SiC Based Modular Transformer-less MW-Scale Power Conditioning System and Control for Flexible CHP System

This project aims at developing a SiC-based, modular, transformer-less (60-Hz-transformers-free), MW-scale, four-wire DC/AC power conditioning system (PCS) converter, and a corresponding control system for flexible-CHP (F-CHP) systems. With the help of an F-CHP controller and power electronics converters, different CHP sources, renewable sources, and batteries can be assembled to the DC grid, which is then connected to the medium voltage (MV) AC grid through the PCS converter. To meet grid support and performance requirements, the F-CHP controller design and PCS converter design follow IEEE 1547 and IEEE 2030.7 standards. Five main tasks, including PCS converter design, F-CHP controller development, PCS converter prototype building and testing, F-CHP controller testing, and PCS paralleling, have been carried out. In this project, the F-CHP controller testing has been completed in simulation, HIL and HTB, and the PCS converter prototypes have been successfully built and tested.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A Novel Decentralized PWM Interleaving Technique for Ripple Minimization in Series-Stacked DC-DC Converters

Cascaded dc-dc converters are commonly used in applications where distributed energy sources or loads are connected to elevated voltage levels for power transfer. In such systems, it is advantageous to minimize the ripple on the bus current and voltage by proper phase shifting of the pulse-width modulation (PWM) pulses among the converters via a method known as interleaving. Existing approaches use either a centralized controller or separate communication lines among the stacked converters to control their relative PWM switch transitions. The key drawbacks are that these methods entail significant wiring, the central controller acts as a single point of failure, and implementation on very large numbers of units is impractical. In this paper, we introduce a decentralized interleaving control (DIC) strategy that acts on local current measurements at every converter and achieves communication-free PWM interleaving among the series-stacked converters. The proposed controller is simple in structure and is shown to converge asymptotically to the interleaved state irrespective of clock drifts among the digital signal processors. Experimental results are provided for a system of five series-connected converters showing a 10× reduction in the current ripple compared to normal operation.

cascaded converter↗

Small-Signal Stability of Grid-Forming Converters Under Fault Conditions

Threshold virtual impedance (TVI)-based current limiting for grid-forming converters (GFMs) has gained great interest due to its ability to maintain voltage source behaviour during faults. However, sequence component extraction (SCE) and negative-sequence control (NSC) are often overlooked in small-signal stability assessments during faults. This paper develops small-signal sequence impedance models for GFMs under four well-known SCE methods based on TVI current limiting control during symmetrical fault conditions. Using the developed impedance models, the impacts of SCE and NSC, and the voltage and current control loop bandwidths, on system stability during faults are investigated. Additionally, since negative-sequence TVI (TVI-) is typically added along with its positive-sequence counterpart, which is often inductive, inductive and resistive TVI- are examined. The findings suggest that a higher voltage or current control loop bandwidth has a negative impact on system stability, while SCE and NSC largely reduce the stable range for voltage and current control loop bandwidth during faults, and that the severity of such impacts is determined by the particular SCE method. Furthermore, it is observed that inductive TVI- significantly degrades system stability, while resistive TVI- can enhance stability when suitable SCE methods are appropriately selected and designed. Matlab/Simulink electromagnetic transient simulations validate these analytical results.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Progress on Machine Learning for the SNS High Voltage Converter Modulators

The High-Voltage Converter Modulators (HVCM) used to power the klystrons in the Spallation Neutron Source (SNS) linac were selected as one area to explore machine learning due to reliability issues in the past and the availability of large sets of archived waveforms. Progress in the past two years has resulted in generating a significant amount of simulated and measured data for training neural network models such as recurrent neural networks, convolutional neural networks, and variational autoencoders. Applications in anomaly detection, fault classification, and prognostics of capacitor degradation were pursued in collaboration with the Jefferson Laboratory, and early promising results were achieved. This paper will discuss the progress to date and present results from these efforts.

Pappas, Chris↗

The BiDFET Device and Its Impact on Converters

The matrix converter topology for direct ac-to-ac conversion offers elimination of the bulky and unreliable D.C. link capacitors used in the popular Voltage-Source Inverter (VSI) with a front-end rectifier. The resulting more compact and higher efficiency implementation is a desirable solution for a wide variety of applications, such as photovoltaic energy generation, motor drives, and energy storage systems. The development of matrix converters has been hampered by the lack of availability of commercial bidirectional power switches with the ability to block high voltages in the first and third quadrants, carry on state current in both quadrants with low voltage drop, exhibit large forward-biased safe-operating-area (FBSOA), and low switching power losses. Consequently, many implementations have been tried in the past using discrete devices, as listed in Table I. Two implementations utilize commonly available asymmetric blocking IGBTs, while two cases make use of SiC power MOSFETs. They generally have a large parts count (4-6 individual switches) that occupies significant space in the converter where multiple bi-directional switches are required. They also have a high on-state voltage drop that degrades efficiency. As a result, one implementation utilizes symmetric blocking IGBT to achieve a low parts count (2), but its switching losses are unacceptably high.

42 ENGINEERING↗

Application of Convolutional and Feedforward Neural Networks for Fault Detection in Particle Accelerator Power Systems

High voltage converter modulators (HVCM) provide power to the accelerating cavities of the spallation neutron source (SNS) facility. HVCM experience catastrophic failures, which increase the downtime of the SNS and reduce beam time. The faults may occur due to different reasons including failures of the resonant capacitor, core saturation due to the magnetic flux, insulated-gate bipolar transistor (IGBT) failures, and others. We recently have setup a HVCM test stand to develop and test machine learning models for anomaly detection and fault prognostics. In this work, we propose binary classifiers and autoencoder architectures based on convolutional (CNN) and feedforward neural networks (FNN) to facilitate distinguishing normal from faulty waveforms coming from the HVCM during operation. The results indicate that the CNN binary classifier is the best model among the four showing very stable performance in the training and testing sets with impressive metrics of precision and recall reaching up to 99\% with a very small uncertainty. The FNN classifier shows the least performance with a large uncertainty in its metrics. The performances of the two autoencoders based on CNN and FNN were in between, showing very good performance nonetheless.

Radaideh, Majdi↗

Comprehensive Comparative Analysis: VSI-based vs. CSI-based Motor Drive Systems with Sinusoidal Output Voltage

The emergence of wide-bandgap (WBG) power devices opens opportunities for current source inverters (CSIs) to provide a promising alternative drive configuration for motor drive applications. The sinusoidal output voltage of CSI offers significant advantages for numerous motor drive applications, including reducing the risks associated with motor terminal overvoltages and bearing discharge currents. This paper compares the performance of CSIs and voltage source inverters (VSIs) with the same performance capabilities. More specifically, sine filters are added to the VSI output terminals to match the CSI performance, and a front-end boost converter is added to the VSI to match the CSI’s voltage-boost capability. The results show that the CSI active components require 48% less volume than the VSI, combined with other performance advantages that make it an appealing candidate for some future motor drive applications.

current source inverter, motor drive system, passi↗

Device Voltage Stress from Ground Leakage Current in Medium-Voltage Solid-State Transformer

Grounding related issues are critical for safe and reliable operation of solid-state transformer (SST) in medium-voltage (MV) applications, e.g., solar photovoltaic and energy storage integration, date center, electric vehicle fast charging, etc. This article presents for the first time the issue of additional device voltage stress due to grounding-loop current in current-source SST, using the soft-switching solid-state transformer (S4T) as an example. The S4T features single-stage isolated AC-AC, AC-DC, or DC-DC conversion with full-range ZVS, derived from flyback converter or current-source converter (CSC). However, the flyback operation for CSC-based SST means that magnetizing current flows through the reverse-blocking devices on only one side of the medium-frequency transformer (MFT) at a time. Then, the voltages across the devices, especially those on the other side of the MFT, can be influenced by parasitic current. A parasitic model of a modular S4T (M-S4T) prototype is developed from direct measurements and datasheets. Using the developed parasitic model and equivalent circuits, the causes of the voltage stress are analyzed. A voltage-stress mitigation scheme of connecting additional grounding capacitors is proposed. Damping resistors are also installed to damp out the grounding-loop resonance. A robust parameter design of the proposed scheme is given. The existence of the voltage stress issue and the effectiveness of the proposed scheme are verified experimentally on an MV SiC M-S4T prototype with inherent parameter variations among the five modules in the prototype. Here, both single-module and stacked-module operation are demonstrated during steady state and dynamic conditions up to 4 kV peak.

42 ENGINEERING↗

Deep Learning-Based Dynamic Modeling of Three-Phase Voltage Source Inverters

Inverter-based resource (IBR) models are necessary to analyze modern power system stability and create effective control strategies. Modeling IBRs in converter-rich power systems is crucial, yet challenging due to the lack of commercial information on converter topologies and control parameters. This paper proposes novel convolutional neural network (CNN)–based data-driven techniques for modeling IBRs, addressing adaptability and proprietary concerns without requiring internal system physics knowledge. The proposed method is tested using real grid-tied commercial IBR transient data and demonstrates effectiveness and accuracy. Furthermore, the developed modeling approach is integrated and implemented in the open-source power distribution simulation and analysis tool, GridLAB-D, to illustrate the potentiality of dynamic analysis of large-scale power systems with high IBRs.

deep learning, artificial intelligence↗

Dynamic Phasor Modeling of Three Phase Voltage Source Inverters

With the increase in the development and implementation of distributed energy resources, application of parallel connected inverters is increasing and as a result having accurate modeling and simulation tools that can help in the design, analysis and stability assessment of the grid is of great importance. Development of fundamental methods that can achieve accurate, reliable, and computationally efficient results can be very beneficial. Application of Dynamic phasor (DP) modeling method has been limited to study of limited harmonics and small combination of interconnected converters due to the complexity associated with developing models that describe larger systems. In this paper, application of DP modeling method is expanded to model any number of parallel connected three phase voltage source inverter (VSI) with inclusion of a wider harmonic content including fundamental, subharmonics, inter-harmonics, switching frequency and their sidebands. Results achieved from this modeling method is compared with conventional average model as well as detailed switching model and the effect of inclusion of wider harmonic content on accuracy of DP modeling method is demonstrated.

Xue, Yaosuo↗

New Modulation and Impact of Transformer Leakage Inductance on Current-Source Solid-State Transformer

This article presents a novel modulation scheme for device voltage stress mitigation and comprehensive analysis of the impact of transformer leakage inductance in a current-source solid-state transformer (SST). Different from dual active bridge (DAB) SST, the operation of the current-source SST is similar to that of a flyback converter. The device bridge on only one side of the transformer is active to store energy into or release energy from the magnetizing inductance which acts as a current-source dc link. Such flyback operation with reverse-blocking switches can lead to additional device voltage stress and incomplete zero-voltage switching (ZVS) on the current-source soft-switching solid-state transformer (S4T) under conventional modulation. A new modulation scheme is proposed to address this issue. Moreover, different from the DAB, the leakage inductance of the medium-frequency transformer (MFT) in the S4T is a parasitic element similar to that in a matrix SST and can cause additional device voltage stress. Though the resonant capacitors, originally added to achieve ZVS, can absorb and recycle the leakage energy in the S4T, these capacitors need to be increased with larger leakage inductances to limit the voltage stress. However, large resonant capacitors can result in more lost duty cycles and reduced efficiency. The impact of such leakage inductance on device voltage stress is analyzed comprehensively, which is critical to guide future research and design of the S4T. Experimental results from S4T prototypes for DC-DC, multiport AC-DC, and AC-AC conversion with 1:1 and 4:1 MFT comprehensively verify the proposed concepts. Lastly, a case study of a three-phase AC-AC S4T over a power range from 1 kVA to 100 kVA each module reveals that the MFT leakage inductance should be less than 1% of the magnetizing inductance for safe operation.

14 SOLAR ENERGY↗

Feed-Forward Compensation for Model Predictive Control in Tri-port Current-Source Medium-Voltage String Inverters for PV-Plus-Storage Farms

The novel tri-port current-source medium-voltage string inverter (TCS-MVSI) is a promising candidate for large-scale PV-plus-storage (PVS) farms owing to its galvanic isolation, easy storage integration, soft-switching capability across entire load range, controlled low dv/dt and EMI, benign fault tolerance, etc. Due to its low inertia feature, traditional PI-based control cannot manage large transients effectively. Instead, a model-based predictive control (MPC) is proposed to achieve robust and stable operation. As is well known, the control performance of MPC is compromised by the sampling and computational delay during implementation significantly, if not well addressed. This paper analyzed and quantified these delays and then proposes feed-forward compensation (FFC) for the MPC method to compensate the delays and the large parameter variations due to the low-inertia nature. In addition, this method also compensates for the high dc-link ripple within each switching cycle, a unique issue for low-inertia converters. Here, the proposed method requires low computational effort, allowing it to be extended for multiple ports. The effectiveness of the proposed method has been validated in experiments. In 10 kW test, the proposed method decreases the average dc-link current by 17%, leading to ~20% conduction losses and ~0.5% increase in converter efficiency. In addition, the peak dc-link current also decreases by 15%, resulting in reduced transformer size. As a result, an increased power density can be achieved with the proposed method. Similar improvements have been observed across the power range from 2 kW to 10 kW.

30 DIRECT ENERGY CONVERSION↗

Single DC Source Based Cascaded Multilevel Inverter

The objective of this project is to develop a high-efficiency solid-state transformer that converts a fixed DC voltage to a medium-voltage AC for utility distribution network connections without having the conventional low-frequency bulky transformers and switch gears. The initial target of 99% efficiency was achieved with the use of wide bandgap semiconductor devices using a proposal novel multilevel inverter. The medium-voltage was successfully tested at 7.2/12.47 kV phase/line voltage level for a 100-kW three-phase inverter.

14 SOLAR ENERGY↗

High frequency medium voltage drive system for high speed machine applications

In one aspect, a medium voltage power converter includes a plurality of slices each having: a transformer including a plurality of primary windings to couple to a utility source of input power and a plurality of secondary windings; and a plurality of power cubes coupled to the plurality of secondary windings, each of the plurality of power cubes comprising a low frequency front end stage, a DC link, and a high frequency silicon carbide (SiC) inverter stage to couple to a high frequency load or to a high speed machine.

Ledezma, Enrique↗

Assessing Dynamic Behaviors in Converter- Dominated Power Systems via RMS and EMT Simulations: A Study of Hawaii’s NELHA Microgrid

The transition from conventional power systems to converter-based microgrids has significantly advanced sustainability, clean energy integration, and operational reliability. However, this paradigm shift introduces operational challenges due to the intermittent nature of renewable energy sources and the non-linear characteristics of power electronic loads, inducing voltage fluctuations and harmonic distortions that complicate voltage and frequency regulation. Accurate dynamic modeling is hypothesized to be critical for capturing such effects, enabling reliable simulation and control strategy development. This study introduces an innovative dynamic modeling framework for a real-world converter-based microgrid, utilizing both root mean square (RMS) and electromagnetic transient (EMT) simulation methods. The microgrid was modeled in DIgSILENT PowerFactory, with simulations calibrated against high-resolution field measurements from SEL-735 power quality meters. Results show that RMS simulations effectively characterize steady-state dynamics, while EMT simulations are essential for capturing high-frequency transients and non-linear effects from photovoltaic inverters and variable frequency drives (VFDs). This complementary approach provides a comprehensive understanding of microgrid behavior, providing critical insights for improving simulation accuracy, advancing protection schemes, and improving resilience in future low-inertia power networks.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Solid State Transformer Controls for Mitigation of E3a High-Altitude Electromagnetic Pulse Insults

This paper explores the use of a solid state transformer (SST) to mitigate the 𝐸 3𝐴 component of a high-altitude electromagnetic pulse (HEMP) insult using external energy storage optimal control techniques. In lieu of conventional passive blocking devices or feedback-controlled energy storage devices, a novel implementation of Hamiltonian error tracking is utilized to develop a feedback control law for the variable converter ratio in an SST. The findings of the simulations performed in this paper suggest that additional energy storage is not necessary to protect an individual load from a HEMP insult. The simulations performed examine the response of a single-phase SST connected to a single voltage source on a long transmission line on the one side and a single linear resistor on the other. The control law is specifically developed for the late-time, low-frequency portion of a HEMP insult, namely the 𝐸 3𝐴 components. The Hamiltonian error-based converter ratio control law is compared with nonlinear optimal feedforward controls to show that the HSSPFC is an external energy storage optimal controller.

HEMP mitigation↗

Machine Learning for Improved Availability of the SNS Klystron High Voltage Converter Modulators

Beam availability has increased at the SNS, however, the targeted availability is greater than 95 %, while the SNS has failed to meet lower targets in the past. The HVCM used to power the linac klystrons have been one source of lost beam time and was chosen to explore using AI/ML techniques to improve reliability. Among the possibilities being explored are automating the tuning of HVCMs and predicting component failures such as capacitor aging, rectifier assemblies containing hundreds of diodes, and insulating oil degradation. The methodology pursued includes data cleaning, de-noising, post-analysis data labeling, and machine learning model development. We explore using Long Short-Term Memory and autoencoders for anomaly detection and prognostication used to schedule maintenance. We evaluate the use of model regularizers and constraints to improve the performance of the model and investigate methods to estimate the uncertainty of the models to provide a robust prediction with statistical interoperability. This paper describes the operational experience and known failures of the HVCMs and the proposed ML methodology and the preliminary results of training the AI/ML algorithms.

Pappas, G. C.↗