Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “systems testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Measurements of SCRF cavity dynamic heat load in horizontal test system

The Horizontal Test System (HTS) at Fermilab is currently testing fully assembled, dressed superconducting radio frequency (SCRF) cavities. These cavities are cooled in a bath of superfluid helium at 1.8K. Dissipated RF power from the cavities is a dynamic heat load on the cryogenic system. The magnitude of heat flux from these cavities into the helium is also an important variable for understanding cavity performance. Methods and hardware used to measure this dynamic heat load are presented. Results are presented from several cavity tests and testing accuracy is discussed.

43 PARTICLE ACCELERATORS↗

Compatibility Tests Between the Mars Vehicle System Test Bed and RIMFAX Radar Antenna Prototype for the Mars 2020 Mission

NASA's Mars 2020 rover will carry a wideband (150 megahertz to 1200 megahertz) ground penetrating radar—RIMFAX (Radar Imager for Mars’ subsurFace eXperiment ), contributed by FFI (Forsvarets forskningsinstitutt) of Norway—to survey the subsurface geology of Mars. RIMFAX will take radar soundings while the rover drives across the Martian terrain, which presents possible compatibility issues between rover and radar operations. In order to study this risk, a prototype RIMFAX antenna was attached to the flight-analogous rover Vehicle System Test Bed (VSTB) in a mechanically representative location. The prototype antenna collected spectral and time-domain data across a variety of driving operations in order to assess the radar sensitivity to rover-generated noise. Conversely, the prototype antenna was driven while an engineering-model UHF (Ultra High Frequency) antenna used for rover telecom measured received in-band power to ensure that the rover hardware was not at risk of damage. Evaluation of the data by the instrument science team showed that while rover noise was apparent to the receiver, data post-processing would yield greater than 40 decibels margin to the science requirements. Similarly, power levels received by the UHF antenna were well below damage thresholds.

Gonzales, Edward↗

Input-output characterization of an ultrasonic testing system by digital signal analysis

Ultrasonic test system input-output characteristics were investigated by directly coupling the transmitting and receiving transducers face to face without a test specimen. Some of the fundamentals of digital signal processing were summarized. Input and output signals were digitized by using a digital oscilloscope, and the digitized data were processed in a microcomputer by using digital signal-processing techniques. The continuous-time test system was modeled as a discrete-time, linear, shift-invariant system. In estimating the unit-sample response and frequency response of the discrete-time system, it was necessary to use digital filtering to remove low-amplitude noise, which interfered with deconvolution calculations. A digital bandpass filter constructed with the assistance of a Blackman window and a rectangular time window were used. Approximations of the impulse response and the frequency response of the continuous-time test system were obtained by linearly interpolating the defining points of the unit-sample response and the frequency response of the discrete-time system. The test system behaved as a linear-phase bandpass filter in the frequency range 0.6 to 2.3 MHz. These frequencies were selected in accordance with the criterion that they were 6 dB below the maximum peak of the amplitude of the frequency response. The output of the system to various inputs was predicted and the results were compared with the corresponding measurements on the system.

Williams, J. H., Jr.↗

High Power Alternator Test Unit (ATU) Electrical System Test

The Alternator Test Unit (ATU) in the Lunar Power System Facility (LPSF) located at the NASA Glenn Research Center (GRC) in Cleveland, OH was used to simulate the operating conditions and evaluate the performance of the ATU and it s interaction with various LPSF components in accordance with the JIMO AC Power System Requirements. The testing was carried out at the breadboard development level. Results of these tests will be used for the development and validation of analytical models for performance and lifetime prediction.

Birchenough, Arthur↗

Automated Testing System

The Automated Testing System (ATS) is an open-source, Python-based tool for automating the running of tests of an application across a broad range of high performance computers.

Dempsey, StephanieM.↗

Testing Facility Uncertainty Analyses for RBCC Systems Testing

The Rocket Based Combined Cycle (RBCC) engine is expected to evolve based upon past combined-cycle propulsion test experience/data and new extensive test data. Currently, it is envisioned that a portion of the component and system testing will be pursued at NASA Stennis Space Center (SSC). To realize the greatest benefit of the test data, uncertainty analyses are being performed on the relevant RBCC components and systems to be tested at NASA SSC to ascertain the needed measurement requirements. These studies pertain to the existing E-Complex test stands as well as a new facility, E-4. This paper describes the approach used in the studies and gives examples to demonstrate the approach and the usefulness of the results. Future work will greatly increase the reliability of the test data while minimizing costs by focusing expenditures in the proper areas that are critical to program success and not allowing resources to be wasted in areas that are not significant relative to overall program goals.

Hudson, Susan T.↗

The NASA/LRC Computerized Test System

A new testing package, including apparatus and tasks for the behavioral study of a number of species in a variety of experiments is presented. The package is described with respect to the kinds of comparative psychological investigations for which it is best suited. The preliminary data generated within this new testing paradigm demonstrate that the NASA/LRC Computerized Test System provides a flexible yet powerful environment for the investigation of behavioral and psychological processes.

Richardson, W. Kirk↗

An ERCOT test system for market design studies

An open source test system is developed that permits the dynamic modeling of centrally-managed wholesale power markets operating over highvoltage transmission grids. In default mode, the test system models basic operations in the Electric Reliability Council of Texas (ERCOT): namely, centrally-managed day-ahead and real-time markets operating over successive days, with congestion handled by locational marginal pricing. These basic operational features characterize all seven U.S. energy regions organized as centrally-managed wholesale power markets. Modeled participants include dispatchable generators, load-serving entities, and non-dispatchable generation such as unrmed wind and solar power. Users can congure a broad variety of parameters to study basic market and grid features under alternative system conditions. Users can also easily extend the test system's Java/Python software classes to study modied or newly envisioned market and grid features. Finally, the test system is integrated with a high-level simulation framework that permits it to function as a software component within larger systems, such as multi-country systems or integrated transmission and distribution systems. Finally, detailed test cases with 8-bus and 200-bus transmission grids are reported to illustrate these test system capabilities.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

The effect of test system misalignment in the dynamic tension test

The effects of test system misalignment are analyzed for dynamic tension tests using sheet type rectangular 1100-0 aluminum specimens. The strain rate is assumed constant only on the natural axis of the specimen even though the specimen is subjected to a constant strain rate test. The results include: (1) the lower the strain rate, the more significant the misalignment errors become; (2) misalignment errors of 50% are found at the extreme fibers of the specimen; (3) the strain rate variation in the cross section decreases with increasing plastic strain and vanishes at plastic strain equal to 0.8% at the midspan of the specimen; and (4) the neutral axis shifts toward the centerline of the specimen as the plastic strain increases, but it reaches a limit and does not completely move back to the centerline.

Wu, H. C.↗

Flight Test Results for the HST Orbital Systems Test (HOST) Capillary Pump Loop Cooling System

The Near Infrared Camera and Multi Object Spectrometer (NICMOS) was installed in the Hubble Space Telescope (MST) in February 1997. Shortly thereafter, the instrument experienced a thermal short in its solid nitrogen dewar system which will significantly shorten the instrument's useful life. A reverse Brayton cycle mechanical refrigerator will be installed during the Third Servicing Mission (SM3) to provide cooling for the instrument, and thereby extend its operations. A Capillary Pump Loop (CPL) and radiator system was designed, built and tested to remove up to 500 watts of heat from the mechanical cryocooler and its associated electronics. The HST Orbital Systems Test (HOST) platform was flown on the Space Shuttle Discovery (STS-95) as a flight demonstration of the cryocooler system, CPL control electronics, and the CPL/Radiator. This paper will present the flight test results and thermal performance of the CPL system in detail.

Buchko, M.↗

xEMU Suit Integrated Audio Communications System: Ambient and EVA Pressure Testing System Performance

Testing across several airlock and EVA thermal and pressure scenarios has demonstrated that the Integrated Audio System of NASA’s Exploration Extravehicular Mobility Unit (xEMU) spacesuits transmits and receives intelligible audio communications without the use of a commcap or similar worn device. The xEMU audio system consists of internal loudspeakers and digital microphones (Integrated Communications System –ICS) combined with an adaptive Acoustic Echo Canceller (AEC), outbound voice operated transmission (VOX), and automatic gain control (AGC). Transducers are mounted in an “exploded commcap” configuration with helmet-attached speakers near the ears and three microphones positioned at the collar. The AGC removes inbound audio signals (e.g.,suit, Mission Control, Lander, C&W tones) from the outbound comms stream, reducing echo and feedback (squeal) in low-noise suit environments. The reduction of worn communication equipment increases crewmember comfort, range of movement, and situational awareness. However, test results also highlight the need for proper fan, duct, pump, and gas flow integration with suit acoustics and audio. Ductwork may serve as waveguides for various component and structure-borne noise. Sharply angled ducts can generate turbulent-flow noise. Gas flow from inlets above the crewmember’s head can generate noise when cascading over the faceplate and collar (or commcap) microphones. Sufficient acoustic noise levels (1) require increased gain to boost inbound audio, and (2) may distort signals resulting in AEC disruption or artifacts. Suit-noise levels decline with reduced pressure (density), but then elevated speech and audio effort/power become necessary. Whether the Integrated Audio System, commcap, or other device is used, suit acoustic noise can mask speech in outbound comms. This reduces intelligibility and requires other AECs/devices to suppress comms noise. Yet, adjusting a few components may yield significant improvement. We discuss xEMU audio functionality, demonstrate how acoustical treatment combined with inbound signal conditioning improved clarity during tests, and discuss future modifications.

xEMU↗

xEMU Suit Integrated Audio Communications System: Ambient and EVA Pressure Testing System Performance

Testing across several airlock and EVA thermal and pressure scenarios has demonstrated that the Integrated Audio System of NASA’s Exploration Extravehicular Mobility Unit (xEMU) spacesuits transmits and receives intelligible audio communications without the use of a commcap or similar worn device. The xEMU audio system consists of internal loudspeakers and digital microphones (Integrated Communications System –ICS) combined with an adaptive Acoustic Echo Canceller (AEC), outbound voice operated transmission (VOX), and automatic gain control (AGC). Transducers are mounted in an “exploded commcap” configuration with helmet-attached speakers near the ears and three microphones positioned at the collar. The AGC removes inbound audio signals (e.g.,suit, Mission Control, Lander, C&W tones) from the outbound comms stream, reducing echo and feedback (squeal) in low-noise suit environments. The reduction of worn communication equipment increases crewmember comfort, range of movement, and situational awareness. However, test results also highlight the need for proper fan, duct, pump, and gas flow integration with suit acoustics and audio. Ductwork may serve as waveguides for various component and structure-borne noise. Sharply angled ducts can generate turbulent-flow noise. Gas flow from inlets above the crewmember’s head can generate noise when cascading over the faceplate and collar (or commcap) microphones. Sufficient acoustic noise levels (1) require increased gain to boost inbound audio, and (2) may distort signals resulting in AEC disruption or artifacts. Suit-noise levels decline with reduced pressure (density), but then elevated speech and audio effort/power become necessary. Whether the Integrated Audio System, commcap, or other device is used, suit acoustic noise can mask speech in outbound comms. This reduces intelligibility and requires other AECs/devices to suppress comms noise. Yet, adjusting a few components may yield significant improvement. We discuss xEMU audio functionality, demonstrate how acoustical treatment combined with inbound signal conditioning improved clarity during tests, and discuss future modifications.

xEMU↗

Accelerated-weathering test-system for solar cells

Test system rapidly evaluates effects of sunlight, humidity, and temperature. System accelerates environmental testing since Sunlight is held at equivalent noon exposure (for a selected locality) for 12 hours; alternating light and dark periods are included to check for possible dark reactions in specimens.

Kolyer, J. M.↗

A closed-loop automatic control system for high-intensity acoustic test systems.

Sound at sound pressure levels in the range from 130 to 160 dB is used in the investigation. Random noise is passed through a series of parallel filters, generally 1/3-octave wide. A basic automatic system is investigated because of preadjustment inaccuracies and high costs found in a study of a typical manually controlled acoustic testing system. The unit described has been successfully used in automatic acoustic tests in connection with the spacecraft tests for the Mariner 1971 program.

Slusser, R. A.↗

Automated System Tests High-Power MOSFET's

Computer-controlled system tests metal-oxide/semiconductor field-effect transistors (MOSFET's) at high voltages and currents. Measures seven parameters characterizing performance of MOSFET, with view toward obtaining early indication MOSFET defective. Use of test system prior to installation of power MOSFET in high-power circuit saves time and money.

Huston, Steven W.↗

Transmission Expansion Planning Test System for AC/DC Hybrid Grid With High Variable Renewable Energy Penetration

Test systems are important tools and benchmark for power system research. Currently, there is a lack of standard test systems for modern transmission expansion planning (TEP) research, especially under high variable renewable energy (VRE) penetrations. This article describes a 38-bus test system named the HRP-38 system dedicated to TEP. “HRP” stands for high renewable penetration. The objective of establishing such a system is to provide a consistent platform for different TEP methods to be tested and compared. The test system considers high VRE penetration of more than 30% energy share, which will be an important feature in many power systems in the future. Both AC and DC candidate lines are given to provide sufficient transmission planning alternatives. The complexity of the test system is well balanced considering calculation tractability and the ability to test the performance of the TEP planning model. The network topology, generation mix and load characteristics are described in detail. Year-round time series of VRE (wind power and PV) output and load curves for each bus are provided to facilitate a detailed evaluation of the transmission grid configuration under high VRE penetration. Finally, four benchmark results with different optimization settings are provided for the HRP-38 system.

AC/DC hybrid↗