Engineering PapersSearch

SEARCH · Engineering Papers

Results for “voltammetry”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

The Nickel(111)/Alkaline Electrolyte Interface

The electrochemical properties of Ni (111) prepared and characterized in ultra high vacuum, UHV, by surface analytical techniques have been examined in alkaline media by cyclic voltammetry using an UHV-electrochemical cell transfer system designed and built in this laboratory. Prior to the transfer, the Ni(111) surfaces were exposed to saturation coverages of CO in UHV in an attempt to protect the surface from possible contamination with other gases during the transfer. Temperature Programmed Desorption, TPD, of CO-dosed Ni (111) surfaces displaying sharp c(4x2), LEED patterns, subsequently exposed to water-saturated Ar at atmospheric pressure in an auxiliary UHV compatible chamber and finally transferred back to the main UHV chamber, yielded CO2 and water as the only detectable products. This indicates that the CO-dosed surfaces react with water and/or bicarbonate and hydroxide as the most likely products. Based on the integration of the TPD peaks, the combined amounts of H2O and CO2 were found to be on the order of a single monolayer. The reacted c(4x2)CO/Ni(111) layer seems to protect the surface from undergoing spontaneous oxidation in strongly alkaline solutions. This was evidenced by the fact that the open circuit potential observed immediately after contact with deaerated 0.1 M KOH was about 0.38 V vs. DHE, drifting slightly towards more negative values prior to initiating the voltametric scans. The average ratio of the integrated charge obtained in the first positive linear scan in the range of 0.35 to 1.5 V vs. DHE (initiated at the open circuit potential) and the first (and subsequent) linear negative scans in the same solution yielded for various independent runs a value of 3.5 +/- 0.3. Coulometric analysis of the cyclic voltammetry curves indicate that the electrochemically formed oxyhydroxide layer involves a charge equivalent to 3.2 +/- 0.4 layers of Ni metal.

Wang, Kuilong

Redox-Active Star Molecules Incorporating the 4-Benzolypyridinium Cation: Implications for the Charge Transfer Efficiency Along Branches versus Across the Perimeter in Dendrimers

We report the redox properties of four star systems incorporating the 4-benzoyl-N-alkylpyridinium cation; the redox potential varies along the branches, but remains constant at fixed radii. Voltammetric analysis (cyclic voltammetry and differential pulse voltammetry) shows that only two of the three redox-active centers in the perimeter are electrochemically accessible during potential sweeps as slow as 20 mV/s and as fast as 10 V/s. On the contrary, both redox centers of a branch are accessible electrochemically within the same time frame. These results are discussed in terms of slow through-space charge transfer and the globular 3-D folding of the molecules.

Yang, Jin-Hua

E-tongue 2 REDOX response to heavy metals

E-Tongue 2 an array of electrochemical sensors including REDOX electrodes for Cylic Voltammetry and Anodic Stripping Voltammetry measurements, Galvanic cells for corrosion measurements, and Ion Selective Electrodes.

electromechanical sensors

Redox-Active Star Molecules Incorporating the 4-Benzoylpyridinium Cation - Implications for the Charge Transfer Along Branches vs. Across the Perimeter in Dendrimer

Dendrimers are self-repeating globular branched star molecules, whose fractal structure continues to fascinate, challenge, and inspire. Functional dendrimers may incorporate redox centers, and potential applications include antennae molecules for light harvesting, sensors, mediators, and artificial biomolecules. We report the synthesis and redox properties of four star systems incorporating the 4-benzoyl-N-alkylpyridinium cation; the redox potential varies along the branches but remains constant at fixed radii. Bulk electrolysis shows that at a semi-infinite time scale all redox centers are electrochemically accessible. However, voltammetric analysis (cyclic voltammetry and differential pulse voltammetry) shows that on1y two of the three redox-active centers in the perimeter are electrochemically accessible during potential sweeps as slow as 20 mV/s and as fast as 10 V/s. On the contrary, both redox centers along branches are accessible electrochemically within the same time frame. These results are explained in terms of slow through-space charge transfer and the globular 3-D folding of the molecules and are discussed in terms of their implications on the design of efficient redox functional dendrimers.

Leventis, Nicholas

Surface Analysis of 4-Aminothiophenol Adsorption at Polycrystalline Platinum Electrodes

Formation of self-assembled monolayer (SAM) of 4-aminothiophenol (4-ATP) on polycrystalline platinum electrodes has been studied by surface analysis and electrochemistry techniques. The 4-ATP monolayer was characterized by cyclic voltammetry (CV), Raman spectroscopy, reflection absorption infrared (RAIR) spectroscopy, and X-ray photoelectron spectroscopy (XPS). Cyclic voltammetry (CV) experiments give an idea about the packing quality of the monolayer. RAIR and Raman spectra for 4-ATP modified platinum electrodes showed the characteristic adsorption bands for neat 4-ATP indicating the adsorption of 4-ATP molecules on platinum surface. The adsorption on platinum was also evidenced by the presence of sulfur and nitrogen peaks by XPS survey spectra of the modified platinum electrodes. High resolution XPS studies and RAIR spectrum for platinum electrodes modified with 4-ATP indicate that molecules are sulfur-bonded to the platinum surface. The formation of S-Pt bond suggests that ATP adsorption gives up an amino terminated SAM. Thickness of the monolayer was evaluated via angle-resolved XPS (AR-XPS) analyses. Derivatization of 4-ATP SAM was performed using 16-Br hexadecanoic acid.

Rosario-Castro, Belinda I.

Fundamental Investigation of Silicon Anode in Lithium-Ion Cells

Silicon is a promising and attractive anode material to replace graphite for high capacity lithium ion cells since its theoretical capacity is ~10 times of graphite and it is an abundant element on Earth. However, there are challenges associated with using silicon as Li-ion anode due to the significant first cycle irreversible capacity loss and subsequent rapid capacity fade during cycling. Understanding solid electrolyte interphase (SEI) formation along with the lithium ion insertion/de-insertion kinetics in silicon anodes will provide greater insight into overcoming these issues, thereby lead to better cycle performance. In this paper, cyclic voltammetry and electrochemical impedance spectroscopy are used to build a fundamental understanding of silicon anodes. The results show that it is difficult to form the SEI film on the surface of a Si anode during the first cycle; the lithium ion insertion and de-insertion kinetics for Si are sluggish, and the cell internal resistance changes with the state of lithiation after electrochemical cycling. These results are compared with those for extensively studied graphite anodes. The understanding gained from this study will help to design better Si anodes, and the combination of cyclic voltammetry with impedance spectroscopy provides a useful tool to evaluate the effectiveness of the design modifications on the Si anode performance.

Wu, James J.

Autonomous Measurement of Electrochemical Redox Couples for In-Situ Characterization of Enceladus Plume Samples

A 3D-printed microfluidic electrochemical cell with integrated electrodes was developed to demonstrate autonomous in-situ electrochemical characterization of terrestrial seawater samples. The system is designed to extend the capabilities of the 2008 Phoenix Lander’s Wet Chemistry Laboratory (WCL) that analyzed the soluble chemistry of the Martian soil, by miniaturizing its fluidic architecture for analysis of µL-volume samples as expected from an Enceladus fly-by mission. The microfluidic device has a total fluid volume of 48 µL and includes dual channels each populated with 7 electrodes. Measurement of pH was measured using an iridium oxide electrode. Cyclic voltammetry with Au, Pt, and glassy carbon working electrodes was used to measure redox couples in synthetic seawater that contained inorganic and bio-organic molecules. Glassy carbon was found to have minimal risk of interference from constituents of synthetic seawater when measuring molecular organic redox species; however, care must be used to prevent interference due to potential oxidation or dissolution in the case of Au working electrodes. A completely autonomous end-to-end run including sample delivery was performed, to demonstrate the feasibility of microfluidic-based cyclic voltammetry measurements for in-situ characterization of redox couples in Ocean World samples.

Planetary Instruments

Challenges in selecting appropriate electrodes for high-temperature molten salt systems

Based on a specific molten salt (e.g., chloride, fluoride, iodide) investigated, different working and reference electrode materials can be selected considering the chemical and thermal stability of the electrochemical cell components. In this talk, the electrode materials and challenges encountered with a spectro-electrochemical setup installed inside a glovebox, and the solutions implemented to address these challenges, specifically for the chloride and iodide molten salts will be presented. For molten chlorides, the fundamental interactions between neodymium chloride (NdCl3) and Nd metal in lithium chloride-potassium chloride eutectic salt were investigated at 773 K. The electrochemical transitions Nd2+,3+/Nd(s) were analyzed using an inert W electrode with cyclic voltammetry and chronoamperometry techniques, coupled with in-situ UV-Vis spectroscopy to elucidate the kinetic pathways of this disproportionation reaction (eq. 1). Nd(s) + NdCl3 = NdCl2 (1) For molten iodides, the challenges related to working electrode selectivity and present spectro-electrochemical results obtained from cyclic voltammetry measurements conducted at 673 K will be discussed.

36 - MATERIALS SCIENCE

Understanding the speciation of molten iodide salts via spectro-electrochemistry

Iodine is a high yield fission product of concern for the environmental effects due to its high volatility and biological impacts to the human body. Iodine speciation in molten salts, specifically iodide salts, is not well understood due to its reactivity at higher temperature domains. UV-Vis spectroscopy indicates a change in the speciation of the molten iodide salts starting at 500oC based on the decomposition of the salt itself, forming I3- ions. This work investigated the spectral changes of I- ions in molten LiI-KI and LiI-KI-NiI2 while manipulating the salts electrochemically using an inert graphite electrode at 400oC.The Li+/Li(s) and the Ni2+/Ni(s) transitions were studied using cyclic voltammetry, chronoamperometry/chronopotentiometry to characterize the respective reduction-oxidation waves. As cyclic voltammetry was applied, the UV-Vis spectroscopy showed a change in the characteristic signal of molten LiI-KI, indicating a disproportionation reaction in the molten salt, leading to formation of I3- ions and I2 gas.

36 - MATERIALS SCIENCE

Functional roles of the [2Fe-2S] clusters in Synechocystis PCC 6803 Hox [NiFe]-hydrogenase reactivity with ferredoxins

The HoxEFUYH complex of Synechocystis PCC 6803 (S. 6803) consists of a HoxEFU ferredoxin:NAD(P)H oxidoreductase subcomplex and a HoxYH [NiFe]-hydrogenase subcomplex that catalyzes reversible H2 oxidation. Prior studies have suggested that the presence of HoxE is required for reactivity with ferredoxin; however, it is unknown how HoxE is functionally integrated into the electron transfer network of the HoxEFU:ferredoxin complex. Deciphering electron transfer pathways is challenged by the rich iron-sulfur cluster content of HoxEFU, which includes a [2Fe-2S] cluster in each subunit, along with multiple [4Fe-4S] clusters and a flavin cofactor. To resolve the role of HoxE, we determined the biophysical and thermodynamic properties of each [2Fe-2S] cluster in HoxEFU using steady-state and potentiometric EPR analysis in combination with square wave voltammetry (SWV). The temperature-dependence of the EPR signal for HoxE confirmed the coordination of a single [2Fe-2S] cluster that was shown by SWV to have an E m = -424 mV (versus SHE). Strikingly, when the E m of the HoxE [2Fe-2S] cluster was analyzed in HoxEFU titrations, it was shifted by >100 mV to an E m < -525 mV (versus SHE). EPR titrations of HoxEFU gave an E m value for the [2Fe-2S] cluster of HoxF, E m = -419 mV and HoxU, E m = -349 mV. These values were used to re-analyze the diaphorase kinetics in reactions performed with ferredoxins with varying E m 's. The results are formulated into a model of HoxEFU:ferredoxin reactivity and the role of HoxE in mediating electron transfer within the HoxEFU:ferredoxin complex.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH

Electrochemical behavior of SnCl 2 and influence of Cu and Ni ions in molten LiCl−KCl−CaCl 2 eutectic

Reliable transport and thermodynamic data for multivalent ions in complex molten salts are scarce, limiting model fidelity for electrorefining and impurity control. Here, we report a comprehensive electrochemical characterization of SnCl₂ in LiCl–KCl–CaCl₂ (50.5–44.2–5.3 mol%) at 685 K, including the effects of Ni 2+ and Cu + impurities. Using cyclic voltammetry (CV), chronoamperometry (CA), and chronopotentiometry (CP), we quantified Sn 2+ and Ni 2+ diffusion with exceptional agreement across methods: Sn 2+ averaged (1.03 ± 0.10) × 10 −5 cm 2 s −1 , and Ni 2+ averaged (0.75 ± 0.19) × 10 −5 cm 2 s −1 . The tight confidence-interval overlap across CV, CA, and CP strengthens confidence in these values and is uncommon in molten chloride studies. Open-circuit-potential measurements provided standard apparent reduction potentials that closely match LiCl–KCl literature, indicating minimal shift with CaCl₂ present. The Sn 2+ /Sn couple behaves as a reversible two-electron soluble–insoluble process at 685 K; the Sn 4+ /Sn 2+ couple transitions to soluble–soluble behavior near 788 K, which may correlate with the decomposition of surface bound chlorostannates, though direct characterization remains to be established. In mixed systems, Cu+/Cu overlaps Sn 2+ /Sn, limiting Cusingle bondSn electroseparation, whereas the larger potential gap between Ni 2+ /Ni and Sn 2+ /Sn supports selective Ni removal. These internally consistent transport and thermodynamic data establish a validated basis for process modeling and optimization of Sn electrorefining and impurity management in LiCl–KCl–CaCl₂.

Berzins-Delahay

Influence of solvents on electrochemical stability window of ionic liquid solutions

The electrochemical stability window (ESW) defines the voltage range within which an electrolyte remains stable against oxidation and reduction, serving as a key descriptor for ionic liquid (IL)-based systems. The ESWs of 15 ILs with diverse cation-anion combinations were systematically investigated, both in their neat forms and as binary mixtures with three representative solvents, i.e., propylene carbonate (PC), ethylene glycol (EG), and tetrahydrofuran (THF). Cyclic voltammetry on a glassy carbon electrode determined anodic and cathodic stability limits, revealing that ESW protection in IL-solvent mixtures strongly depends on solvent polarity, proticity, and IL compatibility. PC, with a high dielectric constant and aprotic character, broadened anodic limits and moderately stabilized cathodic limits. THF maintained compact interfacial structure, offering additional cathodic protection, whereas EG, being protic, reduced ESWs via proton-coupled electron transfer and hydrogen evolution. The solvent protection trend followed by PC > THF > EG, with bulky, hydrophobic cations ([HMIM] + , [BMPYRR] + ) and weakly coordinating anions ([NTF 2 ] - , [DCA] - , [DEP] - ) showing the highest ESW protection for 50 mol% IL in these solvents. Among the neat ILs, [EMIM][DEP], [HMIM][PF 6 ], and [BMPYRR][DCA] showed wide ESWs of ∼5.5 V. These results provide valuable insight into solvent-modulated electrochemical stability, enabling rational design of IL-based electrolytes for energy storage and electrosynthesis.

25 ENERGY STORAGE

Self-Assembled Bolaamphiphile-Based Organic Nanotubes as Efficient Cu(II) Ion Adsorbents

Self-assembled organic nanotubes (ONTs) have been actively examined for various applications such as chemical separations and catalysis owing to their well-defined tubular nanostructures with distinct chemical environments at the wall and internal/external surfaces. Adsorption of heavy metal ions onto ONTs plays an essential role in many of these applications, but it has rarely been assessed quantitatively. Herein, we investigated interactions between Cu 2+ and single-/quadruple-wall bolaamphiphile-based ONTs having inner carboxyl groups with different inner diameters, COOH-ONT 10nm and COOH-ONT 20nm . We first examined the effects of Cu 2+ on their nanotubular structures using SAXS, STEM, and AFM. COOH-ONT 10nm was stable in aqueous Cu 2+ solution in contrast to COOH-ONT 20nm owing to the presence of polyglycine-II-type hydrogen bonding networks within its wall. Subsequently, we studied the Cu 2+ adsorption behavior of COOH-ONT 10nm by monitoring the concentration of unbound Cu 2+ using linear sweep anodic stripping voltammetry. The Cu 2+ adsorption was quick, attributable to efficient Cu 2+ partitioning through the open ends of the ONT, followed by fast Cu 2+ diffusion in the uniform, relatively large nanochannel. More importantly, the Cu 2+ adsorption capacity and affinity of COOH-ONT 10nm were measured at different pH using the Langmuir adsorption model. The adsorption capacity was similar at the pH range examined, showing the participation of approximately 25% of the inner carboxyl groups in the adsorption. The adsorption affinity increased with pH, indicating the essential role of the deprotonated carboxyl groups in the Cu 2+ adsorption. Most interestingly, the Langmuir adsorption constant was significantly higher than those of previously reported synthetic adsorbents and planar monolayer based on carboxyl binding sites. The high Cu 2+ affinity of the ONT was attributable to the highly dense binding sites on the well-defined nanoscale concave structure of the inner channel. Furthermore, these results provide a valuable guideline to designing self-assembled nanomaterials for efficient chemical separations, detection, and catalysis.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH

Flow Enhanced Electrochemical Sensor Performance in Complex Salt Systems

To advance MSR MC&A practices, Argonne National Laboratory developed and optimized robust flow enhanced electrochemical sensors (FEES) and multielectrode array voltammetry sensors (MAVS) which provide accurate near-real time measurements of actinides in molten salts. Flow-enhanced electrochemical sensors are installed directly into MSR flow conduits for inline salt chemistry measurement, while MAVS are deployed in quiescent salt conditions enabling online species concentration determination in stationary salt vessels. This report summarizes efforts to improve electrochemical sensor technological readiness through (1) sensor testing in complex, high concentration molten salt systems to demonstrate low uncertainty actinide measurements in MSR-representative solutions and (2) demonstrations of sensor performance in challenging real-world conditions in collaboration with partner MSR institutions.

22 GENERAL STUDIES OF NUCLEAR REACTORS

Initial Trade Study for In-line Silver Sensor for Spacecraft Potable Water Systems

Ionic silver is currently baselined as the biocide for microbial control in potable water systems for future space exploration missions. In-line monitoring of silver ion concentration is desired for system feedback control to introduce and maintain sufficient and safe levels of biocide in the water. To date, NASA testing of silver biocide system prototypes has made use of an Ion-Selective Electrode (ISE) for in-line silver concentration measurements. However, known issues with ISE technology have continued to motivate a search for alternate sensor systems. Although devices capable of detecting silver are available for terrestrial applications, these systems are generally not well-suited for the unique demands of spaceflight. Desired attributes include: low weight, volume, and power consumption; stable, autonomous, and in-line measurement capability; long calibration lifetime; and limited maintenance requirements. This paper provides the results from a preliminary trade study conducted on three candidate silver sensor technologies: ISEs, Anodic Stripping Voltammetry (ASV), and Fiber Optic Chemical Sensors (FOCS). The review of these technologies includes the rationale for their selection, an overview of the principles of their operation, and a detailed assessment of their strengths and weaknesses relative to the anticipated requirements of future spacecraft applications. The study concluded that none of the currently-available versions of these technologies is suitable for immediate application to spacecraft systems; further technology development should be considered. To that end, recommendations for forward development work have been proposed and provided herein.

Potable Water

In situ monitoring of lanthanide reactions with oxide species via combined absorption spectroscopy and electrochemical methods

Molten salts for engineering scale applications of spent nuclear fuel pyrochemical processing will inevitably have some level of oxygen impurities which can form various insoluble oxide and oxychloride species with uranium and fission products. This work demonstrates real-time concentration monitoring of two trivalent lanthanide (Ln3+) fission products, Nd3+ and Pr3+, and their reactions with oxygen (O2-) impurities to form insoluble products in LiCl-NaCl-KCl eutectic salt. A combination of high-temperature absorption spectroscopy and electrochemical testing were used to track lanthanide concentrations. O2- impurity levels were controlled in the range of 0.001 M to 0.5 M by adding Li2O to lanthanide-salt solutions. After the introduction of O2- impurities, Ln3+ concentrations were monitored via time-resolved absorption spectroscopy. Concentrations of both Ln3+ species in solution decreased with time as insoluble products formed. The initial impurity concentration controlled whether insoluble products were predominantly oxychlorides (LnOCl) or mixtures of oxychlorides and oxides (Ln2O3). However, absorption spectroscopy is limited for weakly absorbing species, such as Pr3+, and under conditions of high impurity concentrations where solutions can be turbid. To circumvent this limitation, the concentrations of Pr3+ were monitored with square wave voltammetry (SWV). Estimated reaction rates and extent of Pr3+ removal from solution as monitored by SWV agreed to within ~10% of the results found from absorption spectroscopy monitoring. This demonstrates that simultaneous electrochemical testing complements and expands the capabilities of absorption spectroscopy to monitor reactions of fission products in molten salts.

11 - NUCLEAR FUEL CYCLE AND FUEL MATERIALS

Powder‐to‐Film Conversion of Nickel Single‐Atom Catalysts into Binder‐Free and Resistant Electrodes

Although a few binder-free and self-supported single-atom electrodes have been reported, achieving mechanically robust, defect-engineered, and reproducible films that preserve atomic dispersion under electrochemical operation remains challenging. This work addresses this limitation by presenting a versatile and generalizable strategy to transform powders into standalone, defect-engineered thin films hosting atomically dispersed Ni centers within conductive 2D frameworks. The physicochemical and electronic properties of these materials are thoroughly characterized using a comprehensive set of spectroscopic and microscopic techniques and confirmed the homogeneous dispersion and monoatomic nature of the Ni centers (0.94 wt.%) on the electrode films. Electrochemical testing via cyclic voltammetry and electrochemical impedance spectroscopy under a range of experimental conditions revealed that integration of Ni single atoms markedly enhanced performance and stability compared to carbon nanotube-only electrodes, maintaining integrity after 15 h of continuous operation. This improvement is accompanied by a notable reduction in charge transfer resistance (30.50 Ω) and an increase in double-layer capacitance (295.45 µF). Post-electrochemical analyses corroborated the structural integrity and robustness of the electrodes. Overall, this work bridges atomically precise catalysis and device-level electrochemistry, opening a route toward reproducible and scalable single-atom electrodes for sensing and energy conversion.

36 MATERIALS SCIENCE

Emulation of Synaptic Plasticity in WO 3 ‐Based Ion‐Gated Transistors

Neuromorphic systems, inspired by the human brain, promise significant advancements in computational efficiency and power consumption by integrating processing and memory functions, thereby addressing the von Neumann bottleneck. This paper explores the synaptic plasticity of a WO3-based ion-gated transistor (IGT) in [EMIM][TFSI] and a 0.1 mol L −1 LiTFSI in [EMIM][TFSI] for neuromorphic computing applications. Cyclic voltammetry (CV), transistor characteristics, and atomic force microscopy (AFM) force–distance (FD) profiling analyses reveal that Li + brings about ion intercalation, together with higher mobility and conductance, and slower response time (τ). WO 3 IGTs exhibit spike amplitude-dependent plasticity (SADP), spike number-dependent plasticity (SNDP), spike duration-dependent plasticity (SDDP), frequency-dependent plasticity (FDP), and paired-pulse facilitation (PPF), which are all crucial for mimicking biological synaptic functions and understanding how to achieve different types of plasticity in the same IGT. The findings underscore the importance of selecting the appropriate ionic medium to optimize the performance of synaptic transistors, enabling the development of neuromorphic systems capable of adaptive learning and real-time processing, which are essential for applications in artificial intelligence (AI).

36 MATERIALS SCIENCE