Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “u-shaped”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

50 records · Page 3

Ground heat exchanger design tool with rowwise placement of boreholes

Simulation-based design tools have been used since the late 1980s for designing ground heat exchangers (GHE) used with ground source heat pump (GSHP) systems. The ground heat exchanger simulations used in these tools rely on thermal response functions known as g-functions. Because of the significant computational burden in computing g-functions for even a single configuration, the design tools have relied on libraries of pre-computed g-functions. These g-functions were available for standard configuration shapes, such as lines, rectangles, open rectangles, L-shapes, and U-shapes. Standard shapes are often sub-optimal. For any building on a site, the available land may preclude use of a standard shape. For large GSHP systems with significantly imbalanced annual heat rejection and extraction loads, large rectangular fields may experience significant heat build-up (or heat draw-down) in the interior of the field. This paper describes a new ground heat exchanger design tool capable of automatically selecting and sizing both standard and irregular configurations. The focus of this paper is a method for creating, selecting and sizing irregular configurations where the available land area and "no-go" zones are described as irregular polygons.

Spitler, Jeffery↗

Open library of g-functions for 34,321 configurations

Thermal response functions, known as g-functions, are commonly used in ground heat exchanger design tools and whole building energy simulation programs to simulate the ground heat exchanger performance. Calculation of g-functions can be quite computationally time-consuming, particularly as the number of boreholes gets large. However, once the g-function is computed, the actual simulation time can be quite short, particularly if a hybrid time-step (Cullin and Spitler 2011) approach is used. Because of this, pre-computed g-function libraries are commonly used in design tools and building simulation tools. This paper describes development of a new, publicly available library containing g-functions for 34,321 borehole field configurations; for each configuration, gfunctions are provided for 5 depths to allow interpolation between different borehole-to-height ratios. The available configurations include configurations in standard shapes: lines, rectangles, open rectangles, L-shapes, and U-shapes. It also includes new configurations: C-shapes, lopsided-U-shapes, and zoned rectangles, which are rectangular configurations with different interior and perimeter spacing of the boreholes.

Spitler, Jeffery↗

Electromagnetic Design Optimization Integrated with Mechanical Stress Analysis of PM-Assisted Synchronous Reluctance Machine Topologies Enabled with a Blend of Magnets

Permanent Magnet-Assisted Synchronous Reluctance Machines (PMASynRM) provide a low-cost alternative to Surface PM Machines due to the use of relatively lower grades of rare-earth (RE) or RE-free magnets, as the performance degradation due to weaker magnets is compensated by the presence of reluctance torque. However, the weaker magnets suffer from a high risk of demagnetization, leading to unreliable motor operation. Using a blend of RE and RE-free magnets has the potential to overcome this issue. This paper proposes to blend different grades of various rare-earth (RE) and rare-earth-free (RE-free) magnets in six different combinations and utilizes them in two-layer and three-layer U-shaped PMASynRM topologies with both eight-pole and six-pole variations. The rotor of the various designs is then optimized using a differential evolution (DE) based optimization algorithm to obtain low-cost designs with reduced RE magnet volume and minimum demagnetization risk. The optimization of each design is also integrated with the evaluation of mechanical stresses in the rotor laminations so as to maintain the stresses below the material yield strength. Furthermore, the various performance metrics, such as toque–speed/power–speed characteristics, demagnetization, and efficiency maps, are evaluated for each of the optimized and mechanically feasible designs. A quantitative comparison of the various optimized designs is also obtained to highlight the various trade-offs. The results indicate the feasibility of meeting the baseline torque requirement across the entire speed range, even with a 100% reduction in RE magnet volume and less than 5% demagnetization risk, while achieving a cost reduction exceeding 50%. Moreover, the two-layer, eight-pole designs exhibit relatively higher performance, whereas the three-layer, eight-pole designs are found to be the most economical option.

design optimization↗

On the Feasibility of Deep Geothermal Wells Using Numerical Reservoir Simulation

This study examines the geothermal energy extraction potential from the basement rock within the Denver–Julesburg Basin, focusing on the flow performance and heat extraction efficiency of different geothermal well configurations. It specifically compares U-shaped, V-shaped, inclined V-shaped, and pipe-in-pipe configurations against enhanced geothermal system setups. Through numerical modeling, we evaluated the thermal behavior of these systems under various operational scenarios and fracture conditions. The results suggest that while closed-loop systems offer moderate temperature increases, Enhanced geothermal system configurations show substantial potential for high-temperature extraction. This underscores the importance of evaluating well configurations in complex geological settings. The insights from this study aid in strategic geothermal energy planning and development, marking significant advancements in geothermal technology and setting a foundation for future explorations and optimizations.

15 GEOTHERMAL ENERGY↗

Warped and Hooked: Mapping the Magellanic Clouds in Three Dimensions Using Red Clump Stars

The Large Magellanic Cloud (LMC) and Small Magellanic Cloud (SMC) are the Milky Way’s nearest interacting galaxy pair, offering a unique laboratory for studying tidal effects on galactic disks. Despite extensive survey efforts, the 3D geometry of the Magellanic Clouds, particularly the putative warp of the LMC, remains poorly constrained due to incompleteness in their crowded centers and the low stellar density of their peripheries, which demand wide-field coverage. Using red clump (RC) stars as standard candles, corrected for age- and metallicity-dependent population effects with empirically calibrated color–magnitude relations and spatially resolved star formation histories, we construct the most detailed distance map of the Magellanic system to date. Based on ∼2.3 million RC stars from Gaia Data Release 3 combined with modern reddening maps, we measure median heliocentric distances of 50.62 ± 2.32 kpc for the LMC (to ∼23°) and 60.75 ± 2.85 kpc for the SMC (to ∼12°). The maps reveal substructures including the LMC Northern Arm, southern hooks, the Magellanic Bridge, and SMC peripheral overdensities, with refreshed distance estimates. Fitting the LMC disk within 7° yields a global inclination of $i=25\mathop{.}\limits^{^\circ }32\pm 0\mathop{.}\limits^{^\circ }10$ and a line-of-nodes position angle of $\theta = 142\mathop{.}\limits^{^\circ }34\pm 0\mathop{.}\limits^{^\circ }21$. Most strikingly, we find the LMC periphery is warped azimuthally into a U-shaped structure reaching a vertical amplitude of ∼7 kpc at a radius of ∼15 kpc. In future work, we will perform detailed comparisons with live N-body simulations to assess possible formation scenarios for the LMC warp.

79 ASTRONOMY AND ASTROPHYSICS↗

Daytime variation in the aerosol indirect effect for warm marine boundary layer clouds in the eastern North Atlantic

Abstract. Warm boundary layer clouds in the eastern North Atlantic region exhibit significant diurnal variations in cloud properties. However, the diurnal cycle of the aerosol indirect effect (AIE) for these clouds remains poorly understood. This study takes advantage of recent advancements in the spatial resolution of geostationary satellites to explore the daytime variation in the AIE by estimating the cloud susceptibilities to changes in cloud droplet number concentration (Nd). Cloud retrievals for the month of July over 4 years (2018–2021) from the Spinning Enhanced Visible and Infrared Imager (SEVIRI) on Meteosat-11 over this region are analyzed. Our results reveal a significant “U-shaped” daytime cycle in susceptibilities of the cloud liquid water path (LWP), cloud albedo, and cloud fraction. Clouds are found to be more susceptible to Nd perturbations at noon and less susceptible in the morning and evening. The magnitude and sign of cloud susceptibilities depend heavily on the cloud state defined by cloud LWP and precipitation conditions. Non-precipitating thin clouds account for 44 % of all warm boundary layer clouds in July, and they contribute the most to the observed daytime variation. Non-precipitating thick clouds are the least frequent cloud state (10 %), and they exhibit more negative LWP and albedo susceptibilities compared to thin clouds. Precipitating clouds are the dominant cloud state (46 %), but their cloud susceptibilities show minimal variation throughout the day. We find evidence that the daytime variation in LWP and albedo susceptibilities for non-precipitating clouds is influenced by a combination of the diurnal transition between non-precipitating thick and thin clouds and the “lagged” cloud responses to Nd perturbations. The daytime variation in cloud fraction susceptibility for non-precipitating thick clouds can be attributed to the daytime variation in cloud morphology (e.g., overcast or broken). The dissipation and development of clouds do not adequately explain the observed variation in cloud susceptibilities. Additionally, daytime variation in cloud susceptibility is primarily driven by variation in the intensity of cloud response rather than the frequency of occurrence of cloud states. Our results imply that polar-orbiting satellites with an overpass time at 13:30 LT underestimate daytime mean values of cloud susceptibility, as they observe susceptibility daily minima in the study region.

54 ENVIRONMENTAL SCIENCES↗

Heliostat Sizing Methodology for Solar Heat for Industrial Processes

This study presents a method to obtain a heliostat size that minimizes the levelized cost of a heliostat-based concentrating solar thermal system for industrial process heat (IPH) applications at operating temperatures from 565 to 1550 degrees Celsius. The method extends prior work by embedding a routine for system design that obtains near-optimal subsystem sizes, increasing the fidelity of drive cost functions, and adding an optical performance model. An illustrative business case is developed for Daggett, California, targeting specified annual thermal energy outputs of 50 to 400 GWhth. Optical performance is modeled using verified estimates from the literature. A surrogate heliostat cost model, derived from commercial heliostat designs and scaled for production volume, installation, and operations and maintenance costs, is used to develop cost functions. Results show that heliostat size strongly affects the levelized cost of heat (LCOH), producing a characteristic U-shaped trend with a robust near-optimal window of 8 - 12 m2; the heliostat size producing the lowest project cost in our study grows slightly as the project size increases, and is reduced as the operating temperature increases. The findings in this study are consistent with the general trend of smaller heliostats under deployment at existing projects for high-temperature industrial process heat and reflect the significant reduction in power electronics and other per-heliostat costs. The methodology we propose is general and can be tailored to revised cost curves as the technology continues to evolve.

14 SOLAR ENERGY↗

Heat exchanger

A heat exchanger includes a shell housing a plurality of tubes and defining an exhaust fluid flow path within a first volume enclosed by the shell. The outer surfaces of the plurality of tubes are in fluid communication with the exhaust fluid flow path. The heat exchanger includes a cap attached to a first end of the shell and defining a second volume. A header is configured to separate the first volume from the second volume, flex with thermal expansion, and define tube inlet and outlet positions. The tube inlets and outlets are in fluid communication with a source fluid flow path, and each tube is substantially U-shaped and defines a flow path of the source fluid within the exhaust fluid flow path. The heat exchanger includes at least one longitudinal flow baffle within the shell configured to reduce an amount of exhaust fluid that may bypass the tubes.

Borghese, Joseph↗

Stabilizers for a vehicle cooling module

A stabilizing arrangement of a cooling system module of a vehicle includes stabilizer pins attached to the vehicle cooling system module. Stabilizer slots are incorporated into a component of the chassis of the vehicle, such as a frame extender. The stabilizer slots may be formed as an upwards opening U-shape. Bushings are attached to the stabilizer pins. The stabilizer pins and bushings extend laterally into and engage with the stabilizer slots. Upon installation, the stabilizer pins and bushings are aligned with the stabilizer slots as the cooling system module is lowered onto the ISO mounts. The stabilizer pins and bushings slide vertically downwards into the stabilizer slots as the cooling system module is lowered into place. The simpler stabilizer pins, bushings, and stabilizer slots thereby take the place of expensive, time consuming, complex, labor intensive, and space consuming stay rod arrangements.

Wu, Shouhao↗

Techno-Economic Viability of Flexible Dispatch of Unconventional Geothermal Systems

Flexible geothermal operations could boost project returns through the allocation of improved power purchase agreements and/or exploitation of power price arbitrage opportunities. In this study, we investigated the techno-economic feasibility of variable flow rate control and time-of-day pricing in closed-loop geothermal systems. We considered U-shaped multilateral system configurations and modeled a variety of technical system parameters. These designs were simulated using a slender-body theory (SBT) model for transient heat transfer and fluid flow. This subsurface model was integrated into the flexible geothermal economic model (FGEM) tool to evaluate the overall flexible geothermal system techno-economics. Future hourly ambient temperature conditions were based on the Sup3rCC dataset. Published datasets were used for future hourly wholesale electricity prices. We analyzed four operating strategies: 1) baseload operation, 2) seasonal dispatch (high flow rate during summer and nominal flow rate during the rest of the year), 3) net generation maximization by varying flow rate to maximize net power output, and 4) revenue maximization by varying flow rate to maximize revenue. We ran all four scenarios for a multiloop configuration with 12 lateral passes, 7-km vertical depth and 87-km total drilling length. Furthermore, we assumed a 60 degrees C/km geothermal gradient and ambient temperature and wholesale electricity prices for New Mexico as a typical state location. The nominal flow rate was set to 80 kg/s. When considering drilling costs of $1,000/m and a discount rate of 7%, the generation maximization scenario resulted in the lowest levelized cost of electricity (LCOE) of ~$150/MWh. When considering project return on investment (ROI), defined as lifetime net income divided by upfront capital costs, all flexible operation scenarios performed better than the base case scenario. The highest ROI of 80% was obtained with the revenue maximization scenario. With drilling costs of $200/m and a discount rate of 5%, the generation maximization scenario resulted in LCOE of $49/MWh.

flexible geothermal↗

Closed Loop Geothermal Working Group: GeoCLUSTER App, Subsurface Simulation Results, and Publications

To better understand the heat production, electricity generation performance, and economic viability of closed-loop geothermal systems in hot-dry rock, the Closed-Loop Geothermal Working Group -- a consortium of several national labs and academic institutions has tabulated time-dependent numerical solutions and levelized cost results of two popular closed-loop heat exchanger designs (u-tube and co-axial). The heat exchanger designs were evaluated for two working fluids (water and supercritical CO2) while varying seven continuous independent parameters of interest (mass flow rate, vertical depth, horizontal extent, borehole diameter, formation gradient, formation conductivity, and injection temperature). The corresponding numerical solutions (approximately 1.2 million per heat exchanger design) are stored as multi-dimensional HDF5 datasets and can be queried at off-grid points using multi-dimensional linear interpolation. A Python script was developed to query this database and estimate time-dependent electricity generation using an organic Rankine cycle (for water) or direct turbine expansion cycle (for CO2) and perform a cost assessment. This document aims to give an overview of the HDF5 database file and highlights how to read, visualize, and query quantities of interest (e.g., levelized cost of electricity, levelized cost of heat) using the accompanying Python scripts. Details regarding the capital, operation, and maintenance and levelized cost calculation using the techno-economic analysis script are provided. This data submission will contain results from the Closed Loop Geothermal Working Group study that are within the public domain, including publications, simulation results, databases, and computer codes. GeoCLUSTER is a Python-based web application created using Dash, an open-source framework built on top of Flask that streamlines the building of data dashboards. GeoCLUSTER provides users with a collection of interactive methods for streamlining the exploration and visualization of an HDF5 dataset. The GeoCluster app and database are contained in the compressed file geocluster_vx.zip, where the "x" refers to the version number. For example, geocluster_v1.zip is Version 1 of the app. This zip file also contains installation instructions. **To use the GeoCLUSTER app in the cloud, click the link to "GeoCLUSTER on AWS" in the Resources section below. To use the GeoCLUSTER app locally, download the geocluster_vx.zip to your computer and uncompress this file. When uncompressed this file comprises two directories and the geocluster_installation.pdf file. The geo-data app contains the HDF5 database in condensed format, and the GeoCLUSTER directory contains the GeoCLUSTER app in the subdirectory dash_app, as app.py. The geocluster_installation.pdf file provides instructions on installing Python, the needed Python modules, and then executing the app.

15 GEOTHERMAL ENERGY↗

Thermal and Mechanical Energy Performance Analysis of Closed-loop Systems in Hot-Dry-Rock and Hot-Wet-Rock Reservoirs

To understand the potential and limitations for recovering thermal and mechanical energy from closed-loop geothermal systems a collaborative study is underway that will investigate an array of system configurations, working fluids, geothermal reservoir characteristics, operational periods, and heat transfer enhancements. Closed-loop geothermal systems are distinguished from hydrothermal or enhanced geothermal systems (EGS) in that the working fluid only circulates through drilled boreholes. Principal objectives of this study are to determine upper limits for thermal and mechanical energy recovery and optimal operational and configuration parameters for each scenario. Teams of scientists and engineers are applying a suite of numerical simulation and analytical tools to model the heat recovery from closed-loop geothermal systems, and then optimizing operational and configuration parameters to maximize the thermal and mechanical energy recovery. Results from the suite of numerical simulators and analytical tools, such as outlet and inlet states and temperature profiles in the geothermal reservoir over time are intercompared to increase confidence in the analysis. This paper documents the study findings for closed-loop systems in hot-dry-rock and hot-wet-rock reservoirs, where water is the working fluid. The characteristics of the hot-dry-rock reservoir were based on the U.S. Department of Energy's Utah Frontier Observatory for Research in Geothermal Energy (FORGE) site, near Milford Utah. Two objective functions are defined to optimize the operational and configuration parameters of the system, one each for the recovery of mechanical and thermal energy over the period of operation. For both objective functions, a surface plant thermal to mechanical energy conversion factor and an energy drilling cost is required. In keeping with the study objectives the surface plant conversion factor is determined from a second-law of thermodynamics analysis of a generic binary plant, and drilling costs are based on those from the Utah FORGE site and current national electrical costs.

closed-loop geothermal systems↗

Thermal and Mechanical Energy Performance Analysis of Closed-loop Systems in Hot-Dry-Rock and Hot-Wet-Rock Reservoirs

To understand the potential and limitations for recovering thermal and mechanical energy from closed-loop geothermal systems a collaborative study is underway that will investigate an array of system configurations, working fluids, geothermal reservoir characteristics, operational periods, and heat transfer enhancements. Closed-loop geothermal systems are distinguished from hydrothermal or enhanced geothermal systems (EGS) in that the working fluid only circulates through drilled boreholes. Principal objectives of this study are to determine upper limits for thermal and mechanical energy recovery and optimal operational and configuration parameters for each scenario. Teams of scientists and engineers are applying a suite of numerical simulation and analytical tools to model the heat recovery from closed-loop geothermal systems, and then optimizing operational and configuration parameters to maximize the thermal and mechanical energy recovery. Results from the suite of numerical simulators and analytical tools, such as outlet and inlet states and temperature profiles in the geothermal reservoir over time are intercompared to increase confidence in the analysis. This paper documents the study findings for closed-loop systems in hot-dry-rock and hot-wet-rock reservoirs, where water is the working fluid. The characteristics of the hot-dry-rock reservoir were based on the U.S. Department of Energy’s Utah Frontier Observatory for Research in Geothermal Energy (FORGE) site, near Milford Utah. Two objective functions are defined to optimize the operational and configuration parameters of the system, one each for the recovery of mechanical and thermal energy over the period of operation. For both objective functions, a surface plant thermal to mechanical energy conversion factor and an energy drilling cost is required. In keeping with the study objectives the surface plant conversion factor is determined from a second-law of thermodynamics analysis of a generic binary plant, and drilling costs are based on those from the Utah FORGE site and current national electrical costs.

Closed-loop geothermal systems, hot-dry-rock, hot-↗