Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “transient stability assessment”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

NRC Multiphysics Analysis Capability Deployment FY2020: Part 3

This report details progress and activities of Idaho National Laboratory (INL) on the Nuclear Regulatory Commission (NRC) project “Development and Modeling Sup- port for Advanced Non-Light Water Reactors.” The tasks completed for this report are: Task2c: Explicit modeling of pebble transient temperature response. In this simulation, the 400 MWth Pebble-Bed Modular Reactor (PBMR) design, PBMR- 400, experiences a 20-second power ramp from 100% to 150% power. This is followed by a similar reduction in the power back to 100%. Several multiscale pebble coupling approaches are tested with one pebble per mesh element in the active core region. The results show good conservation behavior and the stability of the coupling.; Extended scope part 1: An assessment of the computational efficiency of the Discontinuous Finite Element Method (DFEM) heat transfer solver shows good scalability. The DFEM solver is a factor of 4 more expensive in solution time than the Finite Element Method (FEM) solver for heat transfer problems due to the increased number of degrees of freedom. Nonetheless, the DFEM approach provides the user with the flexibility to model gap heat transfer problems.; Extended scope part 2: The GapHeatTransferInterfaceMaterial was improved to give the user increased flexibility with the modeling of heat transfer through gaps with the DFEM solver. A number of gap parameters can now be coupled both through functions and variables.; Extended scope part 3: Demonstration of how the gap width between hexagonal fuel cells can be calculated during a heat-up transient and used in the GapHeatTransferInterface model. A full-domain DFEM model with gap expansion is coupled to a SubApp that models the thermal expansion of the base plate. The results show the expected physical behavior, although have not been fully bench-marked at this point in time.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Stability analysis of a one-dimensional multiphysics model of a molten salt fast reactor

Reactor designs with a fast neutron spectrum have recently moved into the research focus for possible Generation IV reactor concepts - a representative of which is the molten salt fast reactor (MSFR). In order to assess the safety and reliability of this reactor concept, it is necessary to obtain knowledge of the system behaviour. An important part of this research concerns the dynamical stability of the MSFR. Research regarding the MSFR stability so far has either been using linearized models for stability criteria or only been examining certain transients at fixed parameter values. This work delivers a comprehensive stability analysis for a non-linearized MSFR model, and a wide range of values for all relevant parameters. For this purpose, a one-dimensional MSFR model was set up, taking neutron kinetics and thermal hydraulics in the form of a system of differential equations into account. The stability of this model was investigated by means of the numerical tool MATCONT, which was used to monitor the evolution of a so-called fixed-point solution, here referring to the steady state at operating conditions of the system, while system parameters got varied. The MATCONT analyses showed no loss of stability for any of the considered parameter variations and no solutions that might co-exist in parallel with the steady-state fixed-point solution. Therefore these results indicate a stable fixed point to which all solution transients converge, making the considered MSFR model insusceptible to deviations from the equilibrium. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

A Laplace-Domain Circuit Model for Fault and Stability Analysis Considering Unbalanced Topology

For systems subject to unbalanced faults, analytical model building for stability assessment is a challenging task. This letter presents a straightforward modeling approach. A generalized dynamic circuit representation is achieved by use of the Laplacian transform variable s . Here, we translate the voltage and current relationship at the fault location into the relationship of three subsystems. The final circuit model is an interconnected sequence network with impedances in the Laplace domain. This circuit can be directly converted from a steady-state sequence network. This modeling procedure is illustrated by an example case of an induction motor served by a grid through a series compensated line. Electromagnetic transient simulation results demonstrate that sub-synchronous oscillations can be mitigated when a single-line to ground fault is applied at the motor terminal. Stability analysis results based on the dynamic circuit corroborate the simulation results. What's more, the derived circuit effortlessly reveals why unbalance can enhance stability.

42 ENGINEERING↗

Controller Hardware-in-the-Loop Evaluation of a Microgrid Controller for a Microgrid System with Multiple Grid-Forming Inverters

This paper presents the laboratory evaluation of a commercial Microgrid Management System (MGMS) implemented in the real-world Bronzeville Microgrid which features a futuristic scenario with high renewable energy integration and the use of multiple Grid-Forming (GFM) inverters. The primary objective of the performance evaluation for the MGMS is to assess the MGMS's capability to dispatch GFM units, including a GFM PV unit and two GFM battery units, to maintain the system stability and ensure economic operation, thus guaranteeing the microgrid's resilience during prolonged outages and dynamic events. The laboratory controller hardware-in-the-loop provides realistic testing environment through detailed electromagnetic transient modeling of the microgrid system, hardware MGMS, and standard communication protocols (DNP3). The CHIL evaluation shows how the MGMS effectively manages the GFM inverters, highlighting its performance in maintaining stability, reliability, and survivability in a microgrid environment with a high penetration of renewable energy sources.

controller hardware-in-the-loop↗

Controller Hardware-in-the-Loop Evaluation of a Microgrid Controller for a Microgrid System with Multiple Grid-Forming Inverters: Preprint

This paper presents the laboratory evaluation of a commercial Microgrid Management System (MGMS) implemented in the real-world Bronzeville Microgrid which features a futuristic scenario with high renewable energy integration and the use of multiple Grid-Forming (GFM) inverters. The primary objective of the performance evaluation for the MGMS is to assess the MGMS's capability to dispatch GFM units, including a GFM PV unit and two GFM battery units, to maintain the system stability and ensure economic operation, thus guaranteeing the microgrid's resilience during prolonged outages and dynamic events. The laboratory controller hardware-in-the-loop provides realistic testing environment through detailed electromagnetic transient modeling of the microgrid system, hardware MGMS, and standard communication protocols (DNP3). The CHIL evaluation shows how the MGMS effectively manages the GFM inverters, highlighting its performance in maintaining stability, reliability, and survivability in a microgrid environment with a high penetration of renewable energy sources.

controller hardware-in-the-loop↗

Controller-Hardware-in-the-Loop Evaluation of a Microgrid Controller for a Microgrid System With Multiple Grid-Forming Inverters

This paper presents the laboratory evaluation of a commercial Microgrid Management System (MGMS) implemented in the real-world Bronzeville Microgrid which features a futuristic scenario with high renewable energy integration and the use of multiple Grid-Forming (GFM) inverters. The primary objective of the performance evaluation for the MGMS is to assess the MGMS's capability to dispatch GFM units, including a GFM PV unit and two GFM battery units, to maintain the system stability and ensure economic operation, thus guaranteeing the microgrid's resilience during prolonged outages and dynamic events. The laboratory controller hardware-in-the-loop provides realistic testing environment through detailed electromagnetic transient modeling of the microgrid system, hardware MGMS, and standard communication protocols (DNP3). This CHIL evaluation shows how the MGMS effectively manages the GFM inverters, highlighting its performance in maintaining stability, reliability, and survivability in a microgrid environment with a high penetration of renewable energy sources.

controller hardware-in-the-loop↗

From Event Data to Wind Power Plant DQ Admittance and Stability Risk Assessment

This paper presents a dynamic event data-based stability risk assessment method for power grids with high penetrations of inverter-based resources (IBRs). This method relies on obtaining the IBRs' DQ admittance through dynamic event data and computing the system's eigenvalues based on the admittance models. Two critical technologies are employed in this research, including time-domain and frequency-domain data fitting and dq-frame voltage and current signal derivation. The first technology is key to obtaining the s-domain expressions from the transient response data, and the s-domain DQ admittance model from the frequency-domain measurements. The second technology is key to obtaining the dq-frame voltage and current signals from either the three-phase instantaneous measurements or the phasor measurement unit (PMU) data. The method is illustrated using data generated from a Type-4 wind power plant modeled in PSCAD. This paper demonstrates the technical feasibility of the proposed approach.

17 WIND ENERGY↗

Adaptive Protection and Validated Models to Enable Deployment of High Penetrations of Solar PV (PV-MOD)

The availability and validation of various PV models in commercial tools differ, with some models not yet thoroughly validated for advanced inverter functionalities and reliable performance under weak system conditions. Many existing models do not fully incorporate new inverter control functions, which can affect system stability. The increasing deployment of solar PV and other inverter-based resources (IBRs), including distributed energy resources (DERs), is influencing the reliable operation of protection schemes in distribution systems and microgrids. Emerging adaptive protection schemes (APS) offer new opportunities for protecting these systems during varying configurations and DER operating conditions, though their demonstration and validation remain limited. Adaptive protection schemes face similar challenges, as they are typically designed for specific configurations. There is a growing need for tools and methodologies to streamline the deployment of adaptive protection for safe and reliable DER integration. The project main objective was to develop and validate high-fidelity generic models of solar PV facilities for stability, protection, EMT, and QSTS analyses. This objective was achieved, and these models can now be integrated into commercial software tools, enabling utilities, vendors, and developers to study high-penetration PV systems more confidently. The project also demonstrated advanced applications of these models, including the design and deployment of adaptive protection schemes in high-penetration field applications and microgrids, supporting grid safety and reliability. Several milestones were reached by the end of the project. A sophisticated inverter test plan was developed, and inverters representative of the North American marketplace were selected. EPRI and NREL tested various inverters, conforming to IEEE standards. Improvements were made to existing generic models of IBR units, IBR plants, and aggregated feeders for various analyses. The first generic electromagnetic transient (EMT) model for a solar PV plant was developed, conforming to IEEE Std 2800™-2022 and validated against laboratory measurements of a 2.2 MVA large-scale battery energy storage system (BESS) inverter. That model was then used to produce reference responses illustrating examples of validated and verified IBR plant models that pass or fail tests for technical minimum capability and performance as specified in the IEEE standard. The developed, tested, and validated generic models can be used for transmission planning, stability assessments, expansion planning, and evaluating potential future IBR interconnection requirements. They can also support interconnection screens and conformity assessments of IBR plants, including solar PV. The project significantly contributed to the ongoing standardization and model-based representation and verification of IBR responses. The project further addressed challenges of common distribution protection schemes with increasing deployment of DER by developing, validating, and demonstrating adaptive protection schemes (APS) that can improve the reliable and safe integration of DER into distribution systems. New APS were designed using improved DER models for three common distribution systems: a radial feeder, a meshed network, and a microgrid. Modeling and hardware-in-the-loop (HIL) testing of the APS were conducted, successfully showing their effectiveness and selectivity. Proof-of-concept field demonstration was achieved for two APS, i.e., one on a radial feeder and another one in a microgrid. Field demonstration could not be achieved for the APS on a meshed network, primarily due apprehension of one utility partner and also due to limited access to the protective algorithms in the network protectors. Guidelines developed from the lessons learned in the project lay out the general process followed in the design, installation, and commissioning of APS for various distribution systems. Distribution utility partners’ apprehension about field demonstration of the new APS were addressed—with varying success—by taking a stepped risk-management approach of modeling of a wide range of sensitivities first, performing in-depth proof-of-concept testing in the laboratory including HIL next, and finally deliberately implementing and commissioning the actual protection equipment and algorithms into parts of—or in parallel operation to—the three real distribution systems. Future work should include pilot projects that further show the acceptable performance of the developed APS before these schemes be rolled out more widely. Inclusion of both utility and original equipment manufacturers (OEMs) in future projects could increase chances of successful field demonstration. Despite challenges in achieving the field demonstration goal of the project for all three APS, the research significantly contributed to the innovation of adaptive protection solutions for scalable and reliable DER integration into distribution systems. This project significantly enhances the understanding of the impact of using appropriate inverter models on distribution and transmission (T&D) systems. By addressing the limitations of existing generic models, the project introduces high-fidelity models for stability, protection, electromagnetic transient (EMT), and quasi-static time series (QSTS) analyses. These models, integrated into commercial software tools, enable utilities, vendors, and developers to confidently study high-penetration PV systems. The project also demonstrates advanced applications, including adaptive protection schemes (APS) for distribution systems and microgrids, ensuring grid safety and reliability. The technical effectiveness and economic feasibility of the methods are evident through the development and validation of sophisticated inverter test plans and the selection of representative inverters. Testing by EPRI and NREL on retail, commercial, and utility-scale inverters, conforming to IEEE standards, underscores the robustness of the models. Improvements to existing generic models for various analyses further enhance their validity and applicability. The project also identifies gaps in common distribution protection schemes and designed new APS using improved DER models, demonstrating their effectiveness through modeling and hardware-in-the-loop (HIL) testing. The project’s benefits to the public are manifold. By advancing the standardization and model-based representation of IBR response, it supports transmission planning, stability assessments, and future IBR interconnection requirements. The generic models can facilitate better communication between transmission planners and developers, supporting expected IBR plant capability and performance. Additionally, the development of APS for radial feeders, meshed networks, and microgrids supports the integration of distributed energy resources (DERs) into distribution systems, enhancing grid reliability and safety. The project’s emphasis on thorough testing and simplicity in design ensures practical and scalable solutions for DER integration.

14 SOLAR ENERGY↗

Plasma catalysis: separating plasma and surface contributions for an Ar/N 2 /O 2 atmospheric discharge interacting with a Pt catalyst

Atmospheric pressure non-equilibrium plasmas can form nitrogen oxide (NO x ) compounds directly from nitrogen and oxygen without a catalyst, and at lower catalyst temperatures than would be possible without plasma. In this work, the oxidation of plasma-produced NO from an Ar/N 2 /O 2 non-equilibrium atmospheric-pressure plasma-jet (APPJ) over a platinum-on-alumina powder catalyst was investigated with in-situ infrared spectroscopy. Products downstream of the catalyst bed were analyzed along with catalyst surface species. The catalyst was exposed to plasma at both constant temperature and a cyclic temperature ramp in order to study long-lasting and transient surface changes. Primary incident reactive species to the catalyst were assessed to be NO and O 3 . Pt-Al 2 O 3 at 350 °C increased oxidation of NO relative to Al 2 O 3 or an empty chamber. The surface state of Pt-Al 2 O 3 evolves during plasma-effluent exposure and requires upwards of 20 min exposure for stabilization compared to Al 2 O 3 . Once stable surface conditions are achieved, thermal cycling reveals a repeatable hysteresis pattern in downstream products. At low temperature, oxygen and NO x accumulate on the catalyst surface and react at elevated temperatures to form NO 2 . Increasing plasma power and O 2 :N 2 ratio increases the hysteresis of the heating relative to the cooling curves in the pattern of NO 2 formation. The limitation on NO oxidation at high temperatures was assessed to be Pt-O which is depleted as the catalyst is heated. Once stored species have been depleted, NO oxidation rates are determined by incoming reactants. Two overlapping NO oxidation patterns are identified, one determined by surface reactants formed at low temperature, and the other by reactants arriving at the surface at high temperature. As a result, the plasma is responsible for providing the reactants to the catalyst surface, while the catalyst enables reaction at high temperature or storage at low temperature for subsequent reaction.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Underwater thermomagnetic generator for remote marine thermal energy harvesting and sensing

Thermomagnetic generators offer a promising approach for sustainable power generation in remote marine environments. Here, this study presents the design, thermal modeling, and experimental validation of a passively driven underwater thermomagnetic generator developed for powering ocean observation and monitoring sensors. The generator was evaluated under varying working fluids, thermal boundary conditions, and extended operation to assess real-world applicability. Two fluids, deionized water and silicone-based Thermal C5, were tested under simulated shallow- and deep-ocean conditions. Deionized water outperformed Thermal C5, especially in colder environments (~5°C), achieving a peak output of 2.7 mW due to larger temperature gradients and enhanced convective-evaporative heat transfer. Long-duration tests revealed a transient evaporation-condensation cycle that temporarily reduced rotor immersion and performance before stabilizing. The generator powered commercial marine sensors for over 6 h without external batteries, demonstrating the viability of compact, passively cooled thermomagnetic systems for autonomous, off-grid marine sensing.

13 HYDRO ENERGY↗

A comprehensive analysis of transient pressure and rate data from CO 2 storage projects in a depleted pinnacle reef oil field complex, Michigan, USA

Pressure and rate data are commonly recorded as part of a basic monitoring program in CCS projects. This paper discusses the application of multiple analytical techniques to interpret pressure and rate transient data from CO 2 injection and storage operations. The techniques of interest, i.e., injection-falloff analysis, injectivity/productivity index analysis and pressure pulse arrival time analysis, are commonly used in the oil and gas industry to assess reservoir properties, but not well known in the CCS literature (especially the last two). Injection-falloff analysis involves log-log pressure derivative plotting for the falloff data and history-matching of the entire injection-falloff sequence to determine permeability. In the injectivity/productivity index analysis, rate-normalized pressure buildup is plotted against material balance time or ratio of cumulative injection to injection rate to determine the injectivity index (ratio of injection rate to stabilized pressure buildup) which can be related to the permeability-thickness product. The arrival time analysis identifies the arrival of a pressure disturbance (~0.1 psi change from ambient) to determine the hydraulic diffusivity from which permeability can be estimated. The applicability of these techniques is demonstrated via illustrative examples from multiple wells in different pinnacle carbonate reefs undergoing CO 2 -EOR in Northern Michigan. The paper ends with a discussion of the relative merits of each interpretive technique, as well as recommendations that could be useful for other field projects.

42 ENGINEERING↗

Dynamic Validation of CNN-Based Surrogate Models for Inverter-Based Resources in Open-Source Solvers

Traditionally, distribution system planning has focused on steady-state analyses, with limited consideration of dynamic behavior. However, as large or medium-scale inverter-based resources (IBRs), particularly grid-following (GFL) inverters in commercial or industry buildings, become more prevalent, understanding their dynamic impact is essential for grid planning and operation. This article presents an innovative deep-learning (DL)-approach using convolutional neural networks technique to model the GFL inverters. Developed from real grid-tied commercial IBR transient data, these dynamic DL models overcome proprietary constraints by requiring minimal knowledge of internal converter physics while maintaining high accuracy and flexibility. To demonstrate their applicability, the models were incorporated into GridLAB-D, an open-source, three-phase distribution analysis tool. This integration enables dynamic simulations of large-scale distribution networks with high IBR penetration stability analysis. Rigorous testing and validation, aligned with industry standards, confirmed the reliability and efficiency of this approach, paving the way for enhanced planning and operational assessments of modern power systems.

Deep-learning↗

Impact of Integration Scheme on Performance of Anisotropic Plasticity Models

Given the prevalent role of metals in a variety of industries, schemes to integrate corresponding constitutive models in finite element applications have long been studied. A number of formulations have been developed to accomplish this task; each with their own advantages and costs. Often the focus has been on ensuring the accuracy and numerical stability of these algorithms to enable robust integration. While important, emphasis on these performance metrics may often come at the cost of computational expense potentially neglecting the needs of individual problems. In the current work, the performance of two of the most common integration methods for anisotropic plasticity -- the convex cutting plane (CCP) and closest point projection (CPP) -- across a variety of metrics is assessed; including accuracy and cost. A variety of problems are considered ranging from single elements to large representative simulations including both implicit quasistatic and explicit transient dynamic type responses. The relative performance of each scheme in the different instances is presented with an eye towards guidance on when the different algorithms may be beneficial.

36 MATERIALS SCIENCE↗

Diffusion in undoped and Cr-doped amorphous UO 2

UO 2 fuel pellets are often doped with chromium oxide to obtain favourable properties such as higher density, improved thermal stability, large grain sizes, improved pellet-clad interaction margins, and increased fission gas retention during transients. Chromium has a low solubility limit in UO 2 , with past experimental work reporting solubility limits ranging between 0.004 to 0.06 wt.% Cr. Due to its low solubility, segregation of Cr ions to the grain boundary may occur. Further, the complexity of these boundaries may be high as observed in other ceramics resulting in disordered or amorphous regions along the boundary, affecting a range of material and operational properties of the fuel pellet. To assess these disordered regions, in this work we study amorphous undoped and Cr doped UO 2 systems (containing 10–50 at.% Cr 3+ ) that have been modelled using classical molecular dynamics methods incorporating Cr 3+ into the well-used CRG potential library. Diffusion coefficients, pre-exponential factors, and activation energies for diffusion were computed for oxygen ions, assessing the impact of structure and extrinsic species on migration. Oxygen diffusion was observed to be much faster in the undoped amorphous system compared to its crystalline counterpart. Oxygen diffusion in doped systems decreased with increasing Cr concentration, highlighting the importance of additives to retain fission products and other migratory species.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Molecular Dynamics Simulations of Calcite Fracture in Water

Calcite (CaCO 3 ) is one of the most common minerals in geologic and engineered systems. It is often in contact with aqueous solutions, causing chemically assisted fracture that is critical to understanding the stability of subsurface systems and manmade structures. Calcite fracture was evaluated with reactive molecular dynamics simulations, including the impacts of crack tip geometry (notch), the presence of water, and surface hydroxyl groups. Chemo-mechanical weakening was assessed by comparing the loads where fracture began to propagate. Our analyses show that in the presence of a notch, the load at which crack growth begins is lower, compared to the effect of water or surface hydroxyls. Additionally, the breaking of two adjacent Ca–O bonds is the kinetic limitation for crack initiation, since transiently broken bonds can reform, not resulting in crack growth. In aqueous environments, fresh (not hydroxylated) calcite surfaces exhibited water strengthening. Manual addition of H + and/or OH – species on the (104) calcite surface resulted in chemo-mechanical weakening of calcite by 9%. Achieving full hydroxylation of the calcite surface was thermodynamically and kinetically limited, with only 0.17–0.01 OH/nm 2 surface hydroxylation observed on the (104) surface at the end of the simulations. In conclusion, the limited reactivity of pure water with the calcite surface restricts the chemo-mechanical effects and suggests that reactions between physiosorbed water and localized structural defects may be dominating the chemo-mechanical process in the studies where water weakening has been reported.

Calcite↗

EXERGETIC: De-Risking Next-Generation Resilient Geothermal Hybrids via At-Scale Evaluation Using Virtual Emulation Digital Twin Environment for Efficient Operation

The DOE-GTO-funded project, award number 5.1.2.12, entitled "EXERGETIC - De-risking Next Generation Resilient Geothermal Hybrids via at-Scale Evaluation Using a Virtual Emulation Digital Twin Environment for Efficient Operation," advances the solution to these challenges by developing and validating a geothermal co-emulation environment implemented at the National Laboratory of the Rockies (NLR)'s Advanced Research on Integrated Energy Systems (ARIES) platform. This framework enables the de-risking of next-generation geothermal and geothermal hybrid systems through high-fidelity modeling, real-time digital emulation, advanced control strategies, and techno-economic assessment. The project focused on geothermal hybrid configurations that integrate geothermal power plants with concentrated solar power and underground thermal energy storage, enabling enhanced efficiency, flexibility, and grid support capabilities. The main goal of this project was the development of a geothermal digital co-emulation environment to demonstrate the technical and economic value of geothermal hybrid systems and their contribution to grid stability and flexibility. The EXERGETIC framework combined physics-based models, controls, and real assets at ARIES, including digital real-time simulators (DRTS), a 20-MW-scale controllable grid interface (CGI), and a 2-MW conventional generator. Detailed transient models were developed for the key subsystems of a hybrid geothermal plant, including parabolic trough solar collectors, reservoir thermal energy storage (RTES), and a binary Organic Rankine Cycle (ORC) power plant. The ORC model explicitly captured thermal inertia and off-design operation and integrated control strategies to dynamically respond to electric load profiles. The models were validated against published experimental and numerical studies, demonstrating strong agreement and confirming the accuracy and robustness of the modeling approach. The resulting digital twin represents geothermal-solar-storage systems at multiple scales (1 MW to 100 MW) and enables realistic emulation of grid-connected operation. The control architecture allows the geothermal resource to provide stable baseload generation, while solar and stored thermal energy supply flexible, dispatchable support during periods of high demand or variable grid conditions. A key contribution of the EXERGETIC project is the demonstration that geothermal hybrid systems can be designed to be active grid assets rather than passive baseload generators. Using the ARIES platform, the digital twin was evaluated under multiple grid scenarios, including load following, voltage support at the distribution level, and frequency response at the transmission level. Results show that hybrid geothermal systems can respond effectively to dynamic grid conditions, providing inertia-like behavior, primary frequency support, and voltage regulation through coordinated control. In addition to the performance and grid services capability analysis of geothermal and hybrid geothermal systems, the EXERGETIC project also focused on scalability and techno-economic analysis of geothermal hybrid plants. In particular, for the scalability analysis, machine-learning (ML)-based surrogate models were trained using data generated from the geothermal digital twin under different grid-connected scenarios and plant capacities. These ML models demonstrated strong interpolation and extrapolation capabilities across plant sizes, accurately reproducing both steady-state and transient responses with very low errors. Regarding the techno-economic analysis, plant performance results were integrated with cost models for hybrid geothermal systems, and the levelized cost of electricity (LCOE) was used as the main economic metric to evaluate system performance across a range of system capacities, solar shares, solar multiples, and storage durations. Results indicate that economies of scale significantly reduce geothermal LCOE as plant capacity increases, with large-scale systems (25-100 MW) achieving substantially lower costs than small plants. Hybridization with solar thermal energy and storage further improves economic performance by increasing capacity utilization and enabling flexible dispatch. In addition, thermal storage plays a critical role in reducing LCOE by maximizing geothermal, solar, and stored energy resources. In summary, the results from this project demonstrate that geothermal hybrid systems represent a promising alternative for increasing the energy conversion efficiency of geothermal technologies, contributing to the preservation of geothermal resources, and supporting the transition of geothermal plants from traditional baseload resources into flexible, resilient, and cost-competitive energy conversion technologies.

15 GEOTHERMAL ENERGY↗

Characterization of Impedance and Stability for Doubly-Fed Induction Generator Based on Voltage-Modulated Direct Power Control

Voltage-modulated direct power control (VM-DPC) applied to the doubly-fed induction generator (DFIG) offers superior steady-state and transient performance but remains underexplored for suppressing wideband oscillations. Here, this article proposes a comprehensive impedance for the VM-DPC-based DFIG, analyzing its impedance characteristics and stability mechanisms compared with the DFIG based on vector-oriented control (VOC). The unified power transfer function is defined for DFIGs employing VM-DPC or VOC to ensure consistent comparison benchmarks. The comprehensive impedance of VM-DPC-based DFIG, incorporating mechanical and grid-side converter (GSC) dynamics, is derived using complex vector modeling in the αβ -frame. Furthermore, the influence of VM-DPC parameters and grid strength on the stability of grid-connected DFIG systems is assessed through eigenvalue trajectory analysis. Impedance analysis reveals the significant contributions of mechanical and GSC dynamics to DFIG impedance, as well as the narrower frequency range of negative resistance in the VM-DPC-based DFIG compared to the VOC-based DFIG. Stability analysis identifies the VM-DPC parameters of the rotor-side converter as dominant factors affecting system stability and confirms that the VM-DPC-based DFIG achieves better stability under weak grid conditions than its VOC-based counterpart. These findings are validated through simulations and experiments.

42 ENGINEERING↗

Unified Model of Current-Limiting Grid-Forming Inverters for Large-Signal Analysis

Grid-forming (GFM) inverters can hardly withstand any overloading. As such, GFM inverters need a current limiter in their control system to avoid hardware damage during overloading or grid disturbances. When the current limiter is engaged for inverter protection, however, it dynamically changes the inverter output impedance, which can significantly affect the system behavior against large disturbances. For example, when the current limiter curtails the output power, the primary controller of the GFM inverter-which generates the voltage and angle reference-is prone to losing synchronization with the grid. This can cause large-signal instability in the network. This paper presents a unified GFM current-limiter model to gain a deeper understanding of the impact of the GFM inverter current limiting on large-signal instability and other system behaviors. The unified model captures several well-known current limiters for GFM inverters, and it reveals their large-signal equivalence characterized by the limiter angle. We use the unified model to present in-depth insights into the driving forces that cause large-signal instability in GFM inverter-driven grids. Further, this paper illustrates that the unified model can be used as a tool for assessing the system-level impacts of various GFM current-limiter designs during grid disturbances. Using numerical, analytical, electromagnetic transient models, and a hardware setup, the validity of the unified model is evaluated.

24 POWER TRANSMISSION AND DISTRIBUTION↗