Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “tomographic imaging”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Neural networks: Application to medical imaging

The research mission is the development of computer assisted diagnostic (CAD) methods for improved diagnosis of medical images including digital x-ray sensors and tomographic imaging modalities. The CAD algorithms include advanced methods for adaptive nonlinear filters for image noise suppression, hybrid wavelet methods for feature segmentation and enhancement, and high convergence neural networks for feature detection and VLSI implementation of neural networks for real time analysis. Other missions include (1) implementation of CAD methods on hospital based picture archiving computer systems (PACS) and information networks for central and remote diagnosis and (2) collaboration with defense and medical industry, NASA, and federal laboratories in the area of dual use technology conversion from defense or aerospace to medicine.

Clarke, Laurence P.↗

Associated Particle Imaging of Neutron Inelastic Scatter: 3-D Reconstruction, Capabilities, and Challenges

Associated particle imaging (API) offers unique advantages for 3-D imaging of neutron inelastic scatter, including single-view tomographic imaging and data acquisition when access is limited to only one side of the interrogated object. However, widespread adoption of neutron inelastic scatter imaging has been impeded by several inherent challenges, most prominently spatial resolution, self-attenuation, and statistical noise. Here, in this work, the capabilities and challenges of neutron inelastic scatter imaging are investigated. Instead of focusing on a single imaging application, we identify imaging principles that hold for various neutron inelastic scatter imaging techniques. The primary challenges for 3-D imaging are characterized. The inherent spatial resolution in the time-of-flight (TOF) dimension is derived based on the known system timing resolution and scan geometry. Three reconstruction algorithms are described and demonstrated, including the introduction of modern iterative reconstruction incorporating a physics-based system model. Simulation is leveraged to demonstrate imaging capability with varying coincidence count levels and system timing resolution. An example of measured data with both back-scatter and forward-scatter detector positioning is presented. System design characteristics and their effects on image quality are identified. The imaging framework presented in this article has the potential to facilitate growth of 3-D neutron inelastic scatter API by identifying applications that are a good match for the technique and by targeting system development resources toward the requirements of a specific imaging task.

Associated particle imaging (API)↗

Distributed Optimization for Nonrigid Nano-Tomography

Resolution level and reconstruction quality in nano-computed tomography (nano-CT) are in part limited by the stability of microscopes, because the magnitude of mechanical vibrations during scanning becomes comparable to the imaging resolution, and the ability of the samples to resist radiation induced deformations during data acquisition. In such cases, there is no incentive in recovering the sample state at different time steps like in time-resolved reconstruction methods, but instead the goal is to retrieve a single reconstruction at the highest possible spatial resolution and without any imaging artifacts. Here we propose a distributed optimization solver for tomographic imaging of samples at the nanoscale. Our approach solves the tomography problem jointly with projection data alignment, nonrigid sample deformation correction, and regularization. Projection data consistency is regulated by dense optical flow estimated by Farneback's algorithm, leading to sharp sample reconstructions with less artifacts. Synthetic data tests show robustness of the method to Poisson and low-frequency background noise. We accelerated the solver on multi-GPU systems and validated the method on three nano-imaging experimental data sets.

97 MATHEMATICS AND COMPUTING↗

Three-dimensional imaging of the myocardium with isotopes

Three methods of imaging the three-dimensional distribution of isotopes in the myocardium are discussed. Three-dimensional imaging was examined using multiple Anger-camera views. Longitudinal tomographic images with compensation for blurring were studied. Transverse-section reconstruction using coincidence detection of annihilation gammas from positron emitting isotopes was investigated.

Budinger, T. F.↗

Interlaboratory Study of Digital Volume Correlation Error Due to X-Ray Computed Tomography Equipment and Scan Parameters: an Update from the DVC Challenge

Background: The quality of Digital Volume Correlation (DVC) full-field displacement measurements depends directly on the characteristics of the X-ray Computed Tomography (XCT) equipment, and scan procedures used to acquire the tomographic images. Objective: In this work, we seek to experimentally study the effects of XCT equipment and tomographic scan procedures on the quality of these images for DVC analysis, and to survey the level of DVC error that may be achieved using standard XCT operating procedures. Methods: Six participants in an interlaboratory study acquired high-quality XCT scans of a syntactic foam before and after rigid body motion. The resulting images were correlated using commercial DVC software to quantify error sources due to random image noise, reconstruction artifacts, as well as systematic spatial or temporal distortion. Results: In the absence of rigid body motion, the standard deviation of the displacement measurements ranged from 0.012 to 0.043 voxels using a moderate subvolume size, indicating that subvoxel measurement resolution could readily be achieved with a variety of XCT equipment and scan recipes. Comparison of consecutive scans without rigid body motion showed transient dilatational displacement gradients due to self-heating of the X-ray source and/or thermal expansion of the foam. Evaluation of the scans after rigid body motion showed significant, machine-specific spatial distortion in the displacement fields of up to 0.5 voxels; new approaches to remove this error need to be developed. Conclusions: Analysis of the scan protocols used in the interlaboratory study, as well as a complementary parametric sensitivity study, showed that the DVC error was strongly influenced by the XCT equipment, but could be mitigated by adjusting the total scan duration.

47 OTHER INSTRUMENTATION↗

Fast Hyperspectral Neutron Tomography

Hyperspectral neutron computed tomography is a tomographic imaging technique in which thousands of wavelength-specific neutron radiographs are measured for each tomographic view. In conventional hyperspectral reconstruction, data from each neutron wavelength bin are reconstructed separately, which is extremely time-consuming. These reconstructions often suffer from poor quality due to low signal-to-noise ratios. Consequently, material decomposition based on these reconstructions tends to produce inaccurate estimates of the material spectra and erroneous volumetric material separation. In this paper, we present two novel algorithms for processing hyperspectral neutron data: fast hyperspectral reconstruction and fast material decomposition. Both algorithms rely on a subspace decomposition procedure that transforms hyperspectral views into low-dimensional projection views within an intermediate subspace, where tomographic reconstruction is performed. The use of subspace decomposition dramatically reduces reconstruction time while reducing both noise and reconstruction artifacts. We apply our algorithms to both simulated and measured neutron data and demonstrate that they reduce computation and improve the quality of the results relative to conventional methods.

Chowdhury, Mohammad Samin Nur [Purdue University]↗

A versatile high-speed x-ray microscope for sub-10 nm imaging

We have developed a next-generation scanning x-ray microscope RASMI (RApid Scanning Microscopy Instrument) for high-throughput tomographic imaging. RASMI is installed at the hard x-ray nanoprobe beamline at NSLS-II and is capable of manipulating 1D multilayer Laue lenses (MLLs) and 2D optics (both zone plates and monolithically assembled 2D MLLs). The sample scanning stage utilizes line-focusing interferometry as an encoder while performing fly-scanning data acquisition. The system can be configured for both position- and time-triggering modes during fly-scanning. The microscope demonstrated a detector-limited data acquisition rate of 1.25 kHz during ptychography measurements. The initial x-ray results yielded a sample-limited resolution of ∼6 nm in 2D. RASMI can be adopted for in-vacuum applications and is a foundation for the next-generation scanning microscopy systems to be developed and commissioned at NSLS-II.

36 MATERIALS SCIENCE↗

4D insights into lithium-ion battery sidewall rupture during thermal runaway

Thermal runaway (TR), characterized by rapid exothermic reactions, presents a serious safety risk in lithium-ion batteries (LiBs). External triggers such as high temperatures, mechanical abuse, or internal short circuits (ISCs) can initiate TR, often resulting in sidewall rupture, which may escalate to catastrophic battery pack failure. In this study, we developed and applied high-speed synchrotron imaging techniques to investigate sidewall rupture mechanisms in LiBs subjected to different triggering scenarios. Using in situ 4D tomographic imaging, we visualized the dynamic evolution of sidewall rupture with high spatial and temporal resolution. The results revealed distinct failure behaviors linked to each trigger, underscoring the complex and condition-specific nature of sidewall breach and battery failure. These insights highlight the critical importance of implementing tailored safety strategies across diverse applications. Our findings demonstrate the powerful potential of synchrotron high-speed tomography as a diagnostic tool for advanced safety testing and cell qualification.

25 ENERGY STORAGE↗

Diffractive Optical Elements for Spectral Imaging

Diffractive optical elements fabricated on flat and non-flat substrates frequently act as dispersive elements in imaging spectrometers. We describe the design and electron-beam fabrication of blazed and computer-generated-hologram gratings for slit and tomographic imaging spectrometers.

diffractive optics gratings spectral imaging imagi↗

Diffractive Optical Elements for Spectral Imaging

Diffractive optical elements fabricated on flat and non-flat substrates frequently act as dispersive elements in imaging spectrometers. We describe the design and electron-beam fabrication of blazed and computer-generated-hologram gratings for slit and tomographic imaging spectrometer.

diffractive optics gratings spectral imaging imagi↗

X-ray scattering based scanning tomography for imaging and structural characterization of cellulose in plants

X-ray and neutron scattering have long been used for structural characterization of cellulose in plants. Due to averaging over the illuminated sample volume, these measurements traditionally overlooked the compositional and morphological heterogeneity within the sample. Here, a scanning tomographic imaging method is described, using contrast derived from the X-ray scattering intensity, for virtually sectioning the sample to reveal its internal structure at a resolution of a few micrometres. This method provides a means for retrieving the local scattering signal that corresponds to any voxel within the virtual section, enabling characterization of the local structure using traditional data-analysis methods. This is accomplished through tomographic reconstruction of the spatial distribution of a handful of mathematical components identified by non-negative matrix factorization from the large dataset of X-ray scattering intensity. Joint analysis of multiple datasets, to find similarity between voxels by clustering of the decomposed data, could help elucidate systematic differences between samples, such as those expected from genetic modifications, chemical treatments or fungal decay. The spatial distribution of the microfibril angle can also be analyzed, based on the tomographically reconstructed scattering intensity as a function of the azimuthal angle.

36 MATERIALS SCIENCE↗

3D tracking of particles in a dusty plasma by laser sheet tomography

The collective behavior of levitated particles in a weakly ionized plasma (dusty plasma) has raised significant scientific interest. This is due to the complex array of forces acting on the particles and their potential to act as in situ diagnostics of the plasma environment. Ideally, the three-dimensional (3D) motion of many particles should be tracked for long periods of time. Typically, stereoscopic imaging using multiple cameras combined with particle image velocimetry is used to obtain a velocity field of many particles, yet this method is limited by its sample volume and short time scales. Here, we demonstrate a different, high-speed tomographic imaging method capable of tracking individual particles. We use a scanning laser sheet coupled to a single high-speed camera. We are able to identify and track tens of individual particles over centimeter length scales for several minutes, corresponding to more than 10 000 frames.

Physics↗

Development of Multi-Scale X-ray Fluorescence Tomography for Examination of Nanocomposite-Treated Biological Samples

Research in cancer nanotechnology is entering its third decade, and the need to study interactions between nanomaterials and cells remains urgent. Heterogeneity of nanoparticle uptake by different cells and subcellular compartments represent the greatest obstacles to a full understanding of the entire spectrum of nanomaterials’ effects. In this work, we used flow cytometry to evaluate changes in cell cycle associated with non-targeted nanocomposite uptake by individual cells and cell populations. Analogous single cell and cell population changes in nanocomposite uptake were explored by X-ray fluorescence microscopy (XFM). Very few nanoparticles are visible by optical imaging without labeling, but labeling increases nanoparticle complexity and the risk of modified cellular uptake. XFM can be used to evaluate heterogeneity of nanocomposite uptake by directly imaging the metal atoms present in the metal-oxide nanocomposites under investigation. While XFM mapping has been performed iteratively in 2D with the same sample at different resolutions, this study is the first example of serial tomographic imaging at two different resolutions. A cluster of cells exposed to non-targeted nanocomposites was imaged with a micron-sized beam in 3D. Next, the sample was sectioned for immunohistochemistry as well as a high resolution “zoomed in” X-ray fluorescence (XRF) tomography with 80 nm beam spot size. Multiscale XRF tomography will revolutionize our ability to explore cell-to-cell differences in nanomaterial uptake.

60 APPLIED LIFE SCIENCES↗

Exploring the Great Pyramid

For centuries, the pyramids at Giza have been the object of frequent speculation and study. L. Alvarez et al. in 1970 and the ScanPyramids collaboration in 2017 have very successfully implemented HEP detector technology to image the pyramid of Khafre and the Great Pyramid of Khufu, respectively. Numerous questions about Khufu’s structure remain, however. The EGP project aims to undertake a new study of this enigmatic monument’s interior by applying high-resolution tomographic imaging and reconstruction, which will permit a detailed understanding of internal variations in density and may offer insight regarding exactly how Egypt’s largest pyramid was built.

43 PARTICLE ACCELERATORS↗

Complete Tem-Tomography: 3D Structure of Gems Cluster

GEMS (glass with embedded metal and sulfide) grains in interplanetary dust particles (IDPs) are considered to be one of the ubiquitous and fundamental building blocks of solids in the Solar System. They have been considered to be interstellar silicate dust that survived various metamorphism or alteration processes in the protoplanetary disk but the elemental and isotopic composition measurements suggest that most of them have been formed in the protoplanetary disk as condensates from high temperature gas. This formation model is also supported by the formation of GEMS-like grains with respect to the size, mineral assemblage, texture and infrared spectrum by condensation experiments from mean GEMS composition materials. Previous GEMS studies were performed only with 2D observation by transmission electron microscopy (TEM) or scanning TEM (STEM). However, the 3D shape and structure of GEMS grains and the spatial distribution of Fe/FeS's has critical information about their formation and origin. Recently, the 3D structure of GEMS grains in ultrathin sections of cluster IDPs was revealed by electron tomography using a TEM/STEM (JEM-2100F, JEOL). However, CT images of thin sections mounted on Cu grids acquired by conventional TEM-tomography are limited to low tilt angles (e. g., less than absolute value of 75 deg. In fact, previous 3D TEM observations of GEMS were affected by some artifacts related to the limited tilt range in the TEM used. Complete tomographic images should be acquired by rotating the sample tilt angle over a range of more than absolute value of 80 deg otherwise the CT images lose their correct structures. In order to constrain the origin and formation process of GEMS grains more clearly, we performed complete electron tomography for GEMS grains. Here we report the sample preparation method we have developed for this study, and the preliminary results.

Matsuno, J.↗

Sparse Matrix-Based HPC Tomography

Tomographic imaging has benefited from advances in X-ray sources, detectors and optics to enable novel observations in science, engineering and medicine. These advances have come with a dramatic increase of input data in the form of faster frame rates, larger fields of view or higher resolution, so high performance solutions are currently widely used for analysis. Tomographic instruments can vary significantly from one to another, including the hardware employed for reconstruction: from single CPU workstations to large scale hybrid CPU/GPU supercomputers. Furthermore, flexibility on the software interfaces and reconstruction engines are also highly valued to allow for easy development and prototyping. This paper presents a novel software framework for tomographic analysis that tackles all aforementioned requirements. The proposed solution capitalizes on the increased performance of sparse matrix-vector multiplication and exploits multi-CPU and GPU reconstruction over MPI. Furthermore, the solution is implemented in Python and relies on CuPy for fast GPU operators and CUDA kernel integration, and on SciPy for CPU sparse matrix computation. As opposed to previous tomography solutions that are tailor-made for specific use cases or hardware, the proposed software is designed to provide flexible, portable and high-performance operators that can be used for continuous integration at different production environments, but also for prototyping new experimental settings or for algorithmic development. The experimental results demonstrate how our implementation can even outperform state-of-the-art software packages used at advanced X-ray sources worldwide.

97 MATHEMATICS AND COMPUTING↗

Optical Performance Modeling of FUSE Telescope Mirror

We describe the Metrology Data Processor (METDAT), the Optical Surface Analysis Code (OSAC), and their application to the image evaluation of the Far Ultraviolet Spectroscopic Explorer (FUSE) mirrors. The FUSE instrument - designed and developed by the Johns Hopkins University and launched in June 1999 is an astrophysics satellite which provides high resolution spectra (lambda/Delta(lambda) = 20,000 - 25,000) in the wavelength region from 90.5 to 118.7 nm The FUSE instrument is comprised of four co-aligned, normal incidence, off-axis parabolic mirrors, four Rowland circle spectrograph channels with holographic gratings, and delay line microchannel plate detectors. The OSAC code provides a comprehensive analysis of optical system performance, including the effects of optical surface misalignments, low spatial frequency deformations described by discrete polynomial terms, mid- and high-spatial frequency deformations (surface roughness), and diffraction due to the finite size of the aperture. Both normal incidence (traditionally infrared, visible, and near ultraviolet mirror systems) and grazing incidence (x-ray mirror systems) systems can be analyzed. The code also properly accounts for reflectance losses on the mirror surfaces. Low frequency surface errors are described in OSAC by using Zernike polynomials for normal incidence mirrors and Legendre-Fourier polynomials for grazing incidence mirrors. The scatter analysis of the mirror is based on scalar scatter theory. The program accepts simple autocovariance (ACV) function models or power spectral density (PSD) models derived from mirror surface metrology data as input to the scatter calculation. The end product of the program is a user-defined pixel array containing the system Point Spread Function (PSF). The METDAT routine is used in conjunction with the OSAC program. This code reads in laboratory metrology data in a normalized format. The code then fits the data using Zernike polynomials for normal incidence systems or Legendre-Fourier polynomials for grazing incidence systems. It removes low order terms from the metrology data, calculates statistical ACV or PSD functions, and fits these data to OSAC models for the scatter analysis. In this paper we briefly describe the laboratory image testing of FUSE spare mirror performed in the near and vacuum ultraviolet at John Hopkins University and OSAC modeling of the test setup performed at NASA/GSFC. The test setup is a double-pass configuration consisting of a Hg discharge source, the FUSE off-axis parabolic mirror under test, an autocollimating flat mirror, and a tomographic imaging detector. Two additional, small fold flats are used in the optical train to accommodate the light source and the detector. The modeling is based on Zernike fitting and PSD analysis of surface metrology data measured by both the mirror vendor (Tinsley) and JHU. The results of our models agree well with the laboratory imaging data, thus validating our theoretical model. Finally, we predict the imaging performance of FUSE mirrors in their flight configuration at far-ultraviolet wavelengths.

Saha, Timo T.↗