SAMPA Based Streaming Readout Data Acquisition Prototype

We have assembled a small-scale streaming data acquisition system based on the SAMPA front-end ASIC. The 32-channel SAMPA chip was designed for the high-luminosity upgrade of the ALICE Time Projection Chamber (TPC) detector at the CERN Large Hadron Collider. The goals of the prototype system are to determine if the SAMPA chip is appropriate for use in detector systems at Jefferson Lab, and to gain experience with the hardware and software required to deploy streaming data acquisition systems in nuclear physics experiments. The 800 channel system is composed of components used in the ALICE TPC data acquisition upgrade. Five front-end cards (FEC) support five SAMPA chips each. SAMPA data streams on an FEC are concentrated into two high-speed (4.48 Gb/s) serial data streams by a pair Gigabit Transceiver ASICs (GBTx). These ten streams (44.8 Gb/s) are transmitted from the FECs over fibers to a PCIe based readout unit. The FPGA engine on the readout unit compresses data for transmission to a server via 100 Gb ethernet. Components on the FECs are radiation tolerant. High data rates can be handled. The system is by design scalable and thus provides a functional prototype for high-rate streaming readout at Jefferson Lab and the future Electron Ion Collider. We have made fundamental measurements (noise, linearity, time resolution) on the SAMPA ASIC. We have also coupled the readout system to a small Gas Electron Multiplier (GEM) detector and have studied its response to cosmic rays. A beam test of the system is planned.

ABBOTT, David↗

Event reconstruction in a liquid xenon Time Projection Chamber with an optically-open field cage

nEXO is a proposed tonne-scale neutrinoless double beta decay (0νββ) experiment using liquid 136 Xe (LXe) in a Time Projection Chamber (TPC) to read out ionization and scintillation signals. Between the field cage and the LXe vessel, a layer of LXe (“skin” LXe) is present, where no ionization signal is collected. Only scintillation photons are detected, owing to the lack of optical barrier around the field cage. Here, in this work, we show that the light originating in the skin LXe region can be used to improve background discrimination by 5% over previous published estimates. This improvement comes from two elements. First, a fraction of the γ-ray background is removed by identifying light from interactions with an energy deposition in the skin LXe. Then, background from 222 Rn dissolved in the skin LXe can be efficiently rejected by tagging the α decay in the 214 Bi- 214 Po chain in the skin LXe.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Ion Manipulation from Liquid Xe to Vacuum: Ba-Tagging for a nEXO Upgrade and Future 0 νββ Experiments

Neutrinoless double beta decay (0𝜈𝛽𝛽) provides a way to probe physics beyond the Standard Model of particle physics. The upcoming nEXO experiment will search for 0𝜈𝛽𝛽 decay in 136 Xe with a projected half-life sensitivity exceeding 10 28 years at the 90% confidence level using a liquid xenon (LXe) Time Projection Chamber (TPC) filled with 5 tonnes of Xe enriched to ∼90% in the 𝛽𝛽-decaying isotope 136 Xe. In parallel, a potential future upgrade to nEXO is being investigated with the aim to further suppress radioactive backgrounds and to confirm 𝛽𝛽-decay events. This technique, known as Ba-tagging, comprises extracting and identifying the 𝛽𝛽-decay daughter 136 Ba ion. One tagging approach being pursued involves extracting a small volume of LXe in the vicinity of a potential 𝛽𝛽-decay using a capillary tube and facilitating a liquid-to-gas phase transition by heating the capillary exit. The Ba ion is then separated from the accompanying Xe gas using a radio-frequency (RF) carpet and RF funnel, conclusively identifying the ion as 136 Ba via laser-fluorescence spectroscopy and mass spectrometry. Simultaneously, an accelerator-driven Ba ion source is being developed to validate and optimize this technique. The motivation for the project, the development of the different aspects, along with the current status and results, are discussed here.

a-tagging↗

Low-diffusion Xe-He gas mixtures for rare-event detection: electroluminescence yield

High pressure xenon Time Projection Chambers (TPC) based on secondary scintillation (electroluminescence) signal amplification are being proposed for rare event detection such as directional dark matter, double electron capture and double beta decay detection. The discrimination of the rare event through the topological signature of primary ionisation trails is a major asset for this type of TPC when compared to single liquid or double-phase TPCs, limited mainly by the high electron diffusion in pure xenon. Helium admixtures with xenon can be an attractive solution to reduce the electron diffusion significantly, improving the discrimination efficiency of these optical TPCs. We have measured the electroluminescence (EL) yield of Xe-He mixtures, in the range of 0 to 30% He and demonstrated the small impact on the EL yield of the addition of helium to pure xenon. For a typical reduced electric field of 2.5 kV/cm/bar in the scintillation region, the EL yield is lowered by ~ 2%, 3%, 6% and 10% for 10%, 15%, 20% and 30% of helium concentration, respectively. This decrease is less than what has been obtained from the most recent simulation framework in the literature. The impact of the addition of helium on EL statistical fluctuations is negligible, within the experimental uncertainties. The present results are an important benchmark for the simulation tools to be applied to future optical TPCs based on Xe-He mixtures.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Design and production of the high voltage electrode grids and electron extraction region for the LZ dual-phase xenon time projection chamber

The dual-phase xenon time projection chamber (TPC) is a powerful tool for direct-detection experiments searching for WIMP dark matter, other dark matter models, and neutrinoless double-beta decay. Successful operation of such a TPC is critically dependent on the ability to hold high electric fields in the bulk liquid, across the liquid surface, and in the gas. Careful design and construction of the electrodes used to establish these fields is therefore required. We present the design and production of the LUX-ZEPLIN (LZ) experiment's high-voltage electrodes, a set of four woven mesh wire grids. Grid design drivers are discussed, with emphasis placed on design of the electron extraction region. Here, we follow this with a description of the grid production process and a discussion of steps taken to validate the LZ grids prior to integration into the TPC.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The electronic set-up for the scintillation light detection system of ICARUS-SBN at Fermilab

The ICARUS-T600 Liquid Argon (LAr) Time Projection Chamber (TPC) is presently used as the far detector of the Short Baseline Neutrino (SBN) program at Fermilab (USA) to search for a possible sterile neutrino signal with the Booster Neutrino Beam (BNB). We discuss a light detection system, based on 360 Hamamatsu R5912-MOD Photo-Multiplier Tubes (PMTs), which has been realized to detect vacuum ultraviolet (VUV) photons produced after the passage of ionizing particles in LAr. High performance electronics allows recording of the PMT signals and provides a fast discrimination for the exploitation of the scintillation light for trigger purposes. This system is fundamental for the TPC operation, contributing to the trigger system and for the 3D reconstruction of events.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Fast spark-detection system for GEM detectors

The sPHENIX experiment is currently under commissioning at the Relativistic Heavy Ion Collider (RHIC) at Brookhaven National Lab (BNL). The Time Projection Chamber (TPC) serves as a tracking detector for the experiment. The sPHENIX TPC uses a stack of four Gas Electron Multipliers (GEMs) as a gain stage in a reduced ion back-flow configuration. To mitigate the damaging effects of sparks in the GEMs, an online spark monitoring system was created. Once the system detects a spark in a GEM stack, the voltages across the GEMs in that stack can be lowered to prevent further sparking without affecting the gain and efficiency of the other modules. Spark signals are coupled out of the GEM stack by a pick-off capacitor attached to the bottom of the bottom GEM. Custom PCBs convert the oscillatory spark signal into a mono-polar pulse that is then digitized. The software then saves the waveform in a server and uses experimentally derived thresholds to determine how to react. As a result, the system has so far proven to be effective at improving the stability of the TPC and preventing damaging events while collecting cosmic ray data.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Precision measurements on oxygen formation in stellar helium burning with gamma-ray beams and a Time Projection Chamber

The carbon/oxygen (C/O) ratio at the end of stellar helium burning is the single most important nuclear input to stellar evolution theory. However, it is not known with sufficient accuracy, due to large uncertainties in the cross-section for the fusion of helium with 12 C to form 16 O, denoted as 12 C( α , γ ) 16 O. Here we present results based on a method that is significantly different from the experimental efforts of the past four decades. With data measured inside one detector and with vanishingly small background, angular distributions of the 12 C( α , γ ) 16 O reaction were obtained by measuring the inverse 16 O( γ , α ) 12 C reaction with gamma-beams and a Time Projection Chamber (TPC) detector. We agree with current world data for the total reaction cross-section and further evidence the strength of our method with accurate angular distributions measured over the 1 - resonance at E cm ~2.4 MeV. Our technique promises to yield results that will surpass the quality of the currently available data.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Experimental spectrum averaged cross sections (SACS) in 252 Cf(sf) neutron field and its impact on the evaluation of neutron standards

A new evaluation of spectrum averaged cross sections (SACS) of 235 U, 238 U, and 239 Pu measured in the 252 Cf(sf) reference neutron field is presented and found to be consistent with the original Mannhart SACS evaluation in IRDF-2002. The comprehensive vetted experimental database that includes SACS ratio and absolute SACS measurements of major actinides is being used to update the SACS database employed as input of the new GMApy code to derive the Neutron Standards. An update of the current neutron standards based on Time Projection Chamber (TPC) shape data, a new comprehensive uncertainty quantification, and revised SACS experimental database is proposed which result in a 0.7% increase of the evaluated 239 Pu(n,f)/ 235 U(n,f) crosssection ratio in the 1–5 MeV energy region. The increase is due to a 0.3% reduction of the standard 235 U(n,f) cross section and a 0.4% increase of the 239 Pu(n,f) reference cross section in the 1–5 MeV energy region. Those changes are well within estimated USU fission cross-section uncertainties of 1.2%, but are relevant for the evaluated mean values.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

sPHENIX Highlights: First Results from sPHENIX at RHIC

First results from the sPHENIX experiment on the π 0 v 2 and dE T =dη in Au+Au collisions at $\sqrt{s_{NN}}$ = 200 GeV using detector commissioning data during the RHIC 2023 Run are presented. These results are shown across a large centrality range, and compared to previous PHENIX and STAR results. These measurements demonstrate the sPHENIX capabilities towards accomplishing the sPHENIX jet physics program. From the ongoing RHIC 2024 Run, p + p collisions at $\sqrt{s}$ = 200 GeV, a first glimpse of the measurements K S 0 and Λ 0 obtained by the sPHENIX Time Projection Chamber (TPC) detector are shown.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Neutrino identification with scintillation light in MicroBooNE

MicroBooNE is a neutrino experiment which employs a liquid argon (LAr) time projection chamber (TPC) to record neutrino interactions from Fermilab's neutrino beamlines. The experiment's primary objective is to study low-energy νe interactions from the Booster Neutrino Beamline (BNB). Located on the surface, the detector is affected by a continuous rate of cosmic-rays. This leads to one neutrino interaction for every 104 cosmic rays observed in the TPC, making it difficult to isolate neutrino interactions in the detector using charge alone. MicroBooNE's trigger makes use of prompt scintillation light and plays an essential role in both performing strong background rejection and significantly reducing data-rates. Furthermore, a series of novel techniques relying on scintillation light are used to isolate beam-induced activity. This document briefly presents MicroBooNE's scintillation-light based trigger and novel Flash-Matching pattern recognition techniques for cosmic-rejection. This work serves as the foundation of neutrino analyses in LArTPC detectors and is therefore of interest to the broader short- and long-baseline neutrino programs being launched at Fermilab.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Energy resolution of the LZ detector for high-energy electronic recoils

The LUX-ZEPLIN (LZ) detector is a dual-phase liquid xenon time projection chamber (TPC) installed at the Sanford Underground Research Facility (Lead, South Dakota) at a depth of 1478 meters. Although the main objective of LZ is the direct detection of dark matter, its low background environment allows for the search of other rare processes, such as the neutrinoless double beta decay of xenon isotopes 134 Xe and 136 Xe with the respective Q-values of 826 keV and 2458 keV. The sensitivity of the detector to these decays is directly determined by the energy resolution, which, in turn, is degraded by non-uniformities in detector response. In this work, we present a novel method to correct, in the data, the non-uniformity of the light collected by an array of photosensors in a scintillation detector. This method is based on the knowledge of the light response functions of individual photosensors. With these techniques, we report, at a very early phase of the detector operations, a state-of-the-art energy resolution (σ/μ) of (0.67 ± 0.01)% at 2614 keV for the fiducial volume of 5.6 tonnes of liquid xenon.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Muon energy reconstruction for applications in neutrino astronomy in the DUNE far detector

Abstract DUNE (Deep Underground Neutrino Experiment) is a proposed long-baseline neutrino oscillation experiment located in the United States. The main physics objectives of DUNE are to measure neutrino oscillations and interactions, search for nucleon decay, observe supernova neutrino bursts and beyond Standard Model (BSM) effects. The DUNE far detector will be located 4850 feet underground at the Sanford Underground Research Facility in Lead, South Dakota. It will house the world's largest liquid-argon time projection chambers (TPC). The DUNE far detector can detect high-energy leptons that arise from interactions of cosmogenic neutrinos and search for neutrinos originating from the decay of weakly-interactive massive particles (WIMPs) annihilations occurring inside the Sun. Selecting upward-going muons reduces the background from cosmic-ray muons. The muon energy is estimated from the electromagnetic showers accompanying the muon, a technique that allows energy reconstruction up to a few hundred TeV.

Instruments & Instrumentation↗

Evidence against the Efimov effect in 12 C from spectroscopy and astrophysics

Background: The Efimov effect is a universal phenomenon in physics whereby three-body systems are stabilized via the interaction of an unbound two-body subsystems. A hypothetical state in 12 C at 7.458-MeV excitation energy, comprising a loose structure of three α particles in mutual two-body resonance, has been suggested in the literature to correspond to an Efimov state in nuclear physics. The existence of such a state has not been demonstrated experimentally. Purpose: Using a combination of γ spectroscopy, charged-particle spectroscopy, and astrophysical rate calculations allowing for strict limits on the existence of such a state to been established here. Method: Using the combined data sets from two recent experiments, one with the TexAT (Texas Active Target) TPC (Time Projection Chamber) to measure α decay and the other with Gammasphere to measure γ decay of states in 12 C populated by 12 N and 12 B β decay, respectively, we achieve high sensitivity to states in close proximity to the α threshold in 12 C. Results: No evidence of a state at 7.458 MeV is seen in either data set. Using a likelihood method, the 95% confidence limit γ -decay branching ratio is determined as a function of the β-decay feeding strength relative to the Hoyle state. In parallel, calculations of the 3α reaction rate show the inclusion of the Efimov corresponds to a large increase in the reaction rate around 5 × 10 7 K. Conclusion: From decay spectroscopy—at the 95% confidence limit, the Efimov state cannot exist at 7.458 MeV with any γ-decay branching ratio unless the β strength is less than 0.7% of the Hoyle state. This limit is evaluated for a range of different excitation energies and the results are not favorable for existence of the hypothetical Efimov state in 12 C . Furthermore, the 3α reaction rate with the inclusion of a state between 7.43 and 7.53 MeV exceeds the rate required for stars to undergo the red giant phase.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Time projection chamber for GADGET II

The established Gaseous Detector with Germanium Tagging (GADGET) detection system is used to measure weak, low-energy 𝛽-delayed proton decays. It consists of the Gaseous Proton Detector equipped with a MICROMEGAS (MM) readout to detect protons and other charged particles calorimetrically, surrounded by the Segmented Germanium Array (SeGA) for high-resolution detection of prompt 𝛾 rays. To upgrade GADGET's Proton Detector to operate as a compact time projection chamber (TPC) for the detection, three-dimensional imaging and identification of low-energy 𝛽-delayed single- and multiparticle emissions mainly of interest to astrophysical studies. A new high granularity MM board with 1024 pads has been designed, fabricated, installed, and tested. A high-density data acquisition system based on generic electronics for TPCs (GET) has been installed and optimized to record and process the gas avalanche signals collected on the readout pads. The TPC's performance has been tested using a 220 Rn 𝛼-particle source and cosmic-ray muons. In addition, decay events in the TPC have been simulated by adapting the attpcroot data analysis framework. Furthermore, a novel application of two-dimensional convolutional neural networks for GADGET II event classification is introduced. The optimization of data throughput is also addressed. The GADGET II TPC is capable of detecting and identifying 𝛼 particles as well as measuring their track direction, range, and energy. The extracted energy resolution of the GADGET II TPC using P10 gas is about 5.4% at 6.288 MeV ( 220 Rn 𝛼 events), computed using charge integration. Based on a systematic simulation study, we estimated the detection efficiency of the GADGET II TPC for protons and 𝛼 particles, respectively. It has also been demonstrated that the GADGET II TPC is capable of tracking minimum-ionizing particles (i.e., cosmic-ray muons). From these measurements, the electron drift velocity was measured under typical operating conditions. In addition to being one of the first generation of micropattern gaseous detectors (MPGDs) to utilize a resistive anode applied to low-energy nuclear physics, the GADGET II TPC will also be the first TPC surrounded by a high-efficiency array of high-purity germanium 𝛾-ray detectors. As a result, the TPC of GADGET II has been designed, fabricated, and tested and is ready for operation at the Facility for Rare Isotope Beams for radioactive-beam-line experiments.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Nuclear Recoil Calibration at Sub-keV Energies in LUX and Its Impact on Dark Matter Search Sensitivity

Dual-phase xenon time projection chamber (TPC) detectors offer heightened sensitivities for dark matter detection across a spectrum of particle masses. To broaden their capability to low-mass dark matter interactions, we investigated the light and charge responses of liquid xenon (LXe) to sub-keV nuclear recoils. Using neutron events from a pulsed Adelphi Deuterium-Deuterium neutron generator, an in situ calibration was conducted on the LUX detector. We demonstrate direct measurements of light and charge yields down to 0.45 keV and 0.27 keV, respectively, both approaching single quanta production, the physical limit of LXe detectors. Furthermore, these results hold significant implications for the future of dual-phase xenon TPCs in detecting low-mass dark matter via nuclear recoils.

Dark matter detectors↗

Constraints on directionality effect of nuclear recoils in a liquid argon time projection chamber

The direct search for dark matter in the form of weakly interacting massive particles (WIMP) is performed by detecting nuclear recoils produced in a target material from the WIMP elastic scattering. The experimental identification of the direction of the WIMP-induced nuclear recoils is a crucial asset in this field, as it enables unmistakable modulation signatures for dark matter. The Recoil Directionality (ReD) experiment was designed to probe for such directional sensitivity in argon dual-phase time projection chambers (TPC), that are widely considered for current and future direct dark matter searches. The TPC of ReD was irradiated with neutrons at the INFN Laboratori Nazionali del Sud. Data were taken with nuclear recoils of known directions and kinetic energy of 72 keV, which is within the range of interest for WIMP-induced signals in argon. The direction-dependent liquid argon charge recombination model by Cataudella et al. was adopted and a likelihood statistical analysis was performed, which gave no indications of significant dependence of the detector response to the recoil direction. The aspect ratio R of the initial ionization cloud is $R < 1.072$ with 90 % confidence level.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Production, quality assurance and quality control of the SiPM Tiles for the DarkSide-20k Time Projection Chamber

The DarkSide-20k dark matter direct detection experiment will employ a 21 m 2 silicon photomultiplier (SiPM) array, instrumenting a dual-phase 50 tonnes liquid argon Time Projection Chamber (TPC). SiPMs are arranged into modular photosensors called Tiles, each integrating 24 SiPMs onto a printed circuit board (PCB) that provides signal amplification, power distribution, and a single-ended output for simplified readout. Tiles are further grouped into Photo-Detector Units (PDUs). This paper details the production of the Tiles and the Quality Assurance and Quality Control (QA-QC) protocol established to ensure their performance and uniformity. The production and QA-QC of the Tiles are carried out at Nuova Officina Assergi (NOA), an ISO-6 clean room facility at LNGS. This process includes wafer-level cryogenic characterisation, precision die attaching, wire bonding, and extensive electrical and optical validation of each Tile. The overall production yield exceeds 83.5%, matching the requirements of the DarkSide-20k production plan. These results validate the robustness of the Tile design and its suitability for operation in a cryogenic environment.

Acerbi, F. [Fondazione Bruno Kessler]↗