Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “temperature”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

On the Trend of the Annual Mean, Maximum, and Minimum Temperature and the Diurnal Temperature Range in the Armagh Observatory, Northern Ireland, Dataset, 1844 -2012

Examined are the annual averages, 10-year moving averages, decadal averages, and sunspot cycle (SC) length averages of the mean, maximum, and minimum surface air temperatures and the diurnal temperature range (DTR) for the Armagh Observatory, Northern Ireland, during the interval 1844-2012. Strong upward trends are apparent in the Armagh surface-air temperatures (ASAT), while a strong downward trend is apparent in the DTR, especially when the ASAT data are averaged by decade or over individual SC lengths. The long-term decrease in the decadaland SC-averaged annual DTR occurs because the annual minimum temperatures have risen more quickly than the annual maximum temperatures. Estimates are given for the Armagh annual mean, maximum, and minimum temperatures and the DTR for the current decade (2010-2019) and SC24.

Wilson, Robert M.↗

Core temperature is regulated, although at a lower temperature, in rats exposed to hypergravic fields

1. In rats acclimated to 23 degrees C (RT rats) or 5 degrees C (CA rats), core temperature (Tc), tail temperature (Tt) and oxygen consumption (VO2) were measured during exposure to a hypergravic field. 2. Rats were exposed for 5.5 h to a 3 g field while ambient temperature (Ta) was varied. For the first 2 h, Ta was 25 degrees C; then Ta was raised to 34 degrees C for 1.5 h. During this period of warm exposure, Tc increased 4 degrees C in both RT and CA rats. Finally, Ta was returned to 25 degrees C for 2 h, and Tc decreased toward the levels measured prior to warm exposure. 3. In a second experiment at 3 g, RT and CA rats were exposed to cold (12 degrees C) after two hours at 25 degrees C. During the one hour cold exposure, Tc fell 1.5 degrees C in RT and 0.5 degree C in CA rats. After cold exposure, when ambient temperature was again 25 degrees C, Tc of RT and CA rats returned toward the levels measured prior to the thermal disturbance. 4. Rats appear to regulate their temperature, albeit at a lower level, in a 3 g field.

NASA Discipline Number 40-30↗

An Analysis of Spatio-Temporal Relationship between Satellite-Based Land Surface Temperature and Station-Based Near-Surface Air Temperature over Brazil

A better understanding of the relationship between land surface temperature (Ts) and near-surface air temperature (Ta) is crucial for improving the simulation accuracy of climate models, developing retrieval schemes for soil and vegetation moisture, and estimating large-scale Ta from satellite-based Ts observations. In this study, we investigated the relationship between multiple satellite-based Ts products, derived from the Atmospheric Infrared Sounder (AIRS) and the Moderate Resolution Imaging Spectroradiometer (MODIS) onboard Aqua satellite, and Ta from 204 meteorological stations over Brazil during 2003–2016. Monthly satellite-based Ts products used in this study include: (1) AIRS Version 6 with 1° spatial resolution, (2) AIRS Version 7 with 1° spatial resolution, (3) MODIS Collection 6 with 0.05° spatial resolution, and (4) MODIS Collection 6 with 1° spatial resolution re-sampled from (3) for a direct comparison with AIRS products. We found that satellite-based Ts is lower than Ta over the forest area, but higher than Ta over the non-forest area. Nevertheless, the correlation coefficients (R) between monthly Ta and four Ts products during 2003–2016 are greater than 0.8 over most stations. The long-term trend analysis shows a general warming trend in temperatures, particularly over the central and eastern parts of Brazil. The satellite products could also observe the increasing Ts over the deforestation region. Furthermore, we examined the temperature anomalies during three drought events in the dry season of 2005, 2010, and 2015. All products show similar spatio-temporal patterns, with positive temperature anomalies expanding in areal coverage and magnitude from the 2005 to 2015 event. The above results show that satellite-based Ts is sensitive in reflecting environmental changes such as deforestation and extreme climatic events, and can be used as an alternative to Ta for climatological studies. Moreover, the observed differences between Ts and Ta may inform how thermal assumptions can be improved in satellite-based retrievals of soil and vegetation moisture or evapotranspiration.

land surface temperature↗

The recovery of polarized apparent temperature distributions of flat scenes from antenna temperature measurements

The reception theory for quasi-monochromatic partially polarized emissions is employed to describe the antenna temperature when observing a flat scene from within or above an absorbing/emitting atmosphere. When the polarization aspects of the antenna and scene are carefully observed, the resulting integral expression for the antenna temperature differs significantly from that reported for polarization invariant temperature distributions. It is observed that the antenna couples to both emitted surface polarizations, and the phase character of the antenna introduces a term involving the product of the polarized and cross-polarized antenna patterns. A matrix approximation of the integral expression is suggested and developed as a means for inverting polarized antenna temperature observations for the underlying partially polarized apparent temperature distributions.

Claassen, J. P.↗

Surface temperatures and temperature gradient features of the US Gulf Coast waters

Satellite thermal infrared data on the Gulf of Mexico show that a seasonal cycle exists in the horizontal surface temperature structure. In the fall, the surface temperatures of both coastal and deep waters are nearly uniform. With the onset of winter, atmospheric cold fronts, which are accompanied by dry, low temperature air and strong winds, draw heat from the sea. A band of cooler water forming on the inner shelf expands, until a thermal front develops seaward along the shelf break between the cold shelf waters and the warmer deep waters of the Gulf. Digital analysis of the satellite data was carried out in an interactive mode using a minicomputer and software. A time series of temperature profiles illustrates the temporal and spatial changes in the sea-surface temperature field.

Huh, O. K.↗

Measurement of small temperature fluctuations at high average temperature

Both absolute and differential temperature measurements were simultaneously performed as a function of time for a pixel on a high-temperature, multi-spectral, spatially and temporally varying infrared target simulator. A scanning laser beam was used to maintain a pixel at an on-the-average constant temperature of 520 K. The laser refresh rate of up to 1 kHz resulted in small-amplitude temperature fluctuations with a peak-to-peak amplitude of less than 1 K. The experimental setup to accurately measure the differential and the absolute temperature as a function of time is described.

Scholl, James W.↗

A high-speed spatial (linear) scanning pyrometer: A tool for diagnostics, temperature mapping, and property determinations at high temperatures

Development of a fast spatial scanning pyrometer for temperature measurements above 1500 K is described. The salient features of the pyrometer are: (1) it measures spectral radiance temperature (at 0.65 micron) at 1024 points along a straight line (25 mm long) on the target; (2) it has no moving parts and uses a self-scanning linear array of silicon photodiodes as the detector; (3) its output is recorded digitally every 1 microsec with a full-scale resolution of about 1 part in 4000, permitting performance of a complete cycle of measurements (1024 points) in about 1 ms. Operational characteristics of the pyrometer are given. Examples of measurements of the temperature along rapidly heated (resistive self-heating) specimens (rod, tube, strip) are presented. Potential use of the pyrometer in the experiments, both ground-based and in microgravity, requiring temperature mapping and property distribution of the specimen at high temperatures is discussed.

Cezairliyan, A.↗

Dynamic Response of Turbine-blade Temperature to Exhaust-gas Temperature for Gas-turbine Engines

The frequency of blade temperature to exhaust gas temperature is presented for two locations in the blade and at several operating conditions. The frequency response was determined by Fourier analysis of transient data. Two analytical methods are presented, and results are compared with experimental data. Dynamic response of turbine-blade temperature to exhaust-gas temperature exhibited the form of an approximate first-order lag. The results are used to predict blade temperature for a typical controlled and uncontrolled gas-turbine engine.

HEAT TRANSFER THEORY AND EXPERIMENT↗

Airborne brightness temperature measurements of the polar winter troposphere as part of the Airborne Arctic Stratosphere Experiment 2 and the effect of brightness temperature variations on the diabatic heating in the lower stratosphere

In this paper we report radiometric measurements of tropospheric brightness temperatures obtained during the AASE 2 experiment. These measurements represent the first attempt to characterize effective radiative temperatures as seen from above the troposphere during the Arctic winter. The reported measurements include brightness temperatures at 6.7 and 10.5 microns as seen from the NASA DC-8 aircraft flying at about 11 km altitude. We also present radiative transfer calculations to estimate the effect of tropospheric brightness temperature on the lower stratospheric heating rates. Because of the recent massive eruption of the Pinatubo volcano, we also discuss the effects of a volcanic aerosol layer. It is concluded that small particles like the volcanic aerosol or polar stratospheric clouds (PSCs) type 1 do not affect stratospheric heating rates by much; on the other hand, larger particles, PSCs types 2 and 3, may have significant effects on heating rates and consequently on dynamics of the lower stratosphere. The dynamical effects of local stratospheric temperature variations are briefly discussed.

Valero, Francisco P. J.↗

Airborne Brightness Temperature Measurements of the Polar Winter Troposphere as Part of the Airborne Arctic Stratosphere Experiment 2 and the Effect of Brightness Temperature Variations on the Diabatic Heating in the Lower Stratosphere

In this paper we report radiometric measurements of tropospheric brightness temperatures obtained during the AASE 2 experiment. These measurements represent the first attempt to characterize effective radiative temperatures as seen from above the troposphere during the Arctic winter. The reported measurements include brightness temperatures at 6.7 and 10.5 micrometers as seen from the NASA DC-8 aircraft flying at about 11 km altitude. We also present radiative transfer calculations to estimate the effect of tropospheric brightness temperature on the lower stratospheric heating rates. Because of the recent massive eruption of the Pinatubo volcano, we also discuss the effects of a volcanic aerosol layer. It is concluded that small particles like the volcanic aerosol or PSCs type 1 do not affect stratospheric heating rates by much; on the other hand, larger particles, PSCs types 2 and 3, may have significant effects on heating rates and consequently on dynamics of the lower stratosphere. The dynamical effects of local stratospheric temperature variations are briefly discussed.

Valero, Francisoco P. J.↗

Room Temperature and Elevated Temperature Composite Sandwich Joint Testing

Testing of composite sandwich joint elements has been completed to verify the strength capacity of joints designed to carry specified running loads representative of a high speed civil transport wing. Static tension testing at both room and an elevated temperature of 350 F and fatigue testing at room temperature were conducted to determine strength capacity, fatigue life, and failure modes. Static tension test results yielded failure loads above the design loads for the room temperature tests, confirming the ability of the joint concepts tested to carry their design loads. However, strength reductions as large as 30% were observed at the elevated test temperature, where all failure loads were below the room temperature design loads for the specific joint designs tested. Fatigue testing resulted in lower than predicted fatigue lives.

Walker, Sandra P.↗

Elevated-Temperature "Ultra" Fast Fracture Strength of Advanced Ceramics: An Approach to Elevated-Temperature "Inert" Strength

The determination of "ultra" fast fracture strengths of five silicon nitride ceramics at elevated temperatures has been made by using constant stress-rate ("dynamic fatigue") testing with a series of "ultra" fast test rates. The test material included four monolithic and one SiC whisker-reinforced composite silicon nitrides. Of the five test materials, four silicon nitrides exhibited the elevated -temperature strengths that approaches their respective room-temperature strengths at an "ultra" fast test rate of 3.3 x 10(exp 4) MPa/s. This implies that slow cracks growth responsible for elevated-temperature failure can be eliminated or minimized by using the "ultra" fast test rate. These ongoing experimental results have shed light on laying a theoretical and practical foundation on the concept and definition of elevated-temperature "inert" strength behavior of advanced ceramics.

Choi, S. R.↗

Alumina Encapsulated Strain Gage Not Mechanically Attached To The Substrate, Used to Temperature Compensate an Active High Temperature Gage In A Half-Bridge Configuration

A temperature compensation element for a high-temperature strain gage and the method of fabricating the same. Preferably, the element is a "dummy" strain gage not mechanically attached to the substrate. The element is encapsulated in an insulative material and used to compensate an active high-temperature strain gage and wired in a half-bridge configuration. The temperature compensation element and high-temperature strain gage are fabricated using the method of the present invention. This method includes temporarily adhering the element to a heat sink, encapsulated in an insulative material and then removed from the heat sink. Next, the element is either stacked or placed near the active gage. Ideally, the element and the active gage have substantially similar heat transfer and electrical properties.

Anthony Piazza↗

Development of Temperature Sensitive Paints for the Detection of Small Temperature Differences

Temperature sensitive paints (TSP s) have recently been used to detect small temperature differences on aerodynamic model surfaces. These types of applications impose stringent performance requirements on a paint system. The TSP s must operate over a broad temperature range, must be physically robust (cannot chip or peel), must be polishable to at least the smoothness of the model surface, and must have sufficient sensitivity to detect small temperature differences. TSP coatings based on the use of metal complexes in polymer binders were developed at NASA Langley Research Center which meet most of the requirements for detection of small temperature differences under severe environmental conditions.

Oglesby, Donald M.↗

High-Temperature Extensometry and PdCr Temperature-Compensated Wire Resistance Strain Gages Compared

A detailed experimental evaluation is underway at the NASA Lewis Research Center to compare and contrast the performance of the PdCr/Pt dual-element temperature-compensated wire resistance strain gage with that of conventional high-temperature extensometry. The advanced PdCr gage, developed by researchers at Lewis, exhibits desirable properties and a relatively small and repeatable apparent strain to 800 C. This gage represents a significant advance in technology because existing commercial resistance strain gages are not reliable for quasi-static strain measurements above approx. 400 C. Various thermal and mechanical loading spectra are being applied by a high-temperature thermomechanical uniaxial testing system to evaluate the two strain-measurement systems. This is being done not only to compare and contrast the two strain sensors, but also to investigate the applicability of the PdCr strain gage to the coupon-level specimen testing environment typically employed when the high-temperature mechanical behavior of structural materials is characterized. Strain measurement capabilities to 800 C are being investigated with a nickel-base superalloy, Inconel 100 (IN 100), substrate material and application to TMC's is being examined with the model system, SCS-6/Ti-15-3. Furthermore, two gage application techniques are being investigated in the comparison study: namely, flame-sprayed and spot welding. The apparent strain responses of both the weldable and flame-sprayed PdCr wire strain gages were found to be cyclically repeatable on both IN 100 and SCS-6/Ti-15-3 [0]_8. In general, each gage exhibited some uniqueness with respect to apparent strain behavior. Gages mounted on the IN 100 specimens tended to show a repeatable apparent strain within the first few cycles, because the thermal response of IN 100 was stable. This was not the case, however, for the TMC specimens, which typically required several thermal cycles to stabilize the thermal strain response. Thus, progressive changes in the apparent strain behavior were corroborated by the extensometer, which unlike the mounted gage can distinguish quantitative changes in the material's thermal strain response. One specimen was instrumented with both a fixed and floating gage. From the difference in output of these two gages, the thermal expansion strains were calculated. These data, which are given in the figure, show excellent agreement with the values measured by the high-temperature extensometry.

Source record↗

Effect of Upper-Cycle Temperature on the Load-Biased, Strain-Temperature Response of NiTi

Over the past decade, interest in shape memory alloy based actuators has increased as the primary benefits of these solid-state devices have become more apparent. However, much is still unknown about the characteristic behavior of these materials when used in actuator applications. Recently we have shown that the maximum temperature reached during thermal cycling under isobaric conditions could significantly affect the observed mechanical response of NiTi (55 wt% Ni), especially the amount of transformation strain available for actuation and thus work output. This investigation extends that original work to ascertain whether further increases in the upper-cycle temperature would produce additional improvement in the work output of the material, which has a stress-free Af of 113 oC, and to determine the optimum cyclic conditions. Thus, isobaric, thermal-cycle experiments were conducted in the aforementioned alloy at various stress levels from 50-300 MPa using upper-cycle temperatures of 165, 200, 230, 260, 290, 320 and 350 oC. The data indicated that the amount of applied stress influenced the transformation strain available in the system, as would be expected. However, the maximum temperature reached during the thermal excursion also plays a role in determining the transformation strain, with the maximum transformation strain being developed by thermal cycling to 290 oC. In situ, neutron diffraction showed that the differences in transformation strain were related to differences in martensite texture within the microstructure when cycling to different upper-cycle temperatures. Hence, understanding this effect is important to optimizing the operation of SMA-based actuators and could lead to new methods for processing and training shape memory alloys for optimal performance.

Padula, Santo, II↗

Temperature Trends in the Tropical Upper Troposphere and Lower Stratosphere: Connections with Sea Surface Temperatures and Implications for Water Vapor and Ozone

Satellite observations and chemistry-climate model experiments are used to understand the zonal structure of tropical lower stratospheric temperature, water vapor, and ozone trends. The warming in the tropical upper troposphere over the past 30 years is strongest near the Indo-Pacific warm pool, while the warming trend in the western and central Pacific is much weaker. In the lower stratosphere, these trends are reversed: the historical cooling trend is strongest over the Indo-Pacific warm pool and is weakest in the western and central Pacific. These zonal variations are stronger than the zonal-mean response in boreal winter. Targeted experiments with a chemistry-climate model are used to demonstrate that sea surface temperature (hereafter SST) trends are driving the zonal asymmetry in upper tropospheric and lower stratospheric tropical temperature trends. Warming SSTs in the Indian Ocean and in the warm pool region have led to enhanced moist heating in the upper troposphere, and in turn to a Gill-like response that extends into the lower stratosphere. The anomalous circulation has led to zonal structure in the ozone and water vapor trends near the tropopause, and subsequently to less water vapor entering the stratosphere. The radiative impact of these changes in trace gases is smaller than the direct impact of the moist heating. Projected future SSTs appear to drive a temperature and water vapor response whose zonal structure is similar to the historical response. In the lower stratosphere, the changes in water vapor and temperature due to projected future SSTs are of similar strength to, though slightly weaker than, that due directly to projected future CO2, ozone, and methane.

water vapor↗

Low-temperature Brayton radiator performance in a variable-sink-temperature environment

An analysis of the performance of a low-temperature Brayton space radiator is presented. The cylindrical radiator with circumferential tubes was subjected to an equivalent sink temperature environment that varied along the fluid flow path. The radiator performance, as measured by fluid outlet temperature, was found to be dependent on the orbital position and the location of the radiator inlet relative to the sink temperature environment. An approximate dynamic analysis of sun-shade variations in performance is included.

Bien, D. B.↗