Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “thermal systems”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

A review on the sizing and selection of control valves for thermal hydraulics for reactor system applications

This study presents an overview regarding how to model/size, choose, and maintain control valves (CVs) for a reactor system thermal hydraulics experimentation—specifically simulating pipe break(s) and a loss of coolant accident (LOCA) analysis. In a thermal hydraulics test loop, CVs modulate fluid flow according to the control signal generated by the controller to control the process parameter. The selection of a CV in industrial applications involves many factors, including process diversity, safety, and reliability. Further, the key issues and challenges for performing proper mathematical modeling, installation, servicing, and calibration are also discussed for the benefit of operators and end-users. Additionally, this research includes case studies illustrating major plant-level accidents associated with the malfunctioning of valves. Therefore, the study will serve as a knowledge base or reference guide for young professionals and operators who wish to better understand process control applications.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Physics-constrained fault diagnosis framework for monitoring a multi-component thermal hydraulic system

A method for diagnosing faults includes receiving a system description of a thermal hydraulic system, the system description indicating a plurality of components and sensors. The method also includes constructing, based on physical conservations laws and using the system description, a plurality of physics-based models for the plurality of components, each of the plurality of physics-based models including unknown parameters. The method further includes receiving historical measurements and calibrating the physics-based models by calculating the unknown parameters of each of the physics-based models using the historical measurements to produce calibrated models. The method also includes receiving sensor measurements of the sensors, and calculating residuals corresponding to differences between measurements predicted by the plurality of calibrated models and the sensor measurements. The method also includes determining, based on the calculated residuals, a fault of a component or a sensor, and generating an alert indicating the fault.

Nguyen, Tat Nghia↗

Performance of Compact Pulsed Thermal Imaging System for In-Service Applications. Pulsed thermal tomography nondestructive examination of additively manufactured reactor materials and components

Additive manufacturing (AM) is an emerging method for cost-efficient fabrication of complex topology nuclear reactor parts from high-strength corrosion resistance alloys, such as stainless steel and Inconel. AM of metallic structures for nuclear energy applications is currently based on laser powder bed fusion (LPBF) process, which has the capability of melting metallic powder and net shaping the structures with relatively high precision. Some of the challenges with using LPBF method for nuclear manufacturing include the possibility of introducing pores into metallic structures. Integrity of AM structures needs to be evaluated nondestructively because material flaws could lead to premature failures due to creep in high temperature nuclear reactor environment. Currently, there exist limited capabilities to evaluate actual AM structures nondestructively. Pulsed Thermography (PT) imaging provides a capability for non-destructive evaluation (NDE) of sub-surface defects in arbitrary size structures. The PT method is based on recording material surface temperature transients with infrared (IR) camera following thermal pulse delivered on material surface with flash light. The PT method has advantages for NDE of actual AM structures because the method involves one-sided non-contact measurements and fast processing of large sample areas captured in one image. The data cube of PT measurements consists of surface temperature taken at sequential time intervals T(x,y,t). Material defects can be detected either by analyzing the thermograms T(x,y,t) data cube, or by using thermal tomography (TT) algorithm to obtain 3D spatial reconstruction of thermal effusivity e(x,y,z). To reduce the cost and enable in-service NDE in spatially constrained environment, it is highly desirable to develop PT with compact and inexpensive IR camera. Following initial qualification of an AM component for deployment in a nuclear reactor, a compact PT system can also be used for in-service nondestructive evaluation (NDE) applications. However, data cube obtained with PT based on compact IR camera suffers from strong thermal noises and loss of features due to relatively low sampling rate. In this report we describe two unsupervised machine learning (ML) algorithms for enhancement of PT images obtained with compact IR camera. In one approach, we introduce Sparse Coding Discrete Cosine Transform (SC/DCT) algorithm to remove additive white Gaussian noise (AWGN) from spatial thermal effusivity reconstructions. In another approach we introduce a Spatial Temporal Denoised Thermal Source Separation (STDTSS) ML algorithm to process thermograms. The STDTSS algorithm consists of spatial and temporal denoising using Gaussian and Savitzky–Golay filtering, followed by the matrix decomposition using Principal Component Analysis (PCA), and Independent Component Analysis (ICA) to automatically detect flaws. In the work described in this report, we constructed a compact PT system using a relatively small and low-cost FLIR A65 camera, consisting on uncooled microbolometer detector. Performance of SC/DCT algorithm was demonstrated on enhancing TT images of Inconel 718 AM plate. Performance of the STDTSS methods was investigated using thermography data obtained from imaging stainless steel 316L specimens produced with LPBF method with imprinted calibrated porosity defects.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Modular thermal energy storage system

A thermal energy storage (TES) system includes a plurality of closely packed TES modules, each TES module having a shell enclosing a plurality of sealed tubes that each contain a TES media. A computer-controlled flow control system includes a flow distributor, for example a flow distributor having a plenum configured to receive a heat transfer fluid (HTF), and a plurality of control valves controlled by the computer to controllably distribute the HTF from the plenum to the plurality of TES modules. Sensor data from the TES modules, for example temperature, pressure, and/or flow data, is provided to the computer. In some embodiments the plenum includes two or more compartments with separate HTF flow ports, which may be provided to the controller at different temperatures.

Wirz, Richard E.↗

Sierra Space Technology Collaboration-Advanced Manufacturing of Thermal Protection System Tiles for Space Plane Atmospheric Reentry

Thermal protection systems (TPS) constitute a major material, engineering, and manufacturing challenge for space access. Atmospheric re-entry generates very high heats and requires advanced materials to withstand such conditions. Combining the required materials and integrating them into the vehicle is a major engineering undertaking that often must use creative designs to accommodate the selected materials and systems. Likewise, the manufacture of TPS is costly and challenging; it requires a combination of materials in a range of complex and unique shapes with specialized process conditions. Compounding these challenges, for harsh re-entry profiles or on high heat flux regions of the vehicle, even state of the art TPS is effectively single use and thereby creating a strong economic incentive to improve the TPS materials, integration, and manufacture. This work focuses on the use of ceramic modifications to TPS materials thereby allowing multi flight capability.

99 GENERAL AND MISCELLANEOUS↗

An optimization framework for the network design of advanced district thermal energy systems

In this work, a topology optimization framework for district thermal energy systems is presented. The framework seeks to address the questions, for a given district, "What is the best subset of buildings to connect to a district thermal energy system, and by what network should they be connected, to minimize life cycle cost?" A particle swarm optimization approach is validated to address the selection of the subset of buildings, and a graph theory-based heuristic is validated for selection of the network topology for any candidate subset of buildings. The framework is applied to a prototypical urban district for illustrative purposes. Additionally, modeling of prototypical districts revealed reductions in source energy use intensity for heating and cooling of 21-25% through the use of advanced district energy systems relative to code-compliant, building level systems. The framework identifies solutions with life cycle cost values 14% to 72% lower than that of base case scenarios based on conventional design approaches, depending on the base case scenario selected. Analysis of the search space indicates that topology optimization facilitates reductions in life cycle cost, source energy use intensity, and carbon emissions.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Design and performance of a variable gap system for thermal conductivity measurements of high temperature, corrosive, and reactive fluids

We report high-temperature fluids such as molten salts, liquid metals, and gasses are being proposed for many advanced energy systems including thermal energy storage devices, concentrating solar plants, and advanced nuclear reactor designs. However, the chemical behavior and thermophysical properties of many of these fluids have not been well characterized, which hinders the design, modeling, safety analysis, and deployment of these systems. Thermal conductivity is a property that is especially limited by existing measurement capabilities, which are subject to errors caused by convection, material interaction, radiative heat transfer, and instrument degradation. Therefore, there is a lack of standard, systematic measurement techniques for high-temperature, reactive, and corrosive fluids. In this work, the development of a variable gap thermal conductivity measurement system is detailed. The system is designed to measure the thermal conductivity of highly corrosive and reactive fluids, and survive operation between 100 °C and 800 °C. The effects of convection are minimized by limiting the thickness of the specimen to thin sizes (<0.3 mm). Corrections for radiative heat transfer were included in the working equations to consider specimens with varying optical properties. The design, construction, instrumentation, operating principles, and data analysis techniques are discussed in detail. The system was tested up to 500 °C using helium gas and molten KNO 3 -NaNO 3 to verify the measurement technique and determine the sources of error. At 300 and 400 °C KNO 3 -NaNO 3 , results showed maximum relative error of 6% when compared to results in the literature. The helium results were within 13% of those in the literature at 300 and 400 °C. Higher errors were observed at 500 °C for both fluids, and the sources of these errors are discussed.

42 ENGINEERING↗

Methods and systems for thermal energy storage and their use in buildings applications

The present disclosure relates to particle-based thermal energy storage (TES) systems employed for the heating and cooling applications for residential and/or commercial buildings. Particle-based TES systems may store thermal energy in the particles during off-peak times (i.e., when electricity demand and/or costs are relatively low) and remove the stored thermal energy for heating or cooling applications for buildings during peak times (i.e., when electricity demand and/or costs are relatively high).

Ma, Zhiwen↗

Advanced Manufacturing of Thermal Protection System Tiles for Space Plane Atmospheric Reentry

Thermal protection systems (TPS) constitute a major material, engineering, and manufacturing challenge for space access. Atmospheric re-entry generates very high heats and requires advanced materials to withstand such conditions. Combining the required materials and integrating them into the vehicle is a major engineering undertaking that often must use creative designs to accommodate the selected materials and systems. Likewise, the manufacture of TPS is costly and challenging; it requires a combination of materials in a range of complex and unique shapes with specialized process conditions. Compounding these challenges, for harsh re-entry profiles or on high heat flux regions of the vehicle, even state of the art TPS is effectively single use and thereby creating a strong economic incentive to improve the TPS materials, integration, and manufacture. This work focuses on the use of ceramic modifications to TPS materials thereby allowing multi flight capability.

36 MATERIALS SCIENCE↗

Oscillating heat pipe integrated thermal management system for power electronics

Disclosed is a thermal management system for removing heat from a power electronic heat source, the system comprising: a base plate having a plurality of fluid passages there through and extending between and inlet side of the base plate and an outlet side of the base plate; and a plurality of heat transfer pipe segments respectively attached to one or more of the plurality of fluid passages at the inlet side of the base plate and the outlet side of the base plate, the plurality of heat transfer pipe segments arranged adjacent one another, the plurality of heat transfer pipe segments containing a two-phase working fluid, and the plurality of heat transfer pipe segments forming a continuous flow path through and back into the base plate for the two-phase working fluid.

Wang, Jim↗

Low-temperature solar thermal-power systems for residential electricity supply under various seasonal and climate conditions

In this work, the performance of low-temperature (<100 degrees C) solar thermal-power systems to satisfy residential electric loads was analyzed. The solar-driven system was designed to provide a fraction of the total electricity demand in a complementary operation with the electric grid. The analysis was conducted for an coperation during seven days each season, considering real solar and climate variables and residential loads at different climate zones in the United States. The efficiency of the system strongly depends on the solar radiation profile and the ambient temperature. Maximum efficiencies of around 9.5% were obtained in the cold and marine climate zones due to the high solar energy input and low heat dissipation temperatures. In these two zones, the system could supply more than 98% of the electricity demand all seasons. At mixed-humid and hot-humid regions, the system supplied around 50% of the electric load in three of the four seasons, but it only supplies about 27% of the electricity needs in the mixed-humid zone during summer and hot-humid zone during winter. The effect of the solar collector field area and the tank volume was also analyzed. In general, larger solar fields positively impact the efficiency. However, the impact of the tank volume varies depending on the solar radiation profile and the load requirements. Average efficiencies for the seven-day operation can be larger than 6% with a proper selection of the solar collector area and tank volume for an Organic Rankine Cycle with a capacity of about 2.6 kW. Finally, an economic analysis of the system was conducted, and the results were compared with a solar PV + battery system of similar capacity. It is expected that the cost for the analyzed solar-thermal system decreases in the coming years with the increased interest on low temperature applications.

14 SOLAR ENERGY↗

Performance Evaluation and Optimal Design Analysis of Continuous-Operation Solar-Driven Cooling Absorption Systems With Thermal Energy Storage

A solar absorption cooling system consisting of a flat plate collector, thermal energy storage tank, and absorption chiller is analyzed in this work. A dimensionless model is developed from the energy balance on each component and the chiller's characteristic performance curves. The model is used to determine the interaction and influence of different parameters such as tank size, solar collector area, chiller size, cooling load, cooling temperature, heat loss, and mass flow rates on the performance. From the analysis, smaller solar collector areas are required for lower cooling loads and smaller tank volumes. A specific cooling load of 1 x 10^-5 will require a specific solar collector area between two and six times larger, depending on the initial tank temperature, than the area required for a baseline system that considers typical commercial design and operation parameters. A similar behavior was observed for the specific tank volume. For the baseline system, the minimum specific area of the collector of 9.57 is achieved for an initial tank temperature of 1.19. For a cooling load of 1 x 10^-5, the optimum initial tank temperature will be 1.11 that results in a minimum specific solar collector area of 25.26. A specific tank volume of 4 x 10^-4 will also have an optimum initial tank temperature of 1.11 that minimizes the specific solar collector area to a value of 28.18. The approach and analysis in this work can be used to determine design parameters for solar absorption cooling systems based on a proper relation among system's dimensions to achieve optimum operation.

cooling load↗

Thermal energy storage system

A thermal energy storage (TES) component includes a shell having first and second ports, and at least a first set of thermally conductive sealed containers that contain a TES media for storing thermal energy. A first set of sealed tubes containing a first TES media are in a first section of the shell, and a second set of sealed tubes containing a different TES media are in a second section of the shell. Electric heating elements are immersed in at least some of the tubes, and may extend only from one end of the tube. In some embodiments more than one heating element is immersed in the TES media and positioned to enhance convective flow. In some embodiments electric heating elements are disposed externally on the sealed tubes. Some tubes are tapered or frustoconical, with heating elements provided in a larger-diameter portion of the tubes.

Wirz, Richard E.↗

Thermal Integration of DETAIL Systems

A thermal connection between the Microreactor AGile Non-nuclear Experimental Testbed (MAGNET) and the thermal energy distribution system (TEDS) has been a key part of the Dynamic Energy Transport and Integration Laboratory (DETAIL) plan since the development of the Integrated Energy Systems Roadmap in 2020. This connection provides an expanding demonstration capability for integrated system operations. The thermal connection between MAGNET and TEDS required the selection of a heat exchanger and valves to isolate flow. Research staff within the NEET Crosscutting Technology Development program selected equipment after receiving proposals from multiple vendors. A helical coil heat exchanger from Graham Corporation was selected for its small volume relative to its heat transfer surface area to fit in the limited space available. Triple offset butterfly valves with pneumatic actuators from Flowserve were selected to isolate and/or control flow of the hot gas through the heat exchanger. Staff from Idaho National Laboratory’s (INL) Facilities and Site Services Engineering department designed the piping and structural support. A mechanical construction firm was contracted to install the system. This report documents the design and construction of this thermal connection.

25 ENERGY STORAGE↗

Towards a Techno-Economic Analysis of PCM Integrated Hybrid HVAC Systems

Thermal end uses dominate building energy consumption and are a major driver of peak demand. As heating is electrified, peak electrical power required will surge, prompting a need for innovative HVAC system designs and controls.These designs must incorporate novel technologies at the component level and new integration techniques at the system level. One such possibility involves the addition of thermal energy storage (TES) in heating and cooling equipment using a phase change material (PCM) heat exchanger. Here, thermal energy storage via phase change can be used to shift the HVAC system loads to times of lower electricity cost, reduced carbon intensity, and greater energy efficiency. Most of the current utilization of PCM in buildings involves passive components. By actively controlling when heat is stored and released from PCM, we can optimize the building HVAC system to cost-effectively meet consumer needs with the flexibility to draw on renewable energy resources when they are abundant and available. While this combination of technologies is promising in theory, simulation-based evaluation of a prototype can be difficult due to the modeling requirements at the component level and the large number of possible configurations and operating modes at the system level. To conduct this evaluation, we use the Modelica language for modeling and simulation because it enables users to represent the important physics of the problem, interchange and rearrange components in an efficient manner, and implement a range of control configurations. In this work, we considered three case studies: a portable building, a large commercial retail store, and a multifamily residential apartment unit. Each of these employs a different system design, ranging from a single package vertical unit incorporating PCM to a central plant with independent heat pump, evaporative cooling, and thermal energy storage components. This paper describes the technologies in question, presents modeling at the component and system levels, and demonstrates building energy and demand charge cost savings with local time-of-use tariffs in a hot-dry climate.

Helmns, Dre↗

Hierarchical Bayesian modeling for Inverse Uncertainty Quantification of system thermal-hydraulics code using critical flow experimental data

The best estimate plus uncertainty methodology in nuclear system thermal-hydraulic studies necessitates a comprehensive understanding of uncertainties in system code predictions. The forward uncertainty quantification (UQ) process involves the propagation of input uncertainties through the computational models to obtain uncertainties in the outputs. To this end, achieving an accurate estimation of input uncertainties is important, which is the focus of inverse UQ (IUQ). Traditionally, research in Bayesian IUQ within the nuclear engineering domain has largely relied on single-level Bayesian inference. While being effective for relatively small datasets, this approach encounters limitations for cases with large datasets. The use of a single-level model may prove inefficient, as the resultant posterior distributions can significantly differ when distinct subsets of data are employed. To address this issue, we employ an hierarchical Bayesian model for IUQ. Furthermore, this approach involves organizing observations into different groups based on the test conditions, thereby accommodating varying calibration parameters across these distinct groups. In this study, we developed and implemented a hierarchical Bayesian IUQ method to consider the grouping effect of critical flow measurement data from various geometries. Comparing the outcomes of IUQ under different selections of test data using hierarchical Bayesian IUQ against those obtained from single-level Bayesian IUQ, the forward propagation of hierarchical Bayesian IUQ results demonstrates a notably improved agreement with the experimental data.

42 ENGINEERING↗

Thermal Management System for an Electric Machine With Additively Manufactured Hollow Conductors With Integrated Heat Pipes

Here, this paper discusses steps taken to develop a novel thermal management system for an aircraft propulsion electric machine containing additively manufactured coils integrated with heat pipes aimed at boosting its specific power. Experimental setups are used to size and characterize heat pipes for the application and 3D thermal finite element analysis is used to determine optimum heat transfer coefficient of the convective boundaries. For some of the convective boundaries, fin-based surface area enhancement is required to reach a target combined overall heat transfer coefficient and surface area performance (UA). This enhancement is worked out using a combination of the Engineering Equation Solver tool and 3D thermal FEA. The thermal management system's UA, and by extension its specific power, sensitivity to coolant temperature is explored. Temperature distribution plots of optimized machine components are also presented and discussed. Lastly, additional heat pipe testing is carried out to study its maximum heat transfer capability's sensitivity to condenser coolant temperature and configuration.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗