Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “tomography problems”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Survey of Deep Learning and Physics-Based Approaches in Computational Wave Imaging

Computational wave imaging (CWI) extracts hidden structure and physical properties of a volume of material by analyzing wave signals that traverse that volume. Applications include seismic exploration of the Earth’s subsurface, acoustic imaging and nondestructive testing (NDT) in material science, and ultrasound computed tomography (USCT) in medicine. Current approaches for solving CWI problems can be divided into two categories: those rooted in traditional physics and those based on deep learning. Physics-based methods stand out for their ability to provide high-resolution and quantitatively accurate estimates of acoustic properties within the medium. However, they can be computationally intensive and are susceptible to ill-posedness and nonconvexity typical of CWI problems. Machine learning (ML)-based computational methods have recently emerged, offering a different perspective to address these challenges. Diverse scientific communities have independently pursued the integration of deep learning in CWI. This review discusses how contemporary scientific ML techniques, and deep neural networks in particular, have been developed to enhance and integrate with traditional physics-based methods for solving CWI problems. We present a structured framework that consolidates existing research spanning multiple domains, including computational imaging, wave physics, and data science. This study concludes with important lessons learned from existing ML-based methods and identifies technical hurdles and emerging trends through a systematic analysis of the extensive literature on this topic.

42 ENGINEERING↗

HYPPO: A Surrogate-Based Multi-Level Parallelism Tool for Hyperparameter Optimization

We present a new software, HYPPO, that enables the automatic tuning of hyperparameters of various deep learning (DL) models. Unlike other hyperparameter optimization (HPO) methods, HYPPO uses adaptive surrogate models and directly accounts for uncertainty in model predictions to find accurate and reliable models that make robust predictions. Using asynchronous nested parallelism, we are able to significantly alleviate the computational burden of training complex architectures and quantifying the uncertainty. HYPPO is implemented in Python and can be used with both TensorFlow and PyTorch libraries. We demonstrate various software features on time-series prediction and image classification problems as well as a scientific application in computed tomography image reconstruction. Finally, we show that (1) we can reduce by an order of magnitude the number of evaluations necessary to find the most optimal region in the hyperparameter space and (2) we can reduce by two orders of magnitude the throughput for such HPO process to complete.

adaptation models↗

NDE of titanium alloy MMC rings for gas turbine engines

Progress in the processing and fabrication of metal matrix composites (MMC's) requires appropriate mechanical and nondestructive testing methods. These methods are needed to characterize properties, assess integrity, and predict the life of engine components such as compressor rotors, blades, and vanes. Capabilities and limitations of several state-of-the-art nondestructive evaluation (NDE) technologies are investigated for characterizing titanium MMC rings for gas turbine engines. The use of NDE technologies such as x-ray computed tomography, radiography, and ultrasonics in identifying fabrication-related problems that caused defects in components is examined. Acousto-ultrasonics was explored to assess degradation of material mechanical properties by using stress wave factor and ultrasonic velocity measurements before and after the burst testing of the rings.

Baaklini, George Y.↗

Removing Stripes, Scratches, and Curtaining with Nonrecoverable Compressed Sensing

Highly-directional image artifacts such as ion mill curtaining, mechanical scratches, or image striping from beam instability degrade the interpretability of micrographs. These unwanted, aperiodic features extend the image along a primary direction and occupy a small wedge of information in Fourier space. Deleting this wedge of data replaces stripes, scratches, or curtaining, with more complex streaking and blurring artifacts—known within the tomography community as “missing wedge” artifacts. Here, we overcome this problem by recovering the missing region using total variation minimization, which leverages image sparsity-based reconstruction techniques—colloquially referred to as compressed sensing (CS)—to reliably restore images corrupted by stripe-like features. Our approach removes beam instability, ion mill curtaining, mechanical scratches, or any stripe features and remains robust at low signal-to-noise. In conclusion, the success of this approach is achieved by exploiting CS's inability to recover directional structures that are highly localized and missing in Fourier Space.

47 OTHER INSTRUMENTATION↗

Boosting Noise2Inverse via enhanced model selection for denoising computed tomography data

Synchrotron-based x-ray tomographic imaging enables the examination of the internal structure of materials at high spatial and temporal resolution. Experimental constraints can impose dose and time limits on the measurements, introducing a higher level of noise and artifacts in the reconstructed images. Deep learning has emerged as a powerful tool to remove noise from reconstructed images. Recently, the Noise2Inverse method was designed specifically for denoising reconstructed images without requiring paired noisy and clean images. This method creates multiple statistically independent reconstructions used to pair the data in which training involves transforming one reconstruction into the other, and vice versa. Originally designed to be used after a fixed number of epochs, we see in practice that this approach may not produce the optimal model and may unnecessarily waste computational resources. Therefore, we propose an alternative method of identifying the best model during training that aligns with the Noise2Inverse method. During validation, we compare the model output of the multiple reconstructions among each other. We hypothesize that the best model is the one that produces images with the highest similarity, implying a convergence in the predicted material properties and absorption values. To compare model outputs, we consider the absolute error, square error, structural similarity index (SSIM), peak signal-to-noise ratio (PSNR), and cosine similarity. We evaluate our method on two simulated tomography datasets and two, real-world, low-contrast, high-energy x-ray tomography datasets. We show our approach is more effective at determining the best model, up to an increase of 12.50% and 12.53% in SSIM and PSNR, respectively, while only requiring a fifth of the training time compared to the original approach.

CT↗

Three-dimensional structure of buried heterointerfaces revealed by multislice ptychography

Here, we report on the three-dimensional (3D) structure determination of a twisted hexagonal boron nitride (h-BN) heterointerface from a single-view dataset using multislice ptychography. We identify the buried heterointerface between two twisted h-BN flakes with a lateral resolution of 0.57 Å and a depth resolution of 2.5 nm. The latter represents a significant improvement (∼2.7 times) over the aperture-limited depth resolution of incoherent imaging modes, such as annular-dark-field scanning transmission electron microscopy. This improvement is attributed to the diffraction signal extending beyond the aperture edge, with the depth resolution set by the curvature of the Ewald sphere. Future advancements in this approach could enhance the depth resolution to the subnanometer level and enable the identification of individual dopants, defects, and color centers in twisted heterointerfaces and other materials.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

DEVELOPMENT OF A NUCLEAR FUEL SAFEGUARDS VERIFICATION TECHNOLOGY FOR NEW FACILITY TYPES: Use of fast neutron emission tomography for spent fuel verification

With the buildup of spent fuel inventories around the world from decommissioning activities, a tool for the efficient and effective verification of a variety of fuel types for long-term disposition is needed. Fast neutron emission tomography is a promising imaging technology that can address this problem and has been under development at Oak Ridge National Laboratory for the past two years. The goal of this capability is to detect the removal or substitution of individual fuel pins in spent nuclear fuel assemblies for international safeguards applications. The present imaging technique is based on neutron emissions originating primarily from curium-244, which is produced predominantly at the end of the exposure cycle. As a result, this technique may be sensitive not only to fuel pins that are removed or substituted subsequent to all irradiation, but also to fuel pins that are substituted and subsequently irradiated. At present, a laboratory prototype imager is under construction. The purpose of the prototype is to demonstrate an imaging capabilitysufficient to resolve individual fuel pins using commercially available boron straw detectors that can withstand the high gamma ray dose from a typical spent fuel assembly. To achieve both practical measurement durations and sufficient resolution to discern individual pins, the prototype imager employs a novel collimator design where the slits of a parallel-slit collimator are rearranged to distribute them around a ring surrounding the target fuel assembly. This paper will report on simulations and experimental results undertaken to converge on a final design, image reconstruction of sample fuel types of interest, and challenges associated.

Iyengar, Anagha↗

Determining Biosignatures by Complexity Analysis in Antarctic Cryptoendolithic Communities

One of the most difficult problems of life detection is that of identifying biosignatures across a wide range of scales using multiple co-registered probes. The technique should be of equal utility across a wide range of search spaces from remote sensors probing volumes of space or planetary surfaces, visual eye or camera searches across the surface of a rock in Antarctica, low resolution microscopic scanning of a rock or a space craft in situ, or high resolution electron microscope and computerized tomography scanning of geobiological samples. We describe here an approach to this problem which derives in large part from past work done in the area of astrophysics - namely the analysis of complexity in galactic signals by data compression methods. This approach is a radically new one for geobiology and astrobiology, and allows us to assess the complexity (and thus potential biogenicity) of an object being examined. This is done by considering the information within pixels of an image (regardless the sensor used to gather the information) as an energetic system capable of description in terms of classical thermodynamics. The image data space is searched by an algorithm that judges complexity via data compression (e.g., the more compressible it is, the less complex, and vice versa) and maximum entropy as originally outlined by Shannon. At present we are implementing methods to utilize images from multiple sensors gathering different kinds of information (e.g., visible gray-scale data, color analyses, UV fluorescence, chemical information, etc). We present here preliminary data from deep UV fluorescence and ESEM (Environmental Scanning Electron Microscope) images from a layered cryptoendolithic community of an Antarctic rock.

Storrie-Lombardi, M. C.↗

Application of Computer Tomography for Life Detection

Perhaps one of the most fundamentally difficult challenges facing those who would search for life is that of scale determination. Spatial scales of life on Earth range over more than 15 orders of magnitude in mass and volume, and more than 8 orders of magnitude in 2 dimensional space. If the distribution of life is sparse in comparison to the background on which it is found, then the choice of the right scale is critical to finding that life. But how does one identify the proper scale? To put this in other words, how does one recognize the "haystacks" in which the needles (biosignatures and evidence of life) might be most profitably searched for? The problem is further exacerbated when conditions get extreme because much of the life moves from the clement surface environment into the pores and more clement environments inside of rocks, minerals and soils. Once encased in their lithic homes, these microbes become nearly impossible to study by standard techniques because of the opacity of the rocks. It is this problem that we propose to address in the work proposed here. Computer Tomography (CT) has been a very valuable tool in medicine, where the best resolution available has typically been of the order of about 0.5 mm. However, to adapt the approach for life detection of microbial endoliths, the resolution needs to be moved to the micrometer and even submicrometer levels. Thus for the studies proposed here, we begin with a commercially available instrument that can yield resolution of approximately 10 micrometers. The rational for this is twofold: first, this is the "state of the art" in laboratory instruments; and second, that while the usual size of a microbial cell is about 1 micron, microorganisms tend to live in communities that usually exceed the 10 micrometer size range. The resolution also depends on the sample size itself, so having a small lab instrument into which small samples can be placed will be beneficial to the resolution. We have now used several different CT systems, beginning with the medical scanners (Arcadia CT group) for the detection of layered communities in sandstone rocks from Antarctica. Even this crude instrument was able to point to the areas of the rock that were dominated by microbial populations - this provides the critical first information that says, "Go back and look at these sites with other methods." We showed that without sample preparation or destruction it was possible to gain knowledge as to the presence of density differences suggestive of life.

Tsapin, A.↗

Seismic Tomography 2024

Seismic tomography is the most abundant source of information about the internal structure of the Earth at scales ranging from a few meters to thousands of kilometers. It constrains the properties of active volcanoes, earthquake fault zones, deep reservoirs and storage sites, glaciers and ice sheets, or the entire globe. It contributes to outstanding societal problems related to natural hazards, resource exploration, underground storage, and many more. The recent advances in seismic tomography are being translated to nondestructive testing, medical ultrasound, and helioseismology. Nearly 50 yr after its first successful applications, this article offers a snapshot of modern seismic tomography. Focused on major challenges and particularly promising research directions, it is intended to guide both Earth science professionals and early-career scientists. The individual contributions by the coauthors provide diverse perspectives on topics that may at first seem disconnected but are closely tied together by a few coherent threads: multiparameter inversion for properties related to dynamic processes, data quality, and geographic coverage, uncertainty quantification that is useful for geologic interpretation, new formulations of tomographic inverse problems that address concrete geologic questions more directly, and the presentation and quantitative comparison of tomographic models. Finally, it remains to be seen which of these problems will be considered solved, solved to some extent, or practically unsolvable over the next decade.

58 GEOSCIENCES↗

Tomography of Accretion Flows in Binary Stars and Active Galactic Nuclei

Under this project, a variety of accretion problems have been studied, with two in particular. In the first, astrophysical jets are observed in many objects ranging from young stars to Active Galactic Nuclei. A major unsolved problem is how do these jets originate from accretion disks. In a series of works, I have examined the launching of outflows from magnetized disks, the extraction of energy from black holes, and the formation of jets in systems like Cataclysmic Variables and supermassive accreting black holes. The results of these works were published in a number of papers. In the second, I examined the potential role of vortices in accretion disks around Young Stellar Objects, for the formation of planets and for angular momentum transport. I showed that vortices are surprisingly stable, and that they are able to concentrate dust in their cores. I also examined the development of spiral shocks in disks. Finally, I studied the evolution of magnetically layered protoplanetary disks, and showed that they exhibit outbursts which could 'pump' the jets that are observed in Herbig-Haro objects. The results of these works were published in a number of papers as well. Additional information on the published papers is contained in the original abstract.

Livio, Mario↗

ALERT AATR Final Report: Lawrence Livermore National Laboratory

This report addresses the problem of automatically recognizing objects of interest (OOIs) in x-ray computed tomography (CT) images of baggage (plastic bins in our case). The discussion draws heavily from the material in [1]. The material composition and basic physical features of interest (FOIs, such as mass and thickness) of the OOIs are defined in an object requirement specification (ORS). The ORS may also provide a detection – false alarm probability goal for each material of interest (MOI). Automatic threat recognition (ATR) systems identify CT images of baggage that contain OOIs. ATRs must also identify locations of OOIs within baggage. The current ATR certification process used by DHS requires the ATR hardware and software to be certified on a specific ORS. When the ORS changes, the ATR hardware and software must be recertified. To pass re-certification, the hardware, algorithms and codes may need to be modified. Because ATR-based certification and re-certification are so time-consuming, the current process cannot quickly adapt to changing requirements. Unlike ATRs, adaptive automatic threat recognition (AATR) systems can quickly adapt to an ORS that changes or evolves over time [2]. The proposed AATR-based certification process would require the AATR hardware and software to be certified on a specific baseline ORS. Once certified, the same AATR hardware, algorithms and codes would be applied (by TSA or its delegates) to any ORS supplied in the future as input without going through lengthy recertification. This proposed process would enable the AATR to quickly adapt to changing requirements. This report describes the AATR developed at the Lawrence Livermore National Laboratory (LLNL) for x-ray CT images of baggage. The need and technical requirements for an AATR were developed in collaboration with DHS’s Explosives Division and Northeastern University’s Awareness and Localization of Explosives-Related Threats (ALERT) Center, a DHS Center of Excellence (http://www.northeastern.edu/alert/).

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Porosity Area Fraction Analysis of Bonded Borosilicate Specimens From in-Situ Optical Imagery

Image segmentation methods are routinely used to analyze data derived in nondestructive testing scenarios. A typical problem in this area is to estimate porosity from X-ray Computed Tomography (CT) inspections. This investigation aims to understand the effectiveness of open-source image segmentation methods for porosity estimation from optical images in the context of strength analysis of bonded materials and provides a benchmark of performance against a standard commercial software package. The rank ordering of the specimens by porosity area fraction is consistent across both methods.

Porosity area fraction↗

Porosity Area Fraction Analysis of Bonded Borosilicate Specimens From in-Situ Optical Imagery

Image segmentation methods are routinely used to analyze data derived in nondestructive testing scenarios. A typical problem in this area is to estimate porosity from X-ray Computed Tomography (CT) inspections. This investigation aims to understand the effectiveness of open-source image segmentation methods for porosity estimation from optical images in the context of strength analysis of bonded materials and provides a benchmark of performance against a standard commercial software package. The rank ordering of the specimens by porosity area fraction is consistent across both methods.

Porosity area fraction↗

Efficient quantum state tomography with mode-assisted training

Neural networks (NNs) representing quantum states are typically trained using Markov chain Monte Carlo based methods. However, unless specifically designed, such samplers only consist of local moves, making the slow-mixing problem prominent even for extremely simple quantum states. Here, we propose to use mode-assisted training that provides global information via the modes of the NN distribution. Further, applied to quantum state tomography using restricted Boltzmann machines, this method improves the quality of reconstructed quantum states by orders of magnitude. The method is applicable to other types of NNs and may efficiently tackle problems previously unmanageable.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

3D Experimental Measurements of Evolution of Force Chains in Natural Silica Sand

The mechanisms of force transmission in granular materials is a classic physics problem that has been addressed since the 19th century, when Heinrich Rudolf Hertz investigated the interaction between two similar objects that were in contact under compression. However, the study of force transmission mechanisms in assemblies of more particles has proven to be a formidable problem due to the complex nature of granular materials. In recent years, synchrotron microcomputed tomography (SMT) and three-dimensional X-ray diffraction microscopy (3DXRD) have been employed to study the mechanics of granular materials experimentally. Combining SMT and 3DXRD offers unique three-dimensional (3D) experimental measurements of the internal structure, kinematics (such as rotation and translation), and lattice strains of individual sand particles. In this paper, in situ SMT and 3DXRD scans were acquired at multiple load steps for a specimen composed of 2,705 natural Ottawa sand particles that were subjected to one-dimensional (1D) confined compression. An algorithm was developed to combine SMT images and 3DXRD lattice strain measurements and used to characterize the constitutive behavior of sand particles. The results were used to identify the crystal structure and the evolution of the stresses and lattice strains of individual sand particles. Another algorithm was developed to characterize the force structures within the specimen. Force structures were identified, and their properties (such as length) and evolution through the experiment were examined. The contact number of particles is a particle-scale property that affects the mechanics of granular materials. The effect of the contact number of the sand particles on the onset and evolution of the force structures was also investigated and discussed.

3D x-ray diffraction microscopy↗

Evaluation of the Feasibility of Utilizing a Low-Cost UWB Radar for Hardware Implant & Counterfeit Device Detection

Hardware implants & counterfeit devices in the US power grid pose a significant national security threat. Asset owners currently have few options for detecting the presence of such devices “in the wild”. The goal of this work is to develop a non-invasive sensing method to solve this problem. In this work we evaluate the feasibility of implementing a nonlinear UWB radar tomography system to differentiate between electronic internals of externally-similar devices using low-cost off-the-shelf hardware.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Holographic interferometric tomography for reconstructing flow fields

Holographic interferometric tomography is a technique for instantaneously capturing and quantitatively reconstructing three-dimensional flow fields. It has a very useful application potential for high-speed aerodynamics. However, three major challenging tasks need to be accomplished before its practical applications. First, fluid flows are mostly unsteady or at least non repeatable. Consequently, a means for Instantaneously recording three-dimensional flow fields, that is, a simple holographic technique for simultaneously recording multi-directional projections, needs to be developed. Second, while holographic interferometry provides enormous data storage capabilities, expeditious data extraction from complicated interferograms is very important for timely near real-time applications. Third, unlike medical applications, flow tomography does not provide complete data sets but instead involves ill-posed reconstruction problems of incomplete projection and limited angular scanning. During this summer research period, new experimental techniques and corresponding hardware were developed and tested to address the above mentioned tasks. The first task was achieved by diffuser illumination. This concept allows instantaneous capture of many projections with a conventional setup for single-projection recording. For the second task, a phase-shifting technique was incorporated. This technique allows one to acquire multiple phase-stepped interferograms for a single projection and thus to extract phase information from intensity data almost at real-time. For the third task, the research that has been extensively conducted previously was utilized. In this research period, a complete experimental setup that provides the above three major capabilities was designed, built, and tested by integrating all the techniques. A simple laboratory experiment for simulating wind-tunnel testing was then conducted. A test flow was produced by employing a relatively simple device that generated a gravity-driven flow. The flow was then experimentally investigated to check the viability of the holographic interferometric tomographic technique before wind-tunnel application.

Cha, Soyoung S.↗