Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “utility rates”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Metabolic cost of extravehicular activities

The data on metabolic rates during Skylab extravehicular activities are presented and compared with prior experience during Gemini and Apollo. Difficulties experienced with Gemini extravehicular activities are reviewed. The effect of a pressure suit on metabolic rate is discussed and the life support equipment capabilities of each life support system are reviewed. The methods used to measure metabolic rate, utilizing bioinstrumentation and operational data on the life support system, are described. Metabolic rates are correlated with different activities. Metabolic rates in Skylab were found to be within the capacities of the life support systems and to be similar to the metabolic rates experienced during Apollo lunar 1/6-g extravehicular activities. They were found to range from 100 kcal/h to 500 kcal/h, during both 1/6-g and zero-g extravehicular activities. The average metabolic rates measured during long extravehicular activities were remarkably consistent and appeared to be a function of crew pacing of activity rather than to the effort involved in individual tasks.

Waligora, J. M.↗

Application of thermal energy storage with electrified heating and cooling in a cold climate

Ground source heat pumps (GSHPs) have been shown to be an effective means of decarbonizing building heating and cooling, but the operation of these systems at scale presents challenges to sites and the grid due to increases in peak demand. Here, in this study, we investigate how the use of Thermal Energy Storage (TES), in the form of stratified water storage, could reduce the peak daily demand associated with GSHP systems and thus improve their cost effectiveness. This system was compared to a Combined Heat and Power (CHP) plant, to investigate the potential cost and emissions impacts of electrification on large energy users transitioning from high efficiency fossil fuel equipment. This study builds on previous research by using a significant campus area, and investigating the various impacts of an electrified system versus a state of the art fossil fuel system. An established method of TRNSYS modeling is used for the heat pumps and borehole heat exchangers (BHEs), along with the TES. The GSHP system with TES is modeled to follow industry standards and sized to provide an optimal balance of capital and operating costs. Costs were investigated for a unique large energy user rate structure, as well as for a more common generalized rate structure. The results show that the addition of TES to the GSHP system could reduce operating costs by 4.5%, but still incurs a 5.64% cost increase from the baseline CHP system. It is also shown, however, that a tactical integration of heat pumps into the CHP system is the most cost effective solution, only increasing the operating costs by 4.71%. Likewise, the impacts of different rate structures are highlighted, with the TES only resulting in 0.75% cost savings under the generalized utility rate. Furthermore, it is shown that thermal storage has great potential for demand reduction, with the addition of storage incurring a decrease of 7–22% in annual peak demand kW, dependent on the rate structure.

25 ENERGY STORAGE↗

Large-scale simulation-based parametric analysis of an optimal precooling strategy for demand flexibility in a commercial office building

Achieving success with grid-interactive efficient buildings (GEBs) is closely tied to the utilization of flexible loads. A valuable strategy involves the implementation of precooling techniques before high-demand events, such as peak hours, by adjusting zone air temperature setpoints. This leads to a reduction in thermal loads and peak electricity demand during these times, as the building’s thermal mass stores and subsequently releases thermal energy. However, the effectiveness of the pre-cooling optimization is highly contingent on specific conditions such as building thermal properties, weather conditions, utility rate structure, HVAC equipment sizing, etc. Therefore, investigating the impacts of these condition-specific factors is crucial, especially when considering precooling strategies that utilize thermal mass in commercial buildings. In this paper, we first devised a novel heuristic control approach that incorporates parameterized optimal precooling thermostat schedules to enhance demand flexibility in a commercial office building. Subsequently, we conducted a thorough performance evaluation of this control strategy. Here, the optimal thermostat schedule was parameterized using three optimization variables: the precooling start time, the precooling end time, and the precooling temperature setpoint. Utilizing the DOE medium-sized office building as the virtual testbed, we showed that the parameterized schedule effectively approximates model predictive control and requires drastically reduced computational overhead. In addition, we investigated the impact of different influencing factors on the optimal precooling strategy. These factors include building thermal mass, outdoor air conditions, and energy price profiles. Using high-performance computing, we simulated a total of 225 scenarios, consisting of three levels of thermal mass, five typical outdoor air temperature profiles, and fifteen time-of-use price plans. The results demonstrate that optimal thermostat scheduling could save substantial energy cost in medium-sized office buildings with heavy thermal mass but with some energy penalty. Although the potential for cost savings is lower in buildings with low and medium thermal mass, the energy penalty remains consistent in all three thermal mass scenarios. The study also highlights the need to account for zone diversity and recognize that a one-size-fits-all-zone setpoint schedule may not be suitable for all zones and can lead to unnecessary energy wastage. Furthermore, the results highlight that while outdoor air conditions play a role in cost and energy performance, the cooling load exerts a more immediate and substantial influence on cost savings in precooling strategies. Although cost savings are comparable under certain conditions with the same cooling load, observed deviations in energy penalty indicate potential disparities in the efficiency of the HVAC system during the load-shifting process. In addition, the duration of peak pricing and the ratio between peak and off-peak times exhibit clear correlations with cost savings and energy consumption, aligning with intuitive expectations. These findings offer valuable insights for optimizing precooling strategies in office buildings.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Revenue-Maximizing Shared Parking and Electric Vehicle Charging Management in Multi-Unit Dwellings

In urban areas, searching for parking and electric vehicle (EV) charging can result in cruising, congestion, and environmental externalities. Recognizing the business opportunity of offering private parking and charging infrastructure access within multi-unit dwellings (MUDs) during daytime, we model a shared parking and EV charging management system. We maximize the revenue of MUD charging hubs in mixed land use, catering to public demand. Our approach accounts for the objectives of the two stakeholders involved: a demand model is fitted on the choices of EV charging users, and the supply model optimizes the allocation of parking and charging requests in an MUD parking lot. A binary integer linear programming model for the allocation of parking and charging spaces with a rolling horizon is integrated with matching rules that handle both parking and charging requests. In our numerical experiments in a neighborhood of Chicago, Illinois, we estimate the performance of the MUD parking and charging system with metrics that include revenue, number of matchings, and utilization rates. At any given time, MUDs with lower prices attract more charging requests, particularly those of longer duration, resulting in higher revenue and greater charging utilization. Dynamic pricing facilitates a more equitable distribution of requests; as MUD parking lots reach capacity and their fees increase, other MUDs become more competitive, attracting additional requests. Comparing our method against first-come-first-served and optimal-solution benchmarks, we demonstrate our model’s effectiveness in dynamically managing mixed parking and charging demand in MUD charging hubs.

electric vehicle, multi-unit dwelling, charging in↗

Team Formation in Partially Observable Multi-Agent Systems

Sets of multi-agent teams often need to maximize a global utility rating the performance of the entire system where a team cannot fully observe other teams agents. Such limited observability hinders team-members trying to pursue their team utilities to take actions that also help maximize the global utility. In this article, we show how team utilities can be used in partially observable systems. Furthermore, we show how team sizes can be manipulated to provide the best compromise between having easy to learn team utilities and having them aligned with the global utility, The results show that optimally sized teams in a partially observable environments outperform one team in a fully observable environment, by up to 30%.

Agogino, Adrian K.↗

Energetics and the resistive tearing mode - Effects of Joule heating and radiation

The contribution of energy flux to the dynamics of magnetic field reconnection is analytically studied in order to determine the influence of Joule heating and radiation on the linear development of the tearing instability in slab geometry. A temperature-dependent Coulomb-like resistivity is used to provide the coupling between the dynamics and the energy equation. Analytical expressions are derived for the growth rates utilizing constant-psi and long-wavelength approximations. The solutions indicate the occurrence of several modes in addition to the usual tearing mode, several of which have relatively slow, complex growth rates. At large values of the magnetic Reynolds number, there are at least two modes with purely exponential growth when the radiative loss decreases with increasing temperature. If the radiation is neglected, the Joule heating alone also results in two modes with real, positive growth at large S. Below a particular value of S, all the modes are generally stabilized.

Steinolfson, R. S.↗

Techno-Economic Analysis for the Addition of a Thermal Energy Storage System to a Central Plant

Increasing energy demand and rising peak loads present significant challenges for energy management in commercial and institutional settings. As climate change drives greater cooling needs, central plants must navigate the complex tradeoffs between operational efficiency, cost control, and grid stability. Thermal energy storage (TES) systems offer a viable solution by shifting energy consumption from peak to off-peak periods, thereby reducing peak demand, lowering utility expenses, and improving grid resilience. However, the success of TES implementation hinges on appropriate system sizing, effective control strategies, and alignment with local utility rate structures. This article presents a techno-economic analysis of integrating a chilled water TES system into the central plant at California State University, Dominguez Hills. Drawing on historical load profiles and utility tariffs, we assess three TES sizing approaches and their corresponding control strategies from both energy and economic perspectives. This article utilizes a model-based approach to assess the impact of TES sizing and control strategies on the techno-economic feasibility of integrating TES into an existing central plant. The models employed for this analysis were calibrated using 4 years of historical data. Here, the results demonstrated that utility tariffs and the campus's operational profiles dictate the most feasible sizing and control methods. The findings offer valuable insights for institutions and commercial building managers exploring sustainable energy solutions. By demonstrating how optimized TES strategies can improve operational efficiency while achieving financial savings, this study highlights the potential for TES to align performance with cost effectiveness in real-world applications.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Probabilistic and maximum entropy modeling of chemical reaction systems: Characteristics and comparisons to mass action kinetic models

We demonstrate and characterize a first-principles approach to modeling the mass action dynamics of metabolism. Starting from a basic definition of entropy expressed as a multinomial probability density using Boltzmann probabilities with standard chemical potentials, we derive and compare the free energy dissipation and the entropy production rates. We express the relation between entropy production and the chemical master equation for modeling metabolism, which unifies chemical kinetics and chemical thermodynamics. Because prediction uncertainty with respect to parameter variability is frequently a concern with mass action models utilizing rate constants, we compare and contrast the maximum entropy model, which has its own set of rate parameters, to a population of standard mass action models in which the rate constants are randomly chosen. We show that a maximum entropy model is characterized by a high probability of free energy dissipation rate and likewise entropy production rate, relative to other models. We then characterize the variability of the maximum entropy model predictions with respect to uncertainties in parameters (standard free energies of formation) and with respect to ionic strengths typically found in a cell.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Analysis of Second Target Station Target Removal Dose Rates

The Second Target Station (STS) project at Oak Ridge National Laboratory’s spallation neutron source is a crucial initiative for maintaining U.S. leadership in neutron sciences. The STS aims to create the world’s brightest pulsed cold neutron source, enabling cutting-edge research across various scientific disciplines. To ensure safe and efficient maintenance operations, understanding the effects of shutdown dose rates from activated components within the STS target systems is essential. This study establishes a computational framework for calculating decay gamma sources and subsequent shutdown dose rates utilizing advanced methods to account for all activation channels, including high-energy interactions down to thermal neutron capture. This study describes a novel integration of multiple tools and provides an effective means of analyzing activation and shutdown dose rates at spallation neutron facilities. A custom-developed script automates the decay gamma source generation process, ensuring proper sampling during the variance reduction phase, which is critical for accurate predictions of shutdown dose rates.

Transmutation↗

Increasing the Number of Installed Residential Heat Pump Water Heaters in the USA Through Improved Technology and Utility Programs

Heat pump water heaters (HPWHs) offer an efficient alternative to electric resistance water heaters, but they suffer from limited market penetration. This paper reviews the current state of HPWHs in the USA, focusing on technology developments and programs to increase adoption. What technological improvements are needed to make HPWHs a good fit in more homes? Additionally, what are the best ways of promoting HPWHs to consumers? Improved communication and controls will allow HPWHs to provide demand response and follow dynamic utility rates. To enable fuel-switching, HPWHs are being developed that only need a standard 120V outlet. Split HPWHs can alleviate the cooling and noise that limit the use of HPWHs in small homes, multifamily buildings, and cold climates. Additionally, new utility programs aim to train installers and provide incentives to distributors to increase the number of HPWHs installed. Some utilities offer novel incentive programs that have led to increased customer uptake. Those advances, coupled with improved controls for load shifting and new products such as split HPWHs and HPWHs that can run on 120V power, may finally move the market forward.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Radiative heating rates during AAOE and AASE

Radiative transit computations of heating rates utilizing data from the 1987 Airborne Antarctic Ozone Experiment (AAOE) (Tuck et al., 1989) and the 1989 Airborne Arctic Stratospheric Experiment (AASE) (Turco et al., 1990) are described. Observed temperature and ozone profiles and a radiative transfer model are used to compute the heating rates for the Southern Hemisphere during AAOE and the Northern Hemisphere during AASE. The AASE average cooling rates computed inside the vortex are in good agreement with the diabatic cooling rates estimated from the ER-2 profile data for N2O for the AASE period (Schoeberl et al., 1989).

Rosenfield, Joan E.↗

RWPV bioreactor mass transport: earth-based and in microgravity

Mass transport and mixing of perfused scalar quantities in the NASA Rotating Wall Perfused Vessel bioreactor are studied using numerical models of the flow field and scalar concentration field. Operating conditions typical of both microgravity and ground-based cell cultures are studied to determine the expected vessel performance for both flight and ground-based control experiments. Results are presented for the transport of oxygen with cell densities and consumption rates typical of colon cancer cells cultured in the RWPV. The transport and mixing characteristics are first investigated with a step change in the perfusion inlet concentration by computing the time histories of the time to exceed 10% inlet concentration. The effects of a uniform cell utilization rate are then investigated with time histories of the outlet concentration, volume average concentration, and volume fraction starved. It is found that the operating conditions used in microgravity produce results that are quite different then those for ground-based conditions. Mixing times for microgravity conditions are significantly shorter than those for ground-based operation. Increasing the differential rotation rates (microgravity) increases the mixing and transport, while increasing the mean rotation rate (ground-based) suppresses both. Increasing perfusion rates enhances mass transport for both microgravity and ground-based cases, however, for the present range of operating conditions, above 5-10 cc/min there are diminishing returns as much of the inlet fluid is transported directly to the perfusion exit. The results show that exit concentration is not a good indicator of the concentration distributions in the vessel. In microgravity conditions, the NASA RWPV bioreactor with the viscous pump has been shown to provide an environment that is well mixed. Even when operated near the theoretical minimum perfusion rates, only a small fraction of the volume provides less than the required oxygen levels. 2002 Wiley Periodicals, Inc.

Models, Biological↗

Unveiling a classical mutant in the context of the GH 3 β-glucosidase family in Neurospora crassa

Classical fungal mutant strains obtained by mutagenesis have helped to elucidate fundamental metabolic pathways in the past. In the filamentous fungus Neurospora crassa, the gluc-1 strain was isolated long ago and characterized by its low level of β-glucosidase activity, which is essential for the degradation of cellulose, the most abundant biopolymer on Earth and the main polymeric component of the plant cell wall. Based on genomic resequencing, we hypothesized that the causative mutation resides in the β-glucosidase gene gh3-3 (bgl6, NCU08755). In this work, growth patterns, enzymatic activities and sugar utilization rates were analyzed in several mutant and overexpression strains related to gluc-1 and gh3-3. In addition, different mutants affected in the degradation and transport of cellobiose were analyzed. While overexpression of gh3-3 led to the recovery of β-glucosidase activity in the gluc-1 mutant, as well as normal utilization of cellobiose, the full gene deletion strain Δgh3-3 was found to behave differently than gluc-1 with lower secreted β-glucosidase activity, indicating a dominant role of the amino acid substitution in the point mutated gh3-3 gene of gluc-1. Our results furthermore confirm that GH3-3 is the major extracellular β-glucosidase in N. crassa and demonstrate that the two cellodextrin transporters CDT-1 and CDT-2 are essential for growth on cellobiose when the three main N. crassa β-glucosidases are absent. Overall, these findings provide valuable insight into the mechanisms of cellulose utilization in filamentous fungi, being an essential step in the efficient production of biorefinable sugars from agricultural and forestry plant biomass.

60 APPLIED LIFE SCIENCES↗

Charging Hub Scenario Sheet Screenshot

The Excel-based CHECT tool estimates the LCOC ($/kWh) by charger type (Level 1, Level 2, and DC fast charging) for a given charging hub scenario. CHECT requires users to input certain charging hub scenario parameters, including the number of chargers, daily utilization, and charger replacement frequency by charger type. Additional inputs such as the charging schedule, local utility rates, capital/operational costs, and financial inputs can be customized by the user, or the tool can generate results using appropriate default values from literature for the charging hub scenario and service location(s). Using the above inputs, CHECT performs a robust techno-economic analysis to generate the LCOC by charger type, broken down by cost category (e.g., capital, operational, utility, taxes) for various combinations of charging hub types (multiunit dwelling or public) and ownership models (residential, utility, or private company). It also outputs the annual discounted cash flows and determines the most sensitive input variables. In addition, the tool allows users to easily compare the LCOC across various ownership models or across different states.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Rooftop Solar in Lawrence, MA: Community Perspectives, Deceptive Practices, and Financing Options

This report was prepared as part of the U.S. Department of Energy's Communities Local Energy Action Program (Communities LEAP) pilot competitive technical assistance for the Lawrence Massachusetts Stakeholder Coalition (LSC) composed of The City of Lawrence, All In Energy, MassDevelopment, Mill City Community Investments, BlocPower and Groundwork Lawrence, and led by Browning the Green Space. The LSC identified rooftop solar photovoltaics as a top priority for this technical assistance opportunity. Lawrence faces high energy burden and electricity prices, thus rooftop solar can be a tool to help lower those costs. However, the coalition received feedback that some solar companies were using deceptive and unfair practices when marketing, selling, or financing solar energy, costing residents more money than utility rates and increasing the energy burden. This project sought to address rooftop solar community priorities through two pathways: 1. facilitating community engagement to understand community perspectives and experiences with rooftop solar development; and 2. conducting a financial cash-flow analysis highlighting the varying fiscal outcomes for rooftop solar adopters based off rooftop solar leasing, ownership, or buying electricity from the utility (National Grid).

14 SOLAR ENERGY↗

Policy and Cost Allocation Considerations for Large Electric Load Interconnections: Emerging Policy Trends in Rate Structures, Interconnection, and Cost Impacts on Other System Users

Load growth in the United States is rapidly increasing: load from data centers alone has tripled over the past decade, and this growth is forecasted to continue accelerating. These and other large electric loads (LELs) promise economic benefits at the state and local level, but their deployment has also led to increasing concerns about grid impacts and potential cost shifts onto other ratepayers. Legislators, regulators, and other stakeholders are increasingly proposing and enacting policies in effort to balance these and other considerations. This white paper reviews state-level legislation, selected utility rate cases, and relevant federal orders in an effort to describe and categorize relevant trends in policies related to LEL cost allocation, interconnection, and deployment. Policy categories identified through this review include tax incentives, rate actions, and requirements related to interconnection, permitting, and reporting. By offering a taxonomy of policies, this white paper aims to offer a resource to policymakers and other stakeholders navigating this transformative moment for the grid.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Voltage reapplication rate control for commutation of thyristors

A circuit for commutating a thyristor (21) by shunting its current for a minimum interval, thereby removing sustaining voltage to said thyristor, then subsequently restoring voltage to said thyristor at a predetermined rate, utilizes a series combination of a commutation electronic switch (22) and an isolated dc voltage supply (23) connected in parallel with the thyristor. The voltage supply is arranged with a polarity that permits the current flowing through the thyristor in one direction to be bypassed through the series combination while the commutation switch is turned on and to reverse bias the thyristor when the commutation switch is fully on. A dv/dt control circuit (24) limits the rate of rise of voltage across the commutation switch (22) as it is turned off in response to a command input signal. The dv/dt control circuit is comprised of a constant current drive (31) and a capacitor (32) connected between the output terminal of the commutation switch and the control input terminal of the commutation switch. The thyristor may be a triac (40) with two commutation switches (42, 43), one for current of each polarity, or with a single commutation switch (55) and a bridge circuit (52-55) for selecting the polarity of the switch (56).

Rippel, Wally E.↗

Grid Value Analysis of Medium-Voltage Back-to-Back Converter on DER Hosting Enhancement

This paper presents an analysis of the value that can be realized by medium-voltage back-to-back (MVB2B) converters in terms of the increased utilization rate of distributed energy resources (DERs) and the improvement in operational conditions. A systematic, transferrable, and scalable methodology has been designed to analyze and quantify the increased DER value from three perspectives: 1) curtailment reduction of the DER generation, 2) size reduction of the energy storage needed to otherwise realize DER hosting levels, and 3) hosting capacity improvement of the DERs compared to the base distribution circuit capability. In the case study, the proposed methodology is applied to two utility distribution systems for analysis and quantification of the grid value of the MVB2B converter, installed in the distribution circuit, and provided to the solar photovoltaic (PV) DERs. Here, the analysis results demonstrate that the MVB2B converter can deliver significant value to the PV hosting enhancement of two adjacent distribution systems when they are connected by the MVB2B converter. Based on this case study, this paper analyzes and summarizes the approximate realized grid value of the MVB2B converter for distribution systems dominated by different shares of customer classes.

24 POWER TRANSMISSION AND DISTRIBUTION↗