Variability and Diversity Load Model Tool [SWR-20-03]

The motivation for the development of this tool and the underlying algorithms and methods was to enable the development of high-temporal resolution, realistic time-series data for quasi-static time-series (QSTS) analysis of distribution systems. Often, aggregated load profile data for a distribution circuit is available (e.g. feeder loading data collected via SCADA at the utility substation) and, while this data is typically accurate it masks the considerable variability of the 100’s or 1000’s of individual loads connected on the circuit. This tool was developed to model both the increased variability expected for these individual loads (e.g. the load of a single distribution transformer connected to 8-12 houses) and the expected diversity between loads on the circuit. It is important to note that the difference in variability and diversity, in the context of this tool, is that variability modeling only adds representative variability due to disaggregated load characteristics (e.g. the presence in the load profile of loads turning off and on like an air conditioner/oven) while the average energy profile remains the same as the user supplied power profile. Diversity modeling generates multiple individual load profiles which, in aggregate, sum to the user supplied power profile. Diversity is effectively variability in the energy usage over longer periods of time than seen in the variability model. Put another way, variability modeling supplies the expected variability due to the operation of various end-use loads and diversity modeling supplies the usage differences due to human behavior, schedules, etc. This load modeling tool was developed for use in generating data for distribution systems. Modeling is summarized by two major functions: 1) taking low resolution load profiles and adding intra-seconds variability onto the profiles, and 2) taking a user supplied load profile and distribution factors and adding both diversity and variability to the user supplied profile.

Zhu, Xiangqi↗

A Hybrid AI/ML and Computational Mechanics Based Approach for Time-Series State and Fatigue Life Estimation of Nuclear Reactor Components

Environmental fatigue modeling is a complex problem due to multiple failure modes and their intermixing. The failure modes are function of various underlying causes in addition to the corrosive effect of reactor coolant environment. Some of the major causes are time-dependence of material associated with cyclic loading, load sequence effect associated with random/variable amplitude loading, effect of strain amplitude and rates, effect of varying temperature (along both temporal and spatial directions) and the effect of mean strain and stress. The nonlinear intermixing of failure modes associated with above mentioned causing parameters makes the environmental fatigue modeling is a challenging task. Because of this challenge, fatigue is traditionally being modeled based on experimental data. However, test based empirical approach often requires hundreds of fatigue tests to model the above-mentioned intermixing failure causes even for a single material system. The problem is further exaggerated for reactor component made from multi-material systems such as made from both carbon and stainless-steel base metals and their similar and dissimilar metal welds. With the difficulty of conducting hundreds of fatigue tests to capture the above-mentioned intermixing failure causes, fatigue modeling approaches often depends on empirical models based on limited available test data such as available through ASME code and NUREG 6909. However, these limited test-data-based models may not be enough to accurately predict the life of reactor components. Accurate prediction of life of reactor component would become a necessity, particularly when the license of the reactors to be extended for long-term-operation (LTO) that is for well beyond its original design life of 40 years. The requirement of extending the license of reactor under LTO requires hundreds of fatigue tests to be conducted to understand the mechanism associated with the above-mentioned interdependent failure causes. However, conducting large number of fatigue tests is not a feasibility due to the cost involved. To address this issues Argonne National Laboratory (ANL) with the sponsorship of DOE Light Water Reactor Sustainability (LWRS) program trying to develop a hybrid predictive modeling approach. This is based on limited experiment-data, Artificial-intelligence (AI) – Machine-Learning (ML) - Deep-Learning (DL) based techniques and Multiphysics-computational-mechanics based modeling tools. The hybrid approach not-only can improve the accuracy of the existing stress analysis and fatigue modeling approach but also can reduce the over-dependency on test-based approach. Towards this goal following are some of the major contributions based on ANL’s FY-20 environmental fatigue modeling activities: 1) A cyclic plasticity material model database for 82/182 dissimilar metal weld, which can be readily shared with US nuclear industry and regulatory agency on request. 2) A well validated analytical modeling methodology to perform cycle-by-cycle stress prediction under both constant amplitude fatigue loading and variable amplitude fatigue loading (with load-sequence effect). 3) An AI/ML/DL based methodology to predict unmeasurable cyclic strain based on other available sensor signals. This type of approach can be used for estimating strain in real reactor components from other sensor readings. 4) An AI/ML based approach to improve the US capability on environmental fatigue testing. This is by improving ANL’s existing environmental fatigue testing capacity to conduct ASME required strain-controlled tests (by controlling strain amplitudes and its rate), while not measuring the strain (due to the difficulty of placing an extensometer in a narrow autoclave in a PWR-water-test system). 5) A simulation and experiment based probabilistic modeling methodology for time-series fatigue state and life estimation of reactor metal such as dissimilar metal weld.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

What Is the Value of Alternative Methods for Estimating Ramping Needs?

Power system operators procure and deploy flexibility reserves or ramping products to address balancing needs caused by uncertainty and variability of load and generation. Existing methods estimate ramping needs using calendar information and historical forecast errors. Novel methods investigate if real-time weather information could inform ramping and other balancing requirements. This paper compares estimation methods for ramping requirements in theory and practice. The theoretical framework indicates when an alternative method could yield improved economic or reliability performance than existing methods by requiring lower or higher levels of ramping products. Preliminary simulations on a 118-bus test system for 4 days in May 2019 illustrate how system performance improves or deteriorates when ramping requirements are weather-informed (alternative) instead of calendar-based (baseline). Preliminary results suggest high variability in change of performance and underline the impact of additional factors, such as system conditions, on the realized performance change.

41 EE - Solar Energy Technologies Office (EE-4S)↗

Robust Combined Heat and Hybrid Power (CHHP) for High Electrical Efficiency Cogeneration

Georgia Tech (Prime Recipient), the University of Texas at El Paso (UTEP) and the National Energy Technology Laboratory (NETL) investigated a hybrid fuel cell/ gas turbine system concept as a combined heat and hybrid power (CHHP) system for both robust and high power-to-process heat ratio cogeneration. The novelty of the proposed system entailed the distinct, elevated electrical efficiencies it maintains while simultaneously supporting a broad span of heating needs (e.g., supply temperatures) demanded across variable heat loads. The scope included: 1) leveraging a pioneering national lab facility configured for dynamic system operability development of hybrid fuel cell/gas turbine cycles; 2) enabling technology development to adjust and modulate the quality and quantity of thermal supply to bottoming heat loads via novel extreme temperature gas bypass valves. Hybrid fuel cell/gas turbine systems have primarily been reduced-to-practice in a constrained (e.g., initial proof-of-concept) manner and have still demonstrated considerable electrical efficiencies. However, these pre-pilot systems have focused upon electrical efficiencies and electrical power generation as the exclusive energy demand. Such hybrid systems had not been extensively researched or developed for flexible and variable operation consisting of both power and heat demands; however, these variable combined power and heat demands are characteristic of many types of manufacturers such as animal/poultry processing, bakeries and milk/flour/pastry manufacturing, textile mills, and electrochemical processing. Commercially, developing the system into a working combined heat and power system benefits these types of manufacturers by allowing them to meet their power and heat demands at a lower cost, higher efficiency, and/or through onsite generation. Therefore, the technical scope of this project was largely to study and facilitate these hybrid systems as combined heat and hybrid power (CHHP) systems that include dynamic operability for variable heat and power loads and/or grid dynamics for various types of manufacturers. Simulation results were used to predict the performance of the CHHP system and conceptually develop it to achieve desired dynamic operability. Experimentally, the primary goal was to design, manufacture, and experiment upon a high-temperature bypass valve. Experimental data included air mass flow rates through the valve orifice when the valve was changed to variable extent between fully closed and fully open. The experimental data was then used to create a semi-empirical computational model of the bypass valve. Concluded simulation goals for the research included developing computational heat exchanger models for the hybrid system inclusive of the bottoming heat exchanger and the recuperative heat exchanger, and then combining the computational recuperator model with the computational valve model. Afterwards, the computational models were then integrated to predict the dynamic operation of hybrid fuel cell/gas turbine cycles throughout a design space and reporting such. The scope stated in the preceding paragraph was packaged into five specific goals: 1) enabling the simulation of dynamic combined heat and power through the creation of computational, modular heat exchanger models; 2) simulation and exploration of the CHHP system’s performance by integrating the heat exchanger models with the national lab’s pre-existing hybrid system (computational) simulation, but without the recuperator bypass valve concept in order to initially determine how the (baseline) system behaves and can be controlled in order to meet variable heat and power demands; 3) development and initial deployment of the high-temperature recuperator bypass valve technology in order to confirm and characterize the approach; 4) usage of the experimental data for the valve to create a semi-empirical computational model for the bypass valve which could then be combined with the heat exchanger computational models; 5) repeat of the second task of simulating and exploring the system’s performance, but this time including the bypass valve to resolve its efficacy. Tasks were successfully completed, and the general notion of flexibly operating, high electrical efficiency CHHP was further corroborated. Supportive details are provided in the report.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

2.1.2.403 - Fatigue and Structural Load Analysis and Control for Variable-Geometry Wave Energy Converters (VGWECs)

The VGWEC project will generate and disseminate the foundational knowledge enabling a paradigm shift in the design of wave energy converters (WECs) by adding a geometry control option on top of power-take-off load control. The variable-geometry modules (VGMs) provide control over a WEC's hydrodynamics that can emphasize power absorption or load shedding. Additional load shedding provided by the VGMs is expected to reduce the device structural mass and extend the sea state operating envelope, by limiting peak loading, both contributing towards reducing levelized cost of energy (LCOE) estimates.

hydrodynamic↗

Hydrodynamics and Load Shedding Behavior of a Variable-Geometry Oscillating Surge Wave Energy Converter (OSWEC)

In order to improve their long-term viability, wave energy converters (WECs) need to be able to shed loads when a threshold wave condition is exceeded. As shown by Tom et al. (2016) [1], provision of adjustable flaps within the body of an oscillating surge wave energy converter (OSWEC) allows wave energy to pass through the device. A control system may then be able to open and close the flaps when waves approaching the device exceed preset thresholds. The variable-geometry OSWEC (VG-OSWEC) concept studied in this paper is a bottom-hinged, rectangular wave paddle with five flaps of elliptical cross-section embedded into the face of the paddle. System ID tests were conducted on this VG-OSWEC device at a 1:14 scale in a wave basin. Free decay tests showed that the damping was distinctly nonlinear when the flaps were fully open, and the natural frequency increased by 40% when compared with the flaps in a fully closed configuration. Tests with regular wave conditions were used to develop the response amplitude operator for the rotational motion about the hinge. These response amplitude operator results when compared with numerical simulations run using WEC-Sim/WAMIT and ANSYS AQWA, show strong agreement with the flap open and closed conditions. The regular-wave condition measurements also show that the wave excitation moment about the hinge was reduced by up to 60% when the flaps were fully open. The experiments serve to demonstrate the potential of the variable geometry design to shed loads and survive harsh ocean environments.

load shedding↗

Advanced Reactors Integrated Energy System: Thermal Energy Storage Island Design

The main topic of this research is integrated energy systems (IES) designed for pairing industrial thermal energy loads with advanced reactors (ARs). The Idaho National Laboratory (INL) Crosscutting Technology Development IES program and the National Reactor Innovation Center (NRIC) are seeking to develop, design, and construct an AR-IES demonstration platform that couples the thermal output from an AR operating at the INL/NRIC Demonstration of Microreactor Experiments (DOME) test bed in the Experimental Breeder II dome to a variable capacity load emulator (i.e., air-cooled radiator) and sensible thermal energy storage (TES) via a molten salt thermal energy transfer fluid. In the rapidly evolving landscape of energy supply and distribution, flexibility has emerged as a prized attribute, surpassing the traditional notions of stability and baseload generation capability. This shift in priorities is particularly evident in the context of nuclear power plants (NPPs), where adaptability over constant output is becoming more important. As our energy infrastructure and resources embraces the rise of distributed energy generation, the inherent variability in net demand continues to grow. Moreover, the use of nuclear energy as a source of heat for decarbonizing the industrial sector is becoming a very pressing topic. In such environment, advanced NPPs are poised to enter a more competitive energy market, delivering both, flexible electricity and heat. This shift motivates the exploration of TES systems, designed to empower NPPs with nimble responsiveness to market fluctuations, flexible heat delivery capabilities, and redefine their role in the energy field. TES systems offer the unique advantage of storing nuclear energy in its original form as heat, thereby affording unparalleled flexibility in its subsequent utilization.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Annual Performance of the Second-Generation Variable-Geometry Oscillating Surge Wave Energy Converter

Recent studies in wave energy have highlighted the need for a structured innovation approach in wave energy converter (WEC) design because cost-of-energy estimates have remained high. One specific innovation being investigated by the National Renewable Energy Laboratory is WEC geometry control, which uses control surfaces in combination with an oscillating surge WEC (OSWEC) to increase device availability and power generation while limiting structural costs. This study performs the first analysis of annual performance for a novel OSWEC with geometry control to understand how the geometry control affects availability, annual power generation, and structural loadings like the power-take-off (PTO) torque or surge foundation force. Device hydrodynamic coefficients are calculated using linear potential theory for six geometry configurations. A nonideal PTO system is assumed and quadratic viscous damping losses are considered. Annual performance is evaluated and compared for three U.S. wave energy sites. The WEC geometry and PTO system are controlled on a sea-state basis to optimize for power capture while remaining under limits set on motion amplitude and structural loads. Results indicate that geometry control can increase availability up to 25 days in an average year depending on design limits, increase average power generation, and significantly reduce peak structural loads.

30 DIRECT ENERGY CONVERSION↗

Managing Solar Photovoltaic Integration in the Western United States: Power System Flexibility Requirements and Supply

As penetrations of variable renewable energy generation technologies such as wind and solar photovoltaics (PV) continue to increase across the United States, greater uncertainty and variability in the net load often lead to a concern about how power systems may adapt. Managing the system net load (i.e., load minus contribution from variable generation technologies) may become more challenging with increasing variable generation, as the magnitude and frequency of net ramps increase. However, there is inherent flexibility in power systems through the conventional generator fleet (under least-cost unit commitment and economic dispatch), less-conventional generation sources (e.g., storage, demand response, concentrating solar power with thermal energy storage), and imports and exports with neighbors. In this analysis, we create an open-source tool to analyze the flexibility of the results of a specific commercial unit commitment and economic dispatch tool (PLEXOS), but the code can be applied generically as well. The tool assesses the flexibility requirements (or demand) of a system through a net load analysis. The constraints and limitations of each generator are then considered to determine the availability (or supply) of flexibility. Then, the supply and demand of flexibility are compared to gain a more complete picture of potential flexibility concerns. We apply this open-source tool to high-penetration PV scenarios constructed for three focus regions in the western United States defined using the Resource Planning Model (RPM) capacity expansion modeling tool: RPM-OR, RPM-CO, and RPM-AZ. Generally, we find few flexibility concerns, as the western United States represents a large and interconnected power system with significant inherent flexibility. In addition, the PV scenarios we analyzed are overbuilt on capacity, leaving plenty of ramping ability on the system. We do find that for each focus region, the impact of imports on meeting ramping needs is essential. This means the PV integration in each focus region impacts the entire rest of the system. Each system has different dominant sources of flexibility. The conventional generator fleet (especially coal and gas combined-cycle technologies) as well as less-conventional sources such as storage are all shown to be important sources of flexibility. The scenarios evaluated here were designed to study the planning and operations impact of high solar penetration in each of three focus regions. However, none of the three focus regions likely will deploy PV in isolation, meaning the ability of imports and exports to provide flexibility may be considerably different in scenarios with strong PV deployment in every region. Overall, we intend that the framework we present here will be useful in future analysis of other system evolutions to identify whether and how flexibility may constrain the successful deployment of variable generation technologies.

14 SOLAR ENERGY↗

Leak detection in a subcritical boiler

Thermal power plants experience cycling duty leading to the fatigue of the boiler and heat exchanger tubes. As a result, tube failures occur frequently in coal fired fleets leading to forced outages. Furthermore, because the tube leaks have been the major source of unwanted shutdowns and the number of outages is increasing, present work focuses on the detection and isolation of the leak in a subcritical boiler based upon the process data from a commercial coalfired power plant. The mass balance equation around the steam drum was analyzed using timeseries data collected from a 300 MW power plant. The ratio of the feed water mass flow rate to the steam mass flow rate was defined as a key parameter for detecting leaks. The difference in slope between the feedwater and steam mass flow rate during the normal and faulty operations was established as the upper control limit for real time monitoring. To reduce false alarm rates that arise when raw signal is directly compared against the threshold due to common process fluctuations, an optimal filter was derived for smoothing. It was found that the optimal filter reacted much more quickly to process changes than an exponential moving average filter, around 8 h earlier on average. Occurrence of relatively high false alarm rates even in the filtered responses was related to the cycling of the boiler from the base load condition. Variable threshold was established to keep false alarm rates to the minimum while maintaining the leak detection rate. Finally, the leak was located at the economizer and this could readily be isolated by investigating the magnitude of the mass flow rates ratio and the temperature at the economizer outlet.

42 ENGINEERING↗

AI-based design of a nuclear reactor core

The authors developed an artificial intelligence (AI)-based algorithm for the design and optimization of a nuclear reactor core based on a flexible geometry and demonstrated a 3× improvement in the selected performance metric: temperature peaking factor. The rapid development of advanced, and specifically, additive manufacturing (3-D printing) and its introduction into advanced nuclear core design through the Transformational Challenge Reactor program have presented the opportunity to explore the arbitrary geometry design of nuclear-heated structures. The primary challenge is that the arbitrary geometry design space is vast and requires the computational evaluation of many candidate designs, and the multiphysics simulation of nuclear systems is very time-intensive. Therefore, the authors developed a machine learning-based multiphysics emulator and evaluated thousands of candidate geometries on Summit, Oak Ridge National Laboratory’s leadership class supercomputer. The results presented in this work demonstrate temperature distribution smoothing in a nuclear reactor core through the manipulation of the geometry, which is traditionally achieved in light water reactors through variable assembly loading in the axial direction and fuel shuffling during refueling in the radial direction. The conclusions discuss the future implications for nuclear systems design with arbitrary geometry and the potential for AI-based autonomous design algorithms.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

A Novel Secondary Frequency Regulation with Optimal Priority Selection of AGC Contributions

Automatic generation control (AGC) is used to maintain acceptable frequencies during operation owing to fluctuations in load and variable resources. In conventional industry applications, the AGC signal is allocated to each generator according to the predispatched frequency regulation capacity or the order of economic efficiency. However, with the increasing integration of inverter-based resources (IBRs), the retirement of conventional synchronous generators (SGs) has posed new challenges to frequency control schemes because fewer of them are optional for AGC regulation. In this paper, we propose a novel model predictive control (MPC)-based frequency regulation model to reduce control cost and ensure stability, by considering different critical dynamic factors when optimally selecting the AGC units. The proposed control model – developed in a general form – comprehensively embeds characteristics such as generator ramping rates, reserve capacity, and operation cost. The model predictive control–based two-timescale AGC scheme enhances the capability of immunizing the power disturbance from types of resources by coordinating the control signals between faster IBRs and slower SGs. The case study’s proposed model is verified to be effective in synergistically enforcing different dynamic properties of AGC units into the frequency regulation scheme.

Jiang, Sufan [The University of North Carolina at ↗

Guide for Grid-Interactive Efficient Buildings for Federal Agencies

This guide provides an overview of GEB characteristics and benefits and how to analyze, identify, and implement GEB retrofit opportunities. It is important to understand the building’s systems as well as what utility program offerings are available at the site (e.g., time-of-use, electricity rates, demand charges, demand response programs, etc.). It is also important to understand the key goals for the site (e.g., environmental, cost savings, energy savings) and the current energy usage breakdown by equipment and load profile variability by day, month, and season.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Impacts of Regional Coordination on Transmission Needs for Power System Resource Adequacy [Slides]

Resource adequacy (RA) is an important component of bulk power system reliability that addresses whether there are sufficient resources available to meet electricity demand at all times. RA analysis is used to assess whether the planned power system will provide reliable electricity to consumers while accounting for equipment outages, weather variability, and load uncertainty. Coordination between regions can enable resource sharing to meet RA needs if sufficient transmission capacity exists. Transmission's role in RA coordination can be particularly pronounced for large power systems like the U.S. electricity grid which contains geographically diverse demand and weather-dependent resources. Depending on the level of coordination desired, existing inter-regional transmission capacity may not be sufficient. This study is designed to assess optimal pathways for the development of inter-regional transmission in the U.S. under varying levels of RA coordination. Results can inform long-term grid infrastructure planning and provide insights into potential benefits of greater coordination for generation and transmission planning between regional U.S. power systems.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Probabilistic Look-ahead Contingency Analysis Integration with Commercial Tool and Practical Data

This paper presents an initial effort of integrating a smart sampling-based probabilistic look-ahead contingency analysis algorithm with General Electric (GE) Grid Solutions’ commercial energy management system (EMS) tool as a proof-of-concept for a seamless research tool integration using real world large-scale grid data. With the increasing impact of random forces such as variable generation and load, their stochastic behaviors cannot be ignored. However, the current practices are still dominated by deterministic tools. They are becoming increasingly inadequate for the future grid. The developed look-ahead contingency analysis algorithm incorporates forecast errors of variable energy and load to address the challenges brought by the increasing uncertainty of power system. The algorithm can reveal the potential violations caused by the variance of variable energy and load that are not normally detected by traditional deterministic approaches. To test its performance under practical environments ( real data with real commercial tool), significant efforts have been made to prepare test cases, modify GE EMS tool, and adapt an extreme value distribution algorithm to analyze the GE EMS’s violation-only outputs. The test results clearly demonstrate the effectiveness of the developed algorithm as new transformer violations that were not previously detected have been identified. This performance provides better situational awareness to engineers for their decision-making process under uncertainty. Moreover, with the discussion of computational performance and future work, this paper has shown a clear path for integrating the probabilistic algorithm with commercial tools to make us better equipped for the changing power system.

Modeling and simulation of power systems, constrai↗