At least 55 records · Page 3

Stem Inc. SunShot Incubator Program Final Technical Report

In this Energy Storage Control Algorithms project, Stem sought to develop tools and control algorithms to increase the value and reduce balance-of-system and grid integration costs associated with adding distributed solar generation to the grid. These advances fell under the headings SolarScope and SolarController. Stem sought to create initial market traction with a fully commercialized product for the solar industry to size storage systems (SolarScope) as well as a solar intermittency-mitigation framework for utilities (SolarController) in the course of the project. The company sought to align strategic growth plans and enable the rollout of the products to broader audiences in multiple geographic regions by leveraging the major solar companies in the national market as partners. Both final products were both intended to be commercialized. They are: SolarScope: Analysis tool to identify viable PV + storage projects and thereby expedite the sales and interconnection processes. SolarScope combines customer load data, PV production estimates, utility rate tariff, and simulated storage into a simple user interface for PV developers. Developers can easily identify viable solar + storage sites without the need for complex and time consuming, site-by-site spreadsheet modeling. SolarContoller: Tool to autonomously dispatch distributed storage in order to mitigate voltage fluctuation and reduce curtailment. SolarController co-optimizes, in real time, storage dispatch for circuit stability and curtailment reduction, enabling higher penetrations of PV. SolarController is automated, not requiring utility dispatch or management, as Stem hardware senses grid voltage, frequency, customer load, PV production, and power factor. In the end the two products met with different outcomes. SolarScope was tested by potential users, and continues to be used as a foundational platform for partnership with key solar industry partners. SolarController, on the other hand, was successful in lab testing but was not commercialized due to a lack of marketability and lack of interested customer base. Together the development of these two products marked a material step forward for Stem; and a new milestone along the pathway of integration for the solar and storage industries. SolarScope is leading to real, out-of-the-lab project development in storage + solar for the commercial customer sector. Meanwhile SolarController has opened the eyes of regulators and utility executives alike to the potential of distributed solar and by doing so, has moved the conversation forward for the integration of distributed energy resources more broadly on the grid.

25 ENERGY STORAGE↗

A Two-Step Restoration Scheme with DER Controllability for Resilient Distribution Systems

Modern distribution systems have increasing integration of distributed energy resources (DERs). A large number of distribution system DERs are interfaced through a power electronic converter. During grid contingency scenarios these resources have been traditionally disconnected, without any fault ride-through capabilities. However, with new regulations and better technology, it is feasible for these resources to contribute to the grid's restoration after an adverse event and hence enhancing resilience. In distribution systems, system restoration is an important problem, especially in face of high-impact low-frequency events. This paper proposes a two-step restoration scheme for the power system restoration process by leveraging additional degrees of freedom in DERs for mitigating voltage problems. Simulation studies are performed on the IEEE-123 node feeder system to demonstrate the effectiveness of the proposed method for various cases.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Elucidating and Mitigating High-Voltage Degradation Cascades in Cobalt-Free LiNiO 2 Lithium-Ion Battery Cathodes

LiNiO 2 (LNO) is a promising cathode material for next-generation Li-ion batteries due to its exceptionally high capacity and cobalt-free composition that enables more sustainable and ethical large-scale manufacturing. However, its poor cycle life at high operating voltages over 4.1 V impedes its practical use, thus motivating efforts to elucidate and mitigate LiNiO 2 degradation mechanisms at high states of charge. Here, a multiscale exploration of high-voltage degradation cascades associated with oxygen stacking chemistry in cobalt-free LiNiO 2 , is presented. In this work, lattice oxygen loss is found to play a critical role in the local O3–O1 stacking transition at high states of charge, which subsequently leads to Ni-ion migration and irreversible stacking faults during cycling. This undesirable atomic-scale structural evolution accelerates microscale electrochemical creep, cracking, and even bending of layers, ultimately resulting in macroscopic mechanical degradation of LNO particles. By employing a graphene-based hermetic surface coating, oxygen loss is attenuated in LNO at high states of charge, which suppresses the initiation of the degradation cascade and thus substantially improves the high-voltage capacity retention of LNO. Overall, this study provides mechanistic insight into the high-voltage degradation of LNO, which will inform ongoing efforts to employ cobalt-free cathodes in Li-ion battery technology.

25 ENERGY STORAGE↗

Towards extreme fast charging of 4.6V LiCoO 2 via mitigating high-voltage kinetic hindrance

High-voltage LiCoO 2 (LCO) is an attractive cathode for ultra-high energy density lithium-ion batteries (LIBs) in the 3C markets. However, the sluggish lithium-ion diffusion at high voltage significantly hampers its rate capability. Herein, combining experiments with density functional theory (DFT) calculations, we demonstrate that the kinetic limitations can be mitigated by a facial Mg 2+ +Gd 3+ co-doping method. The as-prepared LCO shows significantly enhanced Li-ion diffusion mobility at high voltage, making more homogenous Li-ion de/intercalation at a high-rate charge/discharge process. The homogeneity enables the structural stability of LCO at a high-rate current density, inhibiting stress accumulation and irreversible phase transition. When used in combination with a Li metal anode, the doped LCO shows an extreme fast charging (XFC) capability, with a superior high capacity of 193.1 mAhg -1 even at the current density of 20C and high-rate capacity retention of 91.3% after 100 cycles at 5C. In conclusion, this work provides a new insight to prepare XFC high-voltage LCO cathode materials.

25 ENERGY STORAGE↗

ION PRODUCTION AND MITIGATION IN DC HIGH-VOLTAGE PHOTO-GUNS

One of the biggest obstacles to operating a GaAs polarized electron source with a long charge lifetime is the mitigation of ion back-bombardment. Several techniques exist to either clear ions from the accelerator or to mitigate ion damage of the photocathode. Predicting the effectiveness of these techniques requires sophisticated simulation models of electron impact ionization within the photo-gun. In this work, the effectiveness of applying a positive anode bias voltage to mitigate ion damage and increase the charge lifetime of the GaAs photocath?ode was studied over three run periods at the Continuous Electron Beam Accelerator Facility (CEBAF) at Jefferson Lab (JLab). The charge lifetime with the biased anode configuration was 1.80±0.51 times longer than the lifetime of the usual grounded anode configuration. Sim?ulations of ionization within the CEBAF photo-gun and adjacent beamline were made using General Particle Tracer (GPT) and a new C++ custom element to predict and explain the substantial improvement in charge lifetime. The experimental results and the development of the ionization custom element, with its use in simulations of ion back-bombardment with the biased anode, are described in detail.

Yoskowitz, Joshua↗

A Model-Free Voltage Control Approach to Mitigate Motor Stalling and FIDVR for Smart Grids

Electric power networks are large and highly nonlinear dynamical systems that present unique challenges to control design. Though there is a large number of dynamic models for power system stability and control, many models are only useful with right assumptions and wrong for other tasks. Moreover, the dynamic behavior of the grid is increasingly complex under the banner of smart grids. These lead to the difficulty of developing appropriate dynamic modeling, and thus an efficient control strategy. To avoid such modeling challenges, here we present a novel dynamic voltage control strategy based on a model-free control (MFC) approach, requiring no modeling procedure. In particular, it focuses on fault-induced delayed voltage recovery (FIDVR) events, which require complex and accurate dynamic load models to replicate such events. This work utilizes MFC as an online controller to achieve the desired voltage stability under the FIDVR event. The proposed MFC strategy allows simple implementation and low computational cost for efficient mitigation of FIDVR. For benchmarking, a reasonably accurate dynamic performance model is explored. Simulation results with the IEEE 57 bus test network demonstrate the enhanced dynamic voltage profile for load buses having induction motors with the support of reactive power resources.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Residential Advanced Photovoltaic Inverter Pilot Study Results for Select Distribution Secondaries in Hawai'i

Penetration levels of residential rooftop solar photovoltaic (PV) generation on the Hawaiian island of O'ahu have increased significantly in recent years, with many circuits now at the limits of their PV hosting capacity. NREL and Hawaiian Electric have used this opportunity to deploy advanced inverters at new customer installations that would not otherwise have been approved, as a pilot study to gain first-hand operational field data and experience on the impact of inverter-based grid support functions. At each customer location, the deployed advanced inverters were remotely controlled and monitored. Additionally, customer AMI (smart meter) and secondary distribution transformer data was also available for the analysis. The analysis focused on quantifying the customer behind-the-meter voltage rise due to PV production, determining the customer voltage rise with advanced inverters in unity power factor as well as advanced grid support function modes, and estimating the curtailment when inverters have Volt-VAR and Volt-Watt enabled. The results show that: 1) Behind-the-meter voltage rise is often not negligible. 2) An inverter's operating point on a Volt-VAR/Volt-Watt curve depends strongly on the design of the secondary system on which it is installed. 3) The mitigation of voltage rise on the secondary system using Volt-VAR may not be effective if only a small proportion of inverters have grid support enabled, or if the reactance/resistance (X/R) ratio of the grid is low. 4) Volt-Watt curtailment can be estimated using co-located irradiance sensors but there may be opportunities to estimate it using inverter internal electrical measurements. 5) Estimated curtailment is very low for the locations analyzed to date.

14 SOLAR ENERGY↗

A High Voltage Power Supply That Mitigates Current Reversals in Capillary Zone Electrophoresis-Electrospray Mass Spectrometry

Capillary electrophoresis coupled with electrospray ionization typically employs two power supplies, one at each end of the capillary. One power supply is located at the proximal (injection) end of the capillary. The power supply located at the distal (detector) end of the capillary drives the electrospray. Electrophoresis is driven by the difference in potential between these power supplies. Separations that employ large capillary inner diameter, high conductivity background electrolyte, and high separation potentials generate higher current than that produced by the electrospray. Excess current flows through the electrospray power supply. Most power supplies are not designed to sink current, and the excess current will cause the electrospray voltage to deviate from its set point. We report a simple circuit to handle this excess current, allowing separations under a wide range of electrophoretic conditions. .

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Mitigation of fault related voltage swell on distribution feeders using DER-based advanced inverter controls

Unbalanced faults in distribution feeders can impact voltages on the non-faulted phases. This paper models a real-life feeder with a high penetration level of solar photovoltaic (PV) units in detail including the secondary circuits, and shows a large voltage swell in one of the non-faulted phases of the feeder during a single line to ground fault. The voltages seen during this swell are more than 1.2 p.u., which can have detrimental impacts on the connected equipment and can also lead to loss of connected generation. The reason for this voltage swell is found to be the equivalent impedance at the fault location resulting from the ratio of zero and positive sequence cable impedances. It is seen that the connected solar PV units with appropriate control are able to reduce the severity of the voltage swell, especially for higher penetration levels of solar PV considered, but not entirely eliminate it.

14 SOLAR ENERGY↗

AC and DC Fault Management for Megawatt Electrified Aircraft Electrical Powertrains - Task 2: Power Quality Filtering Using Nanocrystalline Soft Magnetic Inductor

The NASA RTAPS program on AC and DC Fault Management for Megawatt Electrified Power Train is a multi-year joint project with Pratt & Whitney (P&W), Collins Aerospace (CA), and RTX Technology Research Center (RTRC). This research program focuses on the high-voltage distribution issues that present a significant technological obstacle in the adoption of Electrified Aviation Propulsion (EAP) systems. One challenge to the adoption of high-voltage distribution systems with power electronic converters is the need for filter elements to limit the generation and propagation of noise, protect the cable systems from premature aging and prevent against excessive heating within subcomponents due to high-frequency induced currents. While increased distribution voltages aide in reducing the cable mass for a fixed power system, the associated mass with the filtering elements for power electronic converter can grow with increasing distribution voltages – thereby mitigating any benefit associated with increasing the distribution system voltage. To enable high-voltage distribution systems with high system specific power densities, new magnetic materials must be developed. Therefore, the second task of the NASA RTAPS program is associated with the design and application of advanced soft magnetic components for Megawatt class electric propulsion systems, specifically the motor drive system. This report covers the collaborative work between NASA Glenn Research Center (GRC), RTRC, P&W and CA in the development of three types of magnetic components over the span of the three-year program. These critical magnetic components are the DC side EMI filter, which limits the propagation of harmful electromagnetic noise to the rise of the distribution system, and the AC side damping with the dv/dt filter, which limits the fast rise time of the power electronic converter output voltage to limit the degradation on the cable/motor insulation systems. Each of these components are investigated from component level design and are optimized at the system level with a combined modelling and testing effort. In the final experimental evaluation of the NASA developed soft magnetic material with a dv/dt filter, a commercial-off-the-shelf (COTS) magnetic core and the GRC magnetic core are optimized and loaded at 320Arms to evaluate their difference in performance. After a run time of 30 minutes in a MW-class motor driver at RTRC, the NASA GRC cores were found to not only offer a lower temperature rise of nearly 25°𝐶, but also a reduction in measured core loss of 25% (12.75W to 9.5W).

Elecrified Aircraft Propulsion↗

Increased Voltage in CdSe Solar Cells by Mitigation of Charge Carrier Trapping Due to Se Vacancies

Cadmium selenide (CdSe), with a 1.7 eV bandgap, is a promising high-bandgap semiconductor for tandem solar cells, yet device efficiencies are hindered by rapid minority carrier recombination. Here, in this study, polycrystalline CdSe solar cells are investigated using radiative emission spectroscopy, time-resolved photoluminescence, and density functional theory, revealing fast (sub-nanosecond) minority carrier trapping by selenium vacancy-related defect states with densities of (5–50) × 10 17 cm −3 , limiting carrier mobility and increasing recombination. By reducing absorber thickness to ≈0.5 µm, trapping effects are mitigated, achieving a record open-circuit voltage of 917 mV, a 165 mV improvement over prior reports. These findings clarify the role of Se vacancies in limiting CdSe solar cell performance and provide insights applicable to CdSe and CdSeTe thin-film photovoltaics. This work advances understanding of defect-mediated losses in II–VI semiconductors and suggests pathways for improving solar cell performance through defect control.

14 SOLAR ENERGY↗

Power Flow Models of Grid-Forming Inverters in Unbalanced Distribution Grids

Load unbalance in electric distribution systems is unavoidable. Unbalanced load currents will lead to negative sequence (NS) voltages that may damage electric equipment. Unbalanced power flow analysis is a common tool to detect and mitigate NS voltage issues and requires accurate models of grid components. While traditional source models are available, grid-forming (GFM) inverter models are not well developed. GFM inverters implement various control strategies, which affect their power flow models. Here, in this paper, a novel GFM inverter model considering control effects is proposed. We show that for some control methods, unbalanced system loading will lead to unbalanced terminal voltages of the GFM inverters, which are modeled through an equivalent negative sequence impedance. The proposed models are initially validated using a simple test circuit. Then, they are applied in the power flow analysis on the IEEE 13-bus and 34-bus systems to demonstrate the accuracy improvement over the state-of-the-art. Using time-domain simulations as benchmarks, we show that the proposed models reduce the calculation error of negative sequence voltages by at least 25% in unbalanced distribution systems.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Voltage decay and redox asymmetry mitigation by reversible cation migration in lithium-rich layered oxide electrodes

Despite the high energy density of lithium-rich layered-oxide electrodes, their real-world implementation in batteries is hindered by the substantial voltage decay on cycling. This voltage decay is widely accepted to mainly originate from progressive structural rearrangements involving irreversible transition-metal migration. As prevention of this spontaneous cation migration has proven difficult, a paradigm shift toward management of its reversibility is needed. Herein, we demonstrate that the reversibility of the cation migration of lithium-rich nickel manganese oxides can be remarkably improved by altering the oxygen stacking sequences in the layered structure and thereby dramatically reducing the voltage decay. The preeminent intra-cycle reversibility of the cation migration is experimentally visualized, and first-principles calculations reveal that an O2-type structure restricts the movements of transition metals within the Li layer, which effectively streamlines the returning migration path of the transition metals. Furthermore, we propose that the enhanced reversibility mitigates the asymmetry of the anionic redox in conventional lithium-rich electrodes, promoting the high-potential anionic reduction, thereby reducing the subsequent voltage hysteresis. Our findings demonstrate that regulating the reversibility of the cation migration is a practical strategy to reduce voltage decay and hysteresis in lithium-rich layered materials.

25 ENERGY STORAGE↗

Estimating Customer Impact of Volt-Watt Using Only Smart Meter Voltage Data

The autonomous inverter control mode known as volt-watt control can be useful as a backstop against high customer voltages outside of the ranges specified in ANSI C84.1 (i.e. above 1.05-1.06 per unit). Volt-watt control mitigates high voltages by directly reducing the active power output of a distributed energy resource based on local voltage measurements. Therefore volt-watt control also can impact the energy produced by the DER (e.g. PV system), especially for customers with persistently high voltages, and in such cases it is difficult to determine exactly how much the DER has been curtailed because it is not generally known exactly how much energy the PV system could have produced. These slides propose a relatively simple method of estimating the DER's energy curtailment using only data from the utility advanced metering infrastructure (AMI) data). The method proves surprisingly accurate when validated against detailed quasi-static time-series simulations and against limited field data.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Deep Reinforcement Scheduling of Energy Storage Systems for Real-time Voltage Regulation in Unbalanced LV Networks with High PV Penetration

The ever-growing higher penetration of distributed energy resources (DERs) in low-voltage (LV) distribution systems brings both opportunities and challenges to voltage support and regulation. This paper proposes a deep reinforcement learning (DRL)-based scheduling scheme of energy storage systems (ESSs) to mitigate system voltage deviations in unbalanced LV distribution networks. The ESS-based voltage regulation problem is formulated as a multi-stage quadratic stochastic program, with the objective of minimizing the expected total daily voltage regulation cost while satisfying operational constraints. While existing voltage regulation methods are mostly focused on onetime- step control, this paper explores a day-horizon systemwide voltage regulation problem. In other words, the size of action and state spaces are extremely high-dimensional and need to be delicately handled. Furthermore, in order to overcome the difficulty of modeling uncertainties and develop a realtime solution, a learn-to-schedule feedback control framework is proposed by adapting the problem to a model-free DRL setting. The proposed algorithm is tested on a customized 6-bus system and a modified IEEE 34-bus system. Simulation results validate the effectiveness and near-optimality of voltage regulation by ESS in comparison with a deterministic quadratic program solution.