Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “system”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Development of highly efficient NEG pumping system for EBIS

Ultrahigh vacuum inside the ion trap volume is crucial for stable and reliable operation of an Electron Beam Ion Source (EBIS). We have developed and tested a compact linear pumping system based on the ZAO Non-Evaporable Getter (NEG) module with high pumping speed and enhanced sorption capacity for all active gases. Due to its minimal transverse dimensions, the system can be mounted adjacent to the ion trap inside a superconducting solenoid bore and will provide a pumping speed of the order of 1000 l/s for all active gases in that area. An externally supplied current (100 A DC) is used to heat the ZAO NEG up to 650 °C for more than 1 h, which is required for pump activation and/or reactivation cycles. The pumping system is being developed for use in the Extended EBIS Upgrade which is presently in progress at BNL. In conclusion, the design of the system and results of multiple tests are presented and discussed.

43 PARTICLE ACCELERATORS↗

Interpreting Write Performance of Supercomputer I/O Systems with Regression Models

This work seeks to advance the state of the art in HPC I/O performance analysis and interpretation. In particular, we demonstrate effective techniques to: (1) model output performance in the presence of I/O interference from production loads; (2) build features from write patterns and key parameters of the system architecture and configurations; (3) employ suitable machine learning algorithms to improve model accuracy. We train models with five popular regression algorithms and conduct experiments on two distinct production HPC platforms. We find that the lasso and random forest models predict output performance with high accuracy on both of the target systems. We also explore use of the models to guide adaptation in I/O middleware systems, and show potential for improvements of at least 15% from model-guided adaptation on 70% of samples, and improvements up to 10× on some samples for both of the target systems.

Xie, Bing↗

A Systems Engineering Analysis of National Ignition Facility Industrial Controls Systems and Safety Interlock Systems Remote Input/Output Networking Migration from ControlNet to EtherNet/IP

The ControlNet industrial communications protocol and modules used in the Industrial Control System (ICS) and Safety Interlock System (SIS) at the National Ignition Facility (NIF) are no longer necessary and the ICS and SIS would be better served by migrating the communications structure to use EtherNet/Industrial Protocol (IP) and EtherNet bridge modules instead. By the admission of the vendor of ControlNet hardware, Rockwell Automation, in literature by Bill Petro [1], “Moving forward, customers will be able to optimize their asset utilization better using EtherNet/IP protocol than with ControlNet.” The NIF is one of the key elements of the Inertial Confinement Fusion (ICF) program at Lawrence Livermore National Laboratory (LLNL), a federally funded research and development center (FFRDC). The NIF contains the systems and provides the operational capacity to perform ICF, high energy density (HED), and discovery science experiments utilizing 192 individual beamlines, a host of diagnostics, and all the industrial systems required to facilitate these beamlines and diagnostics. The industrial systems are governed by the ICS and SIS, with the ICS providing control and the SIS providing monitoring and permissives. Construction on the NIF began in 1997 and was certified complete in 2009 and, as a result, the ICS and SIS were developed during this time using the tools that were available then. This includes the communications structure and protocols for these systems, much of which was, and still is, ControlNet. ControlNet, particularly during the time that the ICS and SIS were being built, has several attractive features. ControlNet hardware is exclusive to Rockwell Automation, which was the automation hardware chosen for the ICS and SIS. One feature that could be considered an advantage or a disadvantage depending on the communication needs of the system is that ControlNet also utilizes no active network components, excluding repeaters which are not always necessary. According to the architect of the ICS system at the NIF, Gordon Lau, one of the most attractive features of the ControlNet protocol during development of the ICS and SIS was that it is deterministic, providing timing of data transfer that is executed exactly as it is defined by the developer.

42 ENGINEERING↗

Data Systems Dynamic Simulation - A total system for data system design assessments and trade studies

Data Systems Dynamic Simulation is a simulation system designed to reduce cost and time and increase the confidence and comprehensiveness of Data Systems Simulation. It is designed to simulate large data processing and communications systems from end-to-end or by subsystem. Those features relevant to system timing, control, sizing, personnel support activities, cost and external influences are modeled. Emphasis is placed on ease of use, comprehensive system performance measures, and extensive post simulation analysis capability. The system has been used to support trade studies of the NASA data system needs in the 1985 to 1990 time frame.

Hooper, J. W.↗

Internal Active Thermal Control System (IATCS) Sodium Bicarbonate/Carbonate Buffer in an Open Aqueous Carbon Dioxide System and Corollary Electrochemical/Chemical Reactions Relative to System pH Changes

The International Space Station (ISS) Internal Active Thermal Control System (IATCS) experienced a number of chemical changes driven by system absorption of CO2 which altered the coolant’s pH. The natural effects of the decrease in pH from approximately 9.2 to less than 8.4 had immediate consequences on system corrosion rates and corrosion product interactions with specified coolant constituents. The alkalinity of the system was increased through the development and implementation of a carbonate/bicarbonate buffer that would increase coolant pH to 9.0 – 10.0 and maintain pH above 9.0 in the presence of ISS cabin concentrations of CO2 up to twenty times higher than ground concentrations. This paper defines how a carbonate/bicarbonate buffer works in an open carbon dioxide system and summarizes the analyses performed on the buffer for safe and effective application in the on-orbit system. The importance of the relationship between the cabin environment and the IATCS is demonstrated as the dominant factor in understanding the system chemistry and pH trends before and after addition of the carbonate/bicarbonate buffer. The paper also documents the corollary electrochemical and chemical reactions the system has experienced and the rationale for remediation of these effects with the addition of the carbonate/bicarbonate buffer.

Stegman, Thomas W.↗

Machine-learning error models for approximate solutions to parameterized systems of nonlinear equations

Here, this work proposes a machine-learning framework for constructing statistical models of errors incurred by approximate solutions to parameterized systems of nonlinear equations. These approximate solutions may arise from early termination of an iterative method, a lower-fidelity model, or a projection-based reduced-order model, for example. The proposed statistical model comprises the sum of a deterministic regression-function model and a stochastic noise model. The method constructs the regression-function model by applying regression techniques from machine learning (e.g., support vector regression, artificial neural networks) to map features (i.e., error indicators such as sampled elements of the residual) to a prediction of the approximate-solution error. The method constructs the noise model as a mean-zero Gaussian random variable whose variance is computed as the sample variance of the approximate-solution error on a test set; this variance can be interpreted as the epistemic uncertainty introduced by the approximate solution. This work considers a wide range of feature-engineering methods, data-set-construction techniques, and regression techniques that aim to ensure that (1) the features are cheaply computable, (2) the noise model exhibits low variance (i.e., low epistemic uncertainty introduced), and (3) the regression model generalizes to independent test data. Finally, numerical experiments performed on several computational-mechanics problems and types of approximate solutions demonstrate the ability of the method to generate statistical models of the error that satisfy these criteria and significantly outperform more commonly adopted approaches for error modeling.

97 MATHEMATICS AND COMPUTING↗

A framework for modeling and optimizing dynamic systems under uncertainty

Algebraic modeling languages (AMLs) have drastically simplified the implementation of algebraic optimization problems. However, there are still many classes of optimization problems that are not easily represented in most AMLs. These classes of problems are typically reformulated before implementation, which requires significant effort and time from the modeler and obscures the original problem structure or context. In this work we demonstrate how the Pyomo AML can be used to represent complex optimization problems using high-level modeling constructs. We focus on the operation of dynamic systems under uncertainty and demonstrate the combination of Pyomo extensions for dynamic optimization and stochastic programming. We use a dynamic semibatch reactor model and a large-scale bubbling fluidized bed adsorber model as test cases.

97 MATHEMATICS AND COMPUTING↗

Comparison of 3-dimensional dose reconstruction system between fluence-based system and dose measurement-guided system

COMPASS system (IBA Dosimetry, Schwarzenbruck, Germany) and ArcCHECK with 3DVH software (Sun Nuclear Corp., Melbourne, FL) are commercial quasi-3-dimensional (3D) dosimetry arrays. Cross-validation to compare them under the same conditions, such as a treatment plan, allows for clear evaluation of such measurement devices. In this study, we evaluated the accuracy of reconstructed dose distributions from the COMPASS system and ArcCHECK with 3DVH software using Monte Carlo simulation (MC) for multi-leaf collimator (MLC) test patterns and clinical VMAT plans. In a phantom study, ArcCHECK 3DVH showed clear differences from COMPASS, measurement and MC due to the detector resolution and the dose reconstruction method. Especially, ArcCHECK 3DVH showed 7% difference from MC for the heterogeneous phantom. ArcCHECK 3DVH only corrects the 3D dose distribution of treatment planning system (TPS) using ArcCHECK measurement, and therefore the accuracy of ArcCHECK 3DVH depends on TPS. In contrast, COMPASS showed good agreement with MC for all cases. However, the COMPASS system requires many complicated installation procedures such as beam modeling, and appropriate commissioning is needed. In terms of clinical cases, there were no large differences for each QA device. The accuracy of the compass and ArcCHECK 3DVH systems for phantoms and clinical cases was compared. Both systems have advantages and disadvantages for clinical use, and consideration of the operating environment is important. The QA system selection is depending on the purpose and workflow in each hospital.

61 RADIATION PROTECTION AND DOSIMETRY↗

Dynamical System Scaling of a Thermocline Thermal Storage System in the Thermal Energy Distribution System (TEDS) Facility

The purpose of this study was to develop a process to convert input signals from one facility into another by reflecting geometric and environmental settings. The Dynamic Energy Transport and Integration Laboratory (DETAIL) is one facility in development that aims to emulate the daily interactions among power production industry systems and be capable of receiving real-time data from those systems as inputs. To convert signals and ensure that the temporal sequences and magnitudes reflect the laboratory settings, the ability to scale and project data is essential. To demonstrate this ability, Dynamical System Scaling (a methodology that enables systems to scale and project or extrapolate datasets to desired environments while conserving the observed transient behavior based on first principles) was applied to DETAIL’s thermocline thermal storage system in the Thermal Energy Distribution System. The thermocline system was successfully scaled and a test case was conducted to generate a doubly accelerated energy charge and discharge in reference to past experimental data from the facility. The accelerated data were determined as able to conserve the amount of energy stored and the associated test boundary conditions were charge line maximum temperature, charge line velocity, and thermocline maximum temperature at 354 °C, 0.458 m/s, and 418 °C, respectively. The research results represented a case that required signals to be accelerated without altering the stored energy.

Yoshiura, Ramon (ORCID:0000000319781313)↗

Flight set 360L007 (STS-33R) field joint protection system, thermal protection system, and systems tunnel components, volume 7

The performance of the thermal protection system, field joint protection system, and systems tunnel components of flight set 360L007 is presented as evaluated by postflight hardware inspection. The condition of both motors was similar to previous flights. Four aft edge strikes were noted on the ground environment instrumentation thermal protection system. The hits all left a clean substrate, indicating that the damage was caused by nozzle severance debris and/or water impact. No National Space Transportation System debris criteria for missing thermal protection system were violated. Two problem reports were written against the field joint protection system. The first concerned two cracks in the K5NA closeout over the trunnion/vent valve location on the left-hand aft field joint. A similar condition was observed on Flight 5 (360H005). The second problem report referred to a number of small surface cracks between two impact marks on the left-hand forward field joint. Neither area exhibited loose material or any abnormal heat effects, and they have no impact on flight safety.

Source record↗

Flight Set 360L006 STS-34 field joint protection system, thermal protection system, and systems tunnel components, volume 4

The performance of the thermal protection system, field joint protection system, and systems tunnel components of Flight Set 360L006, are documented, as evaluated by postflight hardware inspection. The condition of both motors was similar to previous flights. Sixteen aft edge hits were noted on the ground environment instrumentation thermal protection system. Each hit left a clean substrate, indicating that the damage was caused by nozzle severance debris and/or water impact. No National Space and Transporation System debris criteria for missing thermal protection system were violated. One 5.0 by 1.0 in. unbond was observed on the left hand center field joint K5NA closeout and was elevated to an in-flight anomaly (STS-34-M-4) by the NASA Ice/Debris team. Aft edge damage to the K5NA and an associated black streak indicate that burning debris from the nozzle severance system was the likely cause of the damage. Minor divots caused by debris were seen on previous flights, but this is the first occurrence of a K5NA unbond. Since the unbond occurred after booster separation there is no impact on flight safety and no corrective actions was taken. The right hand center field joint primary heater failed the dielectric withstanding voltage test after joint closeout. The heater was then disabled by opening the circuit breaker, and the redundant heater was used. The redundant heater performed nominally during the launch countdown. A similar condition occurred on Flight 4 when a secondary joint heater failed the dielectric withstanding voltage test.

Wilkinson, J. P.↗

Inductive monitoring system constructed from nominal system data and its use in real-time system monitoring

The present invention relates to an Inductive Monitoring System (IMS), its software implementations, hardware embodiments and applications. Training data is received, typically nominal system data acquired from sensors in normally operating systems or from detailed system simulations. The training data is formed into vectors that are used to generate a knowledge database having clusters of nominal operating regions therein. IMS monitors a system's performance or health by comparing cluster parameters in the knowledge database with incoming sensor data from a monitored-system formed into vectors. Nominal performance is concluded when a monitored-system vector is determined to lie within a nominal operating region cluster or lies sufficiently close to a such a cluster as determined by a threshold value and a distance metric. Some embodiments of IMS include cluster indexing and retrieval methods that increase the execution speed of IMS.

Iverson, David L.↗

Accelerating Simulation for High-Fidelity PV Inverter System Reliability Assessment with High-Performance Computing

The overall cost of photovoltaic (PV) systems has shown a downward trend during the last decade; however, PV inverter failures account for the highest cost of operation and maintenance. To address this, reliability tools with powerful computation and better accuracy are required for the lifetime prediction and degradation evaluation of PV inverters. This paper proposes an event-driven parallel computing-based simulator. The proposed simulator applies high-performance computing techniques and other accessory optimization techniques-including cluster merging, adaptive model updates, and steady-state identification-to make reliability assessments for PV inverters under given input mission profiles and operating conditions with high efficiency and high fidelity. The main idea of the simulator and its workflow are introduced. Then, a demo PV inverter system simulator is implemented, and the speedup of the total simulations of the switching model reaches 123.03 times.

high-performance computing↗

Coordination of Transmission, Distribution and Communication Systems for Prompt Power System Recovery after Disasters:Report – Grid and Communication Interdependency Review and Characterization of Typical Communication Systems

In this report, we first reviewed communication technologies and systems for the grid as well as their roles (impact) in restoration, aiming to fill the knowledge gap of interdependence between the physical grid and the communication system. We also proposed several key characteristics and metrics of typical communication systems based on analysis of a realistic communication system. These metrics and characteristics will be used as input for developing or generating synthetic communication systems in the next phase. Lastly, we reviewed methods of creating synthetic power system models and proposed improvements to one potential method that will be considered in the next phase of the project.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Synchrotron X-ray microfluorescence measurement of metal distributions in Phragmites australis root system in the Yangtze River intertidal zone

This study investigates the distributions of Br, Ca, Cl, Cr, Cu, K, Fe, Mn, Pb, Ti, V and Zn in Phragmites australis root system and the function of Fe nanoparticles in scavenging metals in the root epidermis using synchrotron X-ray microfluorescence, synchrotron transmission X-ray microscope measurement and synchrotron X-ray absorption near-edge structure techniques. The purpose of this study is to understand the mobility of metals in wetland plant root systems after their uptake from rhizosphere soils. Phragmites australis samples were collected in the Yangtze River intertidal zone in July 2013. The results indicate that Fe nanoparticles are present in the root epidermis and that other metals correlate significantly with Fe, suggesting that Fe nanoparticles play an important role in metal scavenging in the epidermis.

Feng, Huan↗

Cryptography Considerations for Distributed Energy Resource Systems

Distributed energy resource (DER) systems are rapidly being adopted and integrated within the electric power grid. Developments in smart grid devices and communication protocols are advancing the power system domain but are also introducing new cyber attack vectors. In particular, the ability to maintain the confidentiality, integrity, and availability of data is of increasing concern. Cryptography is a powerful tool that can be leveraged to protect DER systems and their critical information. This paper discusses prominent methods of cryptographic authentication and encryption that can be used to secure DER communications. Specific considerations and recommendations for applying cryptography to DER systems are provided, including system design constraints and system impact. These will be demonstrated with two case studies that assess cryptography hardware requirements and communications latency in DERs.

24 POWER TRANSMISSION AND DISTRIBUTION↗