Gravity-improved metastability bounds for the Type-I seesaw mechanism

Right-handed neutrinos (RHN) destabilize the electroweak vacuum by increasing its decay rate. In the SM, the latter is dominated by physics at the RG scale at which λ reaches its minimum, ${\mu}_{\ast}^{\textrm{SM}}$ ~10 17 GeV. For large neutrino Yukawa coupling Y ν , RHNs can push μ* beyond the Planck scale, implying that gravitational effects need to be taken into account. In this work, we perform the first comprehensive study of electroweak vacuum metastability in the type-I seesaw mechanism including these effects. Our analysis covers both low- and high-scale seesaw models, with two as well as three RHNs and for multiple values of the Higgs’ non-minimal coupling to gravity. We find that gravitational effects can significantly stabilize the vacuum, leading to weaker metastability bounds. We show that metastability sets the strongest bounds for low-scale seesaws with M N > 1 TeV. For high-scale seesaws, we find upper bounds on the allowed masses for the RHNs, which are relevant for high-scale leptogenesis. We also point out that Tr(${Y}_{\nu}^{\dagger}$Y ν ), which is commonly used to express these metastability bounds, cannot be used for all of parameter space. Instead, we argue that bounds can always be expressed reliably through Tr(${Y}_{\nu}^{\dagger}$Y ν ${Y}_{\nu}^{\dagger}$Y ν ). Lastly, we use this insight to develop a new technique for an easier RG analysis applicable to scenarios with degenerate RHN masses.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Vacuum-deposited optical coatings experiment (A0138-4)

The stability of various vacuum deposited optical coatings exposed to the space environment were analyzed. A wide range of optical components manufactured by vacuum deposition, such as metallic and multidielectric reflective coatings in the UV range, metal dielectric interference filtes in the UV and IR ranges, narrow-bandpass filters int he near-UV and visible ranges, selective metallic mirrors in the range from 1500 to 2500 A. antireflective and reflective IR coatings, beam splitters in the visible and IR ranges, and optical surface reflection (OSR) coatings were developed. Many of these components were incorporated into scientific and technical experiments flown on balloons and rockets as well as on Symphonie, Meteosate, OTS, D2-B, TIROS n, and others. It appears that these components operate successfully in flight.

Malherbe, A.↗

Long-lived thermal control materials for high temperature and deep space applications

Considerable effort has been put into developing thermal-control materials for the Galileo space-craft. This paper presents a summary of these findings to date with emphasis on requirements, testing and results for the post-Challenger Galileo mission. Polyimide film (Kapton), due to its inherent stability in vacuum, UV, and radiation environments, combined with good mechanical properties over a large temperature range, has been the preferred substrate for spacecraft thermal control materials. Composite outer layers, using Kapton substrates, can be fabricated to meet the requirements of severe space environments. Included in the processing of Kapton-based composite outer layers can be the deposition of metal oxide, metallic and/or polymeric thin-film coatings to provide desirable electrical, optical and thermo-optical properties. In addition, reinforcement of Kapton substrates with fabrics and films is done to improve mechanical properties. Also these substrates can be filled with varying amounts of carbon to achieve particular electrical properties. The investigation and material development reported on here has led to improved thermo-gravimetric stability, surface conductivity, RF transparency, radiation and UV stability, flammability and handle-ability of outer layer thermal control materials for deep space and near-sun spacecraft. Designing, testing, and qualifying composite thermal-control film materials to meet the requirements of the Galileo spacecraft is the scope of this paper.

Whitt, Robin↗

Decaying scalar dark matter in the minimal left-right symmetric model

In the minimal left-right symmetric theory, the dark matter candidate is usually ascribed to the lightest right-handed neutrino. Here we present an alternative decaying dark matter candidate in this model in terms of the lightest neutral scalar from the 𝑆⁢𝑈⁢(2) 𝑅 -triplet field. This setup requires a vast hierarchy between the scalar mass and the left-right symmetry breaking scale, which renders the scalar dark matter sufficiently stable on cosmological time scales. The stability of the dark matter imposes constraints on the right-handed neutrino mass, which has consequences for the neutrino mass generation, as well as for leptogenesis. Although somewhat fine-tuned, it provides a very economical scenario wherein the minimal left-right model can simultaneously explain dark matter, neutrino masses, and the matter-antimatter asymmetry of the Universe.

baryogenesis↗

Phase Measurements of a 140-GHz Confocal Gyro-Amplifier

The phase stability of a 140-GHz, 1-kW pulsed gyro-amplifier system and the phase dependence on the cathode voltage were experimentally measured. To optimize the measurement precision, the amplifier was operated at 47 kV and 1 A, where the output power was ~ 30 W. The phase was determined to be stable both pulse-to-pulse and during each pulse, so far as the cathode voltage and electron beam current are constant. The phase variation with voltage was measured and found to be 130 ± 30° /kV, in excellent agreement with simulations. The electron gun used in this device is non-adiabatic, resulting in a steep slope of the beam pitch factor with respect to cathode voltage. This was discovered to be the dominant factor in the phase dependence on voltage. The use of an adiabatic electron gun is predicted to yield a significantly smaller phase sensitivity to voltage, and thus a more phase-stable performance. To our knowledge, these are the first phase measurements reported for a gyro-amplifier operating at a frequency above W-band.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Foam-insulated cryo-compressed hydrogen storage vessels for buses

Here, large reductions (40 % vs. compressed gaseous hydrogen vessels and 17 % vs. vacuum insulated cryo-compressed vessels) in hydrogen storage system cost are possible by operating buses with foam-insulated cryo-compressed hydrogen (CcH 2 ) vessels. Detailed thermodynamic analysis reveals that large size and rapid H 2 consumption in buses compensate for the poor performance of foam insulation (∼100 times more conductive than vacuum multilayer insulation), resulting in compact and inexpensive H 2 storage systems with sufficient H 2 capacity for the longest routes (500 km) while maintaining previously identified advantages of CcH 2 systems: increased autonomy, rapid high density refueling, and improved safety, while simultaneously avoiding vacuum insulation stability problems resulting from composite resin outgassing.

Cryo-compressed↗

Combined Stress Testing of Perovskite Solar Cells for Stable Operation in Space

Perovskite solar cells (PSCs) could provide new low-cost opportunities for powering spacecraft. Here we are designing a PSC resilient to lunar surface conditions, focusing on contact/barrier layers combinations that maximize stability. Thermal vacuum stress shows cells with gold back-contacts and SiOx protection retain >90% of initial efficiency and indium tin oxide (ITO)-contacted cells retain ~100% of initial efficiency after five months of stress. SiO x mitigates mechanical aspects of contact stress, retaining 99% of initial efficiency, whereas cells with silicone/cover glass decreased 27%. We further exposed cells to combined illumination, 75 °C heat, and 10 -6 Torr vacuum for 24 h and found that ITO-contacted cells outperformed Au-contacted cells.

14 SOLAR ENERGY↗

Mass generation in an Abelian gauge theory with multiple scalar fields and no tree-level dimensionful couplings

We study the Abelian Higgs model with multiple scalar fields, but without mass terms. Solving the model nonperturbatively order-by-order in the number of scalar fields, we find that radiative corrections generate masses for the scalar and gauge boson, without spontaneous symmetry breaking. The mass scales are set by the Λ -parameter of the electroweak running coupling, thereby naturally avoiding the hierarchy problem. No part of our calculation employs a weak-coupling expansion, and we find that the perturbative vacuum is metastable, and hence must decay to the stable nonperturbative vacuum of the theory, which we identify. Although the field content of our Lagrangian is standard, our results predict the existence of two heavy scalar resonances in addition to the Higgs. We believe that these predicted resonances will ultimately allow experimentalists to discriminate between our method and standard solutions of the Higgs model. Published by the American Physical Society 2024

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Applicability of semiclassical theories in the strong-field plasma regime

For many purposes, classical plasma dynamics models can work surprisingly well, even for strong electromagnetic fields, approaching the Schwinger critical fields, and high frequencies, approaching the Compton frequency. However, the applicability of classical models tends to depend rather sensitively on the details of the problem. In the present paper, we study the specific case of plasma oscillations to draw a line between the classical and quantum relativistic regimes. Here, due to the field geometry of study, mechanisms like radiation reaction and Breit-Wheeler pair production, which tend to be important for electromagnetic fields, are rather effectively suppressed. Moreover, we find that the polarization current due to the electron spin is generally negligible for frequencies below the Compton frequency, compared with the free current, whose magnitude is well-approximated by the classical Vlasov theory. However, we show that pair creation due to the Schwinger mechanism can sometimes be important for surprisingly modest field strengths, of the order of 10% of the critical field or even smaller. A rough guideline for when the classical Vlasov theory can be applied is given.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

In situ counter-diffusion crystallization and long-term crystal preservation in microfluidic fixed targets for serial crystallography

Compared with batch and vapor diffusion methods, counter diffusion can generate larger and higher-quality protein crystals yielding improved diffraction data and higher-resolution structures. Typically, counter-diffusion experiments are conducted in elongated chambers, such as glass capillaries, and the crystals are either directly measured in the capillary or extracted and mounted at the X-ray beamline. Despite the advantages of counter-diffusion protein crystallization, there are few fixed-target devices that utilize counter diffusion for crystallization. In this article, different designs of user-friendly counter-diffusion chambers are presented which can be used to grow large protein crystals in a 2D polymer microfluidic fixed-target chip. Methods for rapid chip fabrication using commercially available thin-film materials such as Mylar, propylene and Kapton are also detailed. Rules of thumb are provided to tune the nucleation and crystal growth to meet users' needs while minimizing sample consumption. These designs provide a reliable approach to forming large crystals and maintaining their hydration for weeks and even months. This allows ample time to grow, select and preserve the best crystal batches before X-ray beam time. Importantly, the fixed-target microfluidic chip has a low background scatter and can be directly used at beamlines without any crystal handling, enabling crystal quality to be preserved. The approach is demonstrated with serial diffraction of photoactive yellow protein, yielding 1.32 Å resolution at room temperature. Fabrication of this standard microfluidic chip with commercially available thin films greatly simplifies fabrication and provides enhanced stability under vacuum. These advances will further broaden microfluidic fixed-target utilization by crystallographers.

Liu, Zhongrui↗

Space stable thermal control coatings

The MOX method, i.e., the use of zinc and titanium oxalate precursors, has the distinct advantages of simple and rapid processing, and of controlled pigment particle size. The chemical identify of TiOX was determined. The Zn/Ti ratio effect on the reflectance spectra and ultraviolet irradiation stability in vacuum for Zn2TiO4 was examined. Optimized processing parameters are considered for reproducibly obtaining a pigment of the most desirable optical properties and behavior.

Harada, Y.↗

Design, fabrication, and test of a full-scale graphite/epoxy metering truss for the space telescope

This paper presents the work performed in a program sponsored by MSFC-NASA in which a full-scale graphite/epoxy metering truss was designed, fabricated and tested. The primary requirement was to provide a structure that was dimensionally stable in a transient temperature environment. Structural element characterization requiring measurements in the microstrain region are described along with resulting strength, stiffness and coefficient of thermal expansion data. The full-scale tests included static, dynamic and thermal-vacuum dimensional stability evaluations.

Oken, S.↗

Space radiation resistant transparent polymeric materials

A literature search in the field of ultraviolet and charged particle irradiation of polymers was utilized in an experimental program aimed at the development of radiation stable materials for space applications. The rationale utilized for material selection and the synthesis, characterization and testing performed on several selected materials is described. Among the materials tested for ultraviolet stability in vacuum were: polyethyleneoxide, polyvinylnaphthalene, and the amino resin synthesized by the condensation of o-hydroxybenzoguanamine with formaldehyde. Particularly interesting was the radiation behavior of poly(ethyleneoxide), irradiation did not cause degradation of optical properties but rather an improvement in transparency as indicated by a decrease in solar absorptance with increasing exposure time.

Giori, C.↗

Telescopes for a lunar outpost

This paper presents an overview of lunar-based telescopes. It begins with a review of the impressive attributes of the moon for astronomy which include a hard vacuum, seismic stability, low gravitational field, large surface area, dark and radio-quiet skies on the far-side, cold craters at the poles, and an abundance of raw materials. These attributes, coupled with the availability of technicians at a lunar outpost, make the moon the most attractive site for the next generation of space-based observatories. It is argued that modest, light-weight instruments such a generic 1-m optical/UV/IR telescope and a low radio frequency phased array are well suited for early deployment on the moon. More advanced concepts such as a 16-m filled aperture telescope and an optical interferometer will make unprecedented strides in sensitivity and resolution. Although complex, such telescopes are well-suited to an evolutionary construction and deployment scheme.

Burns, Jack O.↗