Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “tracker”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

OT-$\mu$DTC, a test bench for testing CMS Outer Tracker Phase-2 module prototypes

The Compact Muon Solenoid (CMS) experiment plans to replace its strip tracker system with a completely new Outer Tracker system to cope with the higher luminosity, compared to Run 2 operation, provided by the HL-LHC. This CMS Phase-2 Outer Tracker will be build up from two types of modules both consisting out of two parallel silicon sensors separated by a few millimetres. To read out the two types of modules four Outer Tracker specific custom chips are required. This proceeding introduces the module concept, goes into more detail on the data path, discusses the test system (OT-$\mu$DTC) designed for testing prototypes based on these ASICs and gives examples of test results obtained with this test system.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Solar-Tracker Diffuse-Response Algorithm for Balancing Energy Gain and Mechanical Wear in Photovoltaic Systems

Single-axis solar tracking maximizes photovoltaic energy production under clear-sky conditions; however, its effectiveness decreases under cloudy and overcast skies, where diffuse irradiance dominates and the optimal module orientation changes. Conventional tracking algorithms either neglect sky conditions or rely on simplified diffuse-response strategies that may trigger frequent tracker repositioning under variable cloud cover, leading to increased mechanical wear with marginal energy gains. This work proposes an enhanced diffuse-response tracking algorithm that explicitly accounts for both the intensity and temporal persistence of cloudiness. By requiring overcast conditions to persist for a minimum duration before reorienting the tracker to a diffuse-stow position, the proposed approach reduces unnecessary movements while preserving the benefits of diffuse-response operation. The algorithm is evaluated through numerical simulations based on historical meteorological data and validated using field measurements on monofacial and bifacial photovoltaic strings. The results show that the proposed strategy reduces excess tracker movement from 114% to 0.16% while maintaining nearly the same energy yield. Compared to a conventional diffuse-response algorithm, the associated energy reduction is minimal (≈0.17%) relative to the ≈0.37% yield gain observed at the studied location. These findings demonstrate that incorporating cloudiness duration enables a practical compromise between energy performance and tracker durability, particularly for monofacial photovoltaic systems.

14 SOLAR ENERGY↗

Single-Axis Tracker Control Optimization Potential for the Contiguous United States: Preprint

Conventional tracker control algorithms maximize collection of direct irradiance with no regard for collection of diffuse irradiance. Therefore, a tracker control algorithm that optimizes for maximal total irradiance, not just direct, might realize improved insolation collection. Using weather data gridded at 0.25° by 0.25° latitude/longitude spacing covering the contiguous United States, we evaluate the insolation gain of two alternative control algorithms optimized for improved total irradiance collection in monofacial arrays and present annual and monthly geographic heatmaps showing the gains across the contiguous United States. Certain locations show potential annual insolation gains approaching 1.0%, but most locations with recently-built tracker systems show annual gains between 0.1% and 0.4%. We also demonstrate a relationship between a climate's annualized diffuse insolation fraction and its potential tracker optimization insolation gain.

diffuse↗

Power Studies for the CMS Pixel Tracker

The Electronic Systems Engineering Department of the Computing Division at the Fermi National Accelerator Laboratory is carrying out R&D investigations for the upgrade of the power distribution system of the Compact Muon Solenoid (CMS) Pixel Tracker at the Large Hadron Collider (LHC). Among the goals of this effort is that of analyzing the feasibility of alternative powering schemes for the forward tracker, including DC to DC voltage conversion techniques using commercially available and custom switching regulator circuits. Tests of these approaches are performed using the PSI46 pixel readout chip currently in use at the CMS Tracker. Performance measures of the detector electronics will include pixel noise and threshold dispersion results. Issues related to susceptibility to switching noise will be studied and presented. In this paper, we describe the current power distribution network of the CMS Tracker, study the implications of the proposed upgrade with DC-DC converters powering scheme and perform noise susceptibility analysis.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Status of the D0 fiber tracker and preshower detectors

In this report we focus on the performance of the D0 central fiber tracker and preshower detectors during the high luminosity p{bar p} collisions at {radical}s = 1.96 GeV delivered by the Tevatron collider at Fermilab (Run IIb). Both fiber tracker and preshower detectors utilize a similar readout system based on high quantum efficiency solid state photo-detectors capable of converting light into electrical signals. We also give a brief description of the D0 detector and the central track trigger, and conclude with a summary on the central tracker performance.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Czochralski Silicon as a Detector Material for S-LHC Tracker Volumes

With an expected ten-fold increase in luminosity in S-LHC, the radiation environment in the tracker volumes will be considerably harsher for silicon-based detectors than the already harsh LHC environment. Since 2006, a group of CMS institutes, using a modified CMS DAQ system, has been exploring the use of Magnetic Czochralski silicon as a detector element for the strip tracker layers in S-LHC experiments. Both p+/n-/n+ and n+/p-/p+ sensors have been characterized, irradiated with proton and neutron sources, assembled into modules, and tested in a CERN beamline. There have been three beam studies to date and results from these suggest that both p+/n-/n+ and n+/p-/p+ Magnetic Czochralski silicon are sufficiently radiation hard for the $R>25$ cm regions of S-LHC tracker volumes. The group has also explored the use of forward biasing for heavily irradiated detectors, and although this mode requires sensor temperatures less than -50\,$^\circ$C, the charge collection efficiency appears to be promising.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

How should regulators view cost trackers?

State commissions have not given adequate attention to the negative features of cost trackers, which are at odds with the public interest. Specifically, cost trackers diminish the positive effects of regulatory lag and retrospective reviews in deterring utility waste and cost inefficiency. Trackers also could reduce regulatory scrutiny in evaluating cost prudence. (author)

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Reconstruction of neutrino induced NC-1π{sup 0} using the T2K-ND280 tracker

Single π{sup 0} production is the one of the most important backgrounds in the υ{sub e} appearance measurement in T2K. Large uncertainties in this production make it difficult to predict. Measurement at the near detector (ND280) is required both to constrain the background prediction at the far detector (Super-K) and also at the near detector to improve knowledge of beam υ{sub e} contamination. We present an analysis based on Monte Carlo simulation of neutral current (NC) single π{sup 0} in the tracker region. NC-1π{sup 0} events are selected using a specific two-gamma signature in the tracker region. One decay gamma is reconstructed by selecting an e+/e− pair starting in the Fine-Grained target Detector (FGD) and extending into the TPC, where the leptons can be identified and their momentum measured accurately. The second gamma is then selected in-time in the Calorimeter modules surrounding the tracker. Selections cuts, efficiency and purity of the selection are presented and projection of the expected number of single π{sup 0} candidates for 3 × 10{sup 20} protons on target (PoT) exposure is made.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Shaded fraction and backtracking in single-axis trackers on rolling terrain

A generalized closed-form equation for the shaded collector fraction in solar arrays on rolling or undulating terrain is provided for single-axis tracking and fixed-tilt systems. The equation accounts for different rotation angles between the shaded and shading trackers, cross-axis slope between the two trackers, and offset between the collector plane and axis of rotation. The validity of the equation is demonstrated through comparison with numerical ray-tracing simulations and remaining minor sources of error are quantified. Additionally, a simple procedure to determine backtracking rotations for each row in an array installed on the rolling terrain (varying in the direction perpendicular to the tracker axes) is provided. The backtracking equation accounts for a desired shaded fraction (including complete shade avoidance) as well as an axis-collector offset. Test cases are provided to facilitate implementation of these equations.

14 SOLAR ENERGY↗

The Reconstruction Software for the Muon Ionization Cooling Experiment Trackers

The international Muon Ionisation Cooling Experiment (MICE) is designed to demonstrate the principle of muon ionization cooling, for application to a future Neutrino Factory or Muon Collider. In order to measure the change in emittance, MICE is equipped with a pair of high precision scintillating fibre trackers. The trackers are required to measure a 10% change in emittance to 1% accuracy (giving an overall precision of 0.1%). This paper describes the tracker reconstruction software, as a part of the overall MICE software framework, MAUS. Channel clustering is described, proceeding to the formation of space-points, which are then associated with particle tracks using pattern recognition algorithms. Finally a full custom Kalman track fit is performed, to account for energy loss and multiple scattering. Exemplar results are shown for Monte Carlo data.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A new strips tracker for the upgraded ATLAS ITk detector

The ATLAS detector has been created and determined to function in the environment of the present Large Hadron Collider (LHC). At the next-generation tracking detector proposed for the High Luminosity LHC (HL-LHC), the so-called ATLAS Phase-II Upgrade, the fluences and radiation levels will be higher by as much as a factor of ten. The new sub-detectors must thus be faster, of larger area, more segmented and more radiation hard while the amount of inactive material should be minimized and the power supply to the front-end systems should be increased. For those reasons, the current inner tracker of the ATLAS detector will be fully replaced by an all-silicon tracking system that consists of a pixel detector at small radius close to the beam line and a large area strip tracker surrounding it. This report gives an overview of the design of the strip inner tracker (Strip ITk) and summarises the intensive R&D activities performed over the last years by the numerous institutes within the Strips ITk collaboration. These studies are accompanied with a strong prototyping effort to contribute to the optimisation of the Strip ITk's structure and components. This effort culminated recently in the release of the ATLAS Strips ITk Technical Design Report (TDR).

Si microstrip and pad detectors↗

Comparative evaluation of analogue front-end designs for the CMS Inner Tracker at the High Luminosity LHC

The CMS Inner Tracker, made of silicon pixel modules, will be entirely replaced prior to the start of the High Luminosity LHC period. One of the crucial components of the new Inner Tracker system is the readout chip, being developed by the RD53 Collaboration, and in particular its analogue front-end, which receives the signal from the sensor and digitizes it. Three different analogue front-ends (Synchronous, Linear, and Differential) were designed and implemented in the RD53A demonstrator chip. A dedicated evaluation program was carried out to select the most suitable design to build a radiation tolerant pixel detector able to sustain high particle rates with high efficiency and a small fraction of spurious pixel hits. The test results showed that all three analogue front-ends presented strong points, but also limitations. The Differential front-end demonstrated very low noise, but the threshold tuning became problematic after irradiation. Moreover, a saturation in the preamplifier feedback loop affected the return of the signal to baseline and thus increased the dead time. The Synchronous front-end showed very good timing performance, but also higher noise. For the Linear front-end all of the parameters were within specification, although this design had the largest time walk. This limitation was addressed and mitigated in an improved design. The analysis of the advantages and disadvantages of the three front-ends in the context of the CMS Inner Tracker operation requirements led to the selection of the improved design Linear front-end for integration in the final CMS readout chip.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Operation and performance of the CMS silicon strip tracker with proton-proton collisions at the CERN LHC

Salient aspects of the commissioning, calibration, and performance of the CMS silicon strip tracker are discussed, drawing on experience during operation with proton-proton collisions delivered by the CERN LHC. The data were obtained with a variety of luminosities. The operating temperature of the strip tracker was changed several times during this period and results are shown as a function of temperature in several cases. Details of the system performance are presented, including occupancy, signal-to-noise ratio, Lorentz angle, and single-hit spatial resolution. Saturation effects in the APV25 readout chip preamplifier observed during early Run 2 are presented, showing the effect on various observables and the subsequent remedy. Studies of radiation effects on the strip tracker are presented both for the optical readout links and the silicon sensors. The observed effects are compared to simulation, where available, and they generally agree well with expectations.

47 OTHER INSTRUMENTATION↗

Studies of the CMS Tracker at High TriggerRrate

During the latter months of 2006 and the first half of 2007, the CMS Tracker was assembled and operated at the Tracker Integration Facility at CERN. During this period the performance of the tracker at trigger rates up to 100 kHz was assessed, and a source of high occupancy events was uncovered, diagnosed, and mitigated.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Operation and performance of the ATLAS silicon micro-strip tracker

The Semiconductor Tracker (SCT) is the key precision tracking device in ATLAS, made from silicon micro-strip detectors processed in the planar p-in-n technology. The completed SCT has been installed inside the ATLAS experimental hall since 2007 and has been operational since then. In this paper the current status of the Semiconductor Tracker is reviewed, including results from the data-taking periods in 2009 and 2010, and from the detector alignment. The emphasis is given to the performance of the Semiconductor Tracker with the LHC in collision mode and to the performance of individual electronic components. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A Linear Programming Approach to Backtracking for Single-Axis Trackers on Rolling Terrain

In this article, we present a computationally efficient method for determining optimal backtracking rotations for single-axis solar trackers on nonuniform terrain. The method allows for ganged tracking, mechanical rotation constraints, uneven row spacing, and arbitrary maximum allowable shaded fractions (to enable “fractional backtracking”). As with previous 2-D approaches, the method is suitable for terrain that varies in the transverse direction with respect to the rotation axis of the trackers. The novelty of the method lies in formulating the problem of shade avoidance as a linear problem, which is achieved by using the row interception width as the optimization variable instead of rotation angles. Formulating backtracking as a linear problem enables the use of extremely efficient linear programming algorithms, making the method highly scalable, requiring less than 1 min to compute optimal rotation schedules for hundreds of trackers. It also produces more effective backtracking rotations, reducing the frequency of shading by 4× and improving system energy output by 1%–2%.

Optimization↗

Monolithic Telescope-Based Star Tracker Final Report CRADA No. TC02205.0

This was a collaborative effort between LLNS as manager and operator of Lawrence Livermore National Laboratory (LLNL) and Millennium Space Systems, Inc. ("MSS" or "Participant"), to work on a Star Tracker based on the LLNL-developed monolithic telescope ("MonoTele"). The technical objectives of this CRADA were (1) to build, launch, and characterize a Star Tracker based on an existing Model V4 monolithic telescope, and (2) to design an optimized star tracker based on a wide field of view monolithic telescope.

42 ENGINEERING↗

Simulation of CMS Phase 2 Pixel Tracker for HL-LHC [Slides]

The High-Luminosity Large Hadron Collider (HL-LHC) aims to increase luminosity by a factor of 10 beyond the LHC's design value. To cope with the increased rate of particle production without compromising physics performance, the LHC detectors will undergo an extensive upgrade. CMS will replace the current inner tracker system with a new silicon tracker which will feature increased forward acceptance, improved radiation hardness, higher granularity, and compatibility with higher data rates. We present a simulation study of the CMS Phase 2 pixel tracker that investigates the expected occupancy and tracking performance for various geometric and sensor granularity options.

43 PARTICLE ACCELERATORS↗