Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “tissue imaging”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Physical Models from Physical Templates Using Biocompatible Liquid Crystal Elastomers as Morphologically Programmable Inks For 3D Printing

Advanced manufacturing has received considerable attention as a tool for the fabrication of cell scaffolds however, finding ideal biocompatible and biodegradable materials that fit the correct parameters for 3D printing and guide cells to align remain a challenge. Herein, a photocrosslinkable smectic-A (Sm-A) liquid crystal elastomer (LCE) designed for 3D printing is presented, that promotes cell proliferation but most importantly induces cell anisotropy. The LCE-based bio-ink allows the 3D duplication of a highly complex brain structure generated from an animal model. Vascular tissue models are generated from fluorescently stained mouse tissue spatially imaged using confocal microscopy and subsequently processed to create a digital 3D model suitable for printing. The 3D structure is reproduced using a Digital Light Processing (DLP) stereolithography (SLA) desktop 3D printer. Synchrotron Small-Angle X-ray Diffraction (SAXD) data reveal a strong alignment of the LCE layering within the struts of the printed 3D scaffold. The resultant anisotropy of the LCE struts is then shown to direct cell growth. This study offers a simple approach to produce model tissues built within hours that promote cellular alignment.

3D cell culture↗

Mass Spectrometry Imaging of Bio‐oligomer Polydispersity in Plant Tissues by Laser Desorption Ionization from Silicon Nanopost Arrays

Abstract Mass spectrometry imaging (MSI) enables simultaneous spatial mapping for diverse molecules in biological tissues. Matrix‐assisted laser desorption ionization (MALDI) mass spectrometry (MS) has been a mainstream MSI method for a wide range of biomolecules. However, MALDI‐MSI of biological homopolymers used for energy storage and molecular feedstock is limited by, e.g., preferential ionization for certain molecular classes. Matrix‐free nanophotonic ionization from silicon nanopost arrays (NAPAs) is an emerging laser desorption ionization (LDI) platform with ultra‐trace sensitivity and molecular imaging capabilities. Here, we show complementary analysis and MSI of polyhydroxybutyric acid (PHB), polyglutamic acid (PGA), and polysaccharide oligomers in soybean root nodule sections by NAPA‐LDI and MALDI. For PHB, number and weight average molar mass, polydispersity, and oligomer size distributions across the tissue section and in regions of interest were characterized by NAPA‐LDI‐MSI.

Samarah, Laith Z.↗

Virus-Like Particle: Evolving Meanings in Different Disciplines

Virus-like particle (VLP) is a term that has been in use for about 80 years. Usually, VLP has meant a particle that is like a virus, generally by appearance, but without either proven or actual virus functionality. Initially VLP referred to particles seen in electron microscope images of tissues. More recently, VLP has come to mean other things to other researchers. A key divergence has been use of VLP in association with vaccine and biotechnology applications versus use of VLP in enumeration of viruses in environmental samples. To these viral ecologists, a VLP is a particle that is virus sized, has nucleic acid, and could be a functional virus. But to vaccine developers and biotechnology researchers a VLP instead is a viral structure that intentionally lacks a viral genome. Here, we look at the history of use of VLP, following changes in meaning as the technology to study VLPs changed.

59 BASIC BIOLOGICAL SCIENCES↗

Three-Dimensional Single-Molecule Localization Microscopy in Whole-Cell and Tissue Specimens

Super-resolution microscopy techniques are versatile and powerful tools for visualizing organelle structures, interactions, and protein functions in biomedical research. However, whole-cell and tissue specimens challenge the achievable resolution and depth of nanoscopy methods. We focus on three-dimensional single-molecule localization microscopy and review some of the major roadblocks and developing solutions to resolving thick volumes of cells and tissues at the nanoscale in three dimensions. These challenges include background fluorescence, system- and sample-induced aberrations, and information carried by photons, as well as drift correction, volume reconstruction, and photobleaching mitigation. We also highlight examples of innovations that have demonstrated significant breakthroughs in addressing the abovementioned challenges together with their core concepts as well as their trade-offs.

59 BASIC BIOLOGICAL SCIENCES↗

Systems and methods for increasing efficiency of ultrasound waveform tomography

Ultrasound tomography imaging methods for imaging a tissue medium with one or more ultrasound transducer arrays comprising a plurality of transducers, wherein said transducers comprise source transducers, receiving transducers. The methods include assigning a phase value or time delay to source transducers, exciting the transducers and calculating a search direction based on data relating to the excited transducers.

Huang, Lianjie↗

Methods for ultraviolet excitation microscopy of biological surfaces

Microscopy with Ultraviolet Surface Excitation (MUSE) for use in the classroom to enhance life sciences education and curricula, or for other applications, including without limtiation the operating room, other medical environments, research environments, and low resource environments. MUSE's suitability is based on multiple key factors including its simplicity of use, the incorporation of inexpensive hardware including LED illumination, and very basic tissue preparation. The ultraviolet excitation acts as passive optical sectioning confining the generated fluorescence signal to only a few micrometers below the tissue surface thus eliminating the out of focus signals. This facilitates image capture of tissue microstructure and organization from specimens at the intact or sliced surface arising from varying fluorophore concentration within the different cellular compartments. Although just the tissue auto fluorescence maybe used, image quality is enhanced with brief application of nontoxic fluorescent dyes to selectively highlight cellular compartments. Sample preparation is safe, efficient and familiar to students with basic chemistry or biology lab experience. Mixed-dye powders may be used to simplify translation of this method for educational, medical, research, low resource, and other settings.

Demos, Stavros G.↗

Are Phosphatidic Acids Ubiquitous in Mammalian Tissues or Overemphasized in Mass Spectrometry Imaging Applications?

Abstract Mass spectrometry imaging (MSI) is an invaluable tool for the spatial visualization of molecules in vivo. However, the question of whether observed annotations are endogenous or artificial (i. e., from in‐source fragmentation) is critical and has been largely unexplored in multimodal MSI. In matrix‐assisted laser desorption/ionization (MALDI)‐MSI datasets from researchers worldwide, PAs were found to represent up to 18 % of annotations in rat brain. Rat brain was additionally imaged here using nanospray desorption electrospray ionization (nano‐DESI), a softer ionization strategy. No PAs observed with MALDI were present in the nano‐DESI dataset. Further investigation strongly indicated lipid fragmentation to PAs for MALDI‐MSI, but not with nano‐DESI‐MSI. We finally extend this observation to the MALDI‐MSI analyses of human tissues, showing that PA annotations comprised up to 16 % of annotations. Therefore, this study shows that MSI annotations should be carefully interrogated, as in‐source fragmentation or modification of lipids may contribute substantially to false annotations and incorrect biological interpretations.

Vandergrift, Gregory W.↗

High-Frequency 3D Photoacoustic Computed Tomography Using an Optical Microring Resonator

3D photoacoustic computed tomography (3D-PACT) has made great advances in volumetric imaging of biological tissues, with high spatial-temporal resolutions and large penetration depth. The development of 3D-PACT requires high-performance acoustic sensors with a small size, large detection bandwidth, and high sensitivity. In this work, we present a new high-frequency 3D-PACT system that uses a microring resonator (MRR) as the acoustic sensor. The MRR sensor has a size of 80 μ m in diameter and was fabricated using the nanoimprint lithography technology. Using the MRR sensor, we have developed a transmission-mode 3D-PACT system that has achieved a detection bandwidth of ~23 MHz, an imaging depth of ~8 mm, a lateral resolution of 114 μ m, and an axial resolution of 57 μ m. We have demonstrated the 3D PACT’s performance on in vitro phantoms, ex vivo mouse brain, and in vivo mouse ear and tadpole. The MRR-based 3D-PACT system can be a promising tool for structural, functional, and molecular imaging of biological tissues at depths.

47 OTHER INSTRUMENTATION↗

Epidural anesthesia needle guidance by forward-view endoscopic optical coherence tomography and deep learning

Epidural anesthesia requires injection of anesthetic into the epidural space in the spine. Accurate placement of the epidural needle is a major challenge. To address this, we developed a forward-view endoscopic optical coherence tomography (OCT) system for real-time imaging of the tissue in front of the needle tip during the puncture. We tested this OCT system in porcine backbones and developed a set of deep learning models to automatically process the imaging data for needle localization. A series of binary classification models were developed to recognize the five layers of the backbone, including fat, interspinous ligament, ligamentum flavum, epidural space, and spinal cord. The classification models provided an average classification accuracy of 96.65%. During puncture, it is important to maintain a safe distance between the needle tip and the dura mater. Regression models were developed to estimate that distance based on the OCT imaging data. Based on the Inception architecture, our models achieved a mean absolute percentage error of 3.05% ± 0.55%. Overall, our results validated the technical feasibility of using this novel imaging strategy to automatically recognize different tissue structures and measure the distances ahead of the needle tip during the epidural needle placement.

60 APPLIED LIFE SCIENCES↗

EVAP: A two-photon imaging tool to study conformational changes in endogenous Kv2 channels in live tissues

A primary goal of molecular physiology is to understand how conformational changes of proteins affect the function of cells, tissues, and organisms. Here, we describe an imaging method for measuring the conformational changes of the voltage sensors of endogenous ion channel proteins within live tissue, without genetic modification. We synthesized GxTX-594, a variant of the peptidyl tarantula toxin guangxitoxin-1E, conjugated to a fluorophore optimal for two-photon excitation imaging through light-scattering tissue. We term this tool EVAP (Endogenous Voltage-sensor Activity Probe). GxTX-594 targets the voltage sensors of Kv2 proteins, which form potassium channels and plasma membrane–endoplasmic reticulum junctions. GxTX-594 dynamically labels Kv2 proteins on cell surfaces in response to voltage stimulation. To interpret dynamic changes in fluorescence intensity, we developed a statistical thermodynamic model that relates the conformational changes of Kv2 voltage sensors to degree of labeling. We used two-photon excitation imaging of rat brain slices to image Kv2 proteins in neurons. We found puncta of GxTX-594 on hippocampal CA1 neurons that responded to voltage stimulation and retain a voltage response roughly similar to heterologously expressed Kv2.1 protein. Our findings show that EVAP imaging methods enable the identification of conformational changes of endogenous Kv2 voltage sensors in tissue.

59 BASIC BIOLOGICAL SCIENCES↗

Rapid Automated Annotation and Analysis of N-Glycan Mass Spectrometry Imaging Data Sets Using NGlycDB in METASPACE

Imaging N-glycan spatial distribution in tissues using mass spectrometry imaging (MSI) is emerging as a promising tool in biological and clinical applications. However, there is currently no high throughput tool for visualization and molecular annotation of N-glycans in MSI data, which significantly slows down data processing and hampers the applicability of this approach. In this work, we present how METASPACE, an open-source cloud engine for molecular annotation of MSI data, can be used to automatically annotate, visualize, analyze, and interpret high-resolution mass spectrometry-based spatial N-glycomics data. METASPACE is an emerging tool in spatial metabolomics, but the lack of compatible glycan databases has limited its application for comprehensive N-glycan annotations from MSI datasets. We created NGlycDB, a public database of N-glycans, by adapting available glycan databases. We demonstrate the applicability of NGlycDB in METASPACE by analyzing MALDI-MSI data from formalin-fixed paraffin-embedded (FFPE) human kidney and mouse lung tissue sections. We added NGlycDB to METASPACE for public use, thus facilitating applications of MSI in glycobiology.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Applying Multimodal Mass Spectrometry to Image Tumors Undergoing Ferroptosis Following In Vivo Treatment with a Ferroptosis Inducer

Epithelial ovarian cancer (EOC) is the most common form of ovarian cancer. The poor prognosis generally associated with this disease has led to the search for improved therapies such as ferroptosis-inducing agents. Ferroptosis is a form of regulated cell death that is dependent on iron and is characterized by lipid peroxidation. Precise mapping of lipids and iron within tumors exposed to ferroptosis-inducing agents may provide insight into processes of ferroptosis in vivo and ultimately assist in the optimal deployment of ferroptosis inducers in cancer therapy. In this work, we present a method for combining matrix-assisted laser desorption/ionization (MALDI) mass spectrometry imaging (MSI) with secondary ion mass spectrometry (SIMS) to analyze changes in spatial lipidomics and metal composition, respectively, in ovarian tumors following exposure to a ferroptosis inducer. Tumors were obtained by injecting human ovarian cancer tumor-initiating cells into mice, followed by treatment with the ferroptosis inducer erastin. SIMS imaging detected iron accumulation in the tumor tissue, and sequential MALDI-MS imaging of the same tissue section displayed two chemically distinct regions of lipids. Additionally, one region was associated with the iron-rich area detected with SIMS, and the other region encompassed the remainder of the tissue section. Bulk lipidomics confirmed the lipid assignments putatively assigned from the MALDI-MS data. Overall, we demonstrate the ability of multimodal MSI to identify the spatial locations of iron and lipids in the same tissue section and associate these regions with clinical pathology.

60 APPLIED LIFE SCIENCES↗

Live cell imaging of cellular dynamics in poplar wood using computational cannula microscopy

This study presents significant advancements in computational cannula microscopy for live imaging of cellular dynamics in poplar wood tissues. Leveraging machine-learning models such as pix2pix for image reconstruction, we achieved high-resolution imaging with a field of view of 55µm using a 50µm-core diameter probe. Our method allows for real-time image reconstruction at 0.29 s per frame with a mean absolute error of 0.07. We successfully captured cellular-level dynamics in vivo , demonstrating morphological changes at resolutions as small as 3µm. We implemented two types of probabilistic neural network models to quantify confidence levels in the reconstructed images. This approach facilitates context-aware, human-in-the-loop analysis, which is crucial for in vivo imaging where ground-truth data is unavailable. Using this approach we demonstrated deep in vivo computational imaging of living plant tissue with high confidence (disagreement score ⪅0.2). This work addresses the challenges of imaging live plant tissues, offering a practical and minimally invasive tool for plant biologists.

Ingold, Alexander (ORCID:0009000752380016)↗

Hierarchical deep reinforcement learning reveals a modular mechanism of cell movement

Time-lapse images of cells and tissues contain rich information about dynamic cell behaviours, which reflect the underlying processes of proliferation, differentiation and morphogenesis. However, we lack computational tools for effective inference. Here we exploit deep reinforcement learning (DRL) to infer cell–cell interactions and collective cell behaviours in tissue morphogenesis from three-dimensional (3D) time-lapse images. We use hierarchical DRL (HDRL), known for multiscale learning and data efficiency, to examine cell migrations based on images with a ubiquitous nuclear label and simple rules formulated from empirical statistics of the images. When applied to Caenorhabditis elegans embryogenesis, HDRL reveals a multiphase, modular organization of cell movement. Imaging with additional cellular markers confirms the modular organization as a novel migration mechanism, which we term sequential rosettes. Furthermore, HDRL forms a transferable model that successfully differentiates sequential rosettes-based migration from others. Our study demonstrates a powerful approach to infer the underlying biology from time-lapse imaging without prior knowledge.

59 BASIC BIOLOGICAL SCIENCES↗

Monte Carlo Simulation and Reconstruction: Assessment of Myocardial Perfusion Imaging of Tracer Dynamics With Cardiac Motion Due to Deformation and Respiration Using Gamma Camera With Continuous Acquisition

Purpose: Myocardial perfusion imaging (MPI) with single photon emission computed tomography (SPECT) is routinely used for stress testing in nuclear medicine. Recently, our group extended its potential going from 3D visual qualitative image analysis to 4D spatiotemporal reconstruction of dynamically acquired data to capture the time variation of the radiotracer concentration and the estimated myocardial blood flow (MBF) and coronary flow reserve (CFR). However, the quality of reconstructed image is compromised due to cardiac deformation and respiration. The work presented here develops an algorithm that reconstructs the dynamic sequence of separate respiratory and cardiac phases and evaluates the algorithm with data simulated with a Monte Carlo simulation for the continuous image acquisition and processing with a slowly rotating SPECT camera. Methods: A clinically realistic Monte Carlo (MC) simulation is developed using the 4D Extended Cardiac Torso (XCAT) digital phantom with respiratory and cardiac motion to model continuous data acquisition of dynamic cardiac SPECT with slowly rotating gamma cameras by incorporating deformation and displacement of the myocardium due to cardiac and respiratory motion. We extended our previously developed 4D maximum-likelihood expectation-maximization (MLEM) reconstruction algorithm for a data set binned from a continuous list mode (LM) simulation with cardiac and respiratory information. Our spatiotemporal image reconstruction uses splines to explicitly model the temporal change of the tracer for each cardiac and respiratory gate that delineates the myocardial spatial position as the tracer washes in and out. Unlike in a fully list-mode data acquisition and reconstruction the accumulated photons are binned over a specific but very short time interval corresponding to each cardiac and respiratory gate. Reconstruction results are presented showing the dynamics of the tracer in the myocardium as it continuously deforms. These results are then compared with the conventional 4D spatiotemporal reconstruction method that models only the temporal changes of the tracer activity. Mean Stabilized Activity (MSA), signal to noise ratio (SNR) and Bias for the myocardium activities for three different target-to-background ratios (TBRs) are evaluated. Dynamic quantitative indices such as wash-in (K1) and wash-out (k2) rates at each gate were also estimated. Results: The MSA and SNR are higher with higher TBRs while biases were improved with higher TBRs to less than 10%. The correlation between exhalation-inhalation sequence with the ground truth during respiratory cycle was excellent. Our reconstruction method showed better resolved myocardial walls during diastole to systole as compared to the ungated 4D image. Estimated values of K1 and k2 were also consistent with the ground truth. Conclusion: The continuous image acquisition for dynamic scan using conventional two-head gamma cameras can provide valuable information for MPI. Our study demonstrated the viability of using a continuous image acquisition method on a widely used clinical two-head SPECT system. Our reconstruction method showed better resolved myocardial walls during diastole to systole as compared to the ungated 4D image. Precise implementation of reconstruction algorithms, better segmentation techniques by generating images of different tissue types and background activity would improve the feasibility of the method in real clinical environment.

60 APPLIED LIFE SCIENCES↗