Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “thermal flexibility”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

A Multidisciplinary Approach to Integrated Energy Systems: Advanced Nuclear Plants with Thermal Storage for Dynamic and Flexible Operation in Diverse Markets

Energy supply, distribution, and demand are continuously evolving in accordance with the integration of new power generation sources. In the United States, there is a progressive shift toward incorporating fluctuating energy sources such as wind and solar into the energy mix, alongside the distributed generation. Simultaneously, we are seeing a revolution in consumer technologies such as electric vehicles, energy devices for both residential and commercial use, and industrial processes—all contributing to a fundamental change in energy consumption dynamics. These scenarios have led to huge demand for enhanced flexibility from nuclear power plants (NPPs), requiring them to operate with unprecedented adaptability. Furthermore, advanced NPPs (A-NPPs) could potentially apply to scenarios in which power generation flexibility is prioritized over its current and conventional baseload generation capacity for traditional demand patterns. The present work covers several configurations for coupling nuclear energy production with thermal energy storage (TES). Previous work evaluated systems entailing a simple nuclear-TES configuration that used steam as a heat source for the TES of three different advanced reactors (ARs), but its heat diversion ratio (HDR) for charging was limited. The present work proposes a new configuration that features full decoupling of the nuclear reactor and the power cycle, using reactor coolant (i.e., gas) as a heat source for the TES and offering a theoretically unlimited HDR. This configuration is, however, more complex, as both high- and low-temperature TES (HT-TES and LT-TES) systems are required in order to cover the extended temperature range. Although this configuration imposes certain limitations on the discharge system configuration, it also presents the opportunity to design a more efficient system. For this case in particular, a steam reheat cycle is advantageous. Conventional TES systems take advantage of nominal efficiency when discharging, whereas the reheat cycle in the fully decoupled TES system affords a significant efficiency increase over conventional cases. Material selection, component/equipment sizing, and costing analyses were performed, followed by economic dispatch and size optimization. Dynamic models were developed for the decoupled system in order to generate insights into aspects of off design operation (e.g., drops in cycle efficiency), and these models enable exploration of potential mitigation strategies for addressing such drops. The models also highlight the need to design fail-safes that ensure continuous operational stability and minimize the impact of power ramping on the reactor parameters.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

How Can Floor Covering Influence Buildings’ Demand Flexibility?

Although the thermal mass of floors in buildings has been demonstrated to help shift cooling load, there is still a lack of information about how floor covering can influence the floor’s load shifting capability and buildings’ demand flexibility. To fill this gap, we estimated demand flexibility based on the daily peak cooling load reduction for different floor configurations and regions, using EnergyPlus simulations. As a demand response strategy, we used precooling and global temperature adjustment. The result demonstrated an adverse impact of floor covering on the building’s demand flexibility. Specifically, under the same demand response strategy, the daily peak cooling load reductions were up to 20–34% for a concrete floor whereas they were only 17–29% for a carpet-covered concrete floor. This is because floor covering hinders convective coupling between the concrete floor surface and the zone air and reduces radiative heat transfer between the concrete floor surface and the surrounding environment. In hot climates such as Phoenix, floor covering almost negated the concrete floor’s load shifting capability and yielded low demand flexibility as a wood floor, representing low thermal mass. Sensitivity analyses showed that floor covering’s effects can be more profound with a larger carpet-covered area, a greater temperature adjustment depth, or a higher radiant heat gain. With this effect ignored for a given building, its demand flexibility would be overestimated, which could prevent grid operators from obtaining sufficient demand flexibility to maintain a grid. Our findings also imply that for more efficient grid-interactive buildings, a traditional standard for floor design could be modified with increasing renewable penetration.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Intermediate-Temperature Proton Exchange Membranes Based on Cerium Ultraphosphate Composited with Polybenzimidazole

This paper reports the rational fabrication and structural, thermal, mechanical and electrochemical characterization of a new type of intermediate-temperature (IT) polymer-inorganic composite (PIC) proton exchange membranes (PEMs) that are made of cerium ultraphosphate (CeP 5 O 14 —CUP) as the solid-state proton conductor composited with a high-temperature (HT) polybenzimidazole (PBI) as the polymeric binder. Here, flexible PBI-CUP PIC membranes with the thickness of ~135 μ m and CUP mass fraction of up to 75% were prepared by solution-casting without additional acid-doping (e.g., phosphoric acid). The proton conductivity of the fabricated IT-PIC-PEMs was up to 5.80 × 10 –2 S cm –1 as measured from a prototype IT PEM fuel cell (PEMFC) operated at 200 °C in the humidified hydrogen and air environment. This type of IT-PIC-PEMs also demonstrated sufficient mechanical strength and flexibility, excellent thermal stability (up to 350 °C), and very good durability of the proton conductivity (within the test duration of 500 h). The present experimental study shows the promising future of the IT-PIC-PEMs for applications in various IT electrochemical processes including IT-PEMFCs, IT-electrolyzers, etc.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Creation of hollow silica-fiberglass soft ceramics for thermal insulation

Hollow-structured materials show promise in thermal insulation because the shells encapsulating gaseous voids can interrupt heat transport pathways. Here, in this study, we present two low-cost routes to fabricate hollow silica nanoshells, via gas-phase and liquid-phase methods. The gas-phase synthesis method generates hollow shells by a droplet surface precipitation mechanism in a flame aerosol reactor. The liquid-phase synthesis route forms hollow shells by removal of a carbon template, which is produced by hydrothermal reaction of glucose. Both approaches (gas- and liquid-phase) provide hollow silica with amorphous structure, low thermal conductivity (0.023 and 0.026 W m –1 K –1 ), small particle size (442 and 383 nm), thin shell (35 and 36 nm), and low density (0.015 and 0.033 g cm –3 ). We employed high shear mechanical mixing to fabricate hollow silica-fiberglass composite ceramics. The resulting three-dimensional network provides the ceramics with robust mechanical elasticity and fire-retardancy while maintaining low thermal conductivity, dramatically outperforming an analogous material using commercial silica gel in place of the hollow nanoshells. Our findings provide two practical routes to synthesize hollow silica, either of which can be used to manufacture a class of hollow shell-fiber nanocomposite soft ceramics for energy-saving applications.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Advanced silicone materials for soft actuator applications

Soft actuators are at the forefront of the innovation tide in medicine, manufacturing, and aerospace because they are able to mimic the behavior of biological tissue and adapt to complex, unstructured environments. Of all the materials used, silicone-based elastomers have drawn enormous attention since they offer a superb combination of mechanical flexibility, biocompatibility, thermal stability, and long-term durability. In the past few years, there has also been a rapid pace of material evolution, additive manufacturing, and biointegration that has enhanced the performance and applications of silicone-based soft actuators. However, there is no focused and timely review compiling these advances. This review seeks to address that need by critically discussing recent advancements in advanced silicone materials, exploring new fabrication methodologies, and discussing emerging applications that range from wearable devices to implantable robotics. We also present suggestions for directions and the problems which must be addressed in order to further develop the performance and potential of silicone-based soft actuators, justifying the relevance and urgency of this effort.

biocompatibility↗

Unlocking Synergistic Benefits of Colocation of Data Centers at Airports

This white paper evaluates the potential of a new energy system configuration: Strategic colocation of data centers - on airport property or adjacent to airports - in order to realize significant operational, economic, and environmental benefits to airports, data centers, and the communities they serve. While increasing demand from both airports and data centers requires both parties to make significant infrastructure investments, colocation can mitigate some of the energy, land use, permitting, and connectivity challenges of siting and powering these industries.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A thermal evaporation–trapping strategy to synthesize flexible and robust oxygen electrocatalysts for rechargeable zinc–air batteries

Great efforts have been devoted to the development of bifunctional electrocatalysts to accelerate the sluggish kinetics of cathodic oxygen reduction/evolution reactions (ORR/OER) in zinc–air batteries (ZABs). Here we report a thermal evaporation–trapping synergistic strategy to fabricate a bifunctional electrocatalyst of flexible N-doped carbon fiber cloth loaded with both CoFe-oxide nanoparticles and single-atom Co/Fe–Nx sites, in which the thermal evaporation process functions in both downsizing CoFe-oxide nanoparticles and trapping the evaporated Co/Fe species to generate Co/Fe–Nx sites. The obtained flexible electrocatalyst, directly serving as an oxygen electrode, displays a small potential gap of 0.542 V for the OER/ORR, large peak power densities (liquid-state ZAB: 237.4 mW cm2 ; solid-state ZAB: 141.1 mW cm2 ), and excellent charge–discharge cycling stability without decay after working more than 770 hours. Furthermore, in situ Raman spectroscopy characterization and theoretical calculations reveal that CoFe2O4 species is responsible for the OER while atomic Fe/Co sites play a key role in the ORR

Zhang, Hong-Bo↗

Smart and Efficient Building Envelopes: Thermal Switches and Thermal Storage for Energy Savings and Load Flexibility

The building envelope has traditionally been seen as a static component. Much of the past thermal advancements in building envelopes has consisted of developing higher R/inch insulation. While a suitable approach for static situations, it does not consider the dynamic nature of the ambient environment or the varying needs of the electrical grid. This paper will examine three possible ways that building envelopes can be actively managed: 1. thermal switches, 2. thermal storage, and 3. the coupling of the two. Spurring innovation to make building envelopes smarter will help reduce building energy consumption and peak energy usage and contribute to flexibility in energy demand in the future.

Mumme, Sven↗

Flexible Fully-Decoupled Nuclear Plants with Thermal Energy Storage - Technoeconomic Optimization

New nuclear power plants may be one of the technologies for future zero carbon electricity production. These future systems will however also need significant flexibility to cope with fluctuating demand and large share of intermittent renewable supply, rather than running in conventional baseload generation. The present work explores the use of thermal energy storage (TES) as a buffer between the reactor heat and its conversion to electricity, enabling flexible operation of nuclear plants. The focus is on maximizing flexibility, ideally as full decoupling of the nuclear and power cycle islands, as well as on system efficiency in various modes. A system design presented for a high temperature gas cooled reactor (HTGR) presents a slightly complex solution, as separate high- and low-temperature TES systems are required in order to cover the extended temperature range. Although this configuration imposes certain limitations on the discharge system configuration, it also presents the opportunity to design a more efficient system. For this case in particular, a steam reheat cycle is advantageous. Dynamic models were developed for the decoupled system in order to generate insights into aspects of off design operation and system control. A technoeconomic analysis, furthermore, provides sizing and costing of the component, followed by size and dispatch economic optimization considering energy arbitrage. This optimization shows that in all explored markets, the addition of TES system with the proposed configuration results in positive impact on project net present value. Further sensitivity analyses show impact of multiple inputs and possible technical limitations.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Advanced Coating Compositions and Microstructures to Improve Uptime and Operational Flexibility in Cyclic, Low-Load Thermal Utility Plants

GE, the University of Tennessee, and Oak Ridge National Laboratory collaborated from 2020 to 2023 developing two key technologies for improving the viability of fuel switching and load following in thermal utility plants: a) cost-effective weld overlay compositions for boiler tubing b) cathodic arc coatings that deliver improvements in both erosion resistance and oxidation resistance in high temperature steam for HP turbine blades The team worked through a robust, logical project map to de-risk these two technologies and advance them from TRL 3 to TRL 6. For the cost-effective weld overlay, the team developed a ferritic filler material which was fabricated at a vendor for 18% the average market cost of Inconel 625 wire, had a corrosion rate 3x lower in conditions simulating a biomass-fired superheater and 10x lower in conditions simulating a coal-fired superheater, and was fabricated into prototype overlaid tubing that passed ASME requirements including transverse bending, dye penetrant inspection, and ASTM G-76 evaluation. For the cathodic arc coatings applied to steam turbine blades, the team developed a novel composition that was successfully transferred to a qualified vendor. The vendor was able to produce coated prototypes with 4x the as-deposited erosion resistance and 10.4x the post-steam-exposure erosion resistance of the TiN coating the vendor currently applies on GE steam turbine components, without significantly increasing process cost. These coated prototypes also passed a GE inspection and showed favorable performance in high temperature erosion, nanoindentation, sliding wear, scratch adhesion, and high cycle fatigue testing. If successfully deployed by GE, it is anticipated that the technologies will enable the following: • 25%-50% increase in time between outages for both boilers and HP turbines. • 50% decrease in cost for weld overlay on a per foot basis relative to todays NiCr alloys. • Adequate oxidation resistance and erosion for HP turbine inlet steam at >620°C and >220 bar. • No need for changes in component supply chain or any notable Capital Expenditures. 5 Decreasing component cost, increasing performance, and extending time between outages represent direct value propositions to GE and their customers. For the American consumer, these objectives translate into increased grid reliability (fewer unexpected outages), decreased Levelized Cost of Electricity, and improved environmental health (low-loading/load following to accelerate penetration of renewables). The results also have implications for wear resistant tooling, wire arc additive manufacturing, more durable components for syngas cleanup, and deployment of more efficient thermochemical pathways for carbon negative fuel production

09 BIOMASS FUELS↗

Assessing thermal comfort and participation in residential demand flexibility programs

Residential space-conditioning-based demand flexibility (DF) has become an increasingly sought-after method for demand-side load management to enhance grid reliability and facilitate integration of renewable energy generation. However, predicting the effectiveness and flexibility of residential DF resources is challenging due to the variability in household energy use behaviors. Current estimates show that only 50 % of projected savings from DF resources are actualized due to regulatory, technological, and social barriers. From a household perspective, concerns over thermal comfort during space conditioning-based DF events significantly impact participation decisions. Currently, there is a very limited understanding of how thermal comfort during space-conditioning-based DF events in real-world settings impacts household energy use behaviors and, consequently, the success of DF programs in achieving targeted savings. This paper proposes a method to comprehensively assess the thermal comfort implications of DF strategies and presents results of their impacts on DF event participation decisions and demand savings. Here, the proposed method was applied to a heat pump DF field study in Cordova, Alaska. The study’s key findings are: 1) DF event setpoint offsets that maintain indoor operative temperatures between 18 to 22 °C (65 to 71°F) may be preferred in Cordova, Alaska; 2) Household-level thermal comfort is more sensitive to the duration of the DF event than to the degree of temperature offset from baseline conditions; 3) The delayed impact of changes in indoor operative temperature in response to setpoint offsets, both during and after a DF event, influences occupants’ thermal comfort perceptions and willingness to persistently participate in events. The findings from application of the proposed method can help inform future larger-scale occupant-centric DF programs as it can capture information not readily available through utility and device-level energy use data. Thus, it can supplement these sources and help program administrators develop occupant-centric DF strategies, enabling more accurate predictions of participation rates and savings estimates for space-conditioning-based DF programs.

Demand side management↗

Advancements in Development and Testing of Thermal Power Dispatch Simulators

Flexible plant operations and generation (FPOG) offer nuclear power plants (NPPs) the chance to leverage alternative, non-electric revenue streams while ensuring their continued role as reliable, clean, and constant sources of baseload electrical power. The excess thermal energy generated from NPPs during periods of low electricity demand can be channeled as raw materials to numerous industrial processes via a thermal power dispatch (TPD) system. Hydrogen production via high-temperature steam electrolysis (HTSE) is an optimal use case based on technical and economic feasibility. Researchers at Idaho National Laboratory (INL) have conducted previous works that developed and implemented TPD system models within the GSE Solutions Generic Pressurized Water Reactor (GPWR) simulator to support human-in-the-loop (HITL) scenario-based evaluations. The first part of this report documents modifications made to the GPWR TPD model and HMI from the previous iteration in line with a new Sargent and Lundy (S&L) TPD design with an automatic control system. The was done in collaboration with Westinghouse using their three-loop pressurizer water reactor (W3LPWR) simulator which contains an industrial grade automatic control system for the TPD. This was installed in the Human Systems Simulation Laboratory (HSSL) at INL. The second part of the report documents findings from an all-hands-on-deck integration and verification workshop that was conducted in the HSSL over several days. The research team comprised INL human factors and TPD experts, a nuclear engineer from GSE Solutions who implemented the revised TPD model for GPWR, the human-machine interface (HMI) prototyping and human factors team from the University of Idaho, and personnel with operations experience with pressurized water reactors. The workshop provided time and expertise to conduct the final activities to bring the operations, HMI, and simulator into a functional state. The goals of the integration and verification workshop were: 1. to install the revised GPWR TPD model into the HSSL 2. verify the TPD HMI prototype was functional 3. integrate the HTSE Simulink model to GPWR. 3. Issues were identified for resolution, but overall the workshop accomplished its goal to integrated and verify the majority of the intended functional. Future work will resolve the identified issues and use the integrated simulation to support an evaluation and demonstration in the next fiscal year.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Gaussian approximation potentials for accurate thermal properties of two-dimensional materials

Two-dimensional materials (2DMs) continue to attract a lot of attention, particularly for their extreme flexibility and superior thermal properties. Molecular dynamics simulations are among the most powerful methods for computing these properties, but their reliability depends on the accuracy of interatomic interactions. While first principles approaches provide the most accurate description of interatomic forces, they are computationally expensive. In contrast, classical force fields are computationally efficient, but have limited accuracy in interatomic force description. Machine learning interatomic potentials, such as Gaussian Approximation Potentials, trained on density functional theory (DFT) calculations offer a compromise by providing both accurate estimation and computational efficiency. Here, in this work, we present a systematic procedure to develop Gaussian approximation potentials for selected 2DMs, graphene, buckled silicene, and h-XN (X = B, Al, and Ga, as binary compounds) structures. We validate our approach through calculations that require various levels of accuracy in interatomic interactions. The calculated phonon dispersion curves and lattice thermal conductivity, obtained through harmonic and anharmonic force constants (including fourth order) are in excellent agreement with DFT results. HIPHIVE calculations, in which the generated GAP potentials were used to compute higher-order force constants instead of DFT, demonstrated the first-principles level accuracy of the potentials for interatomic force description. Molecular dynamics simulations based on phonon density of states calculations, which agree closely with DFT-based calculations, also show the success of the generated potentials in high-temperature simulations.

2D Materials↗

Design of a Meso-Scale Test of a Fracture Thermal Energy Storage (FTES) System

This paper will present the characterization, scaling, and design of an intermediate-scale field test of a fracture thermal energy storage system (FTES). Seasonal storage of thermal energy has the potential to both significantly reduce the total energy requirements for heating and cooling of buildings, but also allow for the flexibility to store thermal energy from intermittent sources. With approximately half of global energy consumption currently being used for heating and cooling, this represents an important path to reducing greenhouse gas (GHG) emissions. The concept of FTES is to drill two or more wells into a low permeability formation, generally at a depth of less than a few hundred meters, and then generate hydraulic fractures to create flow paths for water to circulate between the wells. Hot or cold thermal energy can then be stored in the surrounding rock mass by circulating hot or cold water through the fractures, which will heat or cool the rock mass. To recover the stored energy, ambient temperature water can be then circulated through the fractures, which will then be heated or cooled by the rock mass. Fractures inherently have a very large ratio of surface area to volume. This allows for very high heat fluxes to and from the rock mass to be achieved despite the relatively low thermal conductivity of most geologic formations. Because large fractures can be made with low-cost equipment and with only inexpensive and environmentally safe materials such as water and sand, the cost to construct even large FTES systems is expected to be quite low. This paper will present what the performance requirements, size, and operating conditions of a full-scale system to operate a commercial building. The paper will describe how these full-scale system characteristics will be used as a design basis for an intermediate-scale FTES test to be conducted at the Sanford Underground Research Facility (SURF) in Lead, SD.

Burghardt, Jeffrey A.↗

Advanced Micro Combined Heat and Power Device

U.S. buildings account for approximately 40% of total U.S. energy consumption and 75% of electricity use, emphasizing the need for efficient, resilient, and secure energy solutions. Micro-combined heat and power (micro-CHP) systems provide an effective approach by simultaneously generating electricity and recovering waste heat for thermal use. However, current commercial micro-CHPs face challenges in achieving higher efficiency, lower emissions, and reduced cost. To address these limitations, a novel micro-CHP prototype powered by a unique opposed-piston four-stroke (OP4S) engine was developed. The OP4S features a simplified, low-cost design with reduced heat losses and dual-piston operation that enables higher thermal efficiency. Experimental results demonstrated up to 35.2% AC electrical efficiency under lean combustion, surpassing the best-performing ICE-based micro-CHPs reported publicly. In addition, the micro-CHP enables a total CHP efficiency exceeding 93%. The prototype operates reliably for over 600 hours, providing flexible and efficient thermal and electrical outputs. This novel OP4S-based micro-CHP offers a resilient, low-cost, and energy-efficient solution suitable for residential, light commercial, and remote community applications across diverse climate zones.

Gao, Zhiming [ORNL] (ORCID:0000000271397995)↗

Nonreciprocal Thermal Emitters Using Metasurfaces with Multiple Diffraction Channels

The emissivity and absorptivity of nonreciprocal thermal emitters are not constrained by the well-known Kirchhoff law of thermal radiation, which usually serves as the theoretical basis to characterize thermal properties. When thermal emitters are nondiffracting, which is the case in previous studies of nonreciprocal thermal emitters, the angular distribution of emissivity and absorptivity is mirror symmetric with respect to the normal direction, and the nonreciprocal effect is confined to a relatively narrow angular range. In this work, we consider nonreciprocal thermal emitters that can simultaneously couple to multiple diffraction channels. We show that the symmetry relation between absorptivity and emissivity can be broken in such multichannel emitters. The angular range in which the nonreciprocal effect is strong can also be significantly broadened. Such multichannel emitters can operate as one-way energy splitters. Our work significantly broadens the flexibility of thermal-radiation control in nonreciprocal thermal-emitter design.

42 ENGINEERING↗

Model Predictive Control for a Grid-interactive Efficient Thermal Storage-integrated Heat Pump System

Building heating and cooling systems can be used to overcome the mismatch between the intermittent supply of renewable power and the fluctuating demand for electricity. A novel underground thermal energy storage integrated with a dual-source heat pump has been proposed to mitigate the mismatch while meeting the thermal demand of buildings efficiently. Conventional thermostat control with heuristic rules cannot provide intelligent decisions to maximize the thermal efficiency and flexibility of the proposed system. Advanced control strategies like model predictive control (MPC) have provided a new paradigm for grid-interactive efficient building operation with the advancement of computation and sensing. This study developed an MPC for the proposed system to provide grid service for Demand Side Management and minimize the operating cost of building owners. A control-oriented dynamic model of the proposed system has been developed. Given an objective function and proper constraints, an optimization problem is formulated to determine the optimal control strategy of the system. Dynamic Programming is adopted to solve the optimization problem. A rule-based control (RBC) is also developed to achieve similar goals. Short-term simulations are conducted to compare the system performance resulting from the two controls. The simulation results indicate that the MPC performs more intelligently than the RBC in charging thermal energy storage and selecting heat pump sources by taking advantage of the predicted cooling demands of the building and the performance of the integrated system. As a result, the MPC could save energy and reduce operating costs compared with the RBC. A case study shows that, for a 3-day operation, the MPC saves 36.9% energy and reduces 38.5% operating cost compared with the RBC.

Shi, Liang↗