating their potential energy, electricity cost, and CO 2 emissions reduction potential from adoption of proven energy efficiency actions and advanced technologies. This is the third and final report in a series of reports disseminating the findings of the U.S. Department of Energy’s (DOE’s) Motor System Market Assessment (MSMA). The MSMA and this report focus on polyphase motor systems greater than or equal to 1 horsepower (hp) in the industrial and commercial sectors. In the U.S. Industrial and Commercial Motor System Market Assessment Report Volume 1: Characteristics of the Installed Base (Volume 1 report), it was determined that these motor systems consume more than 1,000 terawatt-hours (TWh) annually. This equates to 29% of the U.S. electric grid load and results in 765 million metric tons (MMT) of CO 2 emissions and $166 billion in electricity costs. This report finds that substantial reductions to these energy, cost, and emissions impacts are possible, with three areas of significant opportunity being (1) improved load matching, (2) replacing older inefficient motors with more efficient motors, and (3) improving the condition of fluid (e.g., air, water, compressed air) distribution systems. A summary of the savings potential from these three opportunities placed within the context of the overall consumption for motor systems is illustrated in Figure ES 1 (industrial) and Figure ES 2 (commercial).

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Energy Master Planning: Identifying Framing Constraints that Scope Your Technology Options

This paper addresses the framing constraints for building and community energy projects that must be considered when energy master planning (EMP) is conducted. The constraints cover emissions, sustainability, resilience, regulations and directives, and regional and local limitations such as available energy types, local conditions, and project requirements. The paper reflects development results from participants in an International Energy Agency project on energy master planning and in a U.S. Department of Defense project on technology integration to achieve resilient, low-energy use military installations. It identifies a comprehensive list of framing constraints categorized into locational threats, locational resources, energy and water distribution and storage systems, building and facility, indoor environmental, and equipment in buildings and district systems constraints. In addition, it identifies limits for these constraints that exist in seven participating countries. Some framing constraints can profoundly impact technology selection while others impact the installation of technologies (as in hardening) and have little to no impact on technology selection. Furthermore, framing constraints can be assessed in different ways and there are resources available to help EMP stakeholders evaluate them. Finally, a case is made that identifying and applying framing constraints early in EMP can bring efficiencies and better focus to the EMP process. We come to the conclusion that (1) for holistic energy planning, it is essential to identify and assess the framing constraints that bound an optimized EMP solution, (2) framing constraints limits should be evaluated as either hard or soft or promising technologies may fall out of an EMP analysis, (3) to maintain consistent quality in the EMP process, the identification of framing constraints and their limits, and perhaps their evaluation, should be standardized, (4) a standardized approach could establish a baseline that can be used, built upon, and improved, (5) as automated EMP tools are improved or developed, the resources in this paper could possibly contribute to their interworkings relative to technology screening, and (6) continued climate change and resulting aggressive goal setting will likely drive a continued and strong emphasis on EMP.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

ReaxFF molecular dynamics simulations of electrolyte–water systems at supercritical temperature

We have performed ReaxFF molecular dynamics simulations of alkali metal–chlorine pairs in different water densities at supercritical temperature (700 K) to elucidate the structural and dynamical properties of the system. The radial distribution function and the angular distribution function explain the inter-ionic structural and orientational arrangements of atoms during the simulation. The coordination number of water molecules in the solvation shell of ions increases with an increase in the radius of ions. We find that the self-diffusion coefficient of metal ions increases with a decrease in density under supercritical conditions due to the formation of voids within the system. The hydrogen bond dynamics has been interpreted by the residence time distribution of various ions, which shows Li+ having the highest water retaining capability. The void distribution within the system has been analyzed by using the Voronoi polyhedra algorithm providing an estimation of void formation within the system at high temperatures. We observe the formation of salt clusters of Na+ and K+ at low densities due to the loss of dielectric constants of ions. The diffusion of ions gets altered dramatically due to the formation of voids and nucleation of ions in the system.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Computationally efficient subglacial drainage modelling using Gaussian process emulators: GlaDS-GP v1.0

Subglacial drainage models represent water flow at the ice–bed interface through coupled distributed and channelized systems to determine water pressure, discharge, and drainage system geometry. While they are used to understand processes such as the relationship between surface melt and ice flow, the number of uncertain model parameters and the computational cost of running models makes it difficult to adequately explore the high-dimensional parameter space and evaluate uncertainty in model predictions. Here, we develop Gaussian process (GP) emulators that make fast predictions with associated uncertainty of subglacial drainage model outputs. Using a truncated principal component (PC) basis representation, we construct a GP emulator for diurnally averaged subglacial water pressure. We also explore emulation of scalar variables describing drainage efficiency and configuration. We train the emulators using ensembles of up to 512 simulations varying eight parameters of the Glacier Drainage System (GlaDS) model on a synthetic domain intended to represent an ice-sheet margin. The emulators make predictions ∼ 1000 times faster than GlaDS simulations, with errors <3 % for the water pressure field and ∼ 5 %–9 % for drainage efficiency and configuration. We apply the emulators to explore the eight-dimensional parameter space by computing variance-based parameter sensitivity indices, finding that three parameters (ice flow coefficient, bed bump aspect ratio, and the subglacial cavity system conductivity) explain 90 % of the variance in modelled water pressure in response to parameter changes. The GP emulator approach described here is well suited to integrating observational data with models to make calibrated, credible predictions of subglacial drainage.

58 GEOSCIENCES↗

Interdependent Water And Power Infrastructure Model

The approach used is the Multi-Agent System (MAS) paradigms, where systems components are represented as agents, interacting both with each other, and with the environment in which they evolved. Agents behaviors correspond to components in the real Integrated Water-Power System. The model simulate actions and interactions of these (autonomous) agents to analyze their effects on the overall system. Agents in the water system capture components of water collection, treatment, transportation, distribution and use (e.g. pipe, canal, pump, water demands for agriculture, etc.). Agents in the power system capture components of power generation, transportation, distribution and use (electricity demands, sources, etc.).

Toba, Danho Ange Lionel [Idaho National Laboratory↗

Resilience assessment and planning in power distribution systems: Past and future considerations

High impact low probability (HILP) events such as hurricanes, heat waves, and floods have instigated widespread power outages and blackouts around the globe in the past decade. With the increasing challenges concerning the threats to the power distribution systems and the growing need to mitigate the impacts of the HILP events, resilience has become a crucial requirement for the power grid infrastructures. Numerous efforts have been made to define, measure, and characterize the resilience of power distribution systems. This study thoroughly reviews the state-of-the-art methods on the existing resilience evaluation framework and metrics. Here, the desirable characteristics of resilience metrics are highlighted, and the challenges associated with formulating, developing, and calculating such metrics are discussed. Next, we detail the state-of-the-art literature on planning solutions to ensure distribution system resilience. This paper aims to extract a deep insight into this challenging and critical research area and envision future opportunities that can guide the power distribution system operators/planners to formulate more effective mitigation strategies to enhance the resilience of power distribution systems.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Transactive Electric Water Heater Agent: Design and Performance Evaluation

Electric water heaters (EWHs) are usually equipped with inbuilt thermostats to measure water temperature near the installed positions. Most of the existing EWHs have only two thermostats and often do not have water flow sensor installed. Estimation of state of heat energy (SOHE) inside the hot water tank, which is crucial for efficient control and operation of the EWH, under such imperfect system conditions is very challenging. This paper, therefore, designs a transactive EWH agent (TEWHA) to better estimate SOHE in presence of measurement errors and imperfect system knowledge. The TEWHA, built-in Python, approximates the EWH physics using limited measurements obtained from the ground truth GridLABD model. The performance of the TEWHA is validated against ground truth system for three scenarios: a) ideal condition where TEWHA has complete knowledge of the system, b) imperfect condition where TEWHA has incomplete system information, and c) noised condition where TEWHA measurements contain random errors. Finally, an optimization problem is formulated and solved to demonstrate how TEWHA could use the estimated and measured parameters for a transactive control of EWH. Index Terms—Demand flexibility

demand flexibility, distribution system, electric ↗

Evaluating Resilience of Water Distribution Networks to Operational Failures from Cyber-Physical Attacks

Water cyber-physical systems (CPSs) have gained increasing interest to improve operational efficiency and reliability. However, due to growing exposure to cyber-physical attacks, cybersecurity and resilience against the attacks have become significant concerns. There have been efforts to improve cybersecurity in water CPSs, yet few attempts to investigate resilience against cyber-physical attacks. This study contributes to characterizing resilience of a water CPS and investigating potential resilience strategies. An advanced resilience measure integrating withstanding, absorptive, adaptive, and restorative capability of a system is proposed and applied to the C-town water distribution network (WDN) for 15 failure set scenarios with a pressure-driven hydraulic simulation. The results provide identification of failure sets and unfavorable operational conditions that make the system more vulnerable to the cyber-physical attacks and in turn produce low resilience and capabilities. It is also found that, after recovery of a disrupted component, adjustment of overall operational interactions across system components is needed for complete restoration of disrupted functionality. The findings provide insights on infrastructure investment with resilience strategies in cyber and physical water system domains.

Shin, Sangmin↗

Leveraging Existing Assets for Long Duration Energy Storage

Increased renewables penetration to electrical grid is necessary to reduce overall emissions from the electrical power generation sector. Nonetheless, its integration creates challenges to grid operators who must match the power being generated by intermittent renewables and other traditional energy sources with the demand from consumers, while ensuring the reliability and power quality for the entire system. Energy storage has been proposed as an alternative to natural gas peaking plants and a form to deliver excess renewable energy generation at times of peak demand. For energy storage to provide benefits to end customers (energy consumers), it must be reliable, efficient, and cost effective. The Illinois Sustainable Technology Center (ISTC), one of the surveys that integrate the Prairie Research Institute (PRI), aims to develop a Center for Energy Storage at Existing Assets (CESEA) at UIUC with the participation of Waste Pressure Corp and Ecotek Engineering USA LLC. CESEA will focus on LDES systems that can integrate to existing infrastructure in a manner that reduces the initial capital expenditure and demonstrates the ability to repurpose fossil assets that would otherwise become stranded, to serve the energy transition. CESEA aims to leverage UIUC’s unique facilities to validate LDES systems performance at a relevant operating environment. UIUC’s facilities include a 85-MW combined heat and power (CHP) power plant, two (2) solar PV plants totaling over 18 MWdc of installed capacity, an electrical grid along with a substation at transmission and distribution voltages, a 22-mile gas pipeline network operating at two pressure levels, along with steam and chilled water distribution networks. The new LDES systems will connect to the existing UIUC grid through a new test electrical station, which will have the capacity to accommodate additional connections to test new devices and technologies as part of future CESEA R&D activities. The test electrical station will contain meters, instrumentation, and controls to accurately capture data and allow optimization of control algorithms. CESEA will initially focus on technologies that: i) utilize existing equipment or facilities to perform at least one of the process steps in LDES (charging, storage, or discharging), ii) leverage mature or commercially available components or controls, iii) show potential for cost-leadership in 10+ hour storage at a commercial scale. Initial technologies that were identified to meet these criteria include Compressed Gas Energy Storage (CGES), and TES. CGES stores electricity by raising the pressure of a compressible gas inside a control volume and converting the stored energy to electricity via expansion-generation. CGES is a generalization of CAES that covers any working gas (not just air). A successful CGES demo will help to circumvent many challenges faced by CAES (long development times due to site prospecting, high cost of compression and storage, heat recovery management, etc.) by: 1) utilizing existing infrastructure (compressors, pipelines, underground storage or pressure vessels) used in the transportation and storage of industrial gases for LDES charging and storage; 2) deploying over sites already-developed for industrial applications with minor additional work; 3) leveraging the price structure of commercial industrial gas to cover the costs of electricity used during charging. A previous DOE-sponsored conceptual study (DE-FE-0032018) estimated the levelized cost of energy of a 1.1 MW / 17 MWh CGES system at $0.08/kWh, with a commercial 10x scale system cost estimated at <$0.04/kWh (Giardinella, 2022). The pilot-sized system was estimated to avoid up to 2693 tons of CO2/year.

25 ENERGY STORAGE↗