Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “three-phase converter”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Per-Phase Control for CHB Converters with Negative-Sequence Current and DC Voltage Balancing Control

This paper presents a per-phase controller for a grid-connected Cascaded H-Bridge (CHB) converter featuring negative sequence current regulation and DC bus voltage balancing capabilities. Unlike conventional three-phase controllers, each phase of the CHB can be separately and controlled to regulate the DC voltage and reactive power flow. per-phase negative sequence current control strategy is incorporated into the proposed controller to ensure compliance with IEEE Standard 2800-2022, which requires the absorption of negative-sequence reactive current during grid voltage disturbances. Furthermore, a feed-forward control-based DC bus voltage balancing method is employed, which eliminates the need for the integrator commonly used in traditional approaches. The performance of the proposed controller is validated under various unbalanced grid scenarios and DC bus voltage imbalances through electromagnetic transient (EMT) simulation using a three-phase, three-level grid-connected CHB–Dual Active Bridge (DAB) converter testbed developed on MATLAB/Simulink. Additionally, the performance of the negative-sequence current regulation is investigated through simulation under different unbalanced grid voltage scenarios.

negative sequence current↗

Deep Learning-Based Dynamic Modeling of Three-Phase Voltage Source Inverters

Inverter-based resource (IBR) models are necessary to analyze modern power system stability and create effective control strategies. Modeling IBRs in converter-rich power systems is crucial, yet challenging due to the lack of commercial information on converter topologies and control parameters. This paper proposes novel convolutional neural network (CNN)–based data-driven techniques for modeling IBRs, addressing adaptability and proprietary concerns without requiring internal system physics knowledge. The proposed method is tested using real grid-tied commercial IBR transient data and demonstrates effectiveness and accuracy. Furthermore, the developed modeling approach is integrated and implemented in the open-source power distribution simulation and analysis tool, GridLAB-D, to illustrate the potentiality of dynamic analysis of large-scale power systems with high IBRs.

deep learning, artificial intelligence↗

Interleaved Cuk Converter Wave Energy System With Advanced Control and Grid Support Functions for Seamless Integration: Preprint

This paper presents an innovative wave energy conversion system employing an interleaved Cuk converter and advanced nonlinear control for seamless integration with the grid. The proposed system utilizes the interleaved Cuk converter for efficient power extraction on the DC side, while an inverter facilitates power transfer to the grid or load on the AC side. A sophisticated nonlinear control architecture based on Lyapunov energy functions ensures stable and optimal operation under varying wave conditions. Case study results demonstrate the effectiveness of the proposed system, highlighting its ability to efficiently harness wave energy and seamlessly integrate with the grid, thus paving the way for sustainable and reliable renewable energy generation. The overall system is verified via computer simulations based on MATLAB/Simulink and various case study results are presented.

HYDRO ENERGY,TIDAL AND WAVE POWER↗

Dynamic Validation of CNN-Based Surrogate Models for Inverter-Based Resources in Open-Source Solvers

Traditionally, distribution system planning has focused on steady-state analyses, with limited consideration of dynamic behavior. However, as large or medium-scale inverter-based resources (IBRs), particularly grid-following (GFL) inverters in commercial or industry buildings, become more prevalent, understanding their dynamic impact is essential for grid planning and operation. This article presents an innovative deep-learning (DL)-approach using convolutional neural networks technique to model the GFL inverters. Developed from real grid-tied commercial IBR transient data, these dynamic DL models overcome proprietary constraints by requiring minimal knowledge of internal converter physics while maintaining high accuracy and flexibility. To demonstrate their applicability, the models were incorporated into GridLAB-D, an open-source, three-phase distribution analysis tool. This integration enables dynamic simulations of large-scale distribution networks with high IBR penetration stability analysis. Rigorous testing and validation, aligned with industry standards, confirmed the reliability and efficiency of this approach, paving the way for enhanced planning and operational assessments of modern power systems.

Deep-learning↗

New Modulation and Impact of Transformer Leakage Inductance on Current-Source Solid-State Transformer

This article presents a novel modulation scheme for device voltage stress mitigation and comprehensive analysis of the impact of transformer leakage inductance in a current-source solid-state transformer (SST). Different from dual active bridge (DAB) SST, the operation of the current-source SST is similar to that of a flyback converter. The device bridge on only one side of the transformer is active to store energy into or release energy from the magnetizing inductance which acts as a current-source dc link. Such flyback operation with reverse-blocking switches can lead to additional device voltage stress and incomplete zero-voltage switching (ZVS) on the current-source soft-switching solid-state transformer (S4T) under conventional modulation. A new modulation scheme is proposed to address this issue. Moreover, different from the DAB, the leakage inductance of the medium-frequency transformer (MFT) in the S4T is a parasitic element similar to that in a matrix SST and can cause additional device voltage stress. Though the resonant capacitors, originally added to achieve ZVS, can absorb and recycle the leakage energy in the S4T, these capacitors need to be increased with larger leakage inductances to limit the voltage stress. However, large resonant capacitors can result in more lost duty cycles and reduced efficiency. The impact of such leakage inductance on device voltage stress is analyzed comprehensively, which is critical to guide future research and design of the S4T. Experimental results from S4T prototypes for DC-DC, multiport AC-DC, and AC-AC conversion with 1:1 and 4:1 MFT comprehensively verify the proposed concepts. Lastly, a case study of a three-phase AC-AC S4T over a power range from 1 kVA to 100 kVA each module reveals that the MFT leakage inductance should be less than 1% of the magnetizing inductance for safe operation.

14 SOLAR ENERGY↗

Modular Wide-bandgap String Inverters for Low-cost Medium-voltage Transformerless PV Systems

The proposed technology combines advances in wide-bandgap power electronics with breakthroughs in distributed and decentralized control to produce ultra-low-cost medium-voltage transformerless PV inverters that are composed of stackable lightweight blocks. Taken together, the proposed circuit designs and accompanying control strategies will yield integrated control+circuit (C2) blocks, each comprising a converter and local controller, that can be assembled in a modular fashion to obtain distributed conversion interfaces for next-generation commercial and utility-scale PV systems. We will utilize SiC devices to obtain C2 blocks that can individually operate at a voltage and power in excess of 1 kV and 100 kW, respectively, such that ensembles of series-connected blocks perform direct dc to three-phase ac conversion at medium voltages (e.g., 12 kV–35 kV) and at multi-MW power levels.

42 ENGINEERING↗

Single DC Source Based Cascaded Multilevel Inverter

The objective of this project is to develop a high-efficiency solid-state transformer that converts a fixed DC voltage to a medium-voltage AC for utility distribution network connections without having the conventional low-frequency bulky transformers and switch gears. The initial target of 99% efficiency was achieved with the use of wide bandgap semiconductor devices using a proposal novel multilevel inverter. The medium-voltage was successfully tested at 7.2/12.47 kV phase/line voltage level for a 100-kW three-phase inverter.

14 SOLAR ENERGY↗

Grid-Connected Self-Synchronous Cascaded H-Bridge Inverters with Autonomous Power Sharing: Preprint

Cascaded inverters are widely applied in applications where elevated ac voltages are required while using semiconductor devices with lower voltage ratings. Here, we focus on structures that require localized power transfer between low-voltage sources/loads dispersed across inverter dc links and the inverter ac-sides are series-connected across a three-phase medium-voltage ac grid. To date, decentralized controllers that allow for bi-directional power transfer in such systems are limited. To fill this gap, we propose a virtual oscillator controller which modulates the power processed by each inverter in a purely decentralized manner.

autonomous power sharing↗

A 50-kW Bidirectional Step-up / Step-down DC/DC Oak Ridge Converter for Wireless Charger Applications

This study presents a novel bidirectional concept by using Oak Ridge Converter (ORC) for wireless energy conversion (WEC) technologies such as wireless electric vehicle (EV) chargers, wireless mobile or energy storage systems (MESS / ESS), etc. The presented system can be deployed in a bidirectional wireless power transfer (WPT) structure for different input voltages by using two different operating frequencies. The proposed concept here achieves zero voltage switching (ZVS) in during step-up and step-down configurations. The system overall theoretical design and experimental test results are presented for 50 kW power transfer in both bidirectional operations modes. The laboratory demonstration of the system is presented for the three-phase bidirectional system with 6 inches of airgap between the coils and output of 560 VDC with 95.4% dc-to-dc efficiency.

Asa, Erdem↗

Robust Disturbance Rejection Rotor Current Control of Doubly-Fed Induction Generators

This article proposes a robust transient disturbance rejection current controller (TDRCC) to improve the transient performance of doubly-fed induction generators (DFIGs) in wind turbines during grid disturbances, such as short circuits. Here, the proposed robust TDRCC replaces the proportional-integral-derivative (PID) current controllers conventionally used in the vector control scheme of the DFIG rotor side converter (RSC). The TDRCC estimates the transient disturbances caused by grid faults or other external disturbances and provides compensation to the DFIG rotor voltage in the current control loops of the RSC to improve the robustness of the controller to disturbance. A sliding-mode current controller (SMCC) is also designed to highlight the transient performance improvement of the DFIG using the TDRCC over the state-of-the-art control methods during grid short circuit faults. Simulation studies are conducted in PSCAD/EMTDC for a 3.6-MW DFIG wind turbine with the proposed TDRCC, the conventional PI controller, and the SMCC, respectively during the most severe balanced three-phase grid short circuit fault specified by the U.S. grid code as well as an unbalance single-phase grid short circuit fault. Hardware experiments are conducted on a 200-W DFIG wind turbine emulator with the three different controllers for the same three-phase short circuit fault. Simulation and hardware experiment results show that the TDRCC reduces the peak rotor current significantly when compared with the PI and SMCC controlled DFIG system and, therefore, would help prolong the lifespan of the DFIG's power electronics and reduce maintenance costs.

42 ENGINEERING↗

Spacetime pq theory for AC and DC electric power systems

The 50/60 Hz alternating current (AC) electric power has been the standard and most flexible energy source powering our modern societies for one and a half centuries since the war of the currents: AC versus direct current (DC). A reactive power concept that was introduced at the beginning of the AC power was very useful for circuit/system analysis, design, control, optimization, and ultimately for more efficient and stable generation, transmission, distribution, and consumption. The initial reactive power theory was based on single-phase sinusoidal AC power to capture inductive and capacitive power that yields to net-zero average power over one fundamental cycle. Soon it was expanded to non-sinusoidal AC power and finally to instantaneous three-phase AC power. However, these reactive power theories remain separate and limited to special cases and have never been consolidated and made valid to all cases. Today, more widespread adoption of power electronics and renewable energy is bringing back DC power into the electric grids. The reactive power concept has never been applied to DC power systems. There is no reactive power in DC power systems according to the existing reactive power theories. Do DC power systems really have no reactive power? Capacitors and inductors are widely used in DC just like in AC power systems. Are they not reactive power components? Why are they different from their AC counterparts? Furthermore, are batteries active or reactive power components? What about active devices like power converters (or inverters) with AC (or DC) on one side and DC (or AC) on the other? Do they generate or consume reactive power? Finally, what about AC and DC hybrid power systems? How to define reactive power in such a complex power system that has a multitude of loads, buses, and sources? Is there reactive power between any two loads, any two buses, or any two sources in a power system and what is the total reactive power in such a complex power system as a whole? As the motivation and goal of this paper to answer the above basic questions, to unify the existing AC reactive power theories and to ultimately provide theoretical and insightful guidance for system analysis, design, control, efficiency, optimization, and operation of complex power systems, a concept of spacetime (both spatial and temporal) active and reactive power (pq) theory—the spatiotemporal aspect of active and reactive power—is developed for both AC and DC power systems. The theoretical definitions and physical meanings of the spacetime reactive power will be developed, and real applications and thought experiments/cases/exercises will be explored and discussed. The developed mathematics to define the active (or real) and reactive (or imaginary) power— p and q respectively by dot (scalar) and cross (vector) products of multi-dimension spacetime vectors and time-space mapping principle/law can have some fundamental implications as well.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Comparing Synthetic Routes and Thermal Characteristics of Alternate APO Variants

Low density, high-strength, temperature-resistant foams see widespread application in the aerospace and weapons fields due to their excellent qualities as structural supports. In these demanding environments, the most common formulation is a three-phase syntactic foam containing APOCure-601, BMI, and carbon or glass microballoons. Of these, APOCure-601 and BMI form the polymer resin amino-poly(oxadiazole) bismaleimide (APO-BMI), also known as Legacy APO or S-1,2-Ethyl-APO. In manufacturing this foam, the selective laser sintering (SLS) additive manufacturing technique is quickly gaining prominence, over more traditional injection molding since SLS allows for 3D printing of materials and reduces overall cost and waste production. That said, SLS also requires a narrow window between the melt and cure temperatures for a successful print. SLS printing of APO-BMI is therefore difficult since the compound possesses a broad window between its melting and curing temperatures, and also requires several post-cure steps or complete polymerization. This work explores synthesis optimization and thermal characteristics for variant Apo-BMI structures by observing the effect that alternative heteroatoms in the APO linkages, geometries 0f the BMI groups, and bridge structure identities impart on the resultant material. Synthetic methods for these altered structures were established in batch, with some others further converted to continuous flow chemistry, a method that produces materials in a continuous stream and is highly reproducible and readily scaled. Additionally, each structural change significantly altered the melt and cure properties for each APO variant, which is advantageous for SLS manufacturing.

60 APPLIED LIFE SCIENCES↗

Upgrading Biogas through in situ Conversion of Carbon Dioxide to Biomethane in Anaerobic Digesters

Organic waste streams generated by wastewater treatment plants, agricultural operations, and food processing industries represent an important yet underutilized opportunity for renewable energy production in the United States. Through anaerobic digestion, these waste streams can produce biogas, a mixture primarily composed of methane (CH4) and carbon dioxide (CO2), that can be upgraded to pipeline-quality natural gas. However, most existing upgrading technologies remove CO2 from biogas rather than utilizing it, leaving a significant portion of the potential energy unused. This project investigates a novel biological upgrading approach that converts CO2 into additional CH4 by supplying hydrogen (H2) to specialized microorganisms capable of performing hydrogenotrophic methanation. The main challenges associated with biological biogas upgrading are related to hydrogen supply, gas-liquid mass transfer, and process stability. First, due to the high cost of hydrogen gas, it is preferable that H2 be produced on-site using renewable energy sources such as wind or solar power. Second, hydrogen has low solubility in liquids, which limits its availability to microorganisms and requires strategies to improve gas dissolution and transfer within the reactor. Third, process inhibition may occur as a result of increased pH caused by CO2 consumption or elevated H2 partial pressure, both of which can negatively affect methanogenic activity. Although research in these areas has advanced during the course of this project, these challenges have not yet been fully resolved. To date, the biological systems that have achieved the highest methane concentrations are typically ex-situ reactors, where operational conditions can be more easily controlled. For this reason, the findings of the present project remain highly relevant. The project goal was to develop an innovative system that can accomplish biogas upgrading via biological conversion of CO2 to CH4, in a novel hybrid approach that combines the advantages of both in-situ and ex-situ systems. The proposed system employs a three-phase upflow anaerobic bioreactor with H2 delivery through a gas-permeable membrane, enabling efficient hydrogen transfer and microbial conversion. Under optimized operating conditions, the system achieved 99% H2 consumption and 90% CO2 conversion. A subsequent gas cleaning stage was implemented to further improve gas quality and meet target purity standards. The upgraded gas composition reached 97.7% CH4, 2.2% CO2, and 0.97% O2, while H2S concentrations remained below detection limits. In addition, a flue gas-driven inorganic thermoelectric generator (TEG) system was designed and experimentally validated as a potential source of electricity for H2 production. The system consisted of six TEG modules connected in series and achieved an open-circuit voltage of 4.5 V and a maximum power output of 224 mW at a temperature difference of approximately 53.5 °C, demonstrating effective conversion of waste heat into electrical power under simulated flue gas conditions. Finally, a comprehensive techno-economic analysis was completed to evaluate the capital and operating costs associated with the proposed system. The results provide important insights to guide future scale-up, optimization, and potential deployment of integrated biological biogas upgrading technologies.

09 BIOMASS FUELS↗

Open-circuit submodule fault diagnosis in MMCs using support vector machines

Series connection of semiconductor submodules (SM) in a modular multilevel converter (MMC) makes the MMC prone to open-circuit (OC) IGBT failures inside SMs. If left undetected, these faults degrade the operation of the MMC and lead to its instability. This article proposes a method to detect, localise, and classify single OC SM faults in an MMC using support vector machines (SVM) trained with data obtained from the capacitor voltage balancing block of the MMC control system. The proposed method relies on data extracted from the sorted capacitor voltage arrays of the upper and lower phase arms. Therefore, it does not require extra measurements and hardware. Additionally, it offers a fixed time for detecting and localising OC SM faults. This method is easy to implement as SVM has a simple decision function. Time-domain simulation case studies are performed on a three-phase nine-level MMC to evaluate the performance of the proposed method.

42 ENGINEERING↗

Fast and fault-tolerant model predictive control of MMCs under selective harmonic elimination

Selective harmonic elimination (SHE) is a suitable pulse-width modulation (PWM) tech-nique for some applications of modular multilevel converters (MMC) with lower numberof semiconductor submodules (SM). However, SHE can make it difficult to control circu-lating currents in the MMC. Moreover, the MMC is vulnerable to SM switch failures thatreduce its output power magnitude and quality. This paper proposes a fault-tolerant modelpredictive control strategy for MMCs operating with SHE (FT SHE-MPC). The effects ofswitch failure on phase voltage waveforms are studied first. Then, a method is proposedto design the FT SHE waveform to preserve its harmonic performance. Next, the pro-posed FT SHE-MPC is designed to increase the capacitor voltages during an SM failure tomaintain the fundamental component of the faulty phase voltage and control the circulat-ing currents, maintaining balance among line voltages and the output power of the MMC.Additionally, the proposed method offers as much as 60% faster FT transition time and asmuch as 36% lower capacitor voltage ripple. The advantages of the proposed method areverified through offline and real-time simulation studies on a three-phase nine-level MMCin PSCAD/EMTDC software and RTDS.

42 ENGINEERING↗

Modified Virtual Oscillator Based Operation of Grid Forming Converters with Single Voltage Sensor

Virtual oscillator based control architecture for grid forming converter with inner current control loop for additional objective accomplishments is proposed in this paper. In general, virtual oscillator is based on Lienard type of oscillator equation with a cubic nonlinearity. Virtual oscillator alone cannot accommodate unbalanced or harmonic mitigation while operating converters in grid forming mode. Therefore, to accomplish better tracking performance, incorporating the provision for nonlinear and/or unbalanced loads, an inner current control loop is utilized which is based upon Lyapunov energy function type control architecture due to its advantages. To reduce the overall cost of implementation and ensure proper phase difference in the generated voltages, the implemented virtual oscillator operates with only one voltage feedback from the point of common coupling as presented in this paper. To verify the effectiveness of the proposed approach, the overall system has been modeled in MATTLAB/Simulink and PLECS domain and case studies showing the successful production of low harmonic load voltages under nonideal loading condition along with other important results are presented in this paper.

dual second order generalized integrator↗

A Phase-Disposition PWM Enabled Model Predictive Control for a Nine-Level Inner-Interleaved Hybrid Multilevel Converter

This article brings forward a phase-disposition pulse width modulation enabled model predictive control (PDPWM-MPC) for a nine-level inner-interleaved hybrid multilevel converter (9L-IHMC). Firstly, three layers of virtual space vector diagrams (VSVD) are established based on the sign patterns of the original and virtual reference vectors in the abcframe, respectively, to achieve the phase-disposition pulse width modulation (PD-PWM) in a non-independent three-phase way. Then, three adjacent virtual vectors in the third-layer VSVD, together with their optimized duty cycles, are applied to guarantee the optimal current tracking. Finally, through the use of the duty cycle alternation approach, dc-link and floating capacitors voltages are balanced and circulating currents are mitigated as well. The proposed PDPWM-MPC can not only enable the decoupling of the low-and high-frequency stages in the 9L-IHMC, but also reduce both output current ripples and computational burden. In addition, it can achieve a constant equivalent switching frequency and address the disproportion of power losses associated with the PD-PWM. Here, both simulations and experiments on a silicon carbide device-based prototype substantiate the effectiveness of the proposed control strategy.

42 ENGINEERING↗