A Time-Domain Protection Approach for AC Transmission Systems With Grid-Forming Resources

Ac transmission protection must reliably detect, classify, and locate short-circuit faults from voltage and current measurements. At present, these functionalities, which have been classically engineered using phasors approaches, are being challenged by the dynamic behavior and fault-current limits of converter-based generation. This paper tackles these challenges by engineering a time-domain protection approach that leverages the classical Bergeron model in a new manner. Low- and high-impedance faults are detected and classified by ascertaining how well line voltage and current measurements match the Bergeron equations. Faults are located by posing a novel one-variable optimization problem, whereas voltage and current waveforms at the fault location are estimated by unveiling rigorous relationships. The proposed elements are secure against external faults, measurement errors, and variation of line parameters and sampling time. Furthermore, these advances are tested via electromagnetic transient simulations and are significant to satisfy IEEE and North American Electric Reliability Corporation requirements.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Robust Disturbance Rejection Rotor Current Control of Doubly-Fed Induction Generators

This article proposes a robust transient disturbance rejection current controller (TDRCC) to improve the transient performance of doubly-fed induction generators (DFIGs) in wind turbines during grid disturbances, such as short circuits. Here, the proposed robust TDRCC replaces the proportional-integral-derivative (PID) current controllers conventionally used in the vector control scheme of the DFIG rotor side converter (RSC). The TDRCC estimates the transient disturbances caused by grid faults or other external disturbances and provides compensation to the DFIG rotor voltage in the current control loops of the RSC to improve the robustness of the controller to disturbance. A sliding-mode current controller (SMCC) is also designed to highlight the transient performance improvement of the DFIG using the TDRCC over the state-of-the-art control methods during grid short circuit faults. Simulation studies are conducted in PSCAD/EMTDC for a 3.6-MW DFIG wind turbine with the proposed TDRCC, the conventional PI controller, and the SMCC, respectively during the most severe balanced three-phase grid short circuit fault specified by the U.S. grid code as well as an unbalance single-phase grid short circuit fault. Hardware experiments are conducted on a 200-W DFIG wind turbine emulator with the three different controllers for the same three-phase short circuit fault. Simulation and hardware experiment results show that the TDRCC reduces the peak rotor current significantly when compared with the PI and SMCC controlled DFIG system and, therefore, would help prolong the lifespan of the DFIG's power electronics and reduce maintenance costs.

42 ENGINEERING↗

Study the Protection Improvements for a Weak Grid Area With High IBRs

NLR is collaborating with Florida Power & Light (FPL) and GE to investigate power system stability and protection reliability challenges in a weak-grid region with high penetration of inverter-based resources (IBRs). This presentation will primarily focus on the protection aspects of the study. We will share key insights from this real-world project, including best practices for developing high-fidelity fault study models, establishing a controller-hardware-in-the-loop (CHIL) platform for testing physical relays, identifying system-level protection challenges, and designing enhanced protection schemes to address those issues. Through this discussion, the audience will gain practical understanding of protection studies in IBR-dominated systems, the emerging challenges associated with reduced fault current and altered transient behavior, and effective mitigation strategies. In particular, we will highlight the critical importance of IBR compliance with IEEE 2800-2022 to ensure dependable and secure protection relay operation in modern transmission systems.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Medium Voltage Testbed for Comparing Advanced Power Line Sensors vs. Transformers with Electrical Grid Events

Electrical utilities have relied upon potential transformers (PTs) and current transformers (CTs) for very accurate metering and to provide reliable signals for protective relays. These devices measure phase voltages and currents and are commissioned by electrical engineers. PTs/CTs can detect and react to various electrical anomalies that could adversely affect electrical grid operations. Less expensive alternative sensing technologies offer the possibility of wider deployment, particularly in grids that employ distributed energy resources. In this work, the performance of an advanced medium-voltage sensor is compared with that of a reference PT and a CT and experimentally evaluated for different power grid scenarios on an advanced outdoor power line sensor testbed at the U.S. Department of Energy’s Oak Ridge National Laboratory. The sensor is based on a capacitive divider for voltage monitoring and a Rogowski coil with an integrator for current monitoring. This study simulated a power grid model based on a utility circuit at the Riverside EPB of Chattanooga. The simulation circuit was created with MATLAB/Simulink software and was integrated into an RT-LAB project to run with the OP4510 real-time simulator at the OPLST. During the tests, the real-time simulations were run for 40 s, and the signal to record the test event with the power meter was set at 30 s for the event-trigger circuit. The advanced outdoor power line sensor testbed has a real-time simulator that is used to generate transient scenarios (e.g., electrical faults, capacitor bank operation, and service restoration), while the analog signals are recorded by the same high-resolution power meter. The behaviors of analog signals, harmonic components, total harmonic distortion, and crest factors are assessed for this power line sensor and compared with those of the reference PT/CT because of the absence of testing standards for advanced outdoor power line sensors. The results showed that this OPLS technology responded identically to the PT and CT under all conditions.

Piesciorovsky, Emilio [ORNL]↗

T-Type Modular DC Circuit Breaker (T-Breaker) for Future DC Networks

The developed T-Type Modular DC Circuit Breaker (T-Breaker) technology offers an all-in-one solution to challenges in DC networks. This includes swift fault detection and protection, power transient stability, and power quality improvement, achieved through the utilization of wide bandgap (WBG) power semiconductors and energy storage devices. The T-Breaker not only facilitates rapid fault current detection and interruption but also implements fault current limiting through active insertion of storage devices or by operating WBG devices in the saturation region. Additionally, with the assistance of energy storage devices, potential overvoltage issues on power devices induced by control signal misalignment can be mitigated. The T-Breaker can be regulated to perform shunt current injection/absorption using the vertical arm and series voltage insertion via the horizontal arm, thereby enhancing DC system stability during voltage or load power fluctuation transients. The OSU team and Raytheon team actively worked together on designing, fabricating, assembling, and testing of two T-Breaker prototypes. The first prototype is rated at 1 kV, 500 A with half-bridge (unipolar) structure to validate the T-Breaker concept. The second prototype is rated at 20 kV, 50 A with full-bridge (bipolar) topology which can reach an efficiency of 99.977%, realize a power density of 60.2 MW/m3, and eliminate the 500-A fault current with a fault response time of around 20 µs. The prototypes show great feasibility of adopting this technology in multiple applications including electrified aircraft, super charging stations, data centers, etc.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Analysis of a Disturbance Event with Inverter-Based Resources Using EMT Simulations

Increasing penetration of inverter-based resources (IBRs) necessitates newer methods of planning and analysis of disturbances. The existing phasor-domain transient stability (TS) analysis may not capture the dynamics of IBRs during fault events. Here, in this paper, electromagnetic transient (EMT) simulations using high-fidelity detailed model of power grid and one of the affected photovoltaic (PV) plants during the Angeles Forest disturbance in 2018 are performed. In these simulations, the processes to develop EMT models of power grid from traditional phasor-domain TS data and PV plant from collected data are described. Thereafter, using these simulations, the response of the PV plant during the fault event in 2018 is replicated and a sensitivity analysis is performed. The sensitivity analysis consists of making changes to the components within the PV plant and in the power grid to evaluate the impact they have on the response observed by the PV plant during the fault event. This analysis provides an understanding of the components that impact the operation of a PV plant during fault events and provide guidance to system planners on the studies that need to be performed to maintain a reliable power grid as new IBR plants are integrated.

42 ENGINEERING↗

Direct current momentary circuit interrupter

A momentary circuit interrupter in series connection with a mechanical switch to provide protection against short circuit faults in a DC power circuit. The momentary circuit interrupter injects a transient voltage pulse via a pulse transformer to reduce a DC fault current to near zero in a DC circuit branch, thus allowing the mechanical switch to disconnect the faulty branch under a near zero-current condition. The power electronic circuit on the primary side of the transformer controls the discharge of a plurality of pre-charged capacitors to generate the transient voltage pulse during the fault interruption process, but otherwise does not incur any power loss during normal operation. The secondary winding of the pulse transformer conducts the main DC current, and is highly conductive to minimize the conduction power loss. The invention provides ultrafast response to a short circuit fault (even faster than solid-state circuit breakers and much faster than hybrid circuit breakers), significantly reduced overcurrent stress in the power system, and/or ultralow conduction power losses.

Shen, Zheng John↗

Improving Subsurface Stress Characterization for Carbon Dioxide Storage Projects

Researchers at New Mexico Tech, Los Alamos National Laboratory (LANL), Sandia National Laboratory (SNL), and other collaborators are developing a methodology to improve characterization of stress in the subsurface by means of a model-based inversion of reservoir engineering data, time lapse seismic measurements, and microseismicity. Historically, various geophysical techniques have been used in efforts to understand the state of stress in the subsurface through direct and indirect imaging of stress sensitive features (faults and fractures) and observations of transient stress related observations (time variant elastic moduli and microseismicity). Standard direct and indirect techniques for seismic fault and fracture imaging suffer from detectability limits due to reliance on high data quality and multiplicity. Variations in effective elastic properties from inversion of high quality seismic (Vertical Seismic Profile (VSP)) data may be used to infer stress near the wellbore through integration with independent experimental characterization of the stress-velocity relationship. Given a sufficiently robust observation network, microseismic emissions may be inverted to characterize focal mechanisms which, together with supporting assumptions and constraints, inform estimates of in-situ stress. While each of these techniques contributes in part to the characterization of stress within limited spatial and temporal domains, no one method provides an unambiguous stress measurement or a predictive capability over a site scale spatial extent. Challenges associated with solution non-uniqueness, measurement ambiguity, and irregular sampling may be greatly minimized through combination of one or more of independent measurements within a common framework in which realistic geological, hydrodynamic, geomechanical, and seismological constituent process models may act as constraints.

02 PETROLEUM↗

SAS4A/SASSYS-1 Commercial Grade Dedication Example Report for a Generic Sodium Pool-Type Fast Reactor Application

In the U.S., a key component of the commercialization of advanced reactors is completion of a license application, which must ultimately be approved by the Nuclear Regulatory Commission (NRC). The approval of the license application by the NRC is contingent on satisfactory demonstration of the design basis and the response of the advanced reactor design to transient and accident scenarios using accepted codes and methods. This report describes the qualification and dedication requirements that the advanced reactor safety analysis system software SAS4A/SASSYS-1 are expected to need to fulfill to be used for sodium-cooled pool-type fast reactor licensing. The qualification and dedication requirements are identified through performance critical characteristics and evaluation model acceptance criteria representative of the advanced reactor design considered for licensing. This document captures, additionally, the verification process developed to demonstrate that the software fulfills the qualification and dedication requirements for a generic sodium-cooled pool-type fast reactor as part of the commercial grade dedication process. Like most software that has primarily existed in the research and development space, the most significant challenge facing SAS4A/SASSYS-1 for use in a licensing framework is the availability of a documentation basis describing the code pedigree. SAS4A/SASSYS-1 has been used for licensing of the fast flux test facility (FFTF) and the JOYO sodium-cooled fast reactor in Japan, as well as the design of the CRBR Plant. However, the historical verification and validation (V&V) activities supporting SAS4A/SASSYS-1 development do not align with modern software quality assurance (SQA) and V&V requirements. Two approaches to use of SAS4A/SASSYS-1 in a commercial licensing framework have been identified: commercial-grade dedication (CGD) and software qualification. The methods and requirements prescribed in the ASME NQA-1-2008/2009 Standard and Regulatory Guide 1.203 on the evaluation model development and assessment process (EMDAP) have been used as guidance to define the CGD and qualification processes, respectively. A qualification and dedication requirements matrix has been developed which utilizes fundamental software verification. In this process, software verification is defined as a software quality process aimed at defining software requirement specifications, developing software design documentation, and performing and documenting acceptance testing of the code against requirements. A key element of software qualification and dedication includes determination of software acceptance with respect to critical characteristics relevant to the functional requirements of the software. To assist with identification of cross-cutting transient phenomena and functional requirements, domestic SFR vendor designs have been reviewed to identify a reference SFR design. For this report, the reference design is defined as a pool-type reactor with metal alloy fuel, a liquid-metal intermediate heat transport system, and passive decay heat rejection systems. Given this reference, a series of high-level cross-cutting phenomena was identified for a general class of single-fault undercooling or reactivity insertion transients that scopes the design basis space, with the goal of assisting with prioritization of documentation development efforts for key transient models in SAS: 1) Reactivity feedback response prior to scram; 2) System-wide thermal inertia; 3) Transition in natural circulation flow regime in heat removal systems; 4) Decay heat generation; 5) Steady-state fuel characterization; 5) Clad/fuel behavior at elevated temperatures; 6) Point kinetics and decay heat; 7) Pump coastdown behavior; 8) Core flow redistribution in loss of forced convection; 9) Pool stratification. As a demonstration of CGD of SAS4A/SASSYS-1 for a sodium pool reactor, a software qualification and dedication gap analysis as it relates to code documentation has been performed. This effort leverages the framework established as part of the SAS4A/SASSYS-1 SQA Program. This CGD demonstration provides a framework that vendors can build upon to demonstrate the applicability of the SAS4A/SASSYS-1 software for licensing a sodium-cooled pool-type fast reactor.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Voltage Service Limits Smart Contract Using Distributed Ledger Technology for Electrical Utility Grid with Customer-Owned Generator

Modern electrical grids face growing stability risks from customer-owned generators, especially at points of common couplings (PCCs). Disruptive behavior from power-electronic sources can cause protective relays to isolate problematic generators, making measurement integrity critical. This article presents a distributed ledger technology (DLT) approach that uses smart contracts to evaluate PCC voltage measurements and trigger backup breaker operations. The approach is framed as a verifiable, multi-organization attestation and audit layer, not as a real-time control security mechanism. In the proposed architecture, voltage measurements from a hardware protective relay are anchored on a DLT through the Cyber Grid Guard (CGG) system for attestation by both the grid utility and customer-owned generator. A Voltage Service Limits (VSLs) smart contract evaluates the on-chain measurements against allowable phase-voltage limits derived from the ANSI C84.1 standard. The framework is validated in a hardware-relay-in-the-loop test bed under sustained-undervoltage, sustained-overvoltage, and transient line-to-line fault scenarios. The results show that the VSL smart contract can process these measurements and issue backup breaker actions consistent with the defined service-limit criteria, demonstrating the DLT potential as a verifiable audit layer at the PCC that complements primary protection.

cyber security↗

Improved Beam Loss Accounting with Fast Data Acquisition (DAQ) Chassis

Identifying the source of beam loss events in the CE-BAF accelerator can be a challenging task. However, with our new prototype system, this task becomes more effi-cient. The system, developed in the fall of 2022, utilizes a dispersive beam position monitor (BPM) and the exist-ing switched electrode electronics BPM hardware. Previ-ously a commercial off-the-shelf data acquisition (DAQ) system was employed to capture BPM wire signals at a sample rate of 20 kS/s. The fast shutdown signal triggered the system, which disables the beam at the injector. Analysis of beam position and energy variation before a beam loss event was used to determine if the beam loss event was associated with an energy transient. The proto-type system, implemented using National Instruments hardware and LabVIEW® software, relied on a software trigger. Manual post-processing was required to ascertain whether the fault was due to an un-tripped cavity with a gradient or phase transient. This work focuses on deploying a Fast DAQ Chassis to monitor BPM hardware in real time and during beam loss events. This system was originally developed and in-stalled in CEBAF to monitor the time-domain RF control signals in the legacy analog RF systems. This technology was leveraged to also monitor BPM signals. As the new system employs a hardware trigger, developing tools to automatically identify faults linked to energy transients unrelated to cavity faults will be straightforward. This paper will discuss the project's initial updates, underlin-ing the crucial role of each member of our team in this achievement

Tiskumara, J.↗

A propagation-based fault detection and discrimination method and the optimization of sensor deployment

Industrial processes can be affected by faults having a serious impact on operation when not promptly detected and diagnosed. Here in this paper, a propagation-based fault detection and discrimination(PFDD) method is proposed to develop a strategy for fault diagnosis while in the design phase of a system. The PFDD method constructs the system model using the Integrated System Fault Analysis(ISFA) technique. Based on the system model, the propagation of hardware and software faults are simulated qualitatively. Given the results of the simulation, the process by which a fault propagates can be characterized using the qualitative features of system variables including the deviation of the system variables from their expected values, the variation of the system variables over time, and the order in which each variable is influenced during the propagation of the fault. The strategy by which a fault can be detected and discriminated is defined using those features. The PFDD method supports the detection and discrimination of faults in both steady states and transient states. Based on the PFDD method, the optimization of sensor deployment in a system is discussed. A brute force algorithm is developed to examine the system’s capability at diagnosing faults and the cost of sensor deployment for all possible configurations of sensors. The optimal sensor deployment strategy can be derived accordingly. However, the brute force method is only applicable to small-scale systems due to its high computational cost. A genetic algorithm is used to optimize sensor deployment in large-scale systems. The PFDD and sensor deployment optimization methods are applied to the Experimental Breeder Reactor II (EBR-II) for verification.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Transient Stability Study of IEEE 2800-2022 Standard Negative-Sequence-Current Compliant GFM IBRs

The primary function of grid-forming (GFM) inverter-based resources (IBRs) is to maintain voltage and fre- quency/phase angle stability; however, during unbalanced grid faults, IEEE Std. 2800-2022 requires IBRs to inject both positive- and negative-sequence reactive current. Enforcing compliance with this standard could compromise the stability of GFM IBRs under such fault conditions. This paper presents a preliminary transient stability study focused on the power angle stability of GFM IBRs operating in compliance with IEEE Std. 2800 during unbalanced faults. The goal is to assess potential stability issues associated with the standard's current injection requirements under fault ride-through conditions. The results show that injecting positive-sequence current with d-axis priority during unbalanced faults better preserves the power angle stability than the q-axis priority while still enabling negative-sequence current injection. These findings suggest that, to ensure stability, GFM IBRs might need to partially comply with IEEE Std. 2800 by prioritizing positive-sequence current injection along the d-axis.

14 SOLAR ENERGY↗

Dynamic Human-in-the-Loop Simulated Nuclear Power Plant Thermal Dispatch System Demonstration and Evaluation Study

An Idaho National Laboratory research team performed a human-in-the-loop study with two formerly licensed retired operators to evaluate thermal power dispatch operations supported by the modified GSE Systems GPWR plant simulator. Virtual representations of the analog control panels were presented on touch-screen bays configured to mimic the control room layout in the newly renovated Human Systems Simulation Laboratory. The operators performed 15 scenarios covering normal evolutions to transition the plant from full turbine operation to joint turbine and thermal power dispatch operations in addition to transient response scenarios induced with simulated faults to evaluate the impact of thermal power dispatch system on operator and plant responses. A prototype human-system interface (HSI) was developed and displayed in tandem with the virtual analog panels to support the operators executing the procedurally drive evolutions and transient responses. An interdisciplinary team of operations experts, nuclear engineers, and human factors experts observed the operators performing the scenarios to evaluate the operations. Only a preliminary analysis of the results has been performed. The full analysis will be shared in a milestone report scheduled for release at the end of September; however, some high-level conclusions were readily available. Two high level findings for the system design were captured in the study. The manual control supported by the HSI to transition from standard operations to thermal power dispatch operation imposed a considerable amount of workload on the operators due to tedious manual valve manipulations and system monitoring required to verify their intended effect. An additional operator would be required in the control room to support the daily evolution. Automatic control for the transition was deemed a requirement for plant adoption without imposing additional staffing costs. The second finding was the necessity for an automatic thermal power dispatch system trip isolation function linked to a turbine and reactor trip signal. The operators completed scenarios with automatic isolation functionality and manually required actuation of the thermal power dispatch system. The operator response was sufficiently slower in the manual trip condition, such that operators were unable to manually actuate key post trip safety functions an indicate a degraded control capability that should be avoided. With an automatic trip signal little to no impact of the thermal power dispatch system was identified on the primary plant response and therefore the system could be readily and safely adopted. Together these two findings represent the need to support the adoption of thermal power dispatch capability into existing operations by leveraging automation to augment any additional operator tasking required to control and monitor an additional system beyond existing operations.

99 GENERAL AND MISCELLANEOUS↗

Equivalent-Circuit Models for Grid-Forming Inverters under Unbalanced Steady-State Operating Conditions: Preprint

Positive- and negative-sequence equivalent-circuit models are put forth to capture the operation of grid-forming (GFM) inverters in unbalanced steady-state operating conditions acknowledging the impact of current limiting. The particular control architecture examined adopts droop control (for primary control), nested inner-current and outer-voltage control (in the stationary reference frame), and it is adaptable to two different types of current limiting (current-reference saturation and virtual-impedance limiting). We anticipate the proposed models to be of interest in modeling, analysis, and simulation of GFM inverters in unbalanced settings that may arise, e.g., in the face of faults. Validation of the equivalent-circuit models is pursued via comparison with full-order electromagnetic-transient (EMT) simulations for representative balanced and unbalanced faults.

equivalent-circuit models↗

Grid-Connected Modular Soft-Switching Solid State Transformers (M-S4T)

The objective of this project is to develop and verify the concept of a flexible and modular soft-switching solid-state transformer (M-S4T) for direct grid-connected applications. The ability to directly connect power electronics converters to the medium voltage grid (4 kV – 13 kV), and to potentially replace the passive and bulky, but ubiquitous 60 hertz service transformer in the 25 kVA to 100 kVA range, with a more flexible and controllable device, has been regarded as the ‘holy grail’ in grid control. However, this has proven to be extremely difficult. This project has developed the solutions to several key challenges of the direct grid-connected power electronics and realized a 7.2 kV M-S4T prototype. First, a protection method to protect the M-S4T from the high voltages (110 kV for the 13 kV system) that occur on the grid due to transients and lightning strikes have been developed and experimentally verified. Second, the realization and the operation of the M-S4T based on high-voltage SiC devices (>3.3 kV) and a medium-frequency medium-voltage low-leakage transformer in a single-stage solid-state transformer with zero-voltage switching, low dv/dt, and low electromagnetic interference has been successfully demonstrated up to 7.5 kV peak. Third, an oil-cooling system and stable communication and distributed control system for converter module voltage sharing have been developed and experimentally verified. The developed M-S4T has realized a modular universal high-performance power conversion system. This conversion system is scalable to different voltage and power levels and adaptable to four-quadrant bidirectional operation. Moreover, the use of passive cooling techniques meets the equipment life requirements, and the lightning protection scheme fulfills the basic insulation level specifications for direct grid connection. Such power conversion system opens up near-term opportunities, including energy storage, solar PV, or electric vehicle charging with significant cost and footprint savings. In the longer term, the possibility of replacing the utility distribution transformer with an M-S4T will be transformative for future distribution grids with a compact footprint and full controllability to enable high renewable energy and storage penetration. In addition to the main project, this report expands on the Plus-Up projected including as part of the main award. This project developed and demonstrated the technology for autonomous collaborative inverters that can be connected in an ad hoc manner to the grid. The aim of the project was to: (1) evaluate the existing techniques for grid-connected inverters and find their limitations; (2) develop detailed requirements for grid-connected inverters in the modern grid with millions of active nodes; (3) design a unified control strategy that brings more autonomy and intelligence to grid-connected inverters, and addresses parts of the issues with the existing techniques. The proposed technique, called UniCon, enables inverters to 1) connect/disconnect to/from the grid in an ad hoc manner; (2) work based on local sensing. Slow communication could be used for a more optimized behavior; (3) work automatically in both grid-forming/grid-following mode; (4) handle large disturbances, e.g., big load step and fault, in an oscillation-free manner; (5) work collaboratively with other inverters in steady-state and during transients. UniCon can be implemented in the middle-level control; hence it is agnostic to the vendor and to the implementation of the inner voltage/current and protection loops. Furthermore, a new synchronization scheme, based on deep learning, was developed that can extract the grid voltage phase and amplitude in a stable manner. The method is cheap to implement can improve the dynamic performance of the grid-connected inverters during fast transients, e.g., fault. The proposed control scheme was validated by (1) MATLAB/Simulink; (2) hardware-in-the-loop results, and; (3) experimental results using three inverters that form a microgrid in a down-scaled feeder. Lastly, both the M-S4T and UniCon have achieved promising tangible paths to markets. In the case of the M-S4T, the underlying technology — the Soft Switching Solid State Transformer (S4T) developed at the Georgia Tech Center for Distributed Energy (GT-CDE) has been licensed by GridBlock from the Georgia Tech Research Corporation, and GridBlock has been working with manufacturing partner Jabil (one of the largest US-based contract manufacturers) and system integrator Power Secure (largest deployer of microgrids in the US with 4.7 GW under management), to meet the strong initial demand. Similarly, GridBlock has an exclusive license to the UniCon technology, developed under this award by GT-CDE. The UniCon provides an intermediate control layer that enables the implementation of the higher-level ‘transactive’ control commands for the system. The architecture of the system - slow communications with the cloud for system optimization and setpoints, and the use of locally measured quantities for real-time control, provide a very robust and secure way of implementing a real-time must-run grid that is also secure and stable. This is a brand-new functionality that is critical for the future grid and key to GridBlock’s business model.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Numerical Simulations of Geologic Storage Reservoir Management to Support Risk Mitigation Evaluation

This report provides a detailed description of a set of numerical simulations that represent reservoir behavior over time in response to different operational decision scenarios for detection of potential leakage and reduction or avoidance of leakage impact at a hypothetical geological carbon storage (GCS) site. These simulations serve as the basis for a series of GCS leakage risk forecasts that are to be developed using the National Risk Assessment Partnership’s Open-Source Integrated Assessment Model (NRAP-Open-IAM), and a demonstration of a simple decision support workflow for evaluation of mitigation strategies based on results of those system model forecasts. This risk assessment and decision support study is forthcoming. Four injection scenarios were considered: a constant rate carbon dioxide (CO 2 ) injection case (base case), a case with CO 2 injection rate adjustment, a case with early termination of injection operations, and a case with brine extraction. CO 2 injection operations were controlled to ensure that the pressure transient remains below the defined manageable reservoir fracture pressure, with consideration shown to hypothetical locations within the modeled spatial domain where the overburden was weaker and lower transient pressure increases were allowable. Additionally, a brine extraction alternative was considered as a reservoir management and risk mitigation option to reduce reservoir pressure, steer the plume away from any hypothetical geohazard such as fault as needed, and enhance storage capacity. Such operational actions contribute to risk management overtime. This study explores the potential utility of reservoir management for risk reduction at GCS sites. This study shows that the injection design may modify the time to CO 2 breakthrough at a legacy well; in particular, these results show that brine extraction can add value for mitigating risk both by delaying leakage and reducing pressure build-up. For the scenario considered, both pressure plots and pressure distributions demonstrate that pressure build-up was decreased by 3% with brine extraction. Additionally, extraction of brine afforded enhancement of CO 2 storage capacity by 5% compared to the base case. These findings suggest that brine extraction has substantial potential to steer the risk-related reservoir effects away from known geohazards (e.g., faults and legacy wells) by conducting pressure transient effects and CO 2 plume movement toward the production well. Injection rate adjustment scenarios considered in this study show potential value for managing both reservoir pressure transients and CO 2 plume behavior. Operational actions for reducing injection and/or early termination of injection (as compared to the base case), however, require careful design; tailoring both the extent and timing of injection rate adjustment over the injection and post-injection operational period must be thoroughly planned to balance maximizing storage and minimizing subsurface environmental risk. The study also gives preliminary consideration to the effectiveness that monitoring strategy may play in providing useful information to inform reservoir management decisions for risk reduction. Two types of monitoring were considered: 1) pressure build-up or pressure transient; and 2) potential leakage detection from a CO 2 mass or plume. Four hypothetical legacy wells, two plugged and two abandoned, were placed in the model domain. Monitoring along these wells was measured over time in individual stacked reservoir formations and shale formations to support risk mitigation decisions, especially operational decisions that assisted in risk reduction. These simulations will serve as the basis for a series of GCS leakage risk forecasts that are to be developed using NRAP’s Open-IAM, and demonstration of a simple decision support workflow for comparative assessment of mitigation alternatives based on results of those system model forecasts. This risk assessment and decision support study is forthcoming.

54 ENVIRONMENTAL SCIENCES↗

Modeling CO 2 flow through faulted/fractured reservoirs using tEDFM in corner-point grids

The interest in underground CO 2 storage has increased significantly over the last decade because of the rising concern about global warming due to the growing levels of greenhouse gases in the atmosphere. Considering that CO 2 accounts for 80% of these greenhouse gases, carbon capture, utilization, and storage (CCUS) is regarded as one of the most direct approaches to achieving the net zero carbon target. Although CO 2 storage in deep saline aquifers and depleted gas reservoirs has been studied extensively, most studies use commercial simulators that model faults/fractures by simply modifying the transmissibility in the direction perpendicular to the fault surfaces. Here, this work shows that this simplistic approach ignores the accelerated flow in the directions parallel to the fault plane, leading to significantly higher leakage along the fault surface. To accurately model the flow of CO 2 in faulted reservoirs, we present the first transient embedded discrete fracture model for corner-point grids (tEDFM-CPG). By comparing the results of the tEDFM-CPG to high-resolution reference solutions, we show that this approach is accurate and efficient at predicting CO 2 flow in faulted/fractured reservoirs. Finally, this work presents the use of mixed reality (MR) to efficiently observe CO 2 gas migration in the interior of these corner-point grid systems.

25 ENERGY STORAGE↗