Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “transient event”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Single Event Transients in Linear Integrated Circuits

On November 5, 2001, a processor reset occurred on board the Microwave Anisotropy Probe (MAP), a NASA mission to measure the anisotropy of the microwave radiation left over from the Big Bang. The reset caused the spacecraft to enter a safehold mode from which it took several days to recover. Were that to happen regularly, the entire mission would be compromised, so it was important to find the cause of the reset and, if possible, to mitigate it. NASA assembled a team of engineers that included experts in radiation effects to tackle the problem. The first clue was the observation that the processor reset occurred during a solar event characterized by large increases in the proton and heavy ion fluxes emitted by the sun. To the radiation effects engineers on the team, this strongly suggested that particle radiation might be the culprit, particularly when it was discovered that the reset circuit contained three voltage comparators (LM139). Previous testing revealed that large voltage transients, or glitches appeared at the output of the LM139 when it was exposed to a beam of heavy ions [NI96]. The function of the reset circuit was to monitor the supply voltage and to issue a reset command to the processor should the voltage fall below a reference of 2.5 V [PO02]. Eventually, the team of engineers concluded that ionizing particle radiation from the solar event produced a negative voltage transient on the output of one of the LM139s sufficiently large to reset the processor on MAP. Fortunately, as of the end of 2004, only two such resets have occurred. The reset on MAP was not the first malfunction on a spacecraft attributed to a transient. That occurred shortly after the launch of NASA s TOPEX/Poseidon satellite in 1992. It was suspected, and later confirmed, that an anomaly in the Earth Sensor was caused by a transient in an operational amplifier (OP-15) [KO93]. Over the next few years, problems on TDRS, CASSINI, [PR02] SOHO [HA99,HA01] and TERRA were also attributed to transients. In some cases, such events produced resets by falsely triggering circuits designed to protect against over- voltage or over-current. On at least three occasions, transients caused satellites to switch into "safe mode" in which most of the systems on board the satellites were powered down for an extended period. By the time the satellites were reconfigured and returned to full operational state, much scientific data had been lost. Fortunately, no permanent damage occurred in any of the systems and they were all successfully re-activated.

Buchner, Stephen↗

Suppression of Transient Events by Levitation (STABLE): Results From the USML-2 Mission

Microgravity science payloads can be extremely sensitive to vibrations from machinery, acoustics, ventilation, and crew activity. Suppression of Transient Acceleration by Levitation (STABLE) is an active vibration isolation system designed to protect payloads from these disturbances. This paper gives an account of results from the flight demonstration of the STABLE microgravity isolation system, which was developed and successfully flight tested in orbit during USML-2, with the participation of Astronaut Fred Leslie. Following a very brief description of the operational principles, the hardware and software design, and performance criteria, results of the analysis of measured flight data are presented to provide an evaluation of system performance parameters, including acceleration attenuation, assessment of sway space, system power consumption, and other factors critical to the performance of an isolation system. Lessons learned and potential design improvements and evolutions are discussed. Data reduction by Robert Boucher of McDonnell Douglas Aerospace (MDA) was substantially assisted by Kenneth Hrovat of Tal-Cut, Inc., under support from National Aeronautics and Space Administration/Lewis Research Center (LeRC), Cleveland, OH.

Nurre, Gerald S.↗

Analyses Of Transient Events In Complex Valve and Feed Systems

Valve systems in rocket propulsion systems and testing facilities are constantly subject to dynamic events resulting from the timing of valve motion leading to unsteady fluctuations in pressure and mass flow. Such events can also be accompanied by cavitation, resonance, system vibration leading to catastrophic failure. High-fidelity dynamic computational simulations of valve operation can yield important information of valve response to varying flow conditions. Prediction of transient behavior related to valve motion can serve as guidelines for valve scheduling, which is of crucial importance in engine operation and testing. In this paper, we present simulations of the diverse unsteady phenomena related to valve and feed systems that include valve stall, valve timing studies as well as cavitation instabilities in components utilized in the test loop.

Ahuja, Vineet↗

Computed Tomography Imaging Spectrometer (CTIS) with 2D Reflective Grating for Ultraviolet to Long-Wave Infrared Detection Especially Useful for Surveying Transient Events

The optical system of this invention is an unique type of imaging spectrometer, i.e. an instrument that can determine the spectra of all points in a two-dimensional scene. The general type of imaging spectrometer under which this invention falls has been termed a computed-tomography imaging spectrometer (CTIS). CTIS's have the ability to perform spectral imaging of scenes containing rapidly moving objects or evolving features, hereafter referred to as transient scenes. This invention, a reflective CTIS with an unique two-dimensional reflective grating, can operate in any wavelength band from the ultraviolet through long-wave infrared. Although this spectrometer is especially useful for events it is also for investigation of some slow moving phenomena as in the life sciences.

Daniel W Wilson↗

Computed tomography imaging spectrometer (CTIS) with 2D reflective grating for ultraviolet to long-wave infrared detection especially useful for surveying transient events

The optical system of this invention is an unique type of imaging spectrometer, i.e. an instrument that can determine the spectra of all points in a two-dimensional scene. The general type of imaging spectrometer under which this invention falls has been termed a computed-tomography imaging spectrometer (CTIS). CTIS's have the ability to perform spectral imaging of scenes containing rapidly moving objects or evolving features, hereafter referred to as transient scenes. This invention, a reflective CTIS with an unique two-dimensional reflective grating, can operate in any wavelength band from the ultraviolet through long-wave infrared. Although this spectrometer is especially useful for rapidly occurring events it is also useful for investigation of some slow moving phenomena as in the life sciences.

Wilson, Daniel W.↗

Location of the gamma-ray transient event of 1979 March 5

The paper discusses the gamma event of Mar. 5, 1979, the most intense burst of nonsolar high-energy photons ever recorded, which was observed by 12 gamma burst instruments on nine spacecraft. The fast rise time of the event and ephemeris and absolute time information from the spacecraft are considered, and a unique and redundantly determined 1 x 2 arcmin error box centered at R.A. = 5h 25.95m, decl. = -66 deg 07.1 arcmin (equinox 1950.0) is found. Statistical arguments favor identification with the SNR N49, located within the box. It is suggested that if N49 was the source of the transient, then peak gamma-ray and hard X-5ay luminosity was between 10 to the 44th and 10 to the 45th ergs/s, and the total radiated energy was between 10 to the 43rd and 10 to the 44th ergs.

Evans, W. D.↗

High time resolution observation of the transient event of 5 March 1979

The detection of an intense gamma ray burst with the monitor proportional counter on the HEAO 2 spacecraft is discussed with particular emphasis on the measurement of the time of onset of the event. Based on the mean observed counting rate in the burst and assuming a sharp rise, the uncertainty in the burst onset is found to be + or - 220 microseconds. The time of occurrence was 57124.826908 + or - 0.000220 s UT on March 5, 1979, and the location of the HEAO 2 satellite at this time was latitude 22.15 deg, longitude -27.60 deg at an altitude of 525.0 km.

Weisskopf, M. C.↗

Periodicity of the gamma-ray transient event of 5 March 1979

An unusual gamma-ray burst event was observed on 5 March 1979 by nine different spacecraft. The position of the event has been accurately determined as r.a. = 5 h 25.95 min, dec = -66 deg 07.1 arcmin (epoch 1950.0), coincident with the location of the supernova remnant N49 in the Large Magellanic Cloud. The burst was of very high intensity, and if isotropic and located at the distance (approximately 55 kpc) of N49 had a peak luminosity of greater than 10 to the 44th erg/sec. Even more interesting is the obvious 8-s periodicity of the event, following the initial very intense outburst. The time history and power spectrum of this event as determined from Pioneer Venus Orbiter data is here reported.

Terrell, J.↗

A fast data acquisition system for the study of transient events by high repetition rate time-of-flight mass spectrometry

Recent advances in commercially available data acquisition electronics embodying high speed A/D conversion coupled to increased memory storage have now made practical (at least within time intervals of a third of a millisecond or more) the capturing of all of the data generated by a high repetition rate time-of-flight mass spectrometer producing complete spectra every 25 to 35 microseconds. Such a system was assembled and interfaced with a personal computer for control and management of data. The applications are described for recording time-resolved spectra of individual vapor plumes induced from the pulsed-laser heating of material. Each laser pulse triggers the system to generate automatically a 3-dimensional (3-D) presentation of the time-resolved spectra with m/z labeling of the major mass peaks, plus an intensity versus time display of both the laser pulse and the resulting vapor pulse. The software also permits storing of data and its presentation in various additional forms.

Lincoln, K. A.↗

Transient events in the outer magnetosphere - Boundary waves of flux transfer events?

Simultaneous solar wind and magnetospheric observations are presented for a series of flux transfer events (FTEs) observed by the UKS and IRM spacecraft in the outer prenoon magnetosphere on October 28, 1984. The CCE satellite, located near local noon, observed an enhancement in the magnetospheric magnetic field strength 4 min prior to each IRM/UKS event, suggesting the antisunward propagation of a compression in the magnetopause surface. It is suggested that these compressions resulted from wavy magnetopause motion driven by variations in the solar wind dynamic pressure applied to the magnetosphere, rather than the motion of FTEs formed by magnetic merging. This hypothesis is confirmed by the fact that the events previously identified as FTEs occurred during a sequence of quasi-periodic (5-6 min) oscillations in the magnetospheric plasma velocity and magnetic field.

Sibeck, D. G.↗

Single-Event Transient Testing of Low Dropout PNP Series Linear Voltage Regulators

As demand for high-speed, on-board, digital-processing integrated circuits on spacecraft increases (field-programmable gate arrays and digital signal processors in particular), the need for the next generation point-of-load (POL) regulator becomes a prominent design issue. Shrinking process nodes have resulted in core rails dropping to values close to 1.0 V, drastically reducing margin to standard switching converters or regulators that power digital ICs. The goal of this task is to perform SET characterization of several commercial POL converters, and provide a discussion of the impact of these results to state-of-the-art digital processing IC through laser and heavy ion testing

Adell, Philippe↗