Improvements to the Airborne Visible/Infrared Imaging Spectrometer (AVIRIS) Calibration System

As a continuing effort to increase the calibration accuracy of the AVIRIS data a number of recent improvements have been implemented and are in the process of being tested during the 1994 flight season. These include the following innovations: A direct observation of a laboratory radiance standard is now used to double check the wide field-of-view calibration via an integrating sphere source. Launch site field calibration of the AVIRIS sensor is now being planned to augment the laboratory and inflight calibration. Modification to a dry air conditioning unit has been made to enable ground calibration at flight operating temperatures. One hundred lines of dark imagery has been added to the end of each flight line to assist in the analysis and removal of residual coherent noise. The intensity of the onboard calibration lamp has been modified to improve response in the blue end of the spectrum. Novel spectral filters have been installed in the onboard calibration source.

Airborne Visible/Infrared Imaging Spectrometer Cal↗

Automatic force balance calibration system

A system for automatically calibrating force balances is provided. The invention uses a reference balance aligned with the balance being calibrated to provide superior accuracy while minimizing the time required to complete the calibration. The reference balance and the test balance are rigidly attached together with closely aligned moment centers. Loads placed on the system equally effect each balance, and the differences in the readings of the two balances can be used to generate the calibration matrix for the test balance. Since the accuracy of the test calibration is determined by the accuracy of the reference balance and current technology allows for reference balances to be calibrated to within +/-0.05% the entire system has an accuracy of +/-0.2%. The entire apparatus is relatively small and can be mounted on a movable base for easy transport between test locations. The system can also accept a wide variety of reference balances, thus allowing calibration under diverse load and size requirements.

Ferris, Alice T.↗

Automatic force balance calibration system

A system for automatically calibrating force balances is provided. The invention uses a reference balance aligned with the balance being calibrated to provide superior accuracy while minimizing the time required to complete the calibration. The reference balance and the test balance are rigidly attached together with closely aligned moment centers. Loads placed on the system equally effect each balance, and the differences in the readings of the two balances can be used to generate the calibration matrix for the test balance. Since the accuracy of the test calibration is determined by the accuracy of the reference balance and current technology allows for reference balances to be calibrated to within .+-.0.05%, the entire system has an accuracy of a .+-.0.2%. The entire apparatus is relatively small and can be mounted on a movable base for easy transport between test locations. The system can also accept a wide variety of reference balances, thus allowing calibration under diverse load and size requirements.

Ferris, Alice T.↗

Vacuum gage calibration system for 10 to the minus 8th power to 10 torr

Calibration system consists of a gas source, a source pressure gage, source volume, transfer volume and test chamber, plus appropriate piping, valves and vacuum source. It has been modified to cover as broad a range as possible while still providing accuracy and convenience.

Holanda, R.↗

Langley Automated Sensor Inter-calibration System (LASICS): Open Access Tools for Satellite Imager Inter-Calibration

Satellite imager calibration teams are tasked with maintaining stable measurement records to facilitate reliable monitoring of geophysical parameters and ensure dependable input for weather forecast models. Satellite imagers are neither uniformly calibrated nor radiometrically scaled to a common reference. Consistent inter-calibration between various earth-orbiting satellite imager pairs is a critical step in the creation of seamless earth-scene reflectance data records over time for input to higher level algorithms that retrieve earth system climate-sensitive properties. Each imager inherently by virtue of its optics (and associated properties like Spectral Response etc.) will have a unique measurement of the same earth-scene reflected signal. A key part of this is the identification and prediction of events where the imager pairs from their respective earth-orbits view the same stable terrestrial targets with nearly identical viewing and solar geometry. Langley Automated Sensor Inter-calibration System (LASICS) will provide the Earth remote sensing community with a foundation for the harmonization of these remote sensing records by the development of an intuitive, user-friendly, interactive web-based open access service that will leverage, an existing extensive and ever-growing database of earth-imager channel spectral response functions, on-demand capabilities for computation and visualization of spectral band adjustment factors using a variety of external hyper-spectral earth observation sources (e.g. SCIAMACHY, GOME-2 for VIS and IASI, AIRS for IR) and a variety of Solar Irradiance Spectra.

Arun Gopalan↗

Automatic flowmeter calibration system

A system for automatically calibrating the accuracy of a flowmeter is described. The system includes a calculator capable of performing mathematical functions responsive to receiving data signals and function command signals. A prover cylinder is provided for measuring the temperature, pressure, and time required for accumulating a predetermined volume of fluid. Along with these signals, signals representing the temperature and pressure of the fluid going into the meter are fed to a plurality of data registers. Under control of a progress controller, the data registers are read out and the information is fed through a data select circuit to the calculator. Command signals are also produced by a function select circuit and are fed to the calculator set indicating the desired function to be performed. The reading is then compared with the reading produced by the flowmeter.

Lisle, R. V.↗

Mossbauer vibration calibration systems evaluated

Mossbauer effect vibration calibrator measures the velocity of high frequency, low amplitude vibration at various velocity and frequency ranges. It contains a highly precise calibrations standard unit and a vibration measuring system and may be applied to ultrafine testing and calibrating prezoelectric shakers, and vibration transducers.

Hobbs, J. V.↗

Automatic Calibration Systems

A continuous requirement exists for calibration and environmental testing of instruments in use at multitude of test facilities at Langley Research Center. Brief summarizes several automated systems available for calibration of research instruments to include: six-component balance, multimeter, amplifier, pyrometer, voltage-controlled oscillator, pressure transducer and accelerometer.

Ferris, A. T.↗

Coastal zone color scanner 'system calibration': A retrospective examination

During its lifetime the Coastal Zone Color Scanner (CZCS) produced approximately 66,000 images. These have been placed in an archive of 'raw' radiance (sensor counts) in a subsampled format that is easily accessible. They have also been processed to form global fields, at reduced resolution, of normalized water-leaving radiance, phytoplankton pigments, and diffuse attenuation coefficient. Using this archive, we have tried to characterize some aspects of the 'system calibration' for the 8-year lifetime of CZCS. Specifically, we have assumed that the sensitivity of the red band decayed in a simple manner similar to the well-known long-term degradation of the shorter-wavelength bands, and we examined the sensitivity of the green and yellow bands by computing the globally averaged water-leaving radiance, over 10-day periods, for all of the imagery. The results provided evidence that in addition to the long-term degradation, short-term (2 weeks to 1 month) variations in the radiometric sensitivity of these bands started in early fall 1981 and continued for the rest of the mission. In contrast, the data suggested the absence of such variations prior to August 1981. It is reasonable to believe that the sensitivity of the blue (and probably the red) band underwent such variations as well; however our methodology cannot be used to study the other bands. Thus, after these fluctuations began, the actual values of CZCS - estimated pigment concentrations at a given location should be viewed with skepticism; however, the global patterns of derived pigment concentrations should be valid. Had an extensive set of surface measurements of water-leaving radiance, e.r., from moored buoyes or drifters, had been available during the CZCS mission, these fluctuations could have been removed from the data set, and this would have greatly increased its value. The lessons learned from CZCS that is, the requirement of good radiometric calibration and stability and the necessity of 'sea truth' stations to monitor the performance of the system (sensor plus algorithms), are being applied to the sea-viewing wide-field-of-view senso (Sea WiFS) scheduled for launch in August 1993.

Evans, Robert H.↗

Langley Automated Sensor Inter-calibration System (LASICS): Open Access Tools for Satellite Imager Inter- Calibration

Satellite imager calibration teams are tasked with maintaining stable measurement records to facilitate reliable monitoring of geophysical parameters and ensure dependable input for forecast models. Satellite imagers are neither uniformly calibrated nor radiometrically scaled to a common reference standard. Consistent inter-calibration between various earth-orbiting satellite imager pairs is a critical step in the creation of seamless earth-scene reflectance data records over time for input to higher level algorithms that retrieve earth system climate-sensitive properties. Each imager inherently by virtue of its optics (and associated properties like spectral response etc.) and orbit will have a unique measurement of the same earth-scene reflected signal. A key part of this is the computationally efficient and optimal identification and prediction of science opportunities where the imager pairs from the irrespective earth-orbits near-simultaneously view the same stable terrestrial targets with nearly identical viewing and solar geometry.

Arun Gopalan↗

A gamma ray observatory ground attitude error analysis study using the generalized calibration system

The Goddard Space Flight Center (GSFC) Flight Dynamics Division (FDD) will be responsible for performing ground attitude determination for Gamma Ray Observatory (GRO) support. The study reported in this paper provides the FDD and the GRO project with ground attitude determination error information and illustrates several uses of the Generalized Calibration System (GCS). GCS, an institutional software tool in the FDD, automates the computation of the expected attitude determination uncertainty that a spacecraft will encounter during its mission. The GRO project is particularly interested in the uncertainty in the attitude determination using Sun sensors and a magnetometer when both star trackers are inoperable. In order to examine the expected attitude errors for GRO, a systematic approach was developed including various parametric studies. The approach identifies pertinent parameters and combines them to form a matrix of test runs in GCS. This matrix formed the basis for this study.

Ketchum, E.↗

Absolute low-pressure calibration system

McLeod gage is used as the primary reference standard in a system used for absolute calibration of vacuum gages in the very low pressure range. The system involves steady-state flow of a gas through a cascade of differentially pumped chambers or stages connected by precisely defined orifices.

Roehrig, J. R.↗

Variable Acceleration Force Calibration System (VACS)

Conventionally, force balances have been calibrated manually, using a complex system of free hanging precision weights, bell cranks, and/or other mechanical components. Conventional methods may provide sufficient accuracy in some instances, but are often quite complex and labor-intensive, requiring three to four man-weeks to complete each full calibration. To ensure accuracy, gravity-based loading is typically utilized. However, this often causes difficulty when applying loads in three simultaneous, orthogonal axes. A complex system of levers, cranks, and cables must be used, introducing increased sources of systematic error, and significantly increasing the time and labor intensity required to complete the calibration. One aspect of the VACS is a method wherein the mass utilized for calibration is held constant, and the acceleration is changed to thereby generate relatively large forces with relatively small test masses. Multiple forces can be applied to a force balance without changing the test mass, and dynamic forces can be applied by rotation or oscillating acceleration. If rotational motion is utilized, a mass is rigidly attached to a force balance, and the mass is exposed to a rotational field. A large force can be applied by utilizing a large rotational velocity. A centrifuge or rotating table can be used to create the rotational field, and fixtures can be utilized to position the force balance. The acceleration may also be linear. For example, a table that moves linearly and accelerates in a sinusoidal manner may also be utilized. The test mass does not have to move in a path that is parallel to the ground, and no re-leveling is therefore required. Balance deflection corrections may be applied passively by monitoring the orientation of the force balance with a three-axis accelerometer package. Deflections are measured during each test run, and adjustments with respect to the true applied load can be made during the post-processing stage. This paper will present the development and testing of the VASC concept.

Rhew, Ray D.↗