Application of Temperature Sensitivities During Iterative Strain-Gage Balance Calibration Analysis

A new method is discussed that may be used to correct wind tunnel strain-gage balance load predictions for the influence of residual temperature effects at the location of the strain-gages. The method was designed for the iterative analysis technique that is used in the aerospace testing community to predict balance loads from strain-gage outputs during a wind tunnel test. The new method implicitly applies temperature corrections to the gage outputs during the load iteration process. Therefore, it can use uncorrected gage outputs directly as input for the load calculations. The new method is applied in several steps. First, balance calibration data is analyzed in the usual manner assuming that the balance temperature was kept constant during the calibration. Then, the temperature difference relative to the calibration temperature is introduced as a new independent variable for each strain--gage output. Therefore, sensors must exist near the strain--gages so that the required temperature differences can be measured during the wind tunnel test. In addition, the format of the regression coefficient matrix needs to be extended so that it can support the new independent variables. In the next step, the extended regression coefficient matrix of the original calibration data is modified by using the manufacturer specified temperature sensitivity of each strain--gage as the regression coefficient of the corresponding temperature difference variable. Finally, the modified regression coefficient matrix is converted to a data reduction matrix that the iterative analysis technique needs for the calculation of balance loads. Original calibration data and modified check load data of NASA's MC60D balance are used to illustrate the new method.

Ulbrich, N.↗

Strain gage system evaluation program

A program was conducted to determine the reliability of various strain gage systems when applied to rotating compressor blades in an aircraft gas turbine engine. A survey of current technology strain gage systems was conducted to provide a basis for selecting candidate systems for evaluation. Testing and evaluation was conducted in an F 100 engine. Sixty strain gage systems of seven different designs were installed on the first and third stages of an F 100 engine fan. Nineteen strain gage failures occurred during 62 hours of engine operation, for a survival rate of 68 percent. Of the failures, 16 occurred at blade-to-disk leadwire jumps (84 percent), two at a leadwire splice (11 percent), and one at a gage splice (5 percent). Effects of erosion, temperature, G-loading, and stress levels are discussed. Results of a post-test analysis of the individual components of each strain gage system are presented.

Dolleris, G. W.↗

Development of high temperature strain gages

High temperature electric resistance wire strain gages were developed and evaluated for use at temperatures exceeding 922 K (1200 F). A special high temperature strain gage alloy (Fe-25Cr-7.5A1), designated BCL-3, was used to fabricate the gages. Pertinent gage characteristics were determined at temperatures up to 1255 K (1800 F). The results of the evaluation were reported in graphical and tabular form. It was concluded that the gages will perform satisfactorily at temperatures to at least 1089 K (1500 F) for at least one hour.

Lemcoe, M. M.↗

Coating permits use of strain gage in water and liquid hydrogen

Strain gage installation covered with a three-layer coating of commercial materials makes measurements in water and liquid hydrogen. It consists of a selected foil strain gage bonded with a modified commercial heat-curring epoxy cement. The outer protective layer of the gage installation may develop cracks when immersed in liquid hydrogen.

Berven, B. B.↗

Strain gage barometric transmitter

A strain gage barometric transmitter for measuring the atmospheric pressure in severe environmental conditions is described. This equipment specifications are presented and its performance assessed. It is shown that this barometric sensor can measure the atmospheric pressure with a precision of 0.5 mb during a 6 month period.

Viton, P.↗

Internally Mounting Strain Gages

Technique for mounting strain gages inside bolt or cylinder simultaneously inserts gage, attached dowel segment, and length of expandable tubing. Expandable tubing holds gage in place while adhesive cures, assuring even distribution of pressure on gage and area gaged.

Jett, J. R., Jr.↗

Recommended Strain Gage Application Procedures for Various Langley Research Center Balances and Test Articles

The NASA Langley Research Center uses more than 10000 strain gages per year in supporting its various research programs. The character of the testing at LaRC is such that the types of strain gage installations, the materials they are applied to, and the test environments encountered, require many varied approaches for installing strain gages. These installations must be accomplished in the most technically discerning and appropriate manner. This technical memorandum is offered as an assisting guide in helping the strain gage user to determine the appropriate approach for a given strain gage application requirement. Specifically, this document offers detailed recommendations for strain gaging the following: LaRC-Designed balances, LARC custom transducers, certain composite materials and alloys, high-temperature test articles, and selected non-typical or unique materials or test conditions.

Moore, Thomas C., Sr.↗

Evaluation of Pd-Cr Wires for Strain Gage Application

A newly developed alloy, palladium-13 weight percent chromium (Pd13Cr), was identified by United Technologies Research Center under a NASA contract to be the best material for high temperature strain gage applications. An electrical resistance strain gage that can provide accurate static strain measurement to a temperature higher than that of a commercially available gage is urgently needed in aerospace and aeronautics research. A strain gage made of a 25.4 micron (1 mil) diameter Pd13Cr wire has been recently demonstrated to be usable for static strain measurements to 800 C. This compares to the 400 C temperature limit of the commercially available strain gages. The performance of the Pd-Cr gage, however, strongly depends on the quality of the Pd13Cr wire. Four batches of Pd-Cr wires purchased from three different manufacturers were therefore evaluated to determine the best source of the wire for strain gage applications. The three suppliers were Precious Metal Institute in China, Sigmund Cohn Co., and G & S Titanium, Inc. in the United States. Two batches of wires obtained from Previous Metal Institute in 1987 and 1992, respectively are referred to herein as China87 and China92 wires. The mechanical, chemical and electrical properties of these wires, both as-received and after high temperature exposures at 800 C for 50 hours were analyzed. The elastic modulus and the failure strength of the wires were evaluated using a tensile test machine equipped with a laser speckle strain measurement system. The chemical and microstructural properties of the wires were inspected using a plasma atomic emission spectrometer and a scanning electron microscope (SEM) equipped with an energy dispersive X-ray spectroscope (EDS). The electrical stability and repeatability of the wires were determined by measuring the electrical resistance of the wires during three thermal cycles to 1000 C and a ten-hour soak at 1000 C. As a result of this study, the wire which has the highest strength, the least impurities content, the best oxidation resistance and the best electrical stability will be selected for upcoming strain gage applications.

Lei, Jih-Fen↗

The NASA strain gage laboratory

The goal of the NASA-sponsored high-temperature high-strain gage program (which combines in-house, contract, and grant work) is to develop a gage that will measure static strains up to 2000 microstrain to within 10 percent, and at temperatures up to 1250 K (typical for combustors and turbine blades and vanes of gas turbine engines) maintained over 50-h period. The basic equipment of the NASA in-house lab is described (with special attention given to the strain-gage testing system), and some examples of recent test results are discussed. Data are presented on following tests performed on four gages: apparent strain vs temperature at different cooling rates, gage factor at various strain and temperature levels, and drift and creep tests at 133 C.

Hobart, Howard F.↗

Practical approaches for application of hi-temperature strain gages on high temperature composites

Four major areas of interest with respect to utilizing strain gages on carbon/carbon (with SiC surfaces) and titanium matrix composites are addressed. Strain gage and adhesive combinations on carbon/carbon (C/C) at temperatures from minus 190 C to 540 C, half-bridge gaging for reducing apparent strain on C/C using Poisson's ratio and bending configurations, review of the 'field installation' techniques developed for gaging a C/C hypersonic generic elevon, and results of initial strain gaging efforts on titanium matrix composites are discussed. Current research in developing techniques for increasing the maximum temperature for strain gages on carbon/carbon are reviewed.

Moore, Thomas C., Sr.↗

Practical approaches for application of resistance type strain gages on high temperature composites

Four major areas of interest with respect to utilizing strain gages on carbon/carbon (with SiC surfaces) and titanium matrix composites are addressed. Strain gage and adhesive combinations on carbon/carbon (C/C) at temperatures from minus 190 C to to 540 C, half-bridge gaging for reducing apparent strain on C/C using Poisson's ratio and bending configurations, a review of the 'field installation' techniques developed for gaging a C/C hypersonic generic elevon, and results of initial strain gaging efforts on titanium matrix composites are discussed. Current research in developing techniques for increasing the maximum temperature for strain gages on carbon/carbon are reviewed.

Moore, Thomas C., Sr.↗

NASA LaRC Strain Gage Balance Design Concepts

The NASA Langley Research Center (LaRC) has been designing strain-gage balances for more than fifty years. These balances have been utilized in Langley's wind tunnels, which span over a wide variety of aerodynamic test regimes, as well as other ground based test facilities and in space flight applications. As a result, the designs encompass a large array of sizes, loads, and environmental effects. Currently Langley has more than 300 balances available for its researchers. This paper will focus on the design concepts for internal sting mounted strain-gage balances. However, these techniques can be applied to all force measurement design applications. Strain-gage balance concepts that have been developed over the years including material selection, sting, model interfaces, measuring, sections, fabrication, strain-gaging and calibration will be discussed.

Rhew, Ray D.↗

Alumina Encapsulated Strain Gage Not Mechanically Attached To The Substrate, Used to Temperature Compensate an Active High Temperature Gage In A Half-Bridge Configuration

A temperature compensation element for a high-temperature strain gage and the method of fabricating the same. Preferably, the element is a "dummy" strain gage not mechanically attached to the substrate. The element is encapsulated in an insulative material and used to compensate an active high-temperature strain gage and wired in a half-bridge configuration. The temperature compensation element and high-temperature strain gage are fabricated using the method of the present invention. This method includes temporarily adhering the element to a heat sink, encapsulated in an insulative material and then removed from the heat sink. Next, the element is either stacked or placed near the active gage. Ideally, the element and the active gage have substantially similar heat transfer and electrical properties.

Anthony Piazza↗

Elevated temperature strain gages

Materials were evaluated that could be used in manufacturing electrical resistance strain gages for static strain measurements at temperatures at or above 1273 K. Strain gage materials must have a characteristic response to strain, temperature and time that is reproducible or that varies in a predictable manner within specified limits. Several metallic alloys were evaluated, as well as a series of transition metal carbides, nitrides and silicides.

Brittain, J. O.↗

Strain gage selection in loads equations using a genetic algorithm

Traditionally, structural loads are measured using strain gages. A loads calibration test must be done before loads can be accurately measured. In one measurement method, a series of point loads is applied to the structure, and loads equations are derived via the least squares curve fitting algorithm using the strain gage responses to the applied point loads. However, many research structures are highly instrumented with strain gages, and the number and selection of gages used in a loads equation can be problematic. This paper presents an improved technique using a genetic algorithm to choose the strain gages used in the loads equations. Also presented are a comparison of the genetic algorithm performance with the current T-value technique and a variant known as the Best Step-down technique. Examples are shown using aerospace vehicle wings of high and low aspect ratio. In addition, a significant limitation in the current methods is revealed. The genetic algorithm arrived at a comparable or superior set of gages with significantly less human effort, and could be applied in instances when the current methods could not.

Source record↗

A Portable Calibrator for Dynamic Strain Gages

A portable device for calibrating dynamic strain gages is described. The device contains a motor-driven cam, which applies alternating tensile loads to a metal strip 5/8 inch wide and 6 1/4 inches long. The cam is designed to produce a nearly sinusoidal variation of strain with time. Dynamic strain gages with gage lengths up to 5 inches may be calibrated by mounting them on the strip and by changing the frequency and the amplitude of the tensile load. The frequency may be varied from 15 to 30 cycles per second and the strain amplitude from 0 to 10x10-4 in steps of 2x10-4.

Mcpherson, Albert E↗

PdCr based high temperature static strain gage

The program at NASA Lewis Research Center to develop a high temperature static strain gage system for the hypersonic vehicle and turbine engine research has emphasized a palladium-13 wt pct chromium (PdCr) alloy. Gages made from this alloy are being developed in both fine wire and thin film form. The wire gage system had platinum wire as a temperature compensator and was coated with a special alumina and zirconia mixture overcoat. This PdCr compensated wire gage responded linearly to the imposed strain to at least 1000 microstrain. The apparent strain varied within 300 microstrain from room temperature to 800 C with a reproducibility within 50 microstrain between thermal cycles to 800 C. The sputtered thin film PdCr strain gage, whose size was 8 x 8 mm and 10 microns thick, has demonstrated the possibility of extending the use of the PdCr strain gage to a temperature of approximately 1000 C.

Lei, Jih-Fen↗