Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “vacuum electronics”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Advanced Diagnostics of Broad Spectrum Multipactor

Multipactor is a resonance event between electron emission and RF fields causing exponential secondary electron re-emission growth when the secondary electron yield of the primary electron impact energy exceeds unity. Multipactor is a serious problem in vacuum electron devices (VEDs) such as particle accelerators, radars, electronic warfare systems, directed energy devices, and even Hall effect thrusters. It also poses an even greater threat to space communication systems where high power, multi-channel links are required. The UC Davis and SLAC team will conduct basic research to advance the fundamental understanding of multipactor physics by developing and carrying out full spectrum, radio frequency (RF) laboratory tests aimed at understanding both single and two-surface multipactor phenomena and at evaluating novel multipactor mitigation approaches for accelerator, space-based RF systems, as well as high power microwave (HPM) applications.

36 MATERIALS SCIENCE↗

Machine Learning for Multipactor Susceptibility Prediction in Planar RF Gaps

Multipactor discharge is a nonlinear electron avalanche that limits the performance of high-power radio-frequency (RF) and vacuum electronic devices. Predicting multipactor susceptibility traditionally relies on Monte Carlo or particle-in-cell (PIC) simulations, which become computationally expensive for large parametric studies. In this work, we present a supervised machine-learning (ML) framework for prediction of multipactor susceptibility in a two-surface planar geometry. The models are trained using high-fidelity PIC simulation generated susceptibility data and learn the relationship between operational parameters, geometry, and material-dependent secondary electron emission properties. The proposed approach enables rapid reconstruction of susceptibility charts while preserving the physical structure of multipactor growth regions.

43 PARTICLE ACCELERATORS↗

Transitions between electron emission and gas breakdown mechanisms across length and pressure scales

This Perspective outlines theoretical, simulation, and experimental studies linking electron emission and gas breakdown. Many studies have investigated field emission-driven microscale gas breakdown, including recent reviews [Garner et al., IEEE Trans. Plasma Sci. 48, 808–824 (2020); Fu et al., Plasma Res. Express 2, 013001 (2020)]. This Perspective focuses on generalizing field emission-driven microscale gas breakdown to consider the contribution of other forms of electron emission, specifically thermionic and space-charge limited. Recent theoretical studies have unified thermionic, field, and space-charge limited emission with and without collisions to derive “nexuses” where the individual solutions match, indicating transitions in the mechanisms. Reducing device size to nanoscale at atmospheric pressure leads to a transition from field emission to space-charge limited emission for nitrogen at ~250 nm. This Perspective summarizes the derivation of these nexuses and future extensions. We next describe simulation and theoretical studies for field emission-driven microscale gas breakdown and highlight how the nexus theory may be integrated to account for temperature, space-charge, and pulse parameters. Finally, we summarize the development of optical techniques to assess microscale gas breakdown and recent nanoscale experiments at atmospheric pressure that suggest that space-charge may begin to contribute to field emission prior to gas breakdown. We highlight the combination of theory, simulation, and experiment to link electron emission and gas breakdown mechanisms across length, pressure, and temperature scales for applications that include vacuum electronics, pulsed power, and medicine.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Machine Learning for Mapping Multipactor Susceptibility in RF Systems: Capabilities and Generalization Constraints

Multipactor is a surface-driven electron avalanche phenomenon that degrades the performance and reliability of radio-frequency (RF) systems in particle accelerator and vacuum electronics applications. Multipactor behavior in a given device structure is conventionally assessed through susceptibility charts, which provide a parameter-space characterization of the instability. In this work, we assess the capabilities of machine-learning (ML) models to learn and predict such susceptibility charts and analyze the constraints governing their generalization across materials. Using a simulation-derived dataset spanning six distinct secondary-electron-yield material profiles in a canonical two-surface planar geometry, we train supervised regression models and artificial neural networks to predict the time-averaged electron growth rate, δavg, across the relevant parameter space. Model performance is evaluated using metrics that explicitly probe the structure of susceptibility charts, including Intersection over Union, Structural Similarity Index, and correlation analysis. Tree-based ensemble models outperform neural-network models in reconstructing susceptibility regions and in generalizing across material domains. Principal-component analysis reveals disjoint material feature distributions, indicating that the piecewise mode structure of multipactor susceptibility is difficult to represent with a single global model and that generalization is constrained by data coverage rather than by model complexity. An exhaustive reduced-coverage study further shows that sparse material-space coverage can yield mean performance in the same general range but producing large variability in the susceptibility-region overlap. These results clarify the capabilities of ML-based surrogate models for parameter-space characterization of multipactor discharge. They also provide guidance for their appropriate use in RF system design.

43 PARTICLE ACCELERATORS↗

Technology for Television

A project being conducted by Varian Associates, Inc. and Lewis Research Center would allow a Ultrahigh Frequency (UHF) TV station to save 50% of its electricity cost. Because UHF stations need substantially more transmitter power, an amplifying device was needed. In the early 1970's Dr. Henry Kosmahl of Lewis had developed a radiowave amplifier to improve satellite transmission. He later worked with modifying klystron transmitters, electronic vacuum tubes used to generate and amplify UHF frequencies. If Dr. Kosmahl's multistage depressed collector or MDC can be incorporated into the klystron, the magnetic field shapes of electron beams can be changed to aid the energy recovery function of the MDC.

Source record↗

Atomic step disorder on polycrystalline surfaces leads to spatially inhomogeneous work functions

Structural disorder causes materials’ surface electronic properties, e.g., work function (ϕ), to vary spatially, yet it is challenging to prove exact causal relationships to underlying ensemble disorder, e.g., roughness or granularity. For polycrystalline Pt, nanoscale resolution photoemission threshold mapping reveals a spatially varying ϕ=5.70±0.03 eV over a distribution of (111) vicinal grain surfaces prepared by sputter deposition and annealing. With regard to field emission and related phenomena, e.g., vacuum arc initiation, a salient feature of the ϕ distribution is that it is skewed with a long tail to values down to 5.4 eV, i.e., far below the mean, which is exponentially impactful to field emission via the Fowler–Nordheim relation. We show that the ϕ spatial variation and distribution can be explained by ensemble variations of granular tilts and surface slopes via a Smoluchowski smoothing model wherein local ϕ variations result from spatially varying densities of electric dipole moments, intrinsic to atomic steps, that locally modify ϕ. Atomic step-terrace structure is confirmed with scanning tunneling microscopy (STM) at several locations on our surfaces, and prior works showed STM evidence for atomic step dipoles at various metal surfaces. From our model, we find an atomic step edge dipole μ=0.12 D/edge atom, which is comparable to values reported in studies that utilized other methods and materials. Our results elucidate a connection between macroscopic ϕ and the nanostructure that may contribute to the spread of reported ϕ for Pt and other surfaces and may be useful toward more complete descriptions of polycrystalline metals in the models of field emission and other related vacuum electronics phenomena, e.g., arc initiation.

36 MATERIALS SCIENCE↗

Power-Efficient, High-Current-Density, Long-Life Thermionic Cathode Developed for Microwave Amplifier Applications

A power-efficient, miniature, easily manufactured, reservoir-type barium-dispenser thermionic cathode has been developed that offers the significant advantages of simultaneous high electron-emission current density (>2 A/sq cm) and very long life (>100,000 hr of continuous operation) when compared with the commonly used impregnated-type barium-dispenser cathodes. Important applications of this cathode are a wide variety of microwave and millimeter-wave vacuum electronic devices, where high output power and reliability (long life) are essential. We also expect it to enable the practical development of higher purveyance electron guns for lower voltage and more reliable device operation. The low cathode heater power and reduced size and mass are expected to be particularly beneficial in traveling-wave-tube amplifiers (TWTA's) for space communications, where future NASA mission requirements include smaller onboard spacecraft systems, higher data transmission rates (high frequency and output power) and greater electrical efficiency.

Wintucky, Edwin G.↗

Effect of electron irradiation in vacuum on FEP-A silicon solar cell covers

Fluorinated ethylene-propylene-A (FEP-A) covers on silicon solar cells were irradiated with 1-MeV electrons, in vacuum, to an accumulated fluence equivalent to approximately 28 years in synchronous orbit. The effect of irradiation on the light transmittance of FEP-A was checked by measuring the short-circuit current of the cells after each dose increment. The results indicate no apparent overall loss in transmission due to irradiation of FEP-A. Filter wheel measurements revealed some darkening of the FEP-A at the blue end of the spectrum. Although no delamination from the cell surface was observed while in vacuum, embrittlement of FEP-A occurred at the accumulated dose.

Marsik, S. J.↗

Development of High-QE GaN Photodectors for Liquid Noble Particle Detectors

Detection of the handful of photons generated when a dark matter particle interacts in a liquid Xenon detector requires a new type of photodetector with very high detection efficiency at ultraviolet wavelengths, very low radioactive backgrounds, and essentially no measureable readout noise (achieved with devices with high intrisic gain). Such devices would find wide applicability to not only high energy physics experiments, but to a number of commercial applications including, e.g., biomedical imaging of fluorescent tags. We developed photodetectors based on amorphous GaN thin film structures (photocathodes) grown by molecular beam epitaxy on quartz windows. We also developed approaches to integrate these photocathode device structures with vacuum electron multipliers. All materials and fabrication techniques were developed to minimize radioactive backgrounds in materials, so these detectors could be used for very low count rate experiments, such as the future liquid-Xenon dark matter detectors, and future liquid-Argon neutrino detectors. We demonstrated growth of very high quantum efficiency amorphous GaN cathodes grown on a number of different substrates (Stainless steel, p-Silicon) reaching detection efficiencies of 80% at 220nm. The key to this growth was to use nitrogen plasma-assistend MBEs and very low growth temperatures. We also discovered that thinner structures (e.g.,40nm a-GaN thin films) had the best performance. We successfully demonstrated techniques for the vacuum transfer of these photocathode structures to a novel chamber that used hydraulics and bellow to form a cold indium bond needed to integrate these cathodes into sealed-tube devices. A complete, stand-along, device could not be completed during this proposal period due to difficulties in growing structures on the thick quartz window. Subsequent work is aimed at addressing this difficulty, by growing a buffer layer on the quartz substrate.

07 ISOTOPE AND RADIATION SOURCES↗

Gaia: segmented germanium detector for high-energy X-ray fluorescence and spectroscopic imaging

We present Gaia, a monolithic array of 96 high-purity germanium pixel detectors integrated with a custom low-noise application-specific integrated circuit (ASIC) and a field-programmable gate array (FPGA)-based data acquisition system. The sensor operates at ∼100 K using a commercial closed-cycle cryocooler, with the in-vacuum electronics thermally isolated from the cold finger to ensure thermal stability. The system demonstrates an average energy resolution of 711 eV at 122 keV, measured using a 57 Co source, and 253 eV at 5.89 keV, measured with 55 Fe across all channels. The readout architecture incorporates a high-performance FPGA paired with a dual-core ARM processor, forming a complete embedded Linux-based computing platform. Communication between the processor and FPGA is handled via memory-mapped I/O, and data are streamed over high-speed gigabit Ethernet. A full-scale 384-pixel Gaia detector, based on this 96-element module, is currently under fabrication.

36 MATERIALS SCIENCE↗

Advanced modeling of field enhanced thermionic emission

Shaped emitters are of interest to a broad range of applications in vacuum electronic devices. In particular, thermionic energy converters (TECs) take advantage of shaped emitters to increase the local surface field, thereby extracting more current for a given cathode temperature and applied voltage. However, modeling these devices is challenging; Warp [J.-L. Vay, D. P. Grote, R. H. Cohen, and A. Friedman, Comput. Sci. Discov. 5, 014019 (2012)] is a fully 3D particle-in-cell code capable of handling a wide range of physics problems and is well suited to modeling TECs. Additionally, recent improvements to Warp have enabled the accurate modeling of emitters with arbitrary curved surfaces. Specifically, the inclusion of subgrid resolution for computing the electrostatic potential and the ability to apply mesh refinement for specific areas of interest allow for a more accurate solution to the fields on these surfaces. These improvements coupled with Warp’s ability to handle variable particle weights make it an ideal candidate for simulating these complex devices. In this paper, the authors study the applicability of different subgrid configurations for simulating shaped emission surfaces and field convergence for different mesh-refinement techniques. They then implement a custom weighting algorithm that allows for uniform sampling of emission surfaces with a large variation in the surface electric field. They then use this algorithm to study emission for curved emitters in both the field-enhancement regime and the space-charge regime.

Edelen, Jonathan P. (ORCID:0000000215180652)↗

Miscibility Gap Systems

Immiscible droplets embedded in a host fluid in which a temperature gradient exists migrate toward the hot end of the host fluid because of the temperature dependence of the interfacial energy of the droplet. This thermocapillary migration effect was exploited in the design of a controllable heat valve which is the thermal analog of the electronic vacuum triode. Studies have also been made of test cells that could use thermocapillary migration to facilitate the study of condensation and dissolution kinetics in miscibility-gap solutions.

Schmid, L. A.↗

Micromachined TWTs for THz Radiation Sources

The Terahertz (THz) region of the electromagnetic spectrum (about 300 - 3000 GHz in frequency or about 0.1 - 1 mm free space wavelength) has enormous potential for high-data-rate communications, spectroscopy, astronomy, space research, medicine, biology, surveillance, remote sensing, industrial process control, etc. It has been characterized as the most scientifically rich, yet under-utilized, region of the electromagnetic spectrum. The most critical roadblock to full exploitation of the THz band is lack of coherent radiation sources that are powerful (0.001 - 1.0 W continuous wave), efficient (> 1%), frequency agile (instantaneously tunable over 1% bandwidths or more), reliable, and comparatively inexpensive. To develop vacuum electron device (VED) radiation sources satisfying these requirements, fabrication and packaging approaches must be heavily considered to minimize costs, in addition to the basic interaction physics and circuit design. To minimize size of the prime power supply, beam voltage must be minimized, preferably 10 kV. Solid state sources satisfy the low voltage requirement, but are many orders of magnitude below power, efficiency, and bandwidth requirements. On the other hand, typical fast-wave VED sources in this regime (e.g., gyrotrons, FELs) tend to be large, expensive, high voltage and very high power devices unsuitable for most of the applications cited above. VEDs based on grating or inter-digital (ID) circuits have been researched and developed. However, achieving forward-wave amplifier operation with instantaneous fractional bandwidths > 1% is problematic for these devices with low-energy (< 15 kV) electron beams. Moreover, the interaction impedance is quite low unless the beam-circuit spacing is kept particularly narrow, often leading to significant beam interception. One solution to satisfy the THz source requirements mentioned above is to develop micromachined VEDs, or "micro-VEDs". Among other benefits, micro-machining technologies provide superior high frequency wall conductivity as a result of superior surface smoothness compared with conventional mechanical or electric discharge machining approaches. Micro-VED technologies are already being applied to the development of millimeter-wave klystrons at Stanford Linear Accelerator Center and submillimeter-wave klystrons at the University of Leeds. We are investigating the use of micro-machining technologies to develop THz regime TWTs, with emphasis on folded-waveguide TWTs. The folded-waveguide TWT (FW-TWT) has several features that make it attractive for THz-regime micro-VED applications. It is a relatively simple circuit to design and fabricate, it is amenable to precision pattern replication by micro-machining, and it is has been demonstrated capable of forward-wave amplification with appreciable bandwidth. We are conducting experimental and computational studies of micro-VED FW-TWTs to examine their feasibility for applications at frequencies from 200 - 1000 GHz.

Booske, John H.↗

A Low Cost Traveling Wave Tube for Wireless Communications

Demand for high data rate wireless communications is pushing up amplifier power, bandwidth and frequency requirements. Some systems are using vacuum electron devices again because solid-state power amplifiers are not able to efficiently meet the new requirements. The traveling wave tube is the VED of choice because of its excellent broadband capability as well as high power efficiency and frequency. But TWTs are very expensive on a per watt basis below about 200 watts of output power. We propose a new traveling wave tube that utilizes cathode ray tube construction technology and electrostatic focusing. We believe the tube can be built in quantity for under $1,000 each. We discuss several traveling wave tube slow wave circuits that lend themselves to the new construction. We will present modeling results and data on prototype devices.

Vancil, Bernard Kenneth↗

Test and Analysis Capabilities of the Space Environment Effects Team at Marshall Space Flight Center

Marshall Space Flight Center has developed world-class space environmental effects testing facilities to simulate the space environment. The combined environmental effects test system exposes temperature-controlled samples to simultaneous protons, high- and low-energy electrons, vacuum ultraviolet (VUV) radiation, and near-ultraviolet (NUV) radiation. Separate chambers for studying the effects of NUV and VUV at elevated temperatures are also available. The Atomic Oxygen Beam Facility exposes samples to atomic oxygen of 5 eV energy to simulate low-Earth orbit (LEO). The LEO space plasma simulators are used to study current collection to biased spacecraft surfaces, arcing from insulators and electrical conductivity of materials. Plasma propulsion techniques are analyzed using the Marshall magnetic mirror system. The micro light gas gun simulates micrometeoroid and space debris impacts. Candidate materials and hardware for spacecraft can be evaluated for durability in the space environment with a variety of analytical techniques. Mass, solar absorptance, infrared emittance, transmission, reflectance, bidirectional reflectance distribution function, and surface morphology characterization can be performed. The data from the space environmental effects testing facilities, combined with analytical results from flight experiments, enable the Environmental Effects Group to determine optimum materials for use on spacecraft.

Finckenor, M. M.↗