At least 55 records · Page 3

CROCUS Air Quality Dataset from the University of Illinois Chicago (UIC), July 2024

This dataset was collected by the measurement system in the Atmosphere, Climate, and Ecosystems (ACE) Lab at the University of Illinois Chicago (UIC) from July 12 to July 31, 2024, as part of the Community Research on Climate and Urban Science (CROCUS) Urban Integrated Field Laboratory (UIFL) project, led by Argonne National Laboratory.To enhance understanding of urban air quality dynamics in Chicago, and as part of the CROCUS 2024 Urban Canyon Intensive Observation Period (IOP), several instruments were set up to provide continuous measurements of air quality parameters in Chicago during July 2024. These measurements cover both aerosols and gas-phase species. It focuses on particle size distribution (2.5–478 nm) measured by two Scanning Mobility Particle Sizers (SMPS) at a 4-min resolution, total particle number concentrations at a 1-s resolution, and chemical composition from a High-Resolution Time-of-Flight Aerosol Mass Spectrometer (AMS) at a 1-min resolution. Key gas-phase species, including NO, NO₂, SO₂, and O₃, are measured at a 1-min resolution, along with high-resolution NO and dimethyl sulfide (DMS) data from a Chemical Ionization Mass Spectrometer (CIMS). Volatile organic compound (VOC) data for toluene, isoprene, and benzene are provided by a GC-PID with a time resolution of 25 minutes.The data are formatted as NetCDF (.nc) files, making them easily accessible using common software such as MATLAB, R, and Python. Each parameter is stored in an individual dataset, which includes detailed instrument information in the header, as well as the corresponding sample start time and concentration/distribution data for each sample.

54 ENVIRONMENTAL SCIENCES↗

Impact of Electric Vehicle Charging Station Reliability, Resilience, and Location on Electric Vehicle Adoption

While the majority of electric vehicle (EV) charging events in the United States occur at home, issues with public charging stations are consistently found to be a top reason that potential EV buyers do not purchase an EV, demonstrating that both EVSE reliability and availability impacts EV adoption. This report explores multiple parameters that impact EVSE reliability and deployment, which in turn impact EV sales. These include extreme weather, codes and standards, region (urban vs. rural), and grid network type. Grid reliability was not found to impact EV adoption. The relationships between EV station reliability, station resilience, grid resilience, and EV adoption are largely outside the scope of the National Renewable Energy Laboratory's (NREL's) Automotive Deployment Options Projection Tool (ADOPT) and other vehicle adoption models, so the methodology of this report is varied. Section 2 sets the baseline for infrastructure reliability, user satisfaction, and maintenance practices. Section 3 explores the ways that electric vehicle supply equipment (EVSE) reliability impacts the relationship between EVSE and EV adoption. Section 4 shows how geographical categories such as urban, rural, large grid, off-grid, or microgrid can be helpful in EVSE deployment strategies, as well as how the relationship between EVSE and EV adoption differs among these categories. Section 5 investigates the impacts of grid reliability and infrastructure resilience on EV adoption. Finally, Section 6 reverses the perspective to examine the impact that EVs and EVSE have on grid resilience and reliability. As recent funding initiatives result in an expansion of public chargers across the United States, as well as an increase in the uptime of existing chargers, EV adoption will likely grow.

33 ADVANCED PROPULSION SYSTEMS↗

Sensitivity of Riparian Buffer Designs to Climate Change—Nutrient and Sediment Loading to Streams: A Case Study in the Albemarle-Pamlico River Basins (USA) Using HAWQS

Riparian buffer zones (RBZs) provide multiple benefits to watershed ecosystems. We aimed to conduct an extensive sensitivity analysis of the RBZ designs to climate change nutrient and sediment loadings to streams. We designed 135 simulation scenarios starting with the six baselines RBZs (grass, urban, two-zone forest, three-zone forest, wildlife, and naturalized) in three 12-digit Hydrologic Unit Code watersheds within the Albemarle-Pamlico river basin (USA). Using the hydrologic and water quality system (HAWQS), we assessed the sensitivity of the designs to five water quality indicator (WQI) parameters: dissolved oxygen (DO), total phosphorous (TP), total nitrogen (TN), sediment (SD), and biochemical oxygen demand (BD). To understand the climate mitigation potential of RBZs, we identified a subset of future climate change projection models of air temperature and precipitation using EPA’s Locating and Selecting Scenarios Online tool. Analyses revealed optimal RBZ designs for the three watersheds. In terms of watershed ecosystem services sustainability, the optimal Urban RBZ in contemporary climate (1983–2018) reduced SD from 61–96%, TN from 34–55%, TP from 9–48%, and BD from 53–99%, and raised DO from 4–10% with respect to No-RBZ in the three watersheds. The late century’s (2070–2099) extreme mean annual climate changes significantly increased the projected SD and BD; however, the addition of urban RBZs was projected to offset the climate change reducing SD from 28–94% and BD from 69–93% in the watersheds. All other types of RBZs are also projected to fully mitigate the climate change impacts on WQI parameters except three-zone RBZ.

54 ENVIRONMENTAL SCIENCES↗

Fast Gaussian Process Estimation for Large-Scale In Situ Inference using Convolutional Neural Networks

Exascale computing will bring with it significant I/O limitations. One foreseeable consequence of such restrictions is that the user can save only a small fraction of complex simulation data to disk for subsequent analysis. An alternative is to fit statistical models to data in situ, that is, inside the simulation as it runs. This option requires extremely fast statistical estimation to avoid slowing down the simulation. Gaussian processes (GPs) have state-of-the-art predictive performance for modeling spatial data. However, standard estimation methods for GPs scale quite poorly to large data sets as parameter estimation requires inverting a covariance matrix to the size of the data set. In the presented work, we use a convolutional neural network (CNN) to predict the GP parameters for a spatial data set, from a simulation or otherwise, rather than optimize the parameters directly. Here, our presented case study models spatial data from E3SM, the Department of Energy’s Exascale climate model. The CNN is trained on synthetic data simulated from GP models with known parameters and then applied to data from the climate simulation. In the presented examples, the neural network scheme produces parameter estimates that compare well with standard methods such as maximum likelihood estimation in predictive performance but is obtained four orders of magnitude faster.

big data↗

CROCUS Weather Data at Northwestern University Rooftop

This dataset is from the Department of Energy Office of Science funded project, Community Research on Urban and Climate Science (CROCUS) (https://crocus-urban.org/). Vaisala WXT sensor is an all-in-one weather instrument that provides 6 of the most important weather parameters: barometric pressure, temperature, relative humidity, rainfall, wind speed and direction. Temperature, pressure, relative humidity, and rainfall are sampled at 1 second frequency, while wind speed/direction is measured at ten per second (10Hz) frequency. These measurements are useful for looking at characterizing local weather, identifying unique weather events, and studying local turbulence, especially given the high temporal resolution of the wind measurements. Datasets are stored in the netCDF data format, and we we encourage users to make use the associated toolkits available from Unidata (https://www.unidata.ucar.edu/software/netcdf/), Project Pythia (https://foundations.projectpythia.org/core/data-formats/netcdf-cf.html), and our “Instrument Cookbooks” (https://crocus-urban.github.io/instrument-cookbooks) for more information on how to process the metadata-rich datasets.

EARTH SCIENCE > ATMOSPHERE > ATMOSPHERIC TEMPERATU↗

CROCUS Weather Data at Northeastern Illinois University Rooftop

This dataset is from the Department of Energy Office of Science funded project, Community Research on Urban and Climate Science (CROCUS) (https://crocus-urban.org/). Vaisala WXT sensor is an all-in-one weather instrument that provides 6 of the most important weather parameters: barometric pressure, temperature, relative humidity, rainfall, wind speed and direction. Temperature, pressure, relative humidity, and rainfall are sampled at 1 second frequency, while wind speed/direction is measured at ten per second (10Hz) frequency. These measurements are useful for looking at characterizing local weather, identifying unique weather events, and studying local turbulence, especially given the high temporal resolution of the wind measurements.Datasets are stored in the netCDF data format, and we we encourage users to make use the associated toolkits available from Unidata (https://www.unidata.ucar.edu/software/netcdf/), Project Pythia (https://foundations.projectpythia.org/core/data-formats/netcdf-cf.html), and our “Instrument Cookbooks” (https://crocus-urban.github.io/instrument-cookbooks) for more information on how to process the metadata-rich datasets.

54 ENVIRONMENTAL SCIENCES↗

Data-Driven Optimal Control of Traffic Signals for Urban Road Networks

This paper studies the issue of data-driven optimal control design for traffic signals of oversaturated urban road networks. The signal control system based on the store and forward model is generally uncontrollable for which the controllable decomposition is needed. Instead of identifying the unknown parameters like saturation rates and turning ratios, a finite number of measured trajectories can be used to parametrize the system and help directly construct a transformation matrix for Kalman controllable decomposition through the fundamental lemma of J. C. Willems. On top of that, an infinite-horizon linear quadratic regulator (LQR) problem is formulated considering the constraints of green times for traffic signals. The problem can be solved through a two-phase data-driven learning process, where one solves an infinite-horizon unconstrained LQR problem and the other solves a finite-horizon constrained LQR problem. The simulation result shows the theoretical analysis is effective and the proposed data-driven controller can yield desired performance for reducing traffic congestion.

Liu, Tong↗

Low-cost embedded optical sensing systems for distribution transformer monitoring

There is a mounting need for low-cost monitoring with online sensing technologies to maintain grid reliability and uptime. Here we introduce an innovative low-cost, embedded optical sensing technology initially focused on transformers that was developed and demonstrated at a major electric utility, Con Edison. A version of it that can be retrofitted onto existing transformers in the field was also developed. Two new 500 kVA distribution network transformers were built with embedded fiber-optic (FO) sensors and qualified per industry standards. Vibration, temperature, and corrosion were key parameters monitored. The first transformer with embedded FO sensors was installed at a Con Edison facility and monitored at our team’s office. The second one was installed in an urban street-side underground location with online data processing/feature extraction algorithms and monitored through a wireless router. Additionally, an older transformer was also retrofitted. Data analysis was done on these transformers showing promising correlations with their corresponding loading cycles. Furthermore, key events such as the transformer primary-side energizing, and other events were detected. In general, the technology was demonstrated over 6 months across the 3 transformers instrumented with promising results. Thus, it has the potential to enable predictive maintenance for transformers and other grid assets.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Using Residential and Office Building Archetypes for Energy Efficiency Building Solutions in an Urban Scale: A China Case Study

Building energy consumption accounts for 36% of the overall energy end use worldwide and is growing rapidly as developing countries continue to urbanize. Understanding the energy use at urban scale will lay the foundation for identification of energy efficiency opportunities to be deployed at speed. China has almost half of global new constructions and plays an important role in building suitability. However, an open source national building energy consumption database is not available in China. To provide data support for building energy consumptions, this paper used a simulation method to develop an urban building energy consumption database for a pilot city in Wuhan, China. First, residential, small, and large office building archetype energy models were created in EnergyPlus to represent typical building energy consumption in Wuhan. The baseline reference model simulation results were further validated using survey data from the literature. Second, stochastic simulations were conducted to consider different design parameters and occupants’ energy usage intensity scenarios, such as thermal properties of the building envelope, lighting power density, equipment power density, HVAC (heating, ventilation and air conditioning) schedule, etc. A building energy consumption database was generated for typical building archetypes. Third, data-driven regression analysis was conducted to support quick building energy consumption prediction using key high- level building information inputs. Finally, a web-based urban energy platform and an interface were developed to support further third-party application development. The research is expected to provide fast energy efficiency building design solutions for urban planning, new constructions as well as building retrofits.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Sensitivity of Fine‐Resolution Urban Heat Island Simulations to Soil Moisture Parameterization

ABSTRACT Urban areas experience the impact of natural disasters, such as heatwaves and flash floods, disparately in different neighbourhoods across a city. The demand for precise urban hydrometeorological and hydroclimatological modelling to examine this disparity, and the interacting challenges posed by climate change and urbanisation, has thus surged. The Weather Research and Forecasting (WRF) model has served such operational and research purposes for decades. Recent advancements in WRF, including enhanced numerical schemes and sophisticated urban atmospheric‐hydrological parameterizations, have empowered the simulation of urban geophysical processes at high resolution (~1 km), but even this resolution misses significant urban microclimate variability. This study applies the large‐eddy simulations (LES) mode within WRF, coupled with single‐layer urban canopy models (SLUCM), to enable even finer‐scale modelling (150 m) of the Urban Heat Island (UHI) effect in the Baltimore metropolitan area. We run nine scenarios to evaluate various methods of initializing soil moisture and various spinup lead times, and to assess the impact of WRF's Mosaic approach in depicting subgrid‐scale processes. We evaluate the scenarios by comparing the WRF simulated land surface temperature (LST) against Landsat LST and the WRF simulated hourly 2‐m air temperatures (AT) with observations from eight weather stations across the domain. Results underscore the paramount influence of the lead spinup time on the spatiotemporal distribution of simulated soil moisture, consequently shaping WRF's efficacy in predicting the UHI. Furthermore, interpolating soil moisture‐related parameters from the parent for child domain initialization yields a notable reduction in mean and root‐mean‐squared errors. This improvement was particularly evident in simulations with the longest spinup time, affirming the importance of carefully designing the initialization of soil moisture for improved urban temperature predictions.

Talebpour, Mahdad↗

Design and Performance of lithium-Ion Batteries for Achieving Electric Vehicle Takeoff, Flight, and Landing

Today, the burgeoning drive towards global urbanization with over half the earth’s population living in cities, has created major challenges with regards to intracity and intercity transit and mobility. This problem is compounded due to the fact that almost always urbanization and increase in standard of living drives individual automobile ownerships. Over 95% of automobiles are presently powered by some form of fossil fuel and as an unintended consequence, urban centers have also been centers for peak greenhouse gas emissions, a major contributor to global climate change. A revolutionary solution to this conundrum is flight capable electric automobiles or electric aerial vehicles that can tackle both urban mobility and climate change challenges. For such advanced electric platforms, energy storage and delivery component is the vital component towards achieving takeoff, flight, cruise, and landing. The requirements and duty cycle demands on the energy storage system is drastically different when compared to the performance metrics required for terrestrial electric vehicles. As the widely deployed lithium ion-based battery systems are often the primary go-to energy storage choice in electric vehicle related applications, it is imperative that performance metrics and specifications for such batteries towards areal electric vehicles need to be established. In this nascent field, there exists ample opportunities for battery material innovations, understanding degradation mechanism, battery design, development and deployment of battery control and management systems. Thus, this chapter comprehensively discusses battery requirements and identifies battery material chemistries suitable for handling aerial electric automobile duty cycles. The chapter also discusses the battery cell-level metrics pertaining to electrochemical, chemical, mechanical, and structural parameters. Furthermore, specific models for battery degradation, state of health (SOH), capacity and models for full cell performance and degradation are also discussed here. Finally, the chapter also discusses battery safety and future directions of batteries that would power these next generation urban electric aircrafts.

Amin, Ruhul↗

Optimizing green infrastructure placement under precipitation uncertainty

Increased urbanization, infrastructure degradation, and climate change threaten to overwhelm stormwater systems across the nation, rendering them ineffective. Green Infrastructure (GI) practices are low cost, low regret strategies that can contribute to urban runoff management. However, questions remain as to how to best distribute GI practices through urban watersheds given precipitation uncertainty and the variable hydrological responses to them. We develop stochastic programming models to determine the optimal placement of GI practices across a set of candidate locations in a watershed to minimize the total expected runoff under medium-term precipitation uncertainties. Specifically, we first develop a two-stage stochastic programming model. Next, we reformulate this model using perturbed parameters to reduce the requisite computational time and extend it to multi-stage. In addition, we introduce constraints that allow for incorporating sub-catchment-level runoff reduction considerations. Furthermore, we account for hydrological connectivity in the watershed using an underlying acyclic connectivity graph of sub-catchments and incorporate various practical considerations into the models. In addition, we develop a systemic approach to downscale the existing daily precipitation projections into hourly units and efficiently estimate the corresponding hydrological responses. These advancements are brought together in a case study for an urban watershed in a mid-sized city in the U.S., where we perform sensitivity analyses, evaluate the importance of the considered constraints, and provide insights.

54 ENVIRONMENTAL SCIENCES↗

NATURF

The Neighborhood Adaptive Tissues for Urban Resilience Futures tool (NATURF) is a Python workflow that generates les readable by the Weather Research and Forecasting (WRF) model. The NATURF Python modules use shapefiles containing building footprint and height data as input to calculate 132 building parameters at any resolution and converts the parameters into a binary file format.

Allen-Dumas, MelissaRee [Oak Ridge National Lab. (↗

Correcting for filter-based aerosol light absorption biases at the Atmospheric Radiation Measurement program's Southern Great Plains site using photoacoustic measurements and machine learning

Abstract. Measurement of light absorption of solar radiation by aerosols is vital for assessing direct aerosol radiative forcing, which affects local and global climate. Low-cost and easy-to-operate filter-based instruments, such as the Particle Soot Absorption Photometer (PSAP), that collect aerosols on a filter and measure light attenuation through the filter are widely used to infer aerosol light absorption. However, filter-based absorption measurements are subject to artifacts that are difficult to quantify. These artifacts are associated with the presence of the filter medium and the complex interactions between the filter fibers and accumulated aerosols. Various correction algorithms have been introduced to correct for the filter-based absorption coefficient measurements toward predicting the particle-phase absorption coefficient (Babs). However, the inability of these algorithms to incorporate into their formulations the complex matrix of influencing parameters such as particle asymmetry parameter, particle size, and particle penetration depth results in prediction of particle-phase absorption coefficients with relatively low accuracy. The analytical forms of corrections also suffer from a lack of universal applicability: different corrections are required for rural and urban sites across the world. In this study, we analyzed and compared 3 months of high-time-resolution ambient aerosol absorption data collected synchronously using a three-wavelength photoacoustic absorption spectrometer (PASS) and PSAP. Both instruments were operated on the same sampling inlet at the Department of Energy's Atmospheric Radiation Measurement program's Southern Great Plains (SGP) user facility in Oklahoma. We implemented the two most commonly used analytical correction algorithms, namely, Virkkula (2010) and the average of Virkkula (2010) and Ogren (2010)–Bond et al. (1999) as well as a random forest regression (RFR) machine learning algorithm to predict Babs values from the PSAP's filter-based measurements. The predicted Babs was compared against the reference Babs measured by the PASS. The RFR algorithm performed the best by yielding the lowest root mean square error of prediction. The algorithm was trained using input datasets from the PSAP (transmission and uncorrected absorption coefficient), a co-located nephelometer (scattering coefficients), and the Aerosol Chemical Speciation Monitor (mass concentration of non-refractory aerosol particles). A revised form of the Virkkula (2010) algorithm suitable for the SGP site has been proposed; however, its performance yields approximately 2-fold errors when compared to the RFR algorithm. To generalize the accuracy and applicability of our proposed RFR algorithm, we trained and tested it on a dataset of laboratory measurements of combustion aerosols. Input variables to the algorithm included the aerosol number size distribution from the Scanning Mobility Particle Sizer, absorption coefficients from the filter-based Tricolor Absorption Photometer, and scattering coefficients from a multiwavelength nephelometer. The RFR algorithm predicted Babs values within 5 % of the reference Babs measured by the multiwavelength PASS during the laboratory experiments. Thus, we show that machine learning approaches offer a promising path to correct for biases in long-term filter-based absorption datasets and accurately quantify their variability and trends needed for robust radiative forcing determination.

54 ENVIRONMENTAL SCIENCES↗

A Bayesian model for multivariate discrete data using spatial and expert information with application to inferring building attributes

When modeling sparsely observed multivariate data, strong prior information elicited from experts can be used to bolster predictive accuracy and counteract sampling bias. Similarly, modeling autocorrelation in space can help make use of co-occurrence patterns present in many types of spatial data. To make use of both expert prior information and spatial structure, we propose a novel graphical model for a spatial Bayesian network developed specifically to address challenges in inferring the attributes of buildings from geographically sparse observational data. This model is implemented as the sum of a spatial multivariate Gaussian random field and a tabular conditional probability function in real-valued space prior to projection onto the probability simplex. This modeling form is especially suitable for the usage of prior information in the form of sets of atomic rules obtained from experts. To perform inference with missing data, we implement a Markov chain Monte Carlo scheme composed of alternating steps of Gibbs sampling of missing entries and Hamiltonian Monte Carlo for model parameters. A case study in building attribution is presented to highlight the advantages and limitations of this approach.

97 MATHEMATICS AND COMPUTING↗

An adaptive synchronous extraction (ASE) method for estimating intensity and footprint of surface urban heat islands: A case study of 254 North American cities

The urban heat island (UHI) effect has attracted great attention due to its potential impacts on rapidly growing urban areas. Using remotely sensed estimates of land surface temperature (LST), a large number of studies have focused on the surface UHI (SUHI) effect, which can be characterized by its two fundamental properties: intensity and footprint. The SUHI intensity reflects the LST difference between the urban area and the background reference area (BRA), and the SUHI footprint indicates the spatial extent influenced by the heat island. Currently, numerous methods have been developed to estimate the SUHI intensity and footprint, but are still greatly challenged by three main issues. Namely, the discrepancy in BRA selection criterion brings great uncertainty to the estimated SUHI intensity, the estimation of SUHI footprint is largely constrained by the predefined models, and the quantification of SUHI effect is potentially influenced by several confounding factors. Here, we proposed an adaptive synchronous extraction (ASE) method, which is capable of adaptively selecting the most optimal BRA while removing the influence of confounding factors, and achieving synchronous estimation of SUHI intensity and footprint. We applied the ASE method to 254 North American cities and conducted an in-depth comparative analysis to discuss its applicability and benefits. The main results include: (1) The ASE method avoids the limitations of existing methods in BRA selection and model presetting, and shows resilience to parameter variations. This makes the ASE method highly applicable to quantify the SUHI intensity and footprint in cities with various thermal characteristics. (2) The ASE method can better highlight the spatial, seasonal and day-night contrasts in the estimated SUHI intensity. This superiority is particularly evident when comparing it to methods based on the equal-area buffer or the simplified urban-extent algorithm. (3) Confounding factors pose non-negligible impacts on the quantification of the SUHI effect. Typically, ignoring the influence of topographic relief or missing LST data can lead to an overall overestimation of the SUHI intensity, while not removing surrounding urban areas will cause some underestimation of the SUHI intensity. In conclusion, overall, the proposed ASE method provides a new generalizable tool for quantifying the SUHI effect, which has great potentials for future studies and urban climate assessments.

54 ENVIRONMENTAL SCIENCES↗

A ``Tail" of Two Cities: Fatality-based Modeling of COVID-19 Evolution in New York City and Cook County, IL

I describe $SIR$ modeling of the COVID-19 pandemic in two U.S. urban environments, New York City (NYC) and Cook County, IL, from onset through the month of June, 2020. Since testing was not widespread early in the pandemic in the U.S., I do not use data on confirmed cases and rely solely on public fatality data to estimate model parameters. Fits to the first 20 days of data determine a degenerate combination of the basic reproduction number, $R_0$, and the mean time to removal from the infectious population, $\gamma^{-1}$, with $\gamma (R_0-1) = 0.25 (0.21)$ inverse days for NYC (Cook County). Equivalently, the initial doubling time was $t_d = 2.8 (3.4)$ days for NYC (Cook). The early fatality data suggest that both locations had infections in early February. I model the mitigation measures implemented in mid-March in both locations (distancing, quarantine, isolation, etc) via a time-dependent reproduction number $R_t$ that declines monotonically from $R_0$ to a sma ller asymptotic value, with a parameterized functional form. The timing (mid-March) and duration (several days) of the transitions in $R_t$ appear well determined by the data. However, the fatality data determine only a degenerate combination of the parameters $R_0$, the percentage reduction in social contact due to mitigation measures, $X$, and the infection fatality rate (IFR), $f$. With flat priors, based on simulations the NYC model parameters have 95.45\% credible intervals of $R_0 = 3.0-5.4$, $X= 80-99.9\%$ and $f=2-6\%$, with $5-13\%$ of the population asymptotically infected. A strong external prior indicating a lower value of $f$ or of $\gamma^{-1}$ would imply lower values of $R_0$ and $X$ and higher percentage infection of the population. For Cook County, the evolution was qualitatively different: after mitigation measures were implemented, the daily fatality counts reached a plateau for about a month before tailing off. This is consistent with an $SIR$ model that exhibits ``critical slowing-down", in which $R_t$ plateaus ! at a value just above unity. For Cook County, the 95.45\% credible intervals for the model parameters are much broader and shifted downward, $R_0=1.4-4.7$, $X=26-54\%$, and $f=0.1-0.6\%$ with $15-88\%$ of the population asymptotically infected. Despite the apparently lower efficacy of its social contact reduction measures, Cook County has had significantly fewer fatalities per population than NYC, $D_\infty/N=100$ vs. 270 per 100,000. In the model, this is attributed to the lower inferred IFR for Cook; an external prior pointing to similar values of the IFR for the two locations would instead chalk up the difference in $D/N$ to differences in the relative growth rate of the disease. I derive a model-dependent threshold, $X^{crit}_e$, for `safe' re-opening, that is, for easing of contact reduction that would not trigger a second wave; for NYC, the models predict that increasing social contact by more than 20\% from post-mitigation levels will lead to renewed spread, while for Cook County the threshold value is very uncertain, given the parameter degeneracies. The timing of 2nd-wave growth will depend on the amplitude of contact increase relative to $X^{crit}_e$ and on the asymptotic growth rate, and the impact in terms of fatalities will depend on the parameter $f$.

Frieman, Joshua↗

Automatic and rapid calibration of urban building energy models by learning from energy performance database

Urban building energy modeling (UBEM) is attracting increasing attention in the energy modeling filed. Unlike modeling a single building using detailed building systems information, UBEM generally uses limited high-level building stock data to infer default assumptions about building characteristics and operations. Additionally, this practice inherently brings uncertainty to UBEM. This study introduced a novel method of automatic and rapid calibration of UBEM based on the annual electricity and natural gas energy use data by learning the correlations between crucial model input parameters and the building energy use from the reference building models. A case study was presented to calibrate 72 large office buildings built before 1978 in San Francisco. Seventeen model parameters were selected and Monte Carlo sampling was used to create 1000 samples that reasonably represent the parameter space. Then 1000 simulations were performed for the reference building model to create an energy performance database. The results showed that by learning from the energy performance database, it took less than four simulation runs on average to calibrate a building model. After the calibration, the distributions of each parameter were obtained to replace their single predefined default values. For example, the default lighting power density of 21.39 W/m 2 was calibrated to be 7.50 W/m 2 on average. The case study successfully demonstrated the effectiveness of the novel calibration method for UBEM in the mild climate. The method will be further tested in future for other climate zones and other building types.